Laserfiche WebLink
FF <br />s <br />March 20, 2018 <br />Re: Wood Construction Connector Compliance for 2015 International Codes & 2017 Florida Codes <br />To Whom It May Concern: <br />Section 2303;5 of the 2015 International Building Code (IBC) and 2017 Florida Building Code (FBC) specifies that <br />joist hangers shall be tested per ASTM D7147 Testing and Establishing Loads of Joist Hangers. Previous versions of <br />the IBC and FBC required testing to comply with ASTM D1761 Test Method for Mechanical Fasteners in Wool. Both <br />methods determine a connector's allowable load as the lowest of the following: <br />1. Lowest ultimate of three tests (or average of 6) with a safety factor of 3 <br />2. Average load at 118-inch deflection <br />3. Calculations per American Wood Council National Design Specification for Wood Construction (NDS) <br />The primary changes in ASTM D7147 are requirements to measure properties of the tested materials, such as steel <br />strength, fastener strength, and wood specific gravity The tested ultimate loads must be adjusted when tested <br />material properties exceed the specified properties. <br />ICC Evaluation Services (ICC-ES) revised AC13 Acceptance Criteria for Joist Hangers and Similar Devices in <br />October 2016 to incorporate a methodology to evaluate products to the 2015 I -Codes. Simpson Strong -Tie is working <br />on re-evaluating wood construction connector loads to the new standard to update our product evaluation reports to <br />the 2015 I -Codes. As soon as the updated evaluation reports are completed, we will apply for Florida Product <br />Approvals. <br />However, reevaluating a large number of products will take time. While manufacturers work with product certification <br />agencies to update their wood connector evaluation reports, we recommend that building departments under the <br />2015 I -Codes and 2017 Florida Codes continue to accept code reports showing compliance to the 2012 and 2014 <br />editions, respectively, until July 2018. <br />The information in this letter is valid until 6/30/2018 Men d will be re-evaluated by Simpson Strong -Tie. Please visit <br />www.stronotie,com for additional pertinent information. If you have questions or need further assistance regarding <br />this matter, please contact the Simpson Strong -Tie Engineering Department at 800.999.5099. <br />Sincerely, <br />SIMPSON STRONG -TIE COMPANY INC. <br />Keith Cullum, P.E„ LEED AP dwlBDW <br />Engineer, Southeast U.S. Branch <br />Page 1 of 1 <br />Simpson Strong -Tie Company Inc. 2221 Country Lane McKinney, TX 75059 Phone: 972.542.0326 Fez 972.542.4139 stronatie.com <br />to � <br />-0O U <br />N 2 _0 <br />N Q Q ^O <br />I..L <br />� N <br />CU cu <br />O O O 'O 0 <br />= 0 <br />= O L,L <br />CIO O 4_ CU <br />C O Q <br />V) Q L Q L <br />� 0 'C^ Q <br />.