DocuSign Envelope ID: 5053F29C-8B9D-49A9-95BD-E5A5314E3C81 <br />EXISTING EXTERIOR CMU <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO — <br />MIN. 6" BELOW GRADE. WWF TO _ <br />EXISTING FOUNDATION FACE w/ ° p <br />(2) ROWS OF 3/s' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER p ° <br />FLUSH w/ 3000psi CONCRETE. <br />° EXISTING FOUNDATION. <br />I � ° <br />D \ <br />n ° <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />° <br />��— —z­ — — — <br />„ <br />0 <br />4 <br />DEEP) <br />//\ O d <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL I <br />VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />6 BEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />d ° ° <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />NO.5 BAR BEND 90 DEGREE <br />TOP OF FOOTING <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL, <br />GROUT BOTTOM 3 COURSES d <br />OF EXISTING CMU WALL FOR _ <br />LENGTH OF OVERHANG. FILL - <br />TO BOTTOM OF WINDOW SILL <br />CMU STEMWALL MONO LITHIC SLAB <br />WHERE NEEDED <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS <br />TO EXTEND MIN 24" <br />- <br />INTO MONOLITHIC THICKENED EDGE <br />MIN 24" LAP <br />MIN. 3" EDGE DISTANCE <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 <br />STRIP OF WWF FROM F.F.E. TO <br />— _ _ <br />_� _ <_ OR FIBER ESHF <br />BOTTOM OF FTG. WWF TO <br />cn <br />-----------d— <br />-------^---• <br />EXISTING FOUNDATION FACE w/ ° — <br />h� D D D D ° D D <br />w Z <br />co 0 <br />°< d ° $, ° °d <br />3 / <br />(2) ROWS OF /6 DIA. TAPCONS <br />x <br />#4 OR #5 <br />REINFORCING PER <br />OR CUT NAILS @ 24" O.C. COVER ° <br />O <br />Z4 <br />d ° ° ° ° <br />° <br />FLUSH w/ 3000psi CONCRETE. „ i <br />U <br />M <br />° MONOLITHIC FOOTING <br />• d < <br />d SECTION <br />EXISTING FOUNDATION <br />° • ° ° ` ° ° <br />FOOTING TO BEAR ON FIRM <br />\\ <br />° d ° <br />_ UNDISTURBED SOIL <br />° \ <br />• d • d <br />°° d° • MIN 112" <br />\ ° <br />° <br />N//\\/\\//\\ <br />8 CMU WALL OVERHANGS 2.5 OR LESS <br />•STEMWALL FOOTING TOEXTEND MIN <br />\j\�\j�\j\�%��j/\\/\j�\\�\�/ <br />12" BELOW MONOLITHIC FOOTING <br />/ / / / <br />NOTES: <br />\j�\\i�\\��\� <br />/' /' <br />• ADDITIONAL #4 OR #5 VERTICAL TO BE <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />LOCATED WITHIN TRANSITION ZONE <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />LOCATE <br />REINFORCEMENT IN LAST <br />AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />STEMWALL CELL <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESHA /,-- <br />8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />QQ <br />O <br />VAPOR BARRIER �\\ <br />LJ <br />� <br />o LO <br />X <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C.. <br />4 TO 5 COURSES: 48" O.C. <br />\ <br />��\\/ ADDITIONAL #4 OR <br />FOOTING TO BEAR ON FIRM ' . //� / #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. __ <br />(BEYOND) <br />FLOATING CONCRETE — w U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 ¢ v J (1) #4 OR #5 <br />WWF OR FIBERMESH > Q Q rn CONT <br />y F W <br />— — � U) R <br />FINISH <br />/ / O GRADE <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL -- ADDITIONAL #4 OR <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO <br />HAVE 6" BEND @ BOTTOM N OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />TSTEMW <br />ALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />(1) #4 OR #5 CONT. <br />36" MAX VARIES PER <br />___\ ARCH PLANS <br />12" MIN` <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />3'/z" CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />d a VAPOR BARRIER <br />FOOTING TO BEAR ON FIRM <br />° • / UNDISTURBED SOIL <br />b I <br />ADDITIONAL NO. 4 OR NO. 5 #4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL W/ (3 <br />�-� #4 OR (2) #5 CONT - <br />l �I /�1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />`NOTE`: IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 SEE