Laserfiche WebLink
DocuSign Envelope ID: 5053F29C-8B9D-49A9-95BD-E5A5314E3C81 <br />DESIGN CRITERIA AND LOADS <br />TABLE 7: METAL CONNECTOR SCHEDULE <br />NOTFS 9 '1 4 <br />Building Code <br />Florida Building and Residential Codes . <br />7ch Edition (2020) <br />Code for Design Loads <br />ANSI/ASCE 7-16 <br />ROOF LOADING' ............................................... <br />Cd = 1.25 <br />TOP CHORD LIVE LOAD .................................. <br />20 PSF <br />TOP CHORD DEAD LOAD................................7 <br />PSF (TILE = 15 PSF) <br />BOTTOM CHORD LIVE LOAD <br />ATTICS WITH LIMITED STORAGE ............... <br />20 PSF <br />ATTICS WITHOUT STORAGE.., .................... <br />10 PSF <br />(NON -CONCURRENT) <br />BOTTOM CHORD DEAD LOAD.......... <br />5 PSF <br />WIND LOADING ................................................. <br />Cd 1.60 <br />ASCE 7-16, 3S GUST........................................139 <br />MPH <br />BASIC WIND SPEED <br />EXPOSURE CATEGORY..................................0 <br />,BUILDING CATEGORY.....................................II <br />ENCLOSURE CLASSIFICATION ..... ............. <br />..-ENCLOSED <br />INTERNAL PRESSURE COEFF.......................0 <br />18 <br />C&C DESIGN PRESSURES ..... ......_._........__..(SEE <br />TABLE 1) <br />FLOOR LOADING... .... . ..... ......... ... .. <br />. ....... Cd = 1.00 <br />TOP CHORD LIVE LOAD..................................40 <br />PSF <br />TOP CHORD DEAD LOAD................................10 <br />PSF <br />BOTTOM CHORD LIVE LOAD .......................... <br />0 PSF <br />BOTTOM CHORD DEAD LOAD........................5 <br />PSF <br />SPECIAL FLOOR (GAME ROOM) LOADING- ...Cd = 1.00 <br />CHORD <br />LIVE O TOP H E LOAD ..................................60 <br />PSF <br />TOP CHORD DEAD LOAD...............................10 <br />PSF <br />BOTTOM CHORD LIVE LOAD ...........................0 <br />PSF <br />BOTTOM CHORD DEAD LOAD ........................ <br />5 PSF <br />MAXIMUM FLOOR TRUSS SPACING...............16" <br />O.C. <br />DEFLECTION CRITERIA <br />LL / 240 <br />ROOF TRUSSES .............................................. <br />TL / 180 <br />TL MAX 1" UP TO 40' SPAN <br />LL / 480 <br />TL / 360 <br />OPEN WEB FLOOR TRUSSES ...................... <br />LL / 480 <br />TL/240 <br />WOOD I JOISTS ............................................... <br />TL MAX 1/2„ <br />LL/360 <br />BEAMS' .............................................. <br />TL / 240 <br />NOTES: <br />1. PORCH BEAMS AND BEAMS SUPPUK I ING EX I EKIUK WALL <br />ABOVE SHALL NOT EXCEED 3/4" DEFLECTION <br />TABLE 1: COMPONENT AND <br />CLADDING DESIGN PRESSURES <br />WINDOWS AND DOORS <br />EFFECTIVE <br />WIND AREA <br />ZONE DESIGNATION <br />IZ - Interior Zone (psf) <br />EZ - End Zone (psf) <br />0-20 ft2 <br />+28.54 -30.96 <br />+28.54 <br />-38.22 <br />21 - 50 ft2 <br />+27.17 -29.59 <br />+27.17 <br />-35.47 <br />51 - 100 ft2 <br />+25.52 -27.94 <br />+25.52 <br />-32.17 <br />101 - 200 ft2 <br />+24.25 -26.67 <br />+24.25 <br />-29.64 <br />SOFFIT MAX PRESSURE (psf) <br />+ 28.6 <br />- 38.3 <br />GARAGE DOOR PRESSURE <br />+21.7 <br />-24.6 <br />END ZONE KEY MAP <br />END ZONE: END ZONES SHALL BE TAKEN <br />AS THE 1ST 4.0' PER FIGURE R301.2 (7) <br />I <br />Ll <br />I <br />i <br />i <br />1 ST FLOOR (TYP) <br />END ZONE <br />DESIGNATION <br />TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS <br />NOTF.q� 4 <br />p O <br />z <br />STUCCO AND DIRECTLY <br />MIN 1%2" 32/16 SPAN RATED OSB OR PLYWOOD INSTALLED VERTICALLY OR ('/6" 24/16 <br />ADHERED STONE <br />INSTALLED HORIZONTALLY) W/ 8d COMMON: 6" O.C. AT PANEL EDGES, 12" O.C. IN THE <br />Lu N <br />Q <br />(NOTE 6) <br />FIELD. 