Laserfiche WebLink
I' I1 II I f 1- +JIB I i I <br />�., elope ID 5053F29C-889D-49A9-95BD-E5A5314E3C81 <br />TRUSS TO TOP PLATE, MOISTURE BARRIER <br />UNO: BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT NON -PT LUMBER BY OTHERS <br />W/ H8 OR H10 <br />• TRUSS LENGTH </ 10 FT VERT. REINFORCING TO --/ <br />W/ H2.5T OR RT7AT OR HAVE 10" STANDARD <br />SDWC15600 HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32"O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1 <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 Y2' IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1 <br />(1) COURSE CMU BOND <br />BEAM W/ #5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x_ NO. SPF OR BETTER @ MAX 16" O.0 <br />'/i' THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />Y2" WEDGE BOLT W/ MIN 4'/z" EMBED W/ <br />WASHER @ MAX 48" O.C. <br />BOTTOM PLATE ANCHOR NOTES <br />'EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />• INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />ROOF -- <br />COW <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />FOR MISLOCATIW <br />3/4" BETWEEN TOP OF WOOD PANEL <br />FASTEN 2x6 NO. 2 S <br />AND CENTER OF FASTENERS. <br />TO TRUSS W/ MIN (' <br />MIN'%32" EXPOSURE 1 PLYWOOD RIM @ RAISED <br />FOR MISLOCATIOI\ <br />HEEL TRUSSES INSTALLED WITH LONG <br />INSTALL NEW MAS! <br />DIMENSION PERPENDICULAR TO TRUSS END <br />STRAP TO INSIDE F <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 12" <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />2 <br />(1) #4 OR #5 BAR AT CORNERS <br />WITH MIN. 25" LAP <br />#5 CONT. <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />GENERAL NOTES APPLICABLE TO ALL: <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />I <br />POURED CELL w #5 BAR CONT <br />FROM BEAM TO FOOTING <br />STEP DOWN TIE -BEAM <br />U <br />0 <br />N <br />N <br />N <br />DIST. FROM DOORJAMB <br />MIN. SCREW <br />DIST. FROM DOORJAMB <br />MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH <br />/ WINDOW TO BLOCK <br />LENGTH <br />OR 1%4' <br />PER MANUF. <br />3" <br />5" <br />11/y <br />3�4' <br />37�6 <br />5„ <br />115/ 6 <br />33/4" <br />3 3/ " <br />6„ <br />2 /4, <br />33/4' <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWS %" DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS 3/6" DIA. @ 24" O.C. STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1x_ PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />o <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED 'W) <br />1x_ PT NAILER <br />BUILT UP 2X_ATTACHED TO MASONRY, (1) PLY <br />1 x_ OR �6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DOORMINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />o <br />U <br />O <br />O OI <br />N APE <br />� <br />00 <br />O <br />O flJ <br />N <br />co <br />_j <br />LL •-�' <br />W <br />J Q <br />J � <br />true design studios <br />Z <br />O <br />U 9000 REGENCY SQUARE BLVD. <br />Q SUITE 100, JACKSONVILLE, FL 32211, <br />0 <br />�i <br />O <br />W <br />DIH0190N' <br />o <br />120 <br />W <br />0 <br />(D <br />Z <br />W <br />W <br />x <br />This item has been electronically <br />O signed and sealed by Justin M Lanier, <br />C:) PE on the date and/or time stamp <br />O shown using a digital signature. <br />Printed copies of this document are <br />not considered signed and sealed <br />nd the signature must be verified <br />by a 3rd Party Certificate Authority <br />O Qon any electronic copy v / <br />Z <br />W <br />W <br />z J z LU <br />LLj O co <br />m <br />� Q <br />W <br />W <br />Z_ <br />z > Q Q <br />LU m LU 0 <br />� J W <br />(r W ti <br />OLL <br />LL <br />�" X <br />z <br />Z Z <br />O O <br />Q 0 <br />Ir w <br />a z <br />o a- <br />U LL <br />Q W <br />0 J <br />Abbott Park Q <br />O U <br />J (n <br />LL LOT 033-02 0 <br />Q W <br />U Q <br />_Z Z <br />} (D <br />C7 CO <br />O PROJECT NO: W <br />—1 2021.011079 0 <br />O u- <br />Z DRAWN: O <br />U JAR o <br />W U-)CHKD: <br />MJP <br />x <br />W W <br />a J <br />Q U <br />Q cn <br />%.� JS�(iN LAN�� U) <br />No 85166 <br />- Q <br />Z DocuSigned by: •• <br />O - pp � <br />W O •• .. 3P4� ADE F435. • /,V` U) <br />I�I�t Q <br />O 09-16-2021 p <br />1- W <br />U REVISIONS: <br />Q No. Description Date ~ <br />W <br />U) J <br />' Q <br />0 JU) <br />O <br />z z <br />= o <br />U <br />W <br />H <br />X <br />W ST=5 <br />w <br />CMUIMETAL CONNECTOR ENGINEERINGa <br />