NOTES (MAX 16")U <br />W1.4 x W1.4 WWF OR <br />o <br />FIBERMESH STUCCO OR DIRECTLY ADHERED <br />STONE CLADDING FINISH - MIN 6" <br />rn <br />AM <br />O <br />U <br />--- --o <br />N <br />> <br />ALL OTHER EXTERIOR WALL 0i <br />\\\\\\\\\\\\ \\\\\ o o D CLADDING - MIN 8", U.N.O. ON ARCH O O <br />/../j/,//, /i /i\/� ///\ <br />VAPOR BARRIER APEX <br />o 12MN//// N rJ <br />00 <br />FOOTING TO BEAR ON 6 OPT. EXTENSION IN BRICK �— <br />FIRM UNDISTURBEDSOIL LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ M <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J <br />BAR IN BRICK LEDGE LL g <br />16" UNDER 2 STORY WALL w/ L 1 <br />(2) #5 OR (3) #4 CONTINUOUS Jtds Q <br />J true design studios (D(D <br />1 MONOLITHIC FOOTING SECTION _ z <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE O <br />FOLLOWING OCCUR: U) <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 <br />FROM STRUCTURE STEEPER THAN T-0" VERTICALLY O <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. O <br />O � <br />CONCRETE SLAB w/ 6x6 ` <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR W <br />FIBERMESH <br />---°-- — 9 — °— ° --- a — — 014HOMN" <br />_j <br />120 <br />16" VAPOR BARRIER Q <br />0 <br />U) <br />3 BEARING WALL FOOTING SECTION U <br />z <br />W <br />(D <br />W <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR O This item has been electronically <br />FIBERMESH 0 signed and sealed by Justin M Lanier, <br />0'-0" A.F.F. O PE on the date and/or time stamp <br />° CF) shown using a digital signature. <br />SEE ARCH Printed copies of this document are <br />° d DETAILS not considered signed and sealed <br />\ <br />, °— � ---° � >Mand the signature must be verified <br />by a 3rd Party Certificate Authority <br />8" MIN n any electronic copy O W I <br />z LLI <br />8"x8" THICKENED 8" W <br />FTG AT U) n/ <br />STEP-DOWN, SEE VAPOR BARRIER W LL.LL <br />PLAN z z Lu <br />4 CURB STEP SECTION m Uj _O W <br />W <br />W QW <br />8" UNDER MASONRY WALL Z_ < O <br />6" UNDER WOOD WALL z Uj Q Q <br />CONCRETE SLAB W/ Z Uj <br />6x6 W1.4 x W1.4 WWF W LLI <br />W 0 <br />OR FIBERMESH VARIES��A <br />SEE ARCH Q J � �d(MAX 16") W W/ f� <br />I..L <br />\/\ LLLL <br />\/\ d � X 12" MIN \\/\\/\\/\\/\Z <br />/\\\/\\\\/\\\\\ Q Z <br />VAPOR BARRIER <br />Q <br />6" OPT. EXTENSION IN BRICK 0 N <br />LOCATIONS ON FND PLAN IZ z <br />12" UNDER 1 STORY WALL w/ <br />O a_ <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 U LL <br />BAR IN BRICK LEDGE — <br />16" UNDER 2 STORY WALL w/ ¢ W <br />(2) #5 OR (3) #4 CONTINUOUS J <br />Abbott Park Q <br />5 GARAGE EXT WALL CURB SECTION__— O <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE LL LOT 033-02 0 <br />FOLLOWING OCCUR: - LLJ <br />— <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" b Q <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY z z <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY (D <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. (n <br />PROJECT NO: LLI <br />CONCRETE SLAB W/ 6x6 O 2021.011079 0 <br />W1.4 x W1.4 WWF OR O LL <br />FIBERMESH Z DRAWN: O <br />0'-0" A.F.F. _ <br />SEE ARCH U JAR 801 <br />--d—a — — — — (MAX 20" W O <br />° d d — — — DEEP) CHID <br />° U <br />° d MJP <br />W W <br />d J <br />4" EXTENSION <br />UNDER BRICK VENEER Q ���,�IN 1 L�q v,,�� U <br />% <br />12" UNDER 1 STORY WALL } �%��G E•N •h�� z <br />W/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m : • �SF••,. _ <br />0 No 85166 <br />16" UNDER 2 STORY WALL W Q <br />w/ (3) #4 OR (2) #5 CONT j = * Docu;S'gned by: •• * - LL <br />6 BEARING CURB STEP SECTION AP W 3f'46FfDF435.. <br />i I I <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />—_ ------------ <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />Q <br />_O 09-16-2021 elf <br />� W <br />U REVISIONS: <br />U <br />Q No. Description Date <br />U) Q <br />O <br />O z <br />2 0 <br />U <br />W <br />x <br />W ST=2mD <br />d <br />CMU/METAL CONNECTOR ENGINEERING <br />