2x4 BLOCKING IS RECOMMENDED AT UNSUPPORTED PANEL EDGES. <br />w=� <br />J O <br />Q z <br />U J -- <br />ALL OTHER VENEER <br />15 �� <br />B R PLYWOOD INSTALLED VERTICAL OR HORIZONTAL <br />MIN /32 32/16 SPAN RATED OS O 00 C <br />aQ <br />(NOTE 8) <br />W/ 8d COMMON: 6" O.C. EDGES AND FIELD (UNBLOCKED HORIZONTAL PANEL EDGES); <br />> <br />6" O.C. AT PANEL EDGES, 6" O.C. IN FIELD (BLOCKED HORIZONTAL PANEL EDGES) <br />x (D 6 <br />TILE AND METAL ROOF <br />MIN 1%2" 32/16 SPAN RATED PLYWOOD INSTALLED WITH LONG DIMENSION <br />oa <br />(NOTE 7) <br />PERPENDICULAR TO SUPPORTS W/ RSRS-01 NAILS: 4" O.C. AT PANEL EDGES AND <br />o <br />6" O.C. IN THE FIELD <br />LL 0 w � <br />MIN'/16" 24/16 SPAN RATED OSB OR PLYWOOD INSTALLED WITH LONG DIMENSION <br />O = O <br />U z <br />SHINGLE ROOF <br />PERPENDICULAR TO SUPPORTS W/ RSRS-01 NAILS: 6" O.C. AT PANEL EDGES, 6" <br />O.C. IN THE FIELD. <br />FLOOR DECK SHEATHING: <br />23/32" T&G OSB OR PLYWOOD W/ 10d COMMON: 6" O.0 AT PANEL EDGES, 12" O.C. IN THE <br />(NOTE 5) <br />FIELD. <br />MIN %/ OSB OR PLYWOOD OR CDX INSTALLED PERPENDICULAR TO SUPPORTS W/ 8d <br />PORCH CEILING BOARD SHEATHING: <br />COMMON: 3" O.C. AT PANEL EDGES 12" O.C. IN THE FIELD OR MIN 11/2" EXTERIOR GYPSUM <br />CEILING BOARD, FASTEN w/ 5d x 1 /8" COOLER NAIL OR NO.6 x 1'/" LONG SCREWS @ <br />4" O.C. EDGES, 8" O.C. FIELD <br />NOTES: <br />1. FOR SHEATHING THICKNESS GREATER THAN 15/32" CATEGORY, USE RSRS-03 NAILS. <br />2. COMMON NAILS IN WALL SHEATHING MAY BE SUBSTITUTED W/ 8d GALVANIZED BOX NAILS. <br />3. ZIP WALL SHEATHING IS AN ACCEPTABLE ALTERNATE FOR APA RATED WOOD STRUCTURAL PANEL. <br />4. ALL WOOD STRUCTURAL PANEL SHALL CONFORM TO THE MOST CURRENT APPLICABLE SPECIFICATION AND SUPPLEMENTS OF <br />CURRENT APPROVED APA.MANF. SPECIFICATIONS. <br />5. FLOOR FASTENERS ARE MINIMUM REQUIRED FOR DIAPHRAGM DESIGN. FOR INCREASED FLOOR PERFORMANCE AND TO <br />REDUCE SQUEAKING, RSRS-01 NAILS OR 8d SCREW NAILS ARE RECOMMENDED. <br />6. 1%2" 32/16 SPAN RATED OSB OR PLYWOOD WITH BLOCKED PANEL EDGES IS AN APA RECOMMENDATION PER APA TECHNICAL <br />BULLETIN Q370 WHEN STUCCO LATH IS ATTACHED DIRECTLY TO OSB OR PLYWOOD.. SHOULD BUILDER SPECIFICATIONS ALLOW, MIN <br />STRUCTURAL REQUIREMENTS ARE %6" 24/16 SPAN RATING INSTALLED HORIZONTALLY OR VERTICALLY PER FLEXIBLE VENEER WALL <br />SPECIFICATIONS. INCLUDES FULL AND PARTIAL HEIGHT VENEER APPLICATIONS. <br />7. 1%2" PLYWOOD IS A WARRANTY LIMITATION COMMON TO TILE MANUFACTURER'S MINIMUM RECOMMENDATIONS. SHOULD WARRANTY <br />AND INSTALLATION REQUIREMENTS ALLOW, 15/32" APA RATED OSB OR EQUAL MAY BE USED TO SUPPORT TILE ROOF. <br />8. WOOD STRUCTURAL PANEL MAY BE INSTALLED VERTICALLY OR HORIZONTALLY W/ UNBLOCKED HORIZONTAL PANEL EDGES. <br />9. ROOF DECK SHEATHING HAS BEEN ENGINEERED TO RESIST ASCE 7-16 WIND LOADS IN ACCORDANCE WITH FRC R301.2.2.1 <br />TABLE 4: NAIL SIZE LEGEND TABLE 5: FASTENERS IN <br />NOTES 1, 2, 3, 411 PRESSURE