� V) Q <br />o <br />� <br />U <br />O <br />O <br />L� <br />Q <br />U <br />O <br />L <br />V, <br />m <br />L� <br />UcJ <br />G <br />a � <br />z J <br />z <br />J <br />d <br />SHEET NO. <br />PA 1.0 <br />5 pe <br />firr .. � ,.. x Y <br />� : . e � .� G 6 <br />°i� k : � �� xu 5... 9.�r;-,A�`,dy <br />. ai <br />� <br />� ;si: m , ♦ A . <br />p $'vF �� �,.. <br />4 <br />A3 <br />FL17244.1 <br />ESR-3455 <br />A23 <br />FL10446.2 <br />ESR-2806 <br />HD210-2 <br />FL17232.3 <br />ESR-3445 <br />HU210-2 <br />FL10856.4 <br />ESR-2549 <br />HD212.2 <br />FL17232.3 <br />ESR-3445 <br />HU212-2 <br />FL10858.4 <br />ESR-2549 <br />HD216 <br />FL17232.3 <br />ESR-3445 <br />HU216 <br />FL10858.5 <br />ESR-2549 <br />HD2t&3 <br />FL17232.3 <br />ESR-3445 <br />HU216.3 <br />FL10856.1 <br />ESR-2549 <br />HD28 <br />FL17232.2 <br />ESR-3445 <br />HU28 <br />FL10658.3 <br />ESR-2549 <br />HD26-2 <br />FL17232.3 <br />ESR-3445 <br />HU28-2 <br />FL10858.4 <br />ESR-2549 <br />HD410 <br />FL17232.4 <br />ESR-3445 <br />HU410 <br />FL10856.9 <br />ESR-2549 <br />HD412 <br />FL17232.4 <br />ESR-3445 <br />HU412 <br />FL10656.9 <br />ESR•2549 <br />HD810 <br />FL17232.4 <br />ESR-3445 <br />HU610 <br />FL10858.10 <br />ESR-2549 <br />HD0410 <br />FL17241.7 <br />ESR-3444 <br />HUC0410 <br />FL11468.11 <br />SIM200804 <br />HGA10 <br />FL17699,1 <br />Evaluation Report <br />HGA10KT <br />FL11470.4 <br />SIM200803 <br />HGAM10 <br />FL17699.1 <br />Evaluation Report <br />HGAM10KT <br />FL11470.4 <br />SIM200803 <br />HHCP2 <br />FL17236.7 <br />ESR-3448 <br />HCP2 <br />FL10447.2 <br />ESR-2551 <br />HTA16 <br />FL17680.4 <br />Evaluation Report <br />HETA16 <br />FL11473.5 <br />SIM200802 <br />HTA20-18 <br />FL17680.4 <br />Evaluation Report <br />HETA20 <br />FL11473.5 <br />SIM200802 <br />HTT16 <br />FL17324.2 <br />Evaluation Repoli <br />HTT16 <br />FL11498.1 <br />ES-0130 <br />HTT45 <br />FL17324.2 <br />Evaluation Report <br />HTT22 <br />FL11496.1 <br />ES-0130 <br />HTW18 <br />FL17244.8 <br />ESR-3455 <br />HTS16 <br />FL10456.22 <br />ESR-2813 <br />HTW20 <br />FL17244.8 <br />ESR-3455 <br />HTS20 <br />FL10456.23 <br />ESR-2813 <br />HTW24 <br />FL17244.8 <br />ESR-3455 <br />HTS24 <br />FL10456.24 <br />ESR-2613 <br />HTW30 <br />FL17244.8 <br />ESR-3455 <br />HTS30 <br />FL10456.26 <br />ESR-2613 <br />HTWM18 <br />FL6223.2 <br />Evaluation Report <br />HTSM16 <br />FL11473.11 <br />SIM200802 <br />HTWM20 <br />FL6223.2 <br />Evaluation Report <br />HTSM20 <br />FL11473.11 <br />SIM200802 <br />HUGT2 <br />FL8223.3 <br />Evaluation Report <br />HGT2 <br />FL10458.18 <br />ESR-2613 <br />HUGT3 <br />FL8223.3 <br />Evaluation Report <br />HGT3 <br />FL10458.19 <br />ESR-2813 <br />HUS210-2 <br />FL17232.6 <br />ESR-3445 <br />HUS210-2 <br />FL10856-R4 <br />ESR-2549 <br />HUS212-2 <br />FL17232.6 <br />ESR-3445 <br />HUS212-2 <br />FL10658.11 <br />ESR-2549 <br />HUS28 <br />FL17232.6 <br />ESR-3445 <br />HUS26 <br />FL10856.11 <br />ESR-2549 <br />HUS28 <br />FL17232.6 <br />ESR-3445 <br />HUS28 <br />FL10856.11 <br />ESR-2549 <br />HUS28-2 <br />FL17232,6 <br />ESR-3445 <br />HUS28-2 <br />FL10856.11 <br />ESR-2549 <br />JL24 <br />FL17232.7 <br />ESR-3445 <br />LU24 <br />FL10655.103 <br />ESR-2549 <br />JL26 <br />FL17232.7 <br />ESR-3445 <br />LU26 <br />FL10855.104 <br />ESR-2549 <br />JUS210-2 <br />FL17232.11 <br />ESR-3445 <br />LUS210-2 <br />FL10855.107 <br />ESR-2549 <br />JUS24 <br />FLt7232.10 <br />ESR-3445 <br />LUS24 <br />FL10655.109 <br />ESR-2549 <br />JUS28 <br />FL17232.11 <br />ESR-3445 <br />LUS26 <br />FL10855.111 <br />ESR-2549 <br />JUS28-2 <br />FL17232.11 <br />ESR-3445 <br />LUS26-2 <br />FL10655.112 <br />ESR-2549 <br />JUS28 <br />FL17232.11 <br />ESR-3445 <br />LUS28 <br />FL10655.113 <br />ESR-2549 <br />JUS46 <br />FL17232.11 <br />ESR-3445 <br />LUS48 <br />FL10655.118 <br />ESR-2549 <br />KLEG3 <br />FL17241.15 <br />ESR-3444 <br />LEGS <br />FL10667.71 <br />ESR-2815 <br />KST260 <br />FL17244.15 <br />ESR-3455 <br />MST80 <br />FL10852.7 <br />ESR-2105 <br />LSTA 12 <br />FL17244.18 <br />ESR-3455 <br />LSTA12 <br />FL10652.4 <br />ESR-2105 <br />LSTA15 <br />FL17244.18 <br />ESR-3455 <br />LSTA15 <br />FL10852.4 <br />ESR-2105 <br />LSTA18 <br />FL17244.18 <br />ESR-3455 <br />LSTA18 <br />FL10852.4 <br />ESR-2105 <br />LSTA24 <br />FL17244.18 <br />ESR-3455 <br />LSTA24 <br />FL10852.4 <br />ESR-2105 <br />LSTA30 <br />FL17244.18 <br />ESR-3455 <br />LSTA30 <br />FL10852.4 <br />ESR-2105 <br />LSTA38 <br />FL17244.18 <br />ESR-3455 <br />LSTA36 <br />FL10852.5 <br />ESR-2105 <br />LTS19 <br />FL17219.2 <br />ER-0200 <br />LTT19 <br />FL11498.3 <br />ER-130 <br />LTS20B <br />FL17219.2 <br />ER-0200 <br />LTT20B <br />FL11496.3 <br />ER-130 <br />LTTI31 <br />FL17219.2 <br />ER-0200 <br />LTTI31 <br />FL11498.3 <br />ER-130 <br />LTW12 <br />FL17244.8 <br />ESR-3455 <br />LTS12 <br />FL10456.29 <br />ESR-2813 <br />LUGT2 <br />FL17240.2 <br />ESR-3447 <br />LGT2 <br />FL11470.7 <br />SIM200803 <br />MP3 <br />FL17244.22 <br />ESR-3455 <br />LS30 <br />FL10448.15 <br />ESR-2608 <br />MP34 <br />FL17244.23 <br />ESR-3455 <br />A34 <br />FL10446.3 <br />ESR-2608 <br />MP4F <br />FL17244.24 <br />ESR-3455 <br />LTP4 <br />FL10448.19 <br />ESR-2806 <br />MP5 <br />FL17244.22 <br />ESR-3455 <br />LS50 <br />FL10448.18 <br />ESR-2608 <br />MPH3518 <br />FL17240.3 <br />ESR-3447 <br />WMI416 <br />FL10887.86 <br />ESR-2615 <br />MSTA12 <br />FL17244.18 <br />ESR-3455 <br />MSTA12 <br />FL10852.8 <br />ESR-2105 <br />MSTA15 <br />FL17244.16 <br />ESR-3455 <br />MSTA15 <br />FL10852.8 <br />ESR-2105 <br />MSTA18 <br />FL17244.16 <br />ESR-3455 <br />MSTA18 <br />FL10852.9 <br />ESR-2105 <br />MSTA24 <br />FL17244.18 <br />ESR-3455 <br />MSTA24 <br />FL10852.9 <br />ESR-2105 <br />MSTA36 <br />FL17244.16 <br />ESR-3455 <br />MSTA36 <br />FL10652.9 <br />ESR-2105 <br />MSTC40 <br />FL17244.26 <br />ESR-3455 <br />MSTC40 <br />FL10652.11 <br />ESR-2105 <br />MSTC52 <br />FL17244.26 <br />ESR-3455 <br />MSTC52 <br />FL10852.11 <br />ESR-2105 <br />MTW12 <br />FL17244.8 <br />ESR-3455 <br />MTS12 <br />FL10458.33 <br />ESR-2813 <br />MTW18 <br />FL17244.8 <br />ESR-3455 <br />MTS18 <br />FL10458.34 <br />ESR-2813 <br />MTW18 <br />FL17244.8 <br />ESR-3455 <br />MTS18 <br />FL10458.35 <br />ESR-2613 <br />MTW20 <br />FL17244.8 <br />ESR-3455 <br />MTS20 <br />FL10458.38 <br />ESR-2813 <br />MUGT15 <br />FL17240.5 <br />ESR-3447 <br />MGT <br />FL11470.9 <br />SIM200803 <br />NFM35X12 <br />FL578.2 <br />Evacuation Report <br />MBHA3.58/11.25 <br />FL13804.8 <br />ESR-281 <br />PRODUCT APPROVAL SPECIFICATION SHEET (2018) March 28, 2018 <br />As required by Florida Statute 553.842 and Florida Administrative Code 98-72, please provide the information and approval numbers on the building components listed below if they will be utilized on the <br />construction project for which you are applying for a building permit. We recommend you contact your local product supplier should you not know the product approval number for any of the applicable listed <br />products. <br />Category/Subcategory <br />Manufacturer <br />Product Description <br />Approval Number(s) <br />Test Pressures <br />1. EXTERIOR DOORS <br />A. SWINGING <br />ThermaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL20481.1 <br />+67.0/-67.0 psf <br />ThermaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL20461.6 <br />+67.0/-87.0 psf <br />ThermaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL20461.9 <br />+67.0/-67.0 psf <br />ThermaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL20461.14 <br />+67.0/-67.0 psf <br />ThermaTru <br />Classic -Craft and Benchmark <br />FL15225.1 <br />+87.0/-87.0 psf <br />ThermaTru <br />Smooth -Star and Benchmark <br />FL15225.5 <br />+87.0/-67.0 psf <br />ThermaTru <br />FiberClassic, Smoofhstar, ClassicCraft, Rustic <br />FL7640.1 <br />+87.0/-67.0 psf <br />B. SLIDING <br />MI Windows and Doors <br />Series 420 <br />FL15332.1 - FL15332.5 <br />+40.0/-40.0 psf <br />PGT <br />Series 5570 <br />FL251.10 <br />C. SECTIONAL <br />Clopay Building Products <br />Residential WindCode Doors W5 (8X7) <br />FL15279.37 <br />+30.0/-32.0 psf <br />Clopay Building Products <br />Residential Vt4ntlCode Doors W5 (16X7) <br />FL15279:53 <br />+30.0/-30.0 psf <br />Clopay Building Products <br />Residential VWndCode Doors VvB (SX7) <br />FL15279.65 <br />+38.0l-42.0 psf <br />Clopay Building Products <br />Residential W�ndCode Doors W6 (16X7) <br />FL15279.102 <br />+37.0/-41.0 psf <br />D. METAL LOUVERED DRS <br />Curries Division of AADG, Inc <br />607,707,727,747,and 647 Single &Pairs of Doors <br />FLt 1537.1 <br />N/A (see inst sht) <br />2. WINDOWS <br />A. SINGLE HUNG <br />MI Windows and Doors <br />Series 185 <br />FL17499.2 <br />+50.0/-55.0 psf <br />PGT <br />Series 5500 <br />FL239.7 <br />B. HORIZONTAL SLIDER <br />MI Windows and Doors <br />Series 188 <br />FL15351.1 <br />+40.0/-50.0 psf <br />C. FIXED <br />MI Windows and Doors <br />Series 185 <br />FL15349.1 <br />+40.0/-40.0 psf <br />PGT <br />Series 5520 <br />FL243.9 <br />D. MULLION <br />MI Windows and Doors <br />Series 5764 <br />FL15353.2 <br />N/A <br />PGT <br />Series 5500 <br />FL261.1 <br />N/A <br />E. OTHER <br />3. PANEL WALL <br />A. SIDING <br />James Hardie Building Prod. <br />Cemplank Lap Siding and HardiePlank lap Siding <br />FL13192.1 - FL13192.2 <br />N/A <br />B. SOFFITS <br />Alside <br />Solid and Vented Soffit <br />FL15272.1 • FL152722 <br />+70.0/-70.0 psf <br />C. OTHER <br />4. ROOFING PRODUCTS <br />A. ASPHALT SHINGLES <br />GAF <br />3 Tab, Dimensional <br />FL10124.1 <br />N/A <br />B. UNDERLAYMENTS <br />Tamko <br />151b Felt Underlayment <br />FL12328.6 <br />N/A <br />G. ROOFING FASTENERS <br />NOT USED <br />D. ROOF VENTILATORS <br />Thompson Arch Metal Comp. <br />Off Ridge Vents <br />FL16918.1 - FL16918.4 <br />N/A <br />Florida Metal Products, Inc <br />Vent RV10 <br />FL21580.3 <br />N/A <br />Lomanco, Inc <br />DA-4 Exahust Vent <br />FL17202.1 <br />N/A <br />E. ROOFING TILES <br />Boral Tile <br />Villa 900 <br />FL7849.27 - FL7849.28 <br />N/A <br />Sorel Tile <br />Saxony 900 <br />FL7849.16 • FL7649.20 <br />N/A <br />F. METAL ROOF <br />Gulf Coast Supply &Manufacturing, LLC <br />0.032" Aluminum Gulftok 16" wide roof panel <br />FL11651.2 R3 <br />N/A <br />5. SHUTTERS <br />A. STORM PANELS <br />Global Protection Products <br />Galvanized Steel Storm Panels <br />FL15078.1 - FL15076.2 <br />N/A <br />All American Snuffers &Glass <br />Galvanized Steel Storm Panels <br />FL17889.1 <br />N/A <br />6. STRUCTURAL <br />COMPONENTS <br />A. WOOD CONNECTORS/ <br />USP Structural Conn. <br />see chart <br />ANCHORS <br />Simpson Strong -Tie <br />see chart <br />B. TRUSS PLATES <br />ITW Building Components <br />Alpine Truss Plates <br />FL1999.1 - FL1999.4 <br />N/A <br />MiTek Industries, Inc, <br />Truss Plates <br />FL2197.1 - FL2197.5 <br />N/A <br />C. ENGINEERED LUMBER <br />Weyerhaeuser <br />Rim Board, LVL, PSL, LSL <br />FL8527.1 - FL8527.5 <br />N/A <br />D. MATERIAL <br />Cast -Crete Corp. <br />High Strength Concrete Lintels <br />FL158.1 <br />N/A <br />Commercial Concrete Products, Inc. <br />High Strength Concrete Lintels <br />FL1774 <br />N/A <br />e products listed low d' t n review. I understand that t. a time of inspection of these products, the following information must be available to the inspector on the <br />Th prod be id not demonstrate product approval a pia w. at a the p g p <br />jobsite; 1) copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy of the applicable manufacturers installation requirements. Further, I <br />understand these products may have to be removed if approval cannot be demonstrated during inspection. <br />APPLICANT SIGNATURE <br />DATE <br />