VENTED SOFFIT <br />46 SQ. FT. <br />ATTIC VENTILATION CALCULATIONS - A <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SO. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of o <br />ventilation f vented <br />IN. of <br />of <br />vented <br />ventilation to <br />be provided <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />(See Elev) <br />required soffit <br />ventilation <br />soffit <br />y upper <br />Ventilation <br />Ventilation <br />needed <br />required <br />needed <br />ventilators <br />Main <br />29.00000 <br />1.000000 <br />Floor <br />2373 <br />2278 <br />325 <br />1139 <br />81 <br />570 <br />0 <br />573.0 <br />435.0 <br />138.0 <br />(Zone 1) <br />"NOTE" <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 5th ED. RESIDENTIAL. <br />VENTED SOFFIT LEGEND <br />IF SOFFIT IS LABELED AS "NON -VENTING" FIRE PROTECTION WILL BE INSTALLED <br />AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL. IF <br />LABELED AS "VENTED", NO FIRE PROTECTION WILL BE REQUIRED. <br />• : �•• <br />VENTED SOFFIT <br />VENTED SOFFIT <br />67 SQ. FT. <br />• . . . .. . .. u7 <br />c6 :: I <br />: ....... RIDGE <br />41 <br />i <br />04 <br />if) <br />ZONE-1 '::::::::::....:::::::::::.::::::::::::::...... <br />ATTIC SPACE <br />2373 SQ. FT. 4'-0'ROOFVENT <br />• e :12 SLOPE 14'-0' RIDGE VENT <br />W <br />a- <br />O <br />...................... <br />•• •' VENTED SOFFIT <br />:.::::::::: 8 SQ. FT. <br />��' <br />5:12 SLOPE <br />j•�.: <br />.... ..... ............: ' :::. ..... <br />.. .. 414 <br />.. <br />:.• ..• <br />..• ..• <br />VENTED SOFFIT <br />58 SQ. FT. <br />w <br />a <br />O <br />... <br />VENTED SOFFIT <br />10 SQ. FT. <br />VENTED SOFFIT <br />19 SQ. FT. <br />ROOF PLAN <br />SCALE: %4'=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portend cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by save or comics vents. <br />"CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA UNIT <br />• SOFFIT VENTS - 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SO. IN. OF NET FREE AREA/ FT. <br />" (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of alloon Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />Formula: (Sq. Ft SoRit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft of Deck -Air Needed) <br />• O'HAGIN (file Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT <br />"Formula: (Sq. Ft soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed <br />0 <br />zo <br />— o <br />Z �oVia <br />Z <br />Q <br />J <br />r2 <br />Z <br />0 <br />W <br />(Diflo <br />w <br />o <br />U — <br />0 LLI <br />c <br />�- <br />fLh <br />M <br />v I <br />O <br />m <br />U <br />LU <br />M <br />m M <br />00N <br />_ <br />U N <br />tLL00 <br />c <br />c o <br />Q rn <br />r° CL o <br />Lo n 'v <br />0)Q o <br />A' <br />B <br />D. <br />N C B D C <br />` .f <br />Ryi+� A n <br />e <br />N 5 +< — <br />At <br />- •(per '1 r'\'� <br />W d <br />lu W <br />,7 o�, <br />�. r 1 <br />O� <br />LL <br />cP <br />II "? N• "•• <br />°' <br />�`• <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />i <br />O <br />Z NO <br />0 0) N <br />r>-r M O <br />in <br />tj fC In <br />a <br />Mr <br />Q U ll 1 <br />a .-. <br />QV CL'-4 <br />00 <br />z <br />.� <br />z § <br />Z M <br />J � <br />W <br />J <br />�Z <br />wa <br />za <br />f f- <br />ej <br />Z�v <br />Zz <br />�W <br />8® <br />d' <br />z <br />Zo <br />rU <br />f Z <br />Z <br />M <br />o <br />`) <br />_ <br />LL <br />Lu <br />Lu <br />iU-Oo <br />o <br />O� <br />O <br />11 <br />r14 <br />8 J <br />Z <br />Q <br />A <br />Q <br />Z <br />z <br />Nrou <br />s <br />LU <br />Ln <br />rl <br />111 <br />LLJ <br />U R Z <br />M <br />Q <br />Z <br />Z <br />m <br />,-1 <br />Z <br />Z <br />o <br />^ <br />g <br />L <br />z <br />LU <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION NO. 10 <br />SHEET NO. <br />5.0 <br />