My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36345 Flats St
Zephyrhills
>
Building Department
>
Building Plans
>
36345 Flats St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 2:39:59 PM
Creation date
2/19/2025 11:31:25 AM
Metadata
Fields
Template:
Building Plans
Street #
36345
Location
Flats St
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknow
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3/8" CEMENT <br />PLASTER <br />12 MIL DRYLOK CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />1)SEALANT AT <br />4 SEALANT JOINT <br />WINDOW BUCK TO <br />OUTSIDE EDGE OF <br />MASONRY <br />WINDOW BUCK <br />2) SEALANT JOINT <br />5) SEALANT FROM <br />INSIDE EDGE OF <br />WINDOW FRAME <br />WINDOW BUCK <br />ACROSS WINDOW BUCK <br />.. <br />AND EXTEND TO <br />WINDOW FRAME <br />MASONRY <br />ATTACHED <br />PER CODE <br />6) TOOLED SEALANT <br />REQUIREMENTS <br />BEAD BRIDGING <br />CLADDING AND WINDOW <br />FRAME <br />3) SEALANT WINDOW FRAME T( <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SILL. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />"V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />SCS 06_02 WINDOW FIN INTERFACE WITH <br />EXTRUDED SHOULDER <br />WEATHER <br />RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTI( <br />1, Cut, fold up & temporarily secure <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />\ <br />TEMPORARILY SECURE <br />WOOD FRAME CONSTR. <br />EXTERIOR <br />SELF -ADHERED FLASHING <br />SHEATHING <br />BY LAPPING DOWN <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />:-ADHERED FLASHING <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL r 1 <br />COMPATIBILITY V <br />SELF -ADHERED FLASHING <br />WEATHER RESISTIVE <br />BARRIER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4%1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />L`3 SECTION -A (SEE DETAIL WP02) <br />4 <br />SELF -ADHERED FLASHING <br />2 <br />SELF -ADHERED FLASHING <br />NAILING FLANGE 1 <br />DO NOT FLASH OVER SEAL TOPS OF JOISTS <br />BOTTOM NAILING 8 UNDER DECKING <br />FLANGE (SEE DETAIL WP07) <br />SELF -ADHERED FLASHING SELF -ADHERED FLASHING <br />HALF ROUND WINDOW E ME EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the number marked as in each detail that corresponds to the <br />numbered items in the list o instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3.. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />rL,r+onnvv <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />r�r+onnvv <br />2x FRAMEWALL <br />TILE FINISH- <br />1/2" DUROCK- <br />8" CMU <br />4"OR8"CMU <br />(PER SEAT DEPTH) <br />FILL WITH GROUT - <br />SLOPED MUD BED <br />VINYL SHOWER PAN <br />St 0PE <br />a <br />M <br />a <br />V-4" PER PLAN <br />V-0" PER PLAN <br />SHOWER SEAT <br />a <br />J <br />711 <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />Q <br />w <br />U) <br />m <br />d <br />2 <br />WINDOW UNIT FLASHING REQUIREMENTS <br />DOOR ROUGH OPENING SLOPE <br />0.3 in: 12.0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />(0.6 cm: 30.5 cm) include flashing as described in Section R703.4. <br />- 3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6". USE LIQUID R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of <br />NAIL BRAND OR EQUAL WEATHER EXTERIOR PROOF CAULKING CEMT. FIN. water within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means <br />SELF -ADHERED FLASHING BUILDING PAPER Of draining t0 the exterior water that penetrates the exterior Cladding. <br />WIRE LATH R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or <br />sUBFLOOR other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied <br />horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 <br />= inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The <br />RIM JOIST No. 15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and <br />building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />1 R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over <br />wood -based sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade <br />2 Q D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING <br />m <br />CEMT. FINISH SILU POTSHELF/CHIMNEY SHOULDER Amm <br />Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT substantially nonwater-absorbing layer