My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8309 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8309 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:38:21 PM
Creation date
2/27/2025 1:20:56 PM
Metadata
Fields
Template:
Building Plans
Street #
8309
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
2804
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
✓U�UQIIJI l Gl Ivolupc I . l vuI ( Il-vnv 10-'ir1Y U-:11 I'1li G/-1'iV.7CV I Of Lim <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />EXISTING EXTERIOR CMU --\ H <br />I <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ ° <br />(2) ROWS OF 3/6" DIA. TAPCONS ° D / D D <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />° D EXISTING FOUNDATION. <br />I p ° <br />ID <br />-A \ ° <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOWSILL <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/6" DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />° p-- ---- p -a — <br />/ <br />D D <br />D D EXISTING FOUNDATION <br />D ° <br />I � <br />D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />° <br />--d — — d 0" <br />— — d e ° d DEEP) <br />A d ° <br />< <br />d 4 <br />\\\� i / 4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />6 BEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />° d <br />— — — — — — d — <br />d d a ° ° d <br />d <br />a r, <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />"SUS BAR AS <br />_AP AS SHOWN <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL <br />CMUIc <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 24" <br />INTO MONOLITHIC THICKENED EDGE <br />DEGREE <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />#4 OR #5 <br />REINFORCING PER <br />MONOLITHIC FOOTING <br />SECTION <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />• STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />• ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />LOCATE AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT IN LAST REINFORCEMENT <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAI <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH 8" CMU CHAIR <br />TOP OF SLAB i, I A BLOCK W/ (1) #4 OR #5 CONT. <br />LU <br />_ U) <br />W Q o <br />VAPOR BARRIER �\\LU o X <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />o I o <br />A4 OR <br />FOOTING TO BEAR ON FIRM #6 NI BIONALRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />-� FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. <br />(BEYOND) <br />FLOATING CONCRETE w <br />SLAB W/ 6x6 W1.4xW1.4 <br />WWF OR FIBERMESH > <br />q <br />U-BLOCK W/ <br />U J <br />(1)#4OR#5 <br />Q <br />w <br />CONT <br />ww <br />U) <br />c <br />FINISH <br />O <br />GRADE <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />(f)_STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />(1) #4 OR #5 CONT. <br />3VARIES PER <br />6" MAX <br />ARCH PLANS <br />12" MIN` <br />4/?l <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />3'Y2' CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />° d ° <br />VAPOR BARRIER <br />d ✓/ FOOTING TO BEAR ON FIRM <br />a • ,/ UNDISTURBED SOIL <br />b <br />12" UNDER 1 STORY WALL W/ <br />ADDITIONAL NO.4 OR NO. 5 #4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL W/ <br />1#4 OR (2) #5 CONT <br />1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />NOTE*: IT IS ACCEPTABLE TO SUBSTITUTE THIS., <br />HIS .,1A" FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />,o— -- — — <br />O <br />Am,\ >; <br />U <br />ALL OTHER EXTERIOR WALL O <br />\\\//� o o CLADDING MIN 8", U.N.O. ON ARCH O p <br />APEXVAPOR BARRIER \//\\ o p \\ �\///\\\/f\\\\/\\/� � -� <br />\/ ^\ 12"MIN /\/\/\/\/\/ 04 U <br />FOOTING TO BEAR ON 6 OPT. EXTENSION IN BRICK <br />FIRM UNDISTURBEDSOIL LOCATIONS ON FND PLAN N �' <br />12" UNDER 1 STORY WALL w/ 04 <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J a <br />BAR IN BRICK LEDGE LL - <br />16" UNDER 2 STORY WALL w/ LU <br />(2) #5 OR (3) #4 CONTINUOUS J <br />tds <br />-0 <br />true design studios <br />&FOLLOWING <br />NOLITHIC FOOTING SECTION z <br />NTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE OCCUR: <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. O <br />O <br />CONCRETE SLAB w/ 6x6 LLI <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR _ <br />FIBERMESH Uft wt 0 (D <br />° - - ------- U$HOMON <br />' <br />d d /\\ �\ /\\/\\ Ne <br />16" LLI <br />VAPOR BARRIER Q 4- <br />0 <br />c Q <br />3 BEARING WALL FOOTING SECTION z <br />w <br />O <br />w <br />CONCRETE SLAB W/ 6x6 w <br />W1.4 x W1.4 WWF OR O <br />FIBERMESH O <br />0' 0" A.F.F. <br />SEE ARCH � <br />\d a <br />DETAILS <br />a ~ <br />° <br />LO <br />>= <br />8" MIN O �^ <br />\/ Z W <br />8"x8" THICKENED 8" U)LL <br />FTG AT W <br />STEP-DOWN, SEE VAPOR BARRIER Z <br />PLAN U J Z W <br />4 CURB STEP SECTION m Uj O U) <br />w <br />W QW <br />8" UNDER MASONRY WALL Z <br />CONCRETE SLAB W/ 6" UNDER WOOD WALL Z Q Q <br />6x6 W1.4 x W1 A WWF W � W w <br />OR FIBERMESH VARIES d SEE ARCH 0 W <br />w <br />Q W <br />d <br />dQ — ° 4,A —. ° (MAX 16") W f�- <br />// //\// O X <br />d 12" MIN\/\%\�\%\%\i Z <br />\Z <br />VAPOR BARRIER /// ° a \ //%//�//i// O <br />W <br />6" OPT. EXTENSION IN BRICK O('- <br />LOCATIONS ON FND PLAN a tt =< /Z_/ <br />12" UNDER 1 STORY WALL w/ O <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 U LL, <br />BAR IN BRICK LEDGE — <br />16" UNDER 2 STORY WALL w/ Q w <br />� J <br />(2) #5 OR (3) #4 CONTINUOUS Abbott Park <br />O U <br />5 G�AE <br />E EXT WALL CURB SECTION � � <br />COOR PRIOR TO CONSTRUCTION IF ANY OF THE LOT 034-03FOLOG OCCUR: <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U Z <br />e GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z <br />FROM STRUCTURE STEEPER THAN V-0" VERTICALLY 0 <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. U) <br />O PROJECT NO: w <br />CONCRETE SLAB W/ 6x6 1 2021.009228 <br />W1.4 x W1.4 WWF OR O w <br />FIBERMESH Z CRAM0 <br />0'-0" A.F.F. SEE ARCH U JAR o <br />d — a — — — (MAX 20" W L0 <br />\\ \\ \< ° d d d DEEP) cHKD. MJP U) <br />X <br />° • d <br />4" EXTENSION X tttlittllr�� U <br />UNDER BRICK VENEER Q �t'(iN <br />�G E IV . F9 �i�� � <br />12" UNDER 1 STORY WALL }' �� .•'� SF '.• <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m i Z <br />No 85166 <br />16" UNDER 2 STORY WALL W * DocuSigned by: ; * Q <br />w/ (3) #4 OR (2) #5 CONT Z <br />BEARING CURB STEP SECTION O ©�'•��F43�441 <br />w� , <br />6 :�: <br />Z ��;�r0 N AL E�, %``` <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />II L <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />SEE NOTES (MAX 16") U <br />STUCCO OR DIRECTLY ADHERED cli <br />STONE CLADDING FINISH - MIN 6" a, <br />0 <br />N <br />� rruttt <br />Q <br />O_ 07-28-2021 p <br />H W <br />U_ REVISIONS: <br />U_ <br />Q No. Description Date <br />J <br />U' U) <br />O �- <br />Z Z <br />= O <br />U 0 <br />w <br />I— <br />x <br />W ST=2mD <br />d <br />Q <br />CMU/METAL CONNECTOR ENGINEERING <br />
The URL can be used to link to this page
Your browser does not support the video tag.