TREATED LUMBER <br />DIAMETER <br />LENGTH <br />8d COMMON <br />0.131" <br />2-'/2" <br />RSRS-01 <br />0.113" <br />2 %" <br />RSRS-03 <br />0.131" <br />2-'/2" <br />10d <br />0.131" <br />3" <br />10d COMMON <br />0.148" <br />3" <br />12d COMMON <br />0.148" <br />3-'/4" <br />16d SINKER <br />0.148" <br />3-%" <br />16d COMMON <br />0.162" <br />3-'/2" <br />PRESERVATIVE <br />FASTENER TYPE <br />ACZA <br />STANDARD CARBON STEEL <br />SODIUM BORATE (NOTE 1) <br />STAINLESS CONNECTORS AND <br />FASTENERS REQUIRED. <br />CONNECTORS MUST HAVE <br />Z-MAX, G120 OR TRIPLE ZINC <br />ALL OTHER PT <br />COATED FINISH. <br />(INCLUDING ACQ & MCQ) <br />ALL FASTENERS MUST BE HOT <br />DIPPED GALVANIZED. <br />NOTES: <br />1. INSTALL 10d NAILS UNLESS OTHERWISE SPECIFIED. <br />NOTES: <br />2. COMMON WIRE NAILS AND THREADED HARDENED STEEL NAILS <br />1 SILL PLATES W/ SODIUM BORATE TREATMENTS BEARING ON <br />SHALL CONFORM TO THE NOMINAL SIZES SPECIFIED IN ASTM <br />CONCRETE OVER VAPOR BARRIER ARE NOT DIRECTLY <br />F1667. NOMINAL DIAMETER SIZES APPLY TO FASTENERS <br />EXPOSED TO EARTH OR WEATHER AND HAVE BEEN PROVEN <br />BEFORE APPLICATION OF PROTECTIVE COATING. <br />TO BE NON -CORROSIVE TO CARBON STEEL FASTENERS. <br />3. WHEN A BORED HOLE IS REQUIRED TO PREVENT SPLITTING OF <br />A WOOD DUE TO FASTENER PENETRATION. THE BORED HOLE <br />SHALL NOT EXCEED 75% OF THE NAIL OR SPIKE DIAMETER. <br />4. THE NOMINAL DIAMETER AND LENGTH OF TYPICAL FASTENERS <br />SPECIFIED FOR THIS PROJECT ARE AS LISTED IN TABLE 4. <br />CONCRETE AND FOUNDATION NOTES <br />1. CONCRETE COMPRESSIVE STRENGTH FOR FOOTINGS= 2,500 PSI AT 28 DAYS (UNO). <br />2. CONCRETE COMPRESSIVE STRENGTH FOR SLAB = 2,500 PSI AT 28 DAYS (UNO). <br />3. ALL REINFORCING STEEL #3 AND BIGGER SHALL BE ASTM A615 GRADE 40 DEFORMED BARS (UNO). <br />4. ALL REINFORCING STEEL SHALL HAVE 90 DEGREE BEND AT CORNERS WITH A 24" LAP. 24" LONG #4 BAR IS RECOMMENDED TO BE <br />INSTALLED AT ALL REENTRANT CORNERS. <br />5. FIBERMESH IS AN ACCEPTABLE ALTERNATIVE AND SHALL NOT REQUIRE WWF. FIBER LENGTHS SHALL BE'/2' TO 2" IN LENGTH. <br />DOSAGE AMOUNTS SHALL RANGE FROM 0.75 TO 1.5 POUNDS PER CUBIC YARD IN ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDATIONS. SYNTHETIC FIBERS SHALL COMPLY WITH ASTM C1116. THE MANUFACTURER OR SUPPLIER SHALL PROVIDE <br />CERTIFICATION OF COMPLIANCE WHEN REQUESTED BY THE BUILDING OFFICIAL. <br />6. MASONRY STEMWALL AND MONOLITHIC FOOTING ARE INTERCHANGEABLE. <br />7. EARTH AND EARTH FILL SUPPORTING SLABS ON GRADE IS ASSUMED TO HAVE A MINIMUM BEARING CAPACITY OF 2,000 PSF IN <br />ACCORDANCE WITH TABLE R401.4.1. AND SHALL BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS. <br />COMPACT THE FILL IN 12" LIFTS TO AT LEAST 95% OF MODIFIED PROCTOR MAXIMUM DRY DENSITY, IT IS THE OWNER'S OR <br />CONTRACTOR'S RESPONSIBILITY TO CONFIRM THESE ASSUMPTIONS. <br />8. CONCRETE FLOOR SLABS ON GRADE SHALL BE INSTALLED OVER A MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER WITH <br />JOINTS LAPPED 6" AND SEALED OVER CLEAN, COMPACTED EARTH OR FILL WITH CODE APPROVED PROVISIONS FOR <br />PREVENTION OF SUBTERRANEAN TERMITES. <br />9. STEMWALLS OVER 4 COURSES TALL REQUIRE SPECIAL ATTENTION TO BRACING DURING CONSTRUCTION. CONTACT ENGINEER <br />OF RECORD IF THIS CONDITION EXISTS. <br />10. TO CONTROL CRACKING, CUT 