Laserfiche WebLink
orwaFl-r+" I <br />ROOF FLASHING AND ROOF FLASHING <br />COMPONENTS TO BE IN ACCORDANCE <br />w/ R903.2, FLORIDA BUILDING CODE <br />7TH EDITION (2020) RESIDENTIAL <br />12 <br />I <br />INSULATION - <br />BAFFLE <br />INSULATION PER - <br />CHART ON FLOOR <br />PLAN <br />5/8" OR 1/2" HIGH STRENGTH CEILING <br />BOARD PER CODE W/ 1 3/8" DRYWALL <br />NAILS OR DRYWALL SCREWS 7" O/C / <br />CEILING & 8" O/C WALLS / <br />1/2" GYP WB / <br />DOUBLE 2x S.P.F. TOP PLATE - ATTACH 2x STUDS J <br />TO TOP PLATE w! (1) SIMPSON SP2 TYP. @ <br />CORNERS, SP2 MAY BE SUBSTITUTED W/ (1) H2.5A <br />2X BLOCKING @ EA. WALL <br />SHEATHING JOINT <br />16" O.C. 2X S.P.F. STUDS <br />2x BOT. PLATE W/ (2)10d @ 6" O.C. <br />3/4" PLYWOOD DECKING GLUED AND NAILED W/ 10d <br />COMMON @ 6" O/C EDGES AND 12" O.C. FIELD <br />1/2" GYP. WB OR 318" PLYWOOD/ TYPE 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/8d <br />COMMON @ 6" O/C TO ONE SIDE OF THE FLOOR TRUSS FOR <br />AN AREA 51000 SQ. FT. OF FLOOR AREA & SEALED <br />PENATRATION AREA W/ FOAM. DRAFTSTOPPING SHALL <br />DIVIDE THE CONCEALED SPACE INTO APPROX. EQUAL <br />AREAS. ID <br />FLOOR SYSTEM <br />// <br />ERPLAN <br />1/2" HIGH STRENGTH OR 5/8" GYP WB (OR 5/8" - <br />GYP. TYPE " X" @ GARAGE ONLY) W/ 1 3/8" <br />DRYWALL NAILS OR DRYWALL SCREWS 7" O/C <br />CEILING & 8' O/C WALLS <br />1/2" GYP WB <br />INSTALLATION PER <br />CHART ON FLOOR PLAN <br />NOTE: LAP SHEATHING TO BOTTOM OF <br />BAND JOIST TYPICAL <br />FOR UNDERLAYMENTCD STD. 90 HOOK (SEE DETAIL) <br />REQUIREMENTS SEE R905.1.1 <br />PRE ENGINEERED WOOD TRUSS @ 24" O.C. MAX. <br />HURRICANE ANCHOR @ EACH TRUSS <br />SHINGLE ROOF, SHINGLES TO BE IN <br />ACCORDANCE w/ ASTM D7158-CLASS G or <br />H, or ASTM D3161-CLASS F, IN <br />ACCORDANCE wl TABLE R905.2.6.1, <br />FLORIDA BUILDING CODE 7TH EDITION <br />(2020) RESIDENTIAL <br />ROOF SHEATHING -SEE <br />SCHEDULE - [RSH] - ON <br />FRAMING SHEET FOR <br />SHEATHING AND FASTENERS <br />ALUMINUM DRIP EDGE <br />ALUMINUM FASCIA <br />2x SUB FASCIA <br />SEE STRUCTURAL SOFFIT SHEET SS <br />ATTACHED WALL SHEATHING TO <br />(2) TOP PLATE W/ 8d @ 4" <br />O.C., 2 ROWS <br />1x2 NAILER <br />~ <br />PLYWOOD SHEATHING <br />NAILED PER NAILING SCHEDULE SEE DETAIL C/S6 <br />FOR MORE INFO <br />w <br />o = <br />7!8" CEMENTIT►OUS FINISH PER ASTM C. 926 <br />APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER <br />METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD <br />J I— <br />LAYER 1/8"THICK. <br />L=L w <br />INSULATION PER <br />CHART ON FLOOR PLAN <br />B R <br />��S6 <br />ETAL SEAT <br />OR FELT <br />- <br />PAPER FOR <br />MOISTURE <br />BARRIER <br />8"x8"X16" CONC. KNOCKOUT <br />BILK. W/1#5 ROD CONT. FILLED <br />SOLID W/GROUT <br />-ARCHITECTURAL <br />FINISH <br />(1) #5 VERT. IN FILL CELLS (SEE <br />FOUNDATION PLAN & NOTES) <br />CO) <br />v 4"x4" INSPECTION PORT AT <br />w CO EACH FILL CELL TYPICAL <br />tx WD FURRING @ 24" O.C. a AT GARAGE CONTRACTOR <br />BASEBOARD N TO CUT BLOCK OR POUR <br />MIN. 2500 PSI CONC. SLAB CURB DUE TO SLOPE <br />MIN. PSI MAY VARY PER NOTE: EXTEND DECO FINISH <br />MUNICIPALITY 4"to 6" BELOW GRADE <br />c 4. .... <br />NA-..E r- FINISH GRADE <br />� . G w <br />C1) - <br />6x6 W1.4xW1.4 - - - -' .- <br />WWF OR FIBERMESH _ <br />17 <br />.- <br />�-STD. (3) # 5 REBAR ON 3" CHAIR (SEE DETAIL) <br />W/3" MIN. CLEARANCE 4" V-8" <br />TYP 2-STORY WALL SECTIONC-i <br />REV.03.16.21 SCALE:3/4"=V-0" S6 <br />c0 <br />SIMPSON LSTA24 STRAP w/ (8)10d x 1 1/2" NAILS TO <br />2nd FLO <br />BEAM/GI <br />2ND FLOOR FRAME CONNECTION <br />SEE J/S-6 FOR ADDITIONAL INFORMATION. <br />SIMPSON LSTA24 STRAP w/ (8)1 Od x 1 1/2" <br />NAILS TO STUD & (8)1 Od x 1 1/2" TO BAND <br />JOIST AT EA. STUD e <br />/2nd FLOOR WALL------- <br />*SIMPSON LTP4 w/ <br />(12) 8d x1 1/2" NAILS <br />@ 24" O.C. <br />1st FLOOR WALL— <br />SIMPSON LSTA24 STRAP W/(8) 10d x 1 1/2" <br />NAILS TO STUD & (8)10d x 1 1/2" TO BAND — <br />JOIST AT EA. STUD <br />2ND FLOOR FRAME CONNECTION <br />@ WOOD 1ST FLR. <br />UPLIFT CAP = 928 PLF <br />SHEAR CAP = 355 PLF <br />SEE J/S6 FOR ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />SCALE: N.T.S <br />SPACER <br />BLOCKS <br />-END SHEATHING TO <br />)F BEAM OR GIRDER <br />ATE W/ <br />O.C. <br />)OR TRUSS/JOIST <br />2"x BOT. PLATE W/ <br />(2)10d @ 6" O.C. <br />NOTES: * USE <br />LTP4 & EXTEND <br />SHEATHING TO <br />BOTTOM OF RIM <br />BOARD/BAND <br />JOIST FOR <br />SHEAR WALL <br />ONLY. <br />"T" CORNER <br />TYPICAL'IT" AND CORNER <br />DETAILS rN <br />SCALE: N.T.S. S6 <br />E <br />S6 <br />2ND FLOOR FRAMING - SEE <br />SECTION J/S6 <br />DECKING ATTACHED WALL SHEATHING <br />TO BOTTOM PLATE/CHORD W/ 8d <br />@ 4" O/C, 2 ROWS STAGGERED <br />FLOOR TRUSS SEE FRAMING PLAN <br />FLOOR TRUSS <br />°O <br />SEE FRAMING WEEP SCREED <br />4 z <br />PLAN INSTALLED PER MANUF. <br />2"x4" CROSS BRACE @ 48" SIMPSON HETA20 w/ (8)10dx1 1/2" <br />O/C FOR THE 1 ST 2'-0" OF I I NAILS @ 24" O.C. INTO TRUSS <br />END WALL W/ (2)10dx3" @ EA. BLOCKING & MIN. 4" EMBEDMENT <br />END INTO 2"x4" BLOCKING IN KO BLOCK <br />SEE DETAIL 2/D2 FOR <br />MORE INFORMATION <br />2ND FLOOR FRAME CONNECTION R <br />PARALLEL TO MASONRY WALL SCALE: 3/4"=V-0" S6 <br />SEE TYP. 2-STORY WALL SECTION <br />FOR ADDITIONAL INFORMATION. <br />2x STUDS @ 1 <br />2"x BOT. PLATE <br />(2)10d @ 6" 0.