ELECTRICAL SPECIFICATION <br />zooAlCENTE <br />PANEL <br />CENTER <br />NOTES: <br />111, #15 copper to lights & outlets <br />ELECTRICAL CONTRACTOR <br />NEMA 1 #12 copper to 20 amp ckts <br />200HMP <br />MUST VERIFY WITH THE <br />01 #10.2 to wH <br />SPECIFICATIONS FOR THE TYPE <br />#10-3 copper to Dryer <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />METER <br />LOCATION PURPOSES. <br />MAINT <br />200 amp <br />/0 or 4/0 SER Alu <br />150amp <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible, <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />I <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />177111 <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />A. <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;0+ <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />0 <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKEICARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(9D <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 <br />4 Bare Cu Ground <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />VERIFY METER <br />LOCATION WITH <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"= V-0" <br />UI to <br />zo <br />O <br />z� <br />N <br />z <br />Q <br />CL <br />z <br />nV) <br />C(aW C <br />DlU <br />4--J w <br />n <br />— <br />OLU <br />Vi <br />O <br />o Mo <br />U <br />mr- <br />0, M <br />LLI <br />♦— O <br />all U <br />C 0) M <br />W a M <br />O 20 <br />T 0) <br />cl) <br />U <br />L LL 0D <br />0 <br />� <br />Y <br />Qe <br />to O d <br />Q 0 <br />rn�o <br />A , <br />N-C f <br />D,C <br />r_ <br />O <br />N <br />CID <br />CID <br />� N <br />�r to <br />t9 yo�o°' �_ <br />C V <br />° ° <br />Z W t,NZ <br />M <br />0 <br />t1. z <br />J <br />to L C <br />A/ i� = LL O <br />a U) <br />LL LL. <br />"i CCj7 N <br />QW <br />' VQa�$ <br />Q. W <br />Z?yz <br />iO <br />t9yW064 <br />g Ems? <br />IL <br />mm <br />W aNaM 02-8 <br />Jo <br />O U <br />0 <br />V <br />El El <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z N <br />O a� n <br />� �O <br />>�Mo <br />Q��L <br />n. <br />� <br />Q LL <br />ZF_ C>)- ,, M <br />V fa <br />< <br />§ E <br />fa <br />Z <br />_j� <br />LU <br />d' <br />01 <br />�o <br />W� <br />Z <br />f a <br />Z <br />o°d <br />Jo�.ao <br />Z Q W 4 <br />= 0 w Z <br />J <br />Q <br />�22J <br />LO <br />g � <br />U <br />W N <br />�W© <br />-1 <br />Q to <br />Z Z <br />y- <br />H <br />Qo <br />� Z <br />H <br />O <br />W <br />g <br />4� <br />Lf) <br />w <br />o <br />; <br />N <br />_ <br />to <br />0 <br />LL <br />; < <br />Lu <br />'o u- <br />¢�OZ <br />H <br />z. <br />—I <br />mZ Uxo <br />Ooa' <br />O <br />N <br /><o <br />Q <br /><Qw� <br />Z <br />oQ_�oN <br />a(DZ <br />J <br />2:Q <br />0Zo <br />iLia <br />O <br />� <br />Q <br />Z <br />Z <br />WLu IZ < ce <br />az <br />�O <br />m <br />O <br />t,--I` <br />4Z <br />J <br />= <br />¢ z <br />uj <br />a <br />cn <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: ERAND <br />VERSION NO. 10 <br />O <br />SHEET NO. <br />4.0 <br />