Or designed drainage space. <br />RUBBERIZED <br />INSTALL SELF -ADHERED NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />FLASHING JAMB & HEAD THROUGH SELF -ADHERED R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be <br />FLASHING, SEE FLASHING SELF -ADHERED FLASHING applied shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied <br />FLANGED �wP01) membranes used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to <br />SCORED prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />SELF -ADHERED FLASHING, (BEFORE FOLDING, SCORE the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />VERTICALLY <br />AMINIMUM 6" READ ESIVEASSHOWN)EASE PAPER TO contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />VERTICALLY FROM <br />BOTTOM OF flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />THRESHOLD shall be installed at the following locations: <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following: <br />5 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />4 manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />1 6 are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for <br />2 7 subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />SELF -ADHERED FLASHING 1.3 1.3. In accordance with other approved methods. <br />1 INSIDE CORNER , 1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground7 3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />1 6.6.At wall and roof intersections. <br />Water Resistant Barrier 7. 7•At built -In gutters. <br />LF-ADHERED FLASHING <br />TCH <br />HERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />:5 :5 <br />a- o- <br />UJL PLASTER STOP <br />_ � CONTINUOUS BACKER <br />LV <br />LU ROD & SEALANT <br />w <br />� w <br />d � <br />w <br />�° A <br />c <br />a <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />THIS GAP IS A RESULT OF <br />NATURAL SHRINKAGE. <br />DO NOT SEAL. <br />DRIP SCREED PLASTIC <br />ACCESSORY <br />SOFFIT/CANTILEVER <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) -a o <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) - - <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING,'OSB% PLYWOOD, DENSGLASS <br />ACKER ROD <br />A <br />FINISH <br />STRUCTURAL FRAMING <br />STRUCTURAL SHEATHING <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />- Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2"to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or Sim. <br />caulk for all <br />eY'3 <br />cV <br />+I� <br />v <br />CID UJ <br />w <br />C. a <br />covQ <br />-„mom <br />6p p cc <br />Q C3 CV <br />�. lRJ <br />ax <br />oa �� <br />c <br />CO <br />Q <br />M <br />0 <br />N <br />cap <br />N <br />�t <br />0 <br />e <br />� <br />a <br />a <br />a <br />a Is '�tl f r- r. is •^l'.'9 rvy�i <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />f) <br />W E <br />o <br />4 8 <br />0 <br />Lo 5 N W co:N r <br />i 0 <br />7�co 0) <br />p0 <br />co J <br />W <br />co o <br />JELL <br />W <br />Z_ -?aa <br />o o <br />i : t6N�R_ <br />� zYz <br />c7� <br />05 m �L <br />y- <br />N M Z J F <br />ILW <br />OU o <br />mom W ❑❑ <br />N Q <br />0 <br />0 N <br />� o <br />- N <br />e„ <br />O,U <br />I,()^ may. N <br />v <br />X <br />U) <br />U 6 <br />LLI J <br />oi..., <br />I- _ E <br />IBM <br />_ <br />I li U o <br />, <br />W N <br />�C N <br />e <br />C <br />w <br />Cl> <br />M <br />g ¢ <br />'ZZ <br />I.I.. <br />4. E <br />Z O <br />o° <br />Y N <br />z <br />E: U <br />wz <br />od <br />no <br />00 <br />o E <br />o <br />o <br />�< <br />L <br />2O <br />q <br /><o <br />W z <br />�J <br /><z <br />0U <br />mo <br />O S_ <br />m J <br />2 <br />�z <br />8 <br />�� <br />aw <br />°� <br />'. <br />go <br />�z <br />co <br />az <br />C� <br />CD <br />a? <br />-4- <br />z�a <br />° A <br />> � <br />LO <br />ui <br />C <br />1 <br />C <br />F�- <br />Ln <br />M <br />O <br />Y <br />T <br />� Y v <br />N <br />m <br />LO <br />U)4-1 <br />O (n N <br />�-+ <br />O <br />I <br />CD <br />T <br />.0 LL <br />N <br />LO co <br />LO <br />< <br />z- <br />co dQ <br />E <br />"cL0Z <br />Z <br />E <br />E O <br />cv <br />E <br />U 0 <br />a <br />JOB <br />NO: 23-04657 <br />SCALE : AS NOTED <br />SHEET NO. <br />W P <br />I i I ,1 11.. _,.; .i 1.:. d.; . .II tlIS TL, 4 �Jtrill I I I I I ill I I I ! <br />