( <br />PRE-ENGINEE <br />FLOOR TRUS: <br />ATTACHED WALL SHEATHING <br />CONTINUOUS TO BOTTOM RIBBON <br />W/ 8d @ 4" O.C., 2 ROWS STAGGERED <br />2X4 RIBBONS, EACH W/ 4-16d <br />NAILS INTO EA. FLOOR TRUSS <br />u <br />WEEP SCREED <br />INSTALLED PER. MANUF. <br />SIMPSON HETA20 w/ (8)1 Odxl 1/2" <br />NAILS AT EA. TRUSS wl MIN. 4" <br />EMBEDMENT IN KO BLOCK <br />FLOOR CONNECTION B <br />@ MASONRY 1ST FLR. SEE J/S6 SCALE: 3/4"=V-0" S6 <br />FOR ADDITIONAL INFORMATION. <br />TR <br />RIBBONS <br />DETAIL FLOOR TRUSS 0 <br />SCALE. 1 1/2 =1' S6 <br />NOTE: SEE TYPICAL WALL SEE SHEATHING <br />SECTION C/S3 FOR SPECS ON FLOOR <br />ADDITIONAL INFORMATION <br />1/2" GYP. W.B. MIN. @ <br />2x BLOCKING HORIZONTALLY GARAGE SIDE IF APPLICABLE <br />@ INTERVALS NOT 5/8"DIA. x 10" "J" BOLT W/ 8" <br />EXCEEDING 10'-0" (R302.11) EMBEDMENT @ 24" O.C. W/ <br />SIMPSON SP1 w/ (10)1Od 2"DIA.X 3/16" PLATE WASHER <br />NAILS AT EA. STUD (MIN. SHEAR 3500#. MIN. <br />2 x STUDS @ 16" O.C. TYPICAL TENSION 2600#.) <br />2X P.T. PLATE 6 x 6 W1.4 x W1.4 WWF OR FIBERMESH <br />-r=� — <br />r.6_k.. 4 . ° -. • . . I �. <br />.. 4, . io <br />T <br />O <br />—I Irjjj-j [j[J r (3) #5 CONT. ON 3" <br />8" 1'-8" r 8'1 CHAIR W/ 3" MIN. <br />CLEARANCE <br />INTERIOR 2-STORY FRAME SECTION rs <br />SEE TYP. 2-STORY WALL SECTION FOR SCALE: 3/4"=V-0" S6 <br />ADDITIONAL SLAB INFORMATION. <br />15 <br />EXPOSURE <br />REI <br />41 <br />SHEATHING <br />x <br />--x <br />PROVIDE <br />BLOCKING AS <br />REQUIRED PER <br />D <br />a SECTION X-X IF <br />NOT FULL <br />HEIGHT SHEET <br />C I II <br />Z_ <br />G FLOOR SYST <br />M <br />f(2)- Zx TOP PLATE <br />BEYOND I <br />OSB <br />EXPOSURE 1 <br />F <br />SHEA <br />SHEATHINHIN G <br />2 <br />SOLID 2x <br />o <br />C <br />II II <br />II <br />II <br />BLOCKING @ ALL <br />C <br />SHEATHING <br />y <br />EDGES (SEE <br />III <br />OPENING <br />SECTION <br />a. U <br />D <br />x <br />Fxw <br />cs <br />11 <br />x <br />E <br />W <br />2x STUDS <br />III <br />III II <br />II II <br />BEYOND. <br />y <br />SEE PLAN <br />O <br />�I <br />III <br />y <br />" --2x4 P.T. BASE <br />2x RIBBON OR -'VERTICAL A HORIZONTAL PLATE BEYOND <br />BLOCKING SEE PLAN <br />BETWEEN FLOOR WALL SHEATHING <br />SYSTEM WALL ELEVATION DIAGRAM <br />3/8" "S" = NAIL 3/8" <br />SPACING <br />S 314" S 1/2" <br />7� • 1l2 <br />S 1/2„ <br />SINGLE NAIL EDGE SPACING DOUBLE NAIL EDGE SPACING <br />AT ALL PANEL BLOCKING <br />LOCATIONS SHALL BE MIN 2x4 tit <br />STURNED VERTICAL w/ 7/16" <br />FLITPFCH PLATE TO w/ (2)12d <br />TOENAILS EA. END. NAIL FLITCH <br />PLATE TO VERTICAL w/ (4) 8d NAILS <br />(2) 8d NAILS @ 3" O.C. <br />STAGGERED FOR SHEATHING <br />v -V` a 6— <br />SECTION X-X <br />SF p/NOO�,y <br />�N <br />2x CRIPPLES @ - <br />16" O.C. W/ (2)12d <br />TOENAILS TB <br />10d NAILS @ <br />8" O/C