Laserfiche WebLink
60CUSlgn Envelope ID: 12B06693-F413-4080-990E-97E259316259 <br />EXISTING EXTERIOR CMU <br />I r� <br />MIN. 3" EDGE DISTANCE I 11 <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO _ <br />EXISTING FOUNDATION FACE w/ ° ° — — — — —& — <br />(2) ROWS OF 316" DIA. TAPCONS D / D D D ° D D <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. i 1> <br />D D EXISTING FOUNDATION. <br />° 1p ° <br />D <br />ID �\ <br />_a — <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOWSILL <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE P, <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ ° — — — — — — ° <br />(2) ROWS OF 3/6" DIA. TAPCONS F — D D — D <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. i <br />D EXISTING FOUNDATION <br />D ° <br />° D <br />D \ \ <br />D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />U-0" A.F.F. SEE ARCH <br />—d — — — - — — (MAX 20" <br />VA V�/VA ° d ° DEEP) <br />j\\ <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />*BEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />° a <br />d ° a <br />i". <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />1 An �lC //II.ITIAl000S BAR AS <br />2" LAMP AS SHOWN <br />90 DEGREE <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL, <br />CMU STEMWALLMONO LITHIC SLAB <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 24" <br />INTO MONOLITHIC THICKENED EDGE <br />U)O <br />cc�_ <br />oz <br />UZ <br />Q <br />C') W <br />LOCATE AND TIE INTO STEMW <br />REINFORCEMENT IN LAST REI <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />• 4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />-°---------- <br />s, <br />° d ° e #4 OR #5 <br />REINFORCING PER <br />d • ° MONOLITHIC FOOTING <br />° SECTION <br />° ° FOOTING TO BEAR ON FIRM <br />d° ° a • ° UNDISTURBED SOIL <br />• STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />• ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />ALL FOOTING <br />NFORCEMENT <br />CONCRETE SLAB W/ <br />6x6 WI A x W1.4 WWF <br />OR FIBER MESH <br />TOP OF SLAB j, <br />W <br />_ U) <br />o <br />VAPOR BARRIER x <br />#4 OR #5 VERT REINFORCINGUP <br />4 TO b COURSES: S 48" O.C. <br />N. A l,/ 0 2 <br />8" CMU CHAIR <br />BLOCK W/ (1) #4 OR #5 CONT. <br />OR <br />FOOTING TO BEAR ON FIRM �� . //�\ j\\' \ ADDITIONAL IRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT - 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS -- <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. Ah <br />(BEYOND) <br />FLOATING CONCRETE - w_ <br />SLAB W/ 6x6 W1.4xW1.4 O <br />WWF OR FIBERMESH > <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />U-BLOCK W/ <br />v J <br />(1)#4OR#5 <br />Q � <br />U) <br />CONT <br />wW <br />w <br />U <br />� <br />FINISH <br />O <br />GRADE <br />U <br />\ X A /\\/\\/\\\ <br />Q //\/ <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED RI FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />(1) #4 OR #5 CONT. <br />36" MAX <br />VARIES PER <br />ARCH PLANS <br />X/��// <br />12" MIN <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />3'/z' CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />MINIM <br />24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />° ° <br />VAPOR BARRIER <br />✓/ <br />FOOTING TO BEAR ON FIRM <br />• j <br />UNDISTURBED SOIL <br />b <br />12" UNDER 1 STORY WALL W/ (2) <br />ADDITIONAL NO.4 OR NO. 5 #4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL W/ (3) <br />'#4 OR (2) #5 CONT <br />1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />'NOTE': IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />E <br />ft� c <br />U <br />\\ \\ \\ \\ \\ \\ o o CLADDING - MIN 8", U.N.O. ON ARCH 00 0 <br />VAPOR BARRIER \�\\\/\\/CN <br />/\\\\\/\ A P E X <br />12 MIN \/\/\/\/\/\� N U <br />FOOTING TO BEAR ON ' <br />FIRM UNDISTURBED 6 OPT. EXTENSION IN BRICK <br />SOIL LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ (( i <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J <br />BAR IN BRICK LEDGE Li_ <br />16" UNDER 2 STORY WALL w/ <br />(2) #5 OR (3) #4 CONTINUOUS W <br />J tds J-6 <br />� <br />true design studies <br />1 MONOLITHIC FOOTING SECTION z <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE O <br />FOLLOWING OCCUR: U) <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. a) <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. O <br />O -s <br />CONCRETE SLAB w/ 6x6 � <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR LU <br />FIBERMESH <br />D#R*HO90N' a) <br />A ° ° p <br />LLI <br />/ 16" VAPOR BARRIER Q <br />U <br />3 BEARING WALL FOOTING SECTION z <br />W <br />wThis item has been electronically <br />CONCRETE SLAB W/ 6x6 signed and sealed by Justin M Lanier, <br />W1.4 x WSL B WWF x6 0' PE on the date and/or time stamp <br />shown using a digital signature. <br />FIBERMESH p Printed copies of this document are <br />_ 0'-0" A.F.F. O not considered signed and sealed <br />° SEE ARCH 0) and the signature must be verified <br />a DETAILS a 3rd Party Certificate Authority <br />d ° >.by <br />on any electronic copy <br />8" MIN ~ <br />O Q U) <br />\� Z W <br />8"x8" THICKENED 8" U) <br />FTG AT U) I..L <br />STEP-DOWN, SEE VAPOR BARRIER LU L.L <br />PLAN z z W <br />(4)CURB STEP SECTION m Uj O W <br />ct <br />W QW <br />8" UNDER MASONRY WALL Z_ <br />6" UNDER WOOD WALL z Uj Q <br />CONCRETE SLAB W/ Z � � Q <br />6x6 W1.4 x W1.4 WWF W 0 <br />OR FIBERMESH W <br />VARIES SEE ARCH � Q J � 2 <br />d - ° (MAX 16") - <br />LL <br />VAPOR BARRIER �// O <br />0 <br />/ 6" OPT. EXTENSION IN BRICK W <br />LOCATIONS ON FND PLAN d Z <br />12" UNDER 1 STORY WALL w/ <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 O LL <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL w/ Q W <br />(2) #5 OR (3) #4 CONTINUOUS J <br />� Abbott Park Q <br />5 )GARAGEEXT WALL CURB SECTION 0 <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE ILL <br />LOT 026-02 0 <br />FOLLOWING OCCUR: - <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U Q <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Z Z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY — U' <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. W <br />PROJECT NO: W <br />CONCRETE SLAB W/ 6x6 0 2021.009235 <br />W1.4 x W1.4 WWF OR 0 ILL <br />FIBERMESH Z O <br />0'-0" A.F.F. = DRAWN: 8 <br />° SEE ARCH U JAR <br />4 DEEP) 0 W O <br />° d ° � CHKD: <br />W W <br />/ • ° 4„ W J <br />4" EXTENSION x U <br />UNDER BRICK VENEER Q ��%` 111 111111 '�i Cn <br />12" UNDER 1 STORY WALL�•• • • �Z <br />W/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m ,-\G E N S�•.,• �!,' <br />0 No 85166 <br />16" UNDER 2 STORY WALL W <br />W/ (3) #4 OR (2) #5 CONT Z * ; DocuSigned by: •• * Q <br />0 � -p • �`>:..w : CC � LPL <br />6 BEARING CURB STEP SECTION =-33 TLZ71C&FEF43 4/, <br />W <br />Q i�F • •.0R� • Cj �� Z_ <br />Z et; &�O • `J `%% <br />0 <br />I i <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS j <br />11 <br />— - — - — — - <br />f_--- - <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />SEE NOTES (MAX 16") <br />U <br />0 <br />STUCCO OR DIRECTLY ADHERED <br />STONE CLADDING FINISH - MIN 6" rn <br />ALL OTHER EXTERIOR WALL `" <br />N A� %%%� > <br />Q <br />O_ 07-28-2021 0 <br />W <br />U REVISIONS: ILLI <br />U- � <br />4 No. Description Date W <br />(n J <br />Q <br />U) <br />0 <br />O O <br />Z Z <br />2 0 <br />U <br />W <br />X W ST=2mD <br />IZ <br />CMU/METAL CONNECTOR ENGINEERING <br />