1" SAWCUTS IN THE SLAB IN A 15'x15' GRID WITHIN 12 HOURS OF CONCRETE PLACEMENT. <br />CONTACT FOR FOR ALTERNATIVE METHODS. CONTROL JOINTS ARE NOT REQUIRED WHEN WWF OR FIBERMESH ARE INCLUDED <br />WITH CONCRETE WORK. <br />11. DO NOT SCALE FOOTING DIMENSIONS AND LOCATIONS FROM THE FOUNDATION PLAN. DO NOT DETERMINE FOOTING LOCATION <br />FROM ARCHITECTURAL PLANS OR FRAMING PLAN. IF FOOTING SIZE OR LOCATION IS NOT DETERMINATE FROM USE OF <br />FOUNDATION PLAN ALONE, CONTACT THE ENGINEER OF RECORD. <br />PRE-ENGINEERED TRUSSES & I -JOISTS <br />1. ROOF TRUSS TOP CHORDS SHALL HAVE A MINIMUM SPECIFIC GRAVITY OF 0.49 (SYP SPECIES OR BETTER). <br />2. ROOF OR FLOOR TRUSSES FABRICATED TO ACHIEVE THE ROOF PLANES DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE <br />DESIGNED UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER. ENGINEERING SHOP DRAWINGS <br />SHALL BE PREPARED IN ACCORDANCE WITH ANSI/TPI AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO <br />FABRICATION. DESIGN CRITERIA IS LOCATED ON SHEET ST-1 OF THE PLAN SET. TEMPORARY BRACING SHALL BE THE <br />RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE LEFT IN PLACE AFTER CONSTRUCTION IS COMPLETE. <br />3. TRUSSES OR I -JOISTS SHALL BE DESIGNED TO MATCH THE ORIENTATION, SPAN DIRECTION, SPACING, BEARING LOCATION AND <br />NAMING CONVENTION OF THE LAYOUT SHOWN HERE. <br />4. THE TRUSS ENGINEER SHALL PROVIDE ALL TRUSS TO TRUSS CONNECTION DESIGN AND SPECIFICATIONS AND SUBMIT THEM <br />UNDER SIGN AND SEAL WITH THE TRUSS SHOP DRAWINGS. <br />5. TRUSS UPLIFTS HAVE BEEN CALCULATED BY THE ENGINEER OF RECORD AND TAKEN INTO CONSIDERATION DURING THE DESIGN <br />OF THE UPLIFT RESTRAINT SYSTEM FOR THIS STRUCTURE. AS SUCH, THE REPORTED UPLIFTS ON THE TRUSS SHOP DRAWINGS <br />MAY BE DISREGARDED. <br />6. I -JOISTS FABRICATED TO ACHIEVE THE FLOOR PLANS DEPICTED ON THE ARCHITECTURAL PLANS SHALL BE DESIGNED AND <br />SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. SEE DESIGN CRITERIA, <br />THIS SHEET. <br />USP & SIMPSON CONNECTORS IN CORRESPONDING ROWS BELOW ARE EQUAL <br />ALTERNATIVES AND MAY BE CONSIDERED INTERCHANGEABLE <br />SIMPSON <br />SIMPSON FASTENERS <br />MITEK <br />USP FASTENERS <br />SIMPSON <br />SIMPSON <br />FASTENERS <br />MITEK <br />USP FASTENERS <br />(8)Y. X 1 /2 SIDS SCREWS <br />, <br />8 x 1 /2" WS15-GC <br />/<„ <br />DTT2Z <br />IN STUD'h" 0 X4 M" <br />WOOD SCREWS IN STUD <br />(9) 10d COMMON <br />(9) 10d <br />(NOTE 2) <br />EMBED EPDXY OR <br />DTB-TZ <br />Y2 0 x 4'/2" EMBED EPDXY <br />CS18 <br />EACH END <br />CS20 <br />COMMON <br />SCREW ANCHOR <br />OR SCREW ANCHOR <br />EACH END <br />(18)0.162"x2'/z"IN <br />(18)0.162"x2'/2"IN <br />HTT4 <br />STUD/BEAM/TRUSS <br />STUD/BEAM/TRUSS <br />(7) 10d x 1 'Y2" <br />(7) 10d x 1 1/2"(NOTE <br />2) <br />48" 0 x 6" EMBED ANCHOR <br />HTT45 <br />48" 0 x 6" EMBED ANCHOR <br />MTS12 <br />EACH END <br />MTW12 <br />EACH END <br />IN CONCRETE <br />IN CONCRETE <br />(26) 0.162" x 2 '/2" IN <br />(26) 0.162" x 2 W IN <br />HTT5 <br />STUD/BEAM/TRUSS <br />HTT45 <br />STUD/BEAM/TRUSS <br />MSTA24 <br />(9) 10d COMMON <br />MSTA24 <br />(9) 10d COMMON <br />(NOTE 2) <br />48" 0 x 6" EMBED ANCHOR <br />�8" 0 x 6" EMBED ANCHOR <br />EACH END <br />EACH END <br />IN CONCRETE <br />IN CONCRETE <br />(20)'/4" x 3" SIDS SCREWS <br />(24) 