TYP. <br />DOUBLE 2x — <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />WALL SHEATHING MAY BE INSTALLED VERTICALLY OR HORIZONTALLY, <br />ATTACH PER NAILING SCHEDULE. PANEL EDGES WILL NEED TO BE <br />ATTACHED TO STUD AND OR BLOCKING AT ALL EDGES. A MINIMUM }S' <br />SPACE IS RECOMMENDED BETWEEN PANELS AT EDGES AND END <br />o <br />w <br />JOINTS TO ALLOW FOR EXPANSION. FASTENERS SHALL NOT <br />PENETRATE SURFACE MORE THANE". <br />z <br />OA NAIL AT BASE 2 ROWS @ 4" O.C. wl 8d COMMON NAIL <br />O <br />@ NAIL AT TOP PLATE TWO ROWS @ 4" O.C. w/ 8d COMMON NAIL <br />Z <br />LL = <br />@ NAIL OPENING PERIMETER w/ (2) ROWS @ 4" O.C. w/ 8d COMMON NAIL. <br />O <br />OD NAIL INTERIOR AT 6" O.C. w/ 8d COMMON NAIL. <br />u=) <br />O STAGGER ALL VERTICAL JOINTS & NAIL @ 4" O.C. <br />J o <br />w/ 8d COMMON NAIL <br />w LL LU <br />O <br />PLYWOOD SPLICES @ HEADER - NAIL SHEATHING TO HEADER <br />O <br />� rO $ y <br />w/ 8d COMMON NAILS @ 4" O.C. (2) ROWS @ TOP & BOTT. <br />ri F m LL a <br />@(2) 8d NAILS @ 3" O.C. TO EACH TRUSS END OR @ VERTICAL <br />- N w O OLL ~ <br />tr <br />MEMBER IF GABLE END <br />LL <br />NOTE: <br />C WALL SHEATHING INSTALL. <br />S6 & NAILING SCHED. <br />REVISION 12-7-2020 <br />• 8d NAILS FOR WALL SHEATHING MUST BE MIN. 13 1 <br />X 2 1/2 <br />• DO NOT OVERDRIVE NAILS, FASTENERS SHALL NOT PENETRATE <br />SURFACE MORE THAN 1/8". <br />2-ROWS 12d NAILS <br />STAGGERED @ 12" O/C EACH <br />FACE OR 3-ROWS 12d NAILS <br />4 <br />STAGGERED @ 12" O/C FOR <br />2"xl0" OR GREATER HEADER <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />(2) 2x HEADER SEE PLAN <br />S4 <br />INTERIOR HEADER: <br />BOX HEADER <br />(1) 2x SILL PLATE W/ (2) <br />ONLY <br />12d TOENAILS <br />• EXTERIOR HEADERS: <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(1) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6)10d x 1 1/2" EACH SIDE <br />2x STUDS TYP. <br />P.T. BOT. PLATE <br />FLOONn?/0, i BEAM <br />TRUSS <br />/ <br />SEE PLAN FOR REQUIRED ---- <br />CONNECTIONS <br />LOAD BEARING/EXTERIOR FRAME <br />WALL HEADER DETAIL <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />JACKS I <br />STUDS <br />JACKS <br />STUDS <br />SIMPSON <br />SIZE <br />EA END <br />EA END <br />EA END <br />EA END <br />1' 4' <br />1) <br />2 <br />1 <br />2 <br />(1) LSTA30 <br />4'-9. <br />(2) <br />3 <br />(2) <br />(2) <br />(1) LSTA30 <br />9'-16' <br />(3) <br />3 <br />(2) <br />(3) <br />1 (2) LSTA30 <br />PLYWOOD SHEATHING NAILED PER NAILING <br />2x BLOCKING HORIZONT <br />SCHEDULE SEE DETAIL C/S6 FOR MORE INFO <br />@ INTERVALS NOT <br />EXCEEDING 10 -0 (R302.11) <br />2X STUDS @ 16" 0!C <br />5/8"DIA. x 10" "J" BOLT W/ 8" <br />7/8" STUCCO FINISH PER ASTM C. 926 <br />EMBEDMENT @ 24" O.C. W/ 2"DIA. <br />APPLY 3 LAYERS W/ TOTAL THICKNESS <br />x 3/16" PLATE WASHER (MIN. <br />7/8" OVER METAL LATH. FIRST 2 LAYERS <br />SHEAR 3500#. MIN. TYPICAL <br />3/8" THICK EACH. 3RD LAYER 1/8" THICK. <br />TENSION 2600#.) <br />SIMPSON SP1 w! (10)10d NAILS <br />AT EA. STUD <br />2500 PSI CONCRETE MIN. <br />SLAB W/ 6x6 W1.4xW1.4 <br />2X P.T. PLATE <br />WWF OR FIBERMESH <br />WEEP SCREED INSTALLED PER. MANUF. <br />C <br />. • ♦ .. w <br />00 <br />- ' . " <br />FINISH GRADE <br />M-1II_III_III_II <br />_ <br />I I=1 I I=1 11 <br />11 <br />4 ... <br />_ <br />11 I <br />_ <br />-1 <br />.- .: <br />T <br />I_I <br />I I <br />- �• I <br />_I <br />I_I 111; <br />q <br />-III <br />•. ,I <br />- <br />III- <br />(3) # 5 REBAR ON 3" CHAIR 4" V-8" I <br />W/3" MIN. CLEARANCE <br />ALTERNATE FOOTING V <br />@ WOOD 1 ST FLR. SEE JlS6 FOR SCALE: 3/4"=1'-0" <br />ADDITIONAL INFORMATION. S6 <br />era <br />N <br />C= <br />N <br />c <br />o <br />-o <br />0.. <br />sr o <br />C Cv V N <br />m <br />�LLa <br />W O a <br />d N <br />Q <br />3= °iY <br />IEc <br />C <br />d U s Q <br />a 3 cc <br />is <br />� c o <br />s� <br />In E <br />c <br />co 0 <br />a <br />0 <br />w <br />,•�,t1s36� Ittrrrrr�,e <br />0 VV N <br />` J <br />zz <br />•, <br />F <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />E <br />M8 <br />v <br />0 <br />Loo <br />`1 60 <br />• -2i <br />NU,, �- <br />N 6, qp " <br />0 <br />M <br />0 <br />C <br />li LL W <br />9 LL W D <br />.L <br />=-dam a Y <br />ClFe <br />W <br />C� <br />0 <br />Z <br />IL <br />co <br />o r Z d <br />N - <br />OU y <br />z <br />� <br />z N <br />Z <br />z <br />a <br />10 <br />N <br />- N <br />M <br />z M <br />U <br />u- <br />'ry <br />c/) <br />cl <br />0 <br />v) <br />LU <br />c <br />�N <br />(a <br />A <br />I— t i <br />w <br />L <br />= <br />U <br />if <br />— <br />0 <br />Cj co <br />m <br />M <br />_') <br />p <br />W <br />z <br />�°`e <br />Eo <br />;= <br />$v <br />z <br />UO <br />U <br />z <br />O <br />O <br />CO <br />o0 <br />a z <br />O- <br />w z <br />�8 <br /><O <br />W <br />@ <br />�z <br />Y <br />mE <br />O <br />ON <br />zC <br /><�Z <br />3 <br />N <br />T <br />80 <br />o <br />az <br />m W <br />W <br />m <br />¢¢ <br />j 0 <br />yLL <br />F <br />z <br />pO <br />za <br />a <br />.� <br />C <br />o <br />T <br />y <br />L6 <br />O <br />N <br />m <br />c� <br />cQ <br />Q <br />0 <br />cc <br />�.. <br />m <br />3: <br />Ln <br />r <br />(D <br />I� <br />.� <br />0 <br />ca <br />04 <br />N <br />T <br />r <br />Q <br />4 <br />E <br />N <br />M <br />Z <br />E <br />W T <br />a <br />U <br />JOB <br />NO : <br />23-00501 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S6 <br />(MONO) <br />