Laserfiche WebLink
M <br />NO <br />M. <br />8"x8" SMOOTH <br />TEXTURES CORBELS - <br />1" x 9" SMOOTH <br />TEXTURED 12 <br />FREEZE BAND 5� <br />HEEL <br />1" x 4" SMOOTH <br />TEXTURED <br />HEAD/BAND _ <br />T.O.M. — <br />HDR HGT. <br />12 <br />5� <br />12 <br />u u u u U 3 TAB SHINGLES. ROOF <br />12 �— - - — r INSTALLED AS PER MANUF. <br />�5 SPECIFICATIONS <br />- 1' 0" <br />--------- -- - - - - - - - - --�- -- -�--- <br />14'-0" RIDGE VENT <br />FE-1 El Fp--� FL_�] El F7 ",X-- VX9. SMOOTH <br />TEXTURED <br />Ell 1:1 M 1:1 FL-71 F7� FL-7] 0 <br />12 <br />;Z�5 <br />7'-0" RIDGE VENT <br />2" <br />PROFILE ELEVATION <br />� DECORATIVE SILL <br />FRONT ELEVATION - B <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />— T. T.O.M. <br />N <br />SCALE: 1 /4"=V-0" <br />LEFT ELEVATION - B <br />: 1 /4"=1' <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion o <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN* <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT. <br />*If not enough vented soffit is provided due to fire protection, the contractor shall use the <br />following approved vents: <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) 19 = Linear Ft. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT <br />"Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) 186.25 = Amount of D'Hagin Vents Needed <br />UI' <br />z <br />0 <br />0 <br />— o <br />N <br />z <br />� <br />O <br />J <br />C <br />uJ <br />�V — <br />O LU <br />E <br />0 <br />(n <br />"o <br />In <br />o <br />For- <br />tLJ <br />a) M <br />CMM <br />F® E <br />®c0i <br />@ '0 co <br />Ooo <br />f= N <br />I U <br />L LL <br />N <br />Y <br />fn Q- O <br />tr) O V <br />Q rn <br />rn Q o <br />�D-C <br />B D®� <br />r A. <br />ie ��; co <br />m.� (� "' <br />Z� „LIL <br />N 1 CL <br />-� <br />,a14 <br />m °' ¢' o <br />OR� <br />O <br />Z z m m Qt;CF <br />W <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />0 <br />0 <br />Z N <br />O N n <br />t--r :a_+ p <br />I>i U M O <br />a�fOL0 <br />QL_ I� Ln <br />c" <br />f. - . M <br />C(_U Q00 <br />a <br />E <br />`a <br />z <br />WLLJ <br />J C:) <br />d" <br />OZ <br />= O <br />Q <br />z a <br />f 4 <br />F <br />W <br />ejQ-a <br />00 <br />Z <br />OE U <br />z UJ w <br />O <br />0 W z <br />�(�7 <br />W <br />J <br />FL 2' 00- <br />0 <br />O cc O <br />W <br />!} <br />LU <br />cc <br />Fwo <br />O <br />V, <br />W <br />Z <br />o <br />7z <br />JJ <br />T <br />W <br />-w <br />z <br />O <br />_00 <br />� <br />4 3 <br />fo <br />M <br />F <br />> <br />C:z <br />M8 <br />O <br />U <br />(n <br />ru <br />Q <br />�¢ <br />aoOZ <br />0 <br />J <br />z <br />O <br />W 2On <br />V J <br />N <br />r1 m <br />Zwoa <br />J <br />lwcLJL Q <br />Q <br />uJ <br />Q F � Q <br />$w <br />Z <br />Z <br />N <br />W <br />Wa R <br />�a-0 <br />J <br />di <br />57 <br />owo <br />i x a <br />0 <br />Q <br />Q�z <br />*k <br />Z <br />a Z <br />J ° <br />m <br />O <br />g <br />= <br />Qz <br />rn <br />---i <br />a <br />cn <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: FFLORES <br />VERSION No' 10 <br />SHEET NO. <br />3.1 <br />