My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36046 Stable Wilk Ave
Zephyrhills
>
Building Department
>
Building Plans
>
36046 Stable Wilk Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 10:50:11 AM
Creation date
2/19/2025 11:29:46 AM
Metadata
Fields
Template:
Building Plans
Street #
36046
Location
Stable Wilk Ave
Contractor
Lennar Homes LLC
Building Plans - Permit #
18698
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J <br />12 <br />�(`rYp) SEE ELEV. <br />USP SPT24 @ EA. STUD <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE <br />(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />PLAN <br />(2) 2x HEADER TO SIT <br />2x6 12x8 WALL BEYOND <br />FLUSH TO THE OUTSIDE <br />SEE PLAN FOR HEADER <br />SEE PLAN FOR SIZE <br />CONNECTION <br />2x DEAD WOOD @ MID <br />POINT w/ (3)12d <br />TONEAILS SPACED <br />DOUBLE 2x TOP <br />EVENLY <br />PLATE <br />HEADER FLUSH TO OUTSIDE OPTION <br />2x BLOCKING @ EACH END W/ 10d @ <br />WT4" O.C. FROM EACH HEADER FACE <br />O BLOCKING <br />(2) 2x HEADER <br />PER PLAN <br />2x BOTTOM PLATE W/ (1) 10d @ 8" <br />O.C. TO EACH HEADER FACE <br />2 x 6 (MIN.) FRAME <br />WALL HEADER DETAIL <br />SCALE: N.T.S. SL� <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />DOUBLE 2x4 SPF. #2 <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2) 12d INTO <br />TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />(3)10d TOENAILS T&B <br />AS REQ'D <br />2x BLOCKING @ MID <br />POINT EVERY OTHER <br />+ + STUD W/ (3)10d NAILS <br />PLATE W/ (2)16d TO <br />TRUSS BELOW <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C <br />EDGES & 8" 0/C FIELD <br />USP SPT22 @ EA. STUD <br />2x P.T. PLATE <br />5/8" x 10" "J" BOLT @ 24" O/C MAX <br />W/ 8" EMBEDMENT <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED SOLID W/GROUT <br />1 #5 VERT. IN CONC. FILLED CELL W/ <br />STD. 90^ HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL DETAIL <br />MOUNTING BASE NOT SHOWN <br />FOR CLARITY SEE DETAIL <br />K/S4 <br />SEAT FOR BLOCK IS POURED, <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />GENERALNOTES <br />SLOPE FORWARD <br />FOR DRAINAGE <br />BLOCKING (TYP.) <br />-ROOF TRUSS <br />PLIFT CONNECTOR (SEE SCHEDULE) <br />OISTURE BARRIER <br />SCALE: N.T.S. <br />SEE PLAN FOR FOOTING <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />SCALE: N.T.S. <br />VENT OR 2ND FLOOR <br />1/2" MINIMUM CEMENT FINISH <br />TYPICAL C.M.U. WALL <br />STANDARD 3" DIA. TEE <br />3/4" FURRING STRIPS <br />THREADED 3" DIA. EXTENSION <br />1/2" GYPSUM BOARD <br />SCREW OFF CAP (3" DIA.) <br />W/ DRYWALL SCREWS <br />FOR CLEAN -OUT <br />@ 8" O.C. OR 4d <br />MIN. EXTENSION FROM <br />DRYWALL NAILS <br />EXTERIOR FACE OF BLOCK <br />WALL IS 1 1/2" MAXIMUM <br />EXTENSION FROM EXTERIOR <br />FACE OF BLOCK WALL IS 21 , <br />DRAIN <br />WALL CLEAN -OUT rA <br />SCALE: N.T.S. S4 <br />REFER TO WINDOW PRODUCT APPROVAL <br />SHEETS FOR INSTALLATION INFORMATION BY <br />MANUFACTURER. <br />TYPICAL SECTION THRU WINDOW <br />KNOCK -OUT NOTCH LINTEL WHERE REQUIRED <br />BLOCK WI (1) #5 FOR CONCRETE PLACEMENT J <br />11 <br />° <br />e <br />9 <br />.e d .. a <br />e °- <br />a. .a a e <br />8STD. 90 HOOK 8" <br />LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS <br />GREATER THAN V-0" WIDE (U.N.O. ON <br />PLAN) <br />OPENING <br />FILLED CELL W/ (1) #5 VERTICAL <br />SEE FDN. PLAN FOR LOCATION <br />NOTES: <br />0 FILL LINTEL AND ALL CELLS ABOVE LINTEL, <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />0 VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />PROPERLY. <br />Q3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />® OPENINGS LESS THAN OR EQUAL TO V-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />TYPICAL FILLED LINTEL ASSEMBLY <br />SCALE: N.T.S. <br />WIDTH OF OPENING VARIES 411 <br />FORM CONCRETE INSET TO <br />CREATE A SOLID BASE FOR <br />1/2"X91/2" PLYWOOD <br />BLOCK WALL ABOVE, <br />SCRAP MATERIAL <br />_ a <br />T' <br />W <br />O <br />FORM CREATES CONCRETE RECESS TO <br />2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />MOUNTING BASE SHOWN <br />IN POSITION <br />GARAGE ENTRY FORM DETAIL <br />2x6 MOUNTING BASE <br />SCALE: N.T.S. <br />�8x8x16 C.M.U. <br />GARAGE DOOR TRACK MOUNTING BRACKET <br />GARAGE DOOR ROLLER <br />GARAGE DOOR TRACK <br />CONNECTION ASSEMBLY <br />GARAGE FLOOR <br />TRAVEL DIRECTION OF <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />I <br />° <br />SCALE: N.T.S. ° <br />POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B <br />BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />SHED FORWARD THIS DRAWING. <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />7 5/81, 8" 7 5/81, 8" 7 5/81, 8" <br />SOLID AREAS ARE ❑ <br />❑ STEEL AND GROUT ❑ ❑ <br />INTERIOR <br />WALL q ❑ ❑ <br />CL DOOR OPENING DOOR OPENING <br />EXTERIOR ❑ ❑ ❑ <br />WALL ❑ ❑ ❑ <br />❑F111 ❑ <br />1ST COARSE 2ND COARSE 3RD COARSE <br />MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE <br />COARSE BELOW. EVERY THIRD (3RD) COARSE THE 11" DOOR JAMB WALL IS TO BE <br />WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. <br />MASONRY LAYOUT rD <br />SCALE: N.T.S. S4 <br />VERTICAL JAM <br />SOLID AREAS ARE <br />STEELAND GROUT <br />FULL 8x8x16 BLOCK <br />DOOR OPENING -C <br />5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />BOTTOM CHORD OR 2x4 <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />[TRUSS <br />BLOCKING W/ 2-16d TOE NAILS <br />NOT TRANSFER LOAD. <br />@ EACH END <br />° <br />WALL <br />° ° <br />4 <br />DOOR STOP <br />LU <br />W <br />° <br />° <br />MOLDING <br />_? a <br />° <br />2x TOP PLATE <br />'- U) <br />GARAGE <br />2-16d NAILS @ 24" O.C. OR <br />DOOR <br />Z] <br />EQUAL TO TRUSS BOTTOM <br />CHORD OR BLOCKING <br />2 x 6 P.T. <br />2x STUD @ 24" <br />O.C. MAX. <br />ROVIDE P.A.F. NAILS OR <br />2x P.T. PLATE EQUAL @ 12" O.C. <br />SEE A/S3 FOR STAGGERED FROM BOT. <br />PLATE TO CONCRETE <br />REINF. INFO. W/MOUNTING ANGLE <br />NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL INTERIOR NON - <br />BEARING WOOD FRAME WALL TYPICAL GARAGE DOOR BUCK rK <br />SCALE: N.T.S. S4 SCALE: N.T.S. S4 <br />T�� <br />SFF Ow <br />N <br />2x CRIPPLES @ --� <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />USP SPT4 w/ (6) <br />10dx1Y2"@24" <br />O.C. <br />10d NAILS @ 8"— <br />O/C TYP. <br />DOUBLE 2x <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />SIZE <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />EA END <br />EA END <br />EA END <br />EA END <br />1'-4' <br />(1) <br />(2) <br />(1) <br />(2) <br />(1) USP LSTA30 <br />4'-9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) USP LSTA30 <br />9' -16' <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) USP LSTA30 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"x10" OR <br />GREATER HEADER <br />1R (2) 2x HEADER SEE PLAN <br />S� - INTERIOR HEADER <br />BOX HEADER (1) 2x SILL PLATE W/ (2) <br />ONLY 12d TOENAILS. <br />EXTERIOR HEADERS <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS. OPENING <br />LARGER THAN 4 ft (2) 2x <br />SILL PLATE W/ MP3 CLIPS <br />EACH SIDE <br />'--2x STUDS TYP. <br />USP HTT16 TYP. U.N.O. SEE N/S <br />** HOLD DOWN CONNECTIONS <br />Op'000,4 NOT REQUIRED @ BEARING <br />FNiN� WALLS NOTED WITHOUT UPLIFT <br />P.T. BOT. PLATE <br />WALL HEADER DETAIL Q <br />SCALE: N.T.S. SLI. <br />SPT4 <br />2X STUDS @ 24" O.C. <br />P.T <br />ATE <br />SEE TYPICAL WALL SECTION <br />12 PRE-ENGINEERED WOOD TRUSSES @ 24" O/C <br />(TYP) SEE ELEV. UPLIFT CONNECTOR (SEE SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM C. 926 <br />APPLY 3 LAYERS W/ TOTAL THICKNESS <br />7/8" OVER METAL LATH. FIRST 2 <br />LAYERS 3/8" THICK EACH. 3RD LAYER <br />1/8" THICK. <br />/-CRICKET AS REQUIRED <br />USP SPT24 @ EA. STUD <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d <br />COMMON WIRE NAILS @ 4" O/C <br />BOUNDARIES 6" O/C EDGES & 8" <br />BLOCKING ) <br />O/C FIELD <br />2X4 PT STUDS @ 16" O.C. <br />(2) 2X4 PT STUDS UNDER HIP <br />CARRIER/GIRDER TRUSS <br />USP HTA20 @ EA. STUD <br />MAIN SPAN <br />MOISTURE BARRIER <br />ROOF TRUSS <br />UPLIFT CONNECTOR <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />(SEE SCHEDULE) <br />AND FILLED W/ GROUT <br />1 #5 VERT. IN CONC. FILLED CELL <br />W/ STD. 900 HOOK IN K.O. BLOCK <br />ALT. KNEEWALL ABOVE MASONRY <br />WALL DETAIL <br />PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12)16d NAILS <br />TOP SPLICE <br />2 ROWS 10d @ 3" O.C. (14 <br />NAILS TOTAL) EA, SIDE OF <br />. ' 48ySPLICE STAGGERED <br />ATTACH ALL -' <br />EXTERIOR STUDS <br />W/ 4)16d TOENAILS <br />TO OP PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL rM <br />SCALE: N.T.S. S4 <br />F= 2240 LBS <br />USP <br />USP SPT4—]SPT24 C SPSPT4 <br />--� . <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 <br />AND BB/Si FOR <br />ADDITIONAL DETAILS <br />RECESS <br />LINTEL <br />d <br />INTO <br />TRANSOM <br />FRAMING <br />[USP SPT22 <br />SPT4 USP SPT4 <br />A ° ° 2X81P.T. BOTTOM P TE <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. <br />C (MIN. (2) PER BOTTOM PLATE) <br />USP <br />USP SPT4 <br />SPT24 <br />SP S <br />U <br />S <br />TRANSOM FRAMING <br />SEE SECTION AA/81 AND <br />BB/Si FOR ADDITIONAL <br />DETAILS <br />RECESS <br />LINTEL <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />USP <br />SPT22 <br />SP <br />SPT4 <br />° a <br />° <br />nD I I � <br />2X8 P.T. BOTTOM <br />PLATE <br />I I <br />5/8"xl0" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />SCALE: N.T.S. <br />2X TOP PLATE <br />OVERLAPPING <br />—10d NAILS @ 6" <br />STAGGERED <br />J-BOLTS @ 24" O.C. <br />MAX <br />—2X P.T. PLATE <br />TRUSS ABOVE <br />% - 2X BLOCKING <br />O <br />-(2) 16d TOE NAILS <br />EA. BLOCKING <br />' 2X8 WALL ABOVE <br />ENTRY <br />K.O. BLOCK W/(1) <br />#5 CONT, & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'4' O.C. <br />MASONRY WALL <br />PT4 <br />10d NAILS @ 4" 10d NAILS @ 6" O.C. <br />STAGGERED A STAGGERED <br />TRANSOM FRAMING <br />0 o BEYOND. <br />L.PLYWOOD <br />PLYWOOD FASTENED TO TRUSSES o E SHEATHING <br />WITH 8d COMMON WIRE NAILS @ 4" S4 <br />O/C BOUNDARIES 6" O/C EDGES B <br />& 8" O/C FIELD <br />PLYWOOD <br />SHEATHING <br />MASONRY <br />SP WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. <br />PT4 MAX. (MIN. (2) PER BOTTOM <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY R <br />SCALE: N.T.S. S4 <br />U(_L2 <br />Z M <br />0 <br />ID <br />Z <br />z <br />a <br />- I <br />60 Z <br />IDVJ cn <br />4--J w <br />�_ p <br />•U <br />— <br />0 LL, <br />Tm <br />E <br />CLI rV !J <br />rr^^ , ~ <br />v <br />to <br />o O <br />�mr <br />U <br />QM <br />W <br />E <br />min - <br />c� N M <br />N 6 M <br />O o0 <br />2 ai <br />Ua) <br />r- U_ ao <br />1� <br />(0Qo <br />Q rn <br />U) o q. <br />a <br />A <br />B <br />1 <br />D® <br />N•C B D C <br />� 0 <br />g444"' l <br />. <br />:O <br />f b.- 4 'e- <) <br />g ; :� <br />` 0 <br />21, QZF <br />r .• <br />S\ C) � <br />To the best of the Engineer flb e, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z N <br />O 2 I, <br />f> rn <br />Q "M Ln <br />a_ Ln <br />U_ <br />zCL <br />IQ- <br />ce V CL 00 <br />Qz <br />� <br />Z � <br />WI- <br />C J <br />�R <br />w� <br />za <br />�a <br />r~ <br /><Wx <br />gQBo <br />ul <br />z 0 <br />y�y � <br />R 2 0 J <br />LL N <br />8 Lu <br />W <br />I-WQ <br />o� <br />ZZ <br />¢e <br />LO <br />�Z <br />5 <br />z <br />-0 <br />cp <br />L <br />o <br />> <br />(V <br />o <br />Z <br />u <br />Cl) <br />Q <br />oLL <br />¢<UR70 <br />ANJ <br />0 rF <br />w <br />a� <br />UaR <br />N <br />I� <br />Z°doa <br />J <br />�Z< <br />Q <br />��Wa <br />Z <br />LIJ <br />Noco, <br />Ln <br />W <br />(, 2 Z <br />a LL <br />J <br />Q <br />E a <br />O <br />l0 <br />00 <br />Q <br />Z <br />Z <br />cc <br /><tz <br />aLn <br />N <br />LU <br />Z <br />az <br />O <br />g <br />= <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: ERAND <br />VERSION N0. 10 <br />SHEET NO. <br />S4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.