My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8414 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8414 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:54:24 PM
Creation date
2/27/2025 1:21:49 PM
Metadata
Fields
Template:
Building Plans
Street #
8414
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
3234
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Docus,gn Enveiope ID. 59E322ED-B805-4C40-9CBE-66588D6B89B9 <br />TRUSS TO TOP PLATE, MOISTURE BARRIER—� <br />UNO: BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT NON -PT LUMBER BY OTHERS <br />W/ H8 OR H10 <br />• TRUSS LENGTH </ 10 FT VERT. REINFORCING TO <br />W/ H2.5T OR RT7AT OR HAVE 10" STANDARD <br />SDWC15600 HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32'. O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />�P►�9CI���'��i <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 k " IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />(1) COURSE CMU BOND <br />BEAM W/ #5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x_ NO. SPF OR BETTER @ MAX 16" O.C. <br />BOTTOM PLT ANCHOR <br />'/i' THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />Y2" WEDGE BOLT W/ MIN 4Y2' EMBED W/ <br />WASHER @ MAX 48" O.C. <br />r <br />BOTTOM PLATE ANCHOR NOTES <br />• EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />-INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />8" PARTIALLY GROUTED <br />- EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />[L <br />_j - PROVIDE DOWELS TO MATCH <br />o I ( VERTICAL WALL <br />Z REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />d da MASONRY) <br />� I d <br />Q � <br />\ <br />\ a \%\/// /% <br />\//\///\ <br />�\ <br />\\\\\\\\\\\\\\\\\\\\\ <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />ROOF-1 <br />COW <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />3/4" BETWEEN TOP OF WOOD PANEL <br />AND CENTER OF FASTENERS. <br />MIN 1%2" EXPOSURE 1 PLYWOOD RIM @ RAISED <br />HEEL TRUSSES INSTALLED WITH LONG <br />DIMENSION PERPENDICULAR TO TRUSS END <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 Y2" <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />FOR MISLOCATIO <br />FASTEN 2x6 NO. 2 <br />TO TRUSS W/ MIN <br />FOR MISLOCATIO' <br />INSTALL NEW MAE <br />STRAP TO INSIDE <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />2 <br />(1) #4 OR #5 BAR AT CORNERS <br />WITH MIN. 25" LAP <br />#5 CONT. <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />GENERAL NOTES APPLICABLE TO ALL: <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />U <br />0 <br />N <br />0 <br />N <br />POURED CELL w #5 BAR CONT <br />FROM BEAM TO FOOTING <br />STEP DOWN TIE -BEAM <br />DIST. FROM DOORJAMB <br />MIN. SCREW <br />DIST. FROM DOORJAMB <br />MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH <br />/ WINDOW TO BLOCK <br />LENGTH <br />94" OR 1%4" <br />PER MANUF. <br />3" <br />5" <br />11/2 <br />3 %4' <br />3 7/16 <br />5„ <br />111116 <br />3 3/4' <br />3 3/ "' <br />6„ <br />2 /4, <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWS%" DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS 3/6' DIA. @ 24" O.C. STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1x_ PER MANUFACTURER'S DETAILS <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />o <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED W) <br />1x_ PT NAILER <br />BUILT UP 2x_ATTACHED TO MASONRY, (1) PLY <br />1 x_ OR �6 OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DOORMINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />U <br />O <br />O <br />N <br />L3 <br />O <br />C <br />APEX <br />U <br />Q) <br />O <br />M <br />� <br />CL7 <br />L2 <br />R3 <br />r <br />N <br />co <br />S <br />>}SS <br />J <br />U_ <br />W <br />tds <br />J <br />true design studios <br />a) <br />z <br />O <br />U <br />U <br />Q <br />9000 REGENCY SQUARE BLVD. <br />SUITE 100, JACKSONVILLE, FL 32211 <br />a) <br />o <br />O <br />0 <br />LU <br />H <br />UsIH019ON" <br />0 <br />J <br />m <br />W <br />Q. <br />Q 4- <br />U) <br />U <br />Z <br />W <br />(D <br />W <br />This item has been electronically <br />0 signed and sealed by Justin M Lanier, <br />O PE on the date and/or time stamp <br />O shown using a digital signature. <br />Printed copies of this document are <br />not considered signed and sealed <br />nd the signature must be verified <br />by a 3rd Party Certificate Authority <br />0 <n any electronic copy UI _ <br />Z j <br />U w N <br />W 0. <br />—� z w <br />LLJ O c) <br />m <br />w <br />W QW <br />Z <br />z > Q Q <br />m w <br />Q J w W <br />0 w w <br />� <br />O <br />x <br />X <br />� <br />ILL <br />LL <br />z <br />� <br />O <br />z <br />F_ <br />O <br />Q <br />0 <br />Of <br />W <br />a <br />z <br />O <br />0- <br />U <br />LL <br />Q <br />� <br />W <br />Abbott Park <br />J <br />Q <br />O <br />U <br />J <br />W <br />LOT 035-02 <br />U) <br />0 <br />Q <br />W <br />U <br />Q <br />z_ <br />z <br />} <br />(D <br />CD <br />O <br />PROJECT NO <br />U) <br />LLI <br />0 <br />1 <br />O <br />2021.011081 <br />W <br />DRAWN: <br />KAS <br />O <br />U <br />WCHKD: <br />o <br />L0 <br />x <br />MJP <br />� <br />W <br />W <br />� <br />U <br />Q`0"1111 <br /># 11111i <br />LqN�� 40'.. <br />cA <br />} <br />SG(iN <br />, • • \�E N S ' .'9 •� <br />' �• F <br />Z_ <br />W <br />No 85166 <br />z <br />.. * ; DocuSigned by: '• �' � <br />Q <br />OL* <br />- <br />i <br />C <br />''I <br />O••• AGGf-435 - <br />Al � <br />U) <br />• .•�� <br />F0 RC? <br />ss,O <br />z <br />N Ai <br />Q <br />O <br />09-17-2021 <br />0 <br />W <br />U <br />REVISIONS: <br />W <br />J <br />Q <br />U <br />co <br />I— <br />O <br />z <br />= O <br />U � <br />W <br />X <br />W ST=5 <br />n <br />CMUIMETAL CONNECTOR ENGINEERING <br />LL <br />Q <br />U) <br />} <br />0 <br />O <br />J <br />O <br />z <br />
The URL can be used to link to this page
Your browser does not support the video tag.