Laserfiche WebLink
_)ocuSign Envelope lD:12B06693-F413-4080-990E-97E259316259 <br />__W_ <br />VII <br />TRUSS TO TOP PLATE, MOISTURE BARRIER---/ <br />UNO: BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT NON -PT LUMBER BY OTHERS <br />W/ H8 OR H10 <br />• TRUSS LENGTH </ 10 FT VERT. REINFORCING TO <br />W/ H2.5T OR RT7AT OR HAVE 10" STANDARD <br />SDWC15600 HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1 <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 �" IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />(1) COURSE CMU BOND <br />BEAM W/ #5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL WJ <br />VERTICAL WALL REINFORCING <br />2x_ NO. SPF OR BETTER @ MAX 16" O.C. <br />I ( <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />BOTTOM PLT ANCHOR <br />a <br />'/i' THREADED ROD ANCHOR W/ MIN 4" <br />¢ <br />PROVIDE DOWELS TO MATCH <br />EMBED W/ NUT & WASHER IN SIMPSON <br />o I' <br />VERTICAL WALL <br />ACRYLIC TIE OR EQUIVALENT <br />z <br />REINFORCING W/ MIN 30" LAP <br />ADHESIVE @ MAX 48" O.C. <br />(IF DOWEL IS OMITTED <br />IMPROPERLY INSTALLED, <br />OR <br />DRILL AND EPDXY DOWEL OF <br />'/z' WEDGE BOLT W/ MIN 4'/2" EMBED W/ <br />EQUAL SIZE W/ MIN. 6" <br />WASHER @ MAX 48" O.C. <br />I I <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />a <br />\ <br />BOTTOM PLATE ANCHOR NOTES <br />■ EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />■ INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />\� \ ° \ <br />a d I I \\/\\/\ <br />\\ •— < a \\\\\\ <br />a <br />VAAVA VA VA VAA/VAA��A/ <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />ROOF-1 <br />COW <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />FOR MISLOCATIO <br />3/4" BETWEEN TOP OF WOOD PANEL <br />FASTEN 2x6 NO. 2 <br />AND CENTER OF FASTENERS. <br />TO TRUSS W/ MIN I <br />MIN 1%2" EXPOSURE 1 PLYWOOD RIM @ RAISED <br />FOR MISLOCATIO <br />HEEL TRUSSES INSTALLED WITH LONG <br />INSTALL NEW MAE <br />DIMENSION PERPENDICULAR TO TRUSS END <br />STRAP TO INSIDE <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />a <br />Q <br />J <br />Lr> <br />N <br />Z <br />2 <br />(1) #4 OR #5 BAR AT CORNERS <br />WITH MIN. 25" LAP <br />#5 CONT. <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />GENERAL NOTES APPLICABLE TO ALL: <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />(1)#F <br />POURED CELL w #5 BAR CONT <br />FROM BEAM TO FOOTING <br />STEP DOWN TIE -BEAM <br />U <br />0 <br />N <br />0 <br />N <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH <br />/ WINDOW TO BLOCK <br />LENGTH <br />OR 1%4" <br />PER MANUF. <br />3" <br />5" <br />11/2' <br />3%4" <br />37/I6 <br />5" <br />115,16 <br />1 33/4 <br />3 34" <br />6„ <br />2 <br />3 3/4, <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWS %" DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS 3/6' DIA. @ 24" O.C. STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1x_ PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />° <br />JAMB OR WINDOW, SEE TABLE <br />0 <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED <br />1x_ PT NAILER <br />BUILT UP 2x_ ATTACHED TO MASONRY, (1) PLY <br />1 x_ OR �6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DOOR/VVINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />U <br />O <br />O <br />N O <br />N <br />APEX <br />U <br />O N <br />'J <br />r <br />N <br />M � <br />CID <br />J � <br />LL -C <br />W <br />J tds <br />J � <br />true design studios <br />Z <br />O <br />U 9000 REGENCY SQUARE BLVD. <br />Q SUITE 100, JACKSONVILLE, FL 32211 <br />0 <br />O <br />W <br />0 <br />> m a a `$ \ <br />_j <br />s��W, <br />a <br />w <br />Q � <br />U <br />W <br />W This item has been electronically <br />signed and sealed by Justin M Lanier, <br />W PE on the date and/or time stamp <br />O shown using a digital signature. <br />O Printed copies of this document are <br />O not considered signed and sealed <br />O and the signature must be verified <br />by a 3rd Party Certificate Authority <br />�on any electronic copy <br />U w <br />p� Q - <br />W 0. <br />J z w <br />LJJ O cr) <br />W <br />W Q <br />W <br />Z_ <br />3 > 0 a <br />w m w 0 <br />o LLI W <br />Q W <br />w <br />OJ d' X <br />z �— <br />O ZO <br />F_ <br />Q 0 <br />W W <br />a z <br />O a <br />U W <br />Q - <br />0 W <br />o Abbott Park v <br />J W <br />LL LOT 026-02 0 <br />Q W <br />U Q <br />Z_ Z <br />} CD <br />C� U) <br />O PROJECT NO: W <br />j 2021.009235 0 <br />Z O <br />DRAWN: <br />U JAR o <br />W CHKD: L0 <br />MJP <br />x <br />W W <br />Q U <br />Q%`���������rr�i to <br />W <br />No 85166 <br />Z ,. * � DocuSigned by: •• �- � QN <br />i �0 •ZTLE710EF43 * i1i <br />sS;o N a� ti; a <br />O 07-28-2021 0 <br />F_ W <br />v REVISIONS: <br />Q No. Description Date ~ <br />W <br />U) j <br />O Z <br />U <br />W <br />F- <br />X <br />W ST=5 <br />d <br />CMUIMETAL CONNECTOR ENGINEERING <br />