3" WS IN STUD <br />HDQ8-SDS3 <br />IN STUD GROUP <br />PHD8 <br />GROUP 8" 0 x 12" EMBED <br />MSTA36 <br />(13) 10d COMMON <br />MSTA36 <br />(13) 10d COMMON <br />8" 0 x 12" EMBED <br />ANCHOR IN CONCRETE <br />EACH END <br />EACH END <br />ANCHOR IN CONCRETE <br />(7) 10d COMMON IN <br />(7) 10d COMMON IN <br />(7) 10d x 1 '/2" IN TRUSS <br />(7) 10d x 1 %" IN TRUSS <br />WOOD FRAMING <br />WOOD FRAMING <br />META12 <br />4" WET EMBED IN <br />HTA16-18 <br />4" WET EMBED IN <br />MSTAM36 <br />(4) Y<" x 2 '/4" TITEN <br />MSTAM36 <br />(5) 'Y." x 2 '/4" TAPCON IN <br />GROUTED BLOCK WALL <br />GROUTED BLOCK WALL <br />SCREWS IN MASONRY <br />MASONRY <br />(8)10dx1'/2"IN TRUSS <br />(9)10dx1'/2"IN TRUSS <br />(11)10dx1'/2"IN <br />(11) 10d x 1 1/2" IN <br />META20 <br />4" WET EMBED IN <br />HTA20-18 <br />4" WET EMBED IN <br />HTS20 <br />TRUSS/RAFTER <br />HTW20 <br />TRUSS/RAFTER <br />GROUTED BLOCK WALL <br />GROUTED BLOCK WALL <br />(11) 10d x 1 '/2" IN <br />(1 1) 10d x 1 '/2" IN <br />STUD <br />STUD <br />(12) 10d x 1 '/2" IN <br />(8) 10d x 1'/2" IN <br />ABU44 <br />(12) 16d COMMON NAILS <br />(12) 16d COMMON NAILS <br />TRUSS/RAFTER <br />TRUSS/RAFTER <br />NOTE 6 <br />� " x 7 EMBED EPDXY <br />8 0 <br />PAU44 <br />4 " 7 EMBED EPDXY <br />8 0x O <br />HTSM20 <br />12 10dx1 Y2" IN <br />( ) <br />HTWM20 <br />4 x 3" WEDGE BOLT <br />( ) /4 <br />STUD <br />(5) 8d x 1 Y2" IN <br />OR EQUIVALENT IN STUD <br />(5) 8d x 1'/2" IN <br />(12) 16d COMMON NAILS <br />(12) 16d COMMON NAILS <br />ABU66 <br />4 " 0 x 7' EMBED EPDXY <br />� " 0 x 7' EMBED EPDXY <br />8 <br />H2.5T/ <br />TRUSS <br />RT7/ <br />TRUSS <br />(NOTE 6) <br />(12" EMBED AT GARAGE <br />PAU66 <br />(12" EMBED AT GARAGE <br />HA8 <br />(5) 8d x 1 Yz" IN <br />RT7AT <br />(5) 8d x 1'/z" IN <br />DOOR RETURNS) <br />DOOR RETURNS) <br />TOP PLATE <br />(5) 10d x 1'/2" IN <br />TOP PLATE <br />(5) 10d x 1 Y2" IN <br />HU48.. <br />(14) 16d COMMON IN <br />HD48, <br />(14) 16d COMMON IN <br />HUC48, <br />HEADER <br />HD481F, <br />HEADER <br />H8 <br />TRUSS <br />RT8A <br />TRUSS <br />HU28-2, <br />HD28-2, <br />(5) 10d x l Y2" IN <br />(5) 10d x 1'/z" IN <br />HUC28-2 <br />(6) 10d COMMON IN BEAM <br />HD28-21F <br />(6) 10d COMMON IN BEAM <br />TOP PLATE <br />TOP PLATE <br />(16) 10d COMMON TO <br />HU410, <br />(18) 16d COMMON IN <br />HD410, <br />(18) 16d COMMON IN <br />HUC410, <br />HEADER <br />HD4101F, <br />HEADER <br />LGT2 <br />TRUSS/RAFTER <br />'W <br />LUGT2 <br />TRUSS/RAFTER <br />HU210-2, <br />(10) 10d COMMON IN <br />HD210-2, <br />(10) 10d COMMON IN <br />(7) x 2 W' TITEN <br />(5) 0" x 3" WEDGE BOLT <br />HUC210-2 <br />BEAM <br />HD210-21F <br />BEAM <br />SCREWS IN MASONRY <br />(26) 16d SINKER <br />OR EQUIVALENT <br />(28) 16d SINKER IN WALL <br />(22) 16d COMMON IN <br />(22) 16d COMMON IN <br />HUC212-2 <br />HEADER <br />HD212-21F <br />HEADER <br />LGT3 <br />WALL FRAMING <br />LUGT3 <br />FRAMING <br />10 10d COMMON IN BEAM <br />10 10d COMMON IN BEAM <br />(12) SDS '/4" x 2 Yz" <br />(1 <br />(12) WS25 ''/4" x 2 Y2" <br />(4)'/4" x 1 'Y2" SDS SCREW <br />(4) '/4" x 1 %" WS15 SCREWS <br />IN TRUSS <br />IN TRUSS <br />IN TRUSS/RAFTER <br />IN TRUSS/ RAFTER <br />HGA10KT <br />(4)'/4" x 3" SIDS SCREWS <br />HGA10 <br />(4) '/4' x 3" WS3 SCREWS <br />IN TOP PLATE <br />IN TOP PLATE <br />SDWC14500, <br />SDWC15600 <br />NO USP EQUIVALENT <br />(4) SIDS x 1 1/2" SCREWS <br />(4)'W x 1'/2" WS15 SCREWS <br />HGAM10KT <br />IN TRUSS/RAFTER <br />HGAM10KT <br />IN TRUSS/ RAFTER <br />(4)'/4" x 1'/4" WEDGE BOLT <br />(4) W" x 2'/4' TITEN SCREWS <br />IN MASONRY <br />OR EQUIVALENT IN <br />MASONRY <br />NOTES: <br />1. REFER TO FRAMING NOTES THIS SHEET FOR ACRYLIC -TIE INSTALLATION SPECIFICATIONS. <br />2. PRODUCTS SELECTED USING SIMPSON 2019-2020 CATALOG. PRODUCTS MAY BE SUBSTITUTED WITH EQUAL OR BETTER APPROVED ALTERNATES <br />3. REFER TO SIMPSON CATALOG FOR ADDITIONAL INSTALLATION INSTRUCTIONS. <br />4. IF CONNECTOR IS NOT LISTED ABOVE, CONTACT FOR FOR SPECIFIC FASTENING REQUIREMENTS. <br />5. POSITIVE PLACEMENT GUN NAILS, 2'/2" LONG, WITH EQUIVALENT DIAMETER TO COMMON NAILS SPECIFIED ABOVE MAY BE USED FOR <br />ABU POST BASE ANCHORS, CS16. AND MSTA FLAT STRAPS. <br />6. MASONRY APPLICATION REQUIRE EQUIVALENT NUMBER OF TITEN ANCHORS IN LIEU OF 16d NAILS TO HDR CONNECTION. CMU REQUIRES <br />Y,," 0 x 2 %" TITENS ILO 16d. CONCRETE REQUIRES EQUIVALENT NUMBER OF %" 0 x 1 %" TITENS ILO 16d. <br />MASONRY NOTES <br />1. ALL MASONRY UNITS SHALL HAVE fm = 1,500 PSI AND SHALL ERECTED IN RUNNING BOND WITH TYPE M OR S MORTAR OVER FULL <br />BED. <br />2. SHOULD LIMITED AREAS OF STACK BOND MASONRY EXIST, EVERY OTHER COURSE SHALL BE EQUIPPED w/ 9 GAUGE LADDER <br />TYPE HORIZONTAL JOINT REINFORCEMENT <br />3. ALL GROUT TO MIXED PER ASTM C476 STANDARDS AND INSTALLED TO COMPLY WITH FBC R606.3.5. fc = 3,000 PSI. <br />4. VERTICAL WALL REINFORCING TO BE ASTM A615 GRADE 60 REBAR. <br />5. LAPS BETWEEN VERTICAL REINFORCING AND DOWELS TO BE 30". <br />6. VERTICAL REINFORCING TO HAVE 10" STANDARD HOOK INTO BOND BEAM. DOWEL TO HAVE 10" STANDARD HOOK INTO FOOTING <br />7. PRE -CAST MASONRY LINTELS: SEE "TYPICAL PRE -CAST LINTEL OPTIONS" DETAIL ON STRUCTURAL DETAIL SHEET. <br />8. PROVIDE MOISTURE BARRIER FOR ALL UNTREATED LUMBER IN CONTACT WITH MASONRY OR CONCRETE. <br />LEGEND <br />OR <br />LINO <br />FOR <br />EW <br />OSB <br />WSP <br />SYP <br />SPF <br />CONT <br />O.C. <br />LSL <br />LVL <br />PSL <br />SYS 42 <br />2 <br />2 STUDS <br />U) w <br />�o <br />"OR" SHALL MEAN THAT EITHER OPTION PROVIDED IS AN EQUAL <br />ALTERNATIVE FOR THE APPLICATION SHOWN <br />UNLESS NOTED OTHERWISE ON PLAN OR DETAIL <br />ENGINEER OF RECORD <br />EACH WAY <br />ORIENTED STRAND BOARD <br />STRUCTURAL PANEL <br />SOUTHERN YELLOW PINE <br />N <br />Lq <br />PEX <br />0WOOD <br />SPRUCE -PINE -FUR <br />T <br />N <br />CONTINUOUS <br />C <br />N <br />ON CENTER <br />1.55E TIMBERSTRAND LSL ENGINEERED LUMBER, 1 W WIDE, UNO. <br />0')Q <br />(3 %" WIDE LSL BEAMS ARE EQUIVALENT TO 2-PLY 1 W BEAM) <br />2.0E MICROLLAM LVL ENGINEERED LUMBER, 1 3/4" WIDE <br />2.0E PARRALLAM PSL ENGINEERED LUMBER, 3 IV' WIDE, LINO. <br />N <br />PROPERLY RATED OPEN WEB HEADER <br />co <br />J <br />Q <br />INTERIOR ROOF LOAD BEARING WALL, SPECIFICATIONS <br />OUTLINED ON TYPICAL WALL SECTIONS, DETAIL SHEETStd <br />LL. <br />LLJ <br />s <br />INTERIOR BEARING WALL WITH NO UPLIFT. NO UPLIFT ANCHORS REQUIRED. MINIMUM <br />J <br />-0 <br />� <br />BOTTOM PLATE ANCHORAGE IS 1/2" ANCHOR @ 8'-0" O.C. (UNO ON FRAMING PLAN OR <br />tr w design studios <br />SW SPECIFICATIONS) <br />z <br />0 <br />STRUCTURAL WOOD BEAM <br />co <br />Y <br />U <br />9000 REGENCY SQUARE BLVD. <br />a)STUD <br />COLUMN KEYNOTE <br />Q <br />SUITE 100, JACKSONVILLE, FL 32211 <br />NUMBER OF SDWC15600 CONNECTING TOP PLATE TO STUDS. <br />O <br />O <br />NUMBER OF STUDS BELOW BEAM/GIRDER TRUSS. STUDS O <br />TO MATCH WALL FRAMING SIZE AND GRADE, UNO. <br />LL1 <br />ADDITIONAL CLARITY FOR THE LOCATION OF THE STUD COLUMN ~ to <br />2 ANCHOR U ► RR N <br />ll��BOTTOM OF STUD COLUMN CONNECTION � <br />1ST LEVEL STUD COLUMN: HOLDDOWN REQUIRED AT BASE OF COLUMN e • \ , <br />saa4. <br />2ND LEVEL STUD COLUMN: STRAPPING REQUIRED FROM 2ND LEVEL J\„ <br />COLUMN TO 1ST LEVEL STUDS/HEADER/BEAM. 00 � �� a <br />OF <br />"ANCHOR" REQUIRES BOTTOM PLATE ANCHOR WITHIN 3" OF STUD COLUMN W <br />NUMBER OF SDWC15450 CONNECTING STUDS TO BOTTOM PLATE <br />HEADER STRAPPING KEYNOTE <br />NUMBER OF STRAPS CONNECTING HEADER TO JACK STUD U) <br />} N <br />1 MSTA24 TYPE OF STRAP CONNECTING HEADER TO JACK STUD U <br />T <br />DTT2Z KING/JACK GROUP BOTTOM CONNECTION Z W <br />1ST LEVEL STUD GROUP: HOLDDOWN REQUIRED AT BASE OF STUD GROUP Ur <br />2ND LEVEL STUD COLUMN: STRAPPING REQUIRED FROM 2ND LEVEL STUD W <br />GROUP TO 1ST LEVEL STUDS/HEADER/BEAM. 1� <br />This item has been electronically <br />NUMBER OF HOLDDOWNS/STRAPS AT BASE OF KING/JACK GROUP 0 signed and sealed by Justin M Lanier, <br />PE on the date and/or time stamp <br />NON -BEARING HEADER FRAMING KEYNOTE � shown using a digital signature. <br />Printed copies of this document are <br />NO HDR - # NUMBER OF KING STUDS EACH SIDE OF OPENING not considered signed and sealed <br />IT >1111111110 <br />and the signature must be verified <br />HEADER MAY BE FRAMED AS NON BEARING HEADER DUE TO LIGHTLY ti by a 3rd Party Certificate Authority <br />on any electronic copy <br />LOADED CONDITIONS ABOVE O QU) <br />#2 SYP HEADER FRAMING KEYNOTE Z W fe W <br />(2) 2x10 - 1 / 2 NUMBER OF KING STUDS EACH SIDE OF OPENING W Q W 00/ <br />-0 <br />NUMBER OF JACK STUDS EACH SIDE OF OPENING z MMJ Z W <br />DEPTH OF LOAD -BEARING #2 SYP HEADER O <br />NUMBER OF PLIES IN HEADER m U) <br />ENGINEERED LUMBER HEADER FRAMING KEYNOTE W Q <br />NUMBER OF KING STUDS EACH SIDE OF OPENING W a <br />Z <br />O <br />> <br />NUMBER OF JACK STUDS EACH SIDE OF OPENING <br />Z <br />Q <br />Q <br />HEADER MATERIAL (LSL, LVL, PSL, OR SYS42) <br />W <br />W <br />W <br />DEPTH OF LOAD -BEARING EWP HEADER <br />Q <br />Q <br />NUMBER OF PLIES IN HEADER (1 %" WIDE UNO) <br />0 <br />LLj LU <br />HEADER FRAMING <br />_1 <br />X <br />W <br />T- <br />1. <br />ALL HEADER JACK AND KING STU DS SHALL BE FASTENED TO EACH OTHER WITH (2) ROWS 10d @ 8" O.C. <br />Z <br />STAGGERED. <br />Z <br />2. <br />NON BEARING HEADERS: DUE TO LIGHTLY LOADED CONDITIONS, 49" OR LESS CLEAR -OPENINGS IN AN <br />I-_ <br />Q <br />EXTERIOR WALL DO NOT REQUIRE LOAD BEARING HEADER, SEE PLAN. <br />Q <br />0 <br />3. <br />FASTEN ALL MULTI -PLY HEADERS TOGETHER WITH (2) ROWS 10d @ 8" O.C., STAGGERED ALONG EACH EDGE. <br />0� <br />LLI <br />4. <br />FASTEN ALL HEADERS TO KING STUDS WITH (3)8d TOE NAILS <br />0 <br />5. <br />IF HEADER NOT SPECIFIED, CONTACT ENGINEER OF RECORD. <br />a <br />Z <br />6. <br />UNO ON PLAN, MIN (1) SDWC15600 TOP PLT TO KING STUD AND (1) SDWC15450 KING STUD TO BOTTOM PLATE <br />0-1 <br />11 <br />CONNECTION REQUIRED EACH SIDE OF OPENING (NO CONNECTION REQUIRED FOR OPENINGS AT FIRST <br />0 <br />U <br />d <br />FLOOR HEADER WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE. <br />W <br />7. <br />TOP PLATE TO HEADER CONNECTION PER ONE OF THE FOLLOWING (NO CONNECTION REQUIRED FOR <br />Q <br />W <br />OPENINGS 39" OR LESS, OR AT FIRST FLOOR HEADERS WHEN A 2ND LEVEL FLOOR SYSTEM IS ABOVE: <br />Abbott Park <br />• SDWC15600 @ MAX 32" O.C. AS SHOWN, "ALTERNATE SECTION (HEADERS),ST-5 <br />0 <br />Q <br />U <br />• SPH w/ (12) 10d x 1- 1/2" @ 16" O.C. OR <br />• DSP w/ (14) 10d x 1- Y2" @ 16" O.C. OR <br />W <br />LOT 033-02 <br />C <br />• FASTEN TRUSS DIRECTLY TO HEADER w/ MTS OR HTS w/ (14) 10d x 1 '/2' (OR EQUAL APPROVED BY EOR). <br />Q <br />W <br />8. CRIPPLE BLOCKS BELOW LOAD -BEARING HEADERS MAY BE FRAMED AT 24" O.C. <br />- <br />U <br />Q <br />z <br />z <br />0 <br />FRAMING NOTES <br />0 <br />PROJECT NO <br />LLJ <br />1. <br />SIMPSON ACRYLIC -TIE ADHESIVE OR EQUAL SHALL BE USED IN ALL DRILLED AND EPDXIED ANCHOR APPLICATIONS. <br />2021.011 O79 <br />Q <br />ANCHOR BOLT, THREADED ROD, OR DOWELED REINFORCING STEEL MAY BE EMBEDDED TO THE SPECIFIED DEPTH, IN <br />0 <br />LL <br />A HOLE AS SPECIFIED BY MANF (TYPICALLY 1/16" TO 1/8" GREATER THAN SPECIFIED ANCHOR DIAMETER). <br />Z <br />O <br />ADHESIVE/EPDXY MUST FILL THE HOLE IN THE CONCRETE AND WOOD BOTTOM PLATE. MANUFACTURER'S <br />= <br />DRAWN <br />JAR <br />SPECIFICATIONS MUST BE FOLLOWED FOR PROPER INSTALLATION. <br />U <br />O <br />2. <br />ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR DRY USE ONLY, UNO. ALL WATERPROOFING AND FIRE SAFETY <br />�W <br />CHKD <br />Ln <br />SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHER. <br />MJP <br />U) <br />3. <br />ALL METAL CONNECTORS SPECIFIED ON PLAN ARE IN ADDITION TO FRAMING FASTENER REQUIREMENTS LISTED IN <br />W <br />W <br />TABLE 2304.10.1 <br />0- <br />J <br />4. <br />BEAMS IDENTIFIED BY NUMBER ON PLAN ARE TO BE PROVIDED BY TRUSS MANUFACTURER OR LUMBER SUPPLIER. <br />5. <br />FASTEN ALL MULTI -PLY STUD COLUMNS AND CORNERS TOGETHER WITH (2) ROWS 10d @ 8" O.C. STAGGERED. <br />X <br />U <br />UPPER LEVEL MULTI -PLY STUD GROUPS BELOW ALL GIRDER LOCATIONS TO BE CONTINUOUS THROUGH FLOOR <br />Q <br />������������� <br />U) <br />SYSTEM TO FOUNDATION. (NOT REQUIRED BELOW HEADER JACK/KING STUD GROUPS) <br />6. <br />FASTEN ALL STUDS TO BOTTOM AND TOP PLATES WITH (4)8d TOE NAILS OR (2)16d COMMON END NAILS.•'' <br />m <br />G•E N ' .'4 �'� <br />S� •.• �� <br />z <br />7. <br />FASTEN ALL TRUSSES AND RAFTERS TO TOP PLATES WITH (3)8d TOE NAILS. <br />.•'�,\ <br />8. <br />ALL MULTI -PLY TRUSS GIRDERS AND BEAMS TO HAVE SOLID STUD GROUP BELOW MATCHING GIRDER OR BEAM <br />0 <br />N 0 85166 <br />Q <br />THICKNESS AND MATCHING WALL STUD SPECIFICATIONS AS NOTED ON STRUCTURAL PLAN, UNO. <br />W <br />* •• <br />9. <br />EXTERIOR WALL DESIGN ASSUMES CONTINUOUSLY SHEATHED WITH OSB OR PLYWOOD <br />z <br />'• DocuSigned by: <br />W O :•• XT +-DAQF F435..•• 411 <br />Q <br />0 09-16-2021Cn <br />p <br />I= w <br />U REVISIONS: <br />U- <br />No. Descriptionnnnnnnn T Date <br />w <br />U) J <br />Q <br />0 --- _ W <br />0 O <br />0 z <br />z <br />2 <br />U <br />w <br />F_ <br />x ST=1 <br />w <br />W <br />CMUIMETAL CONNECTOR ENGINEERING <br />