My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36351-36371 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36351-36371 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:39:27 AM
Creation date
2/19/2025 11:31:50 AM
Metadata
Fields
Template:
Building Plans
Street #
36351-36371
Location
Garden Wall Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OWNER'S BATHROOM <br />SCALE: 3/8" =1'-0" <br />9 <br />00 <br />Cl) <br />m <br />MIRROR <br />i�--1 <br />- <br />1 <br />_ <br />tit <br />b <br />BATHROOM 2 <br />SCALE: 3/8" = 1'-0" <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18JX25J <br />S.H. <br />13 <br />20X38J <br />18JX374 <br />S.H. <br />14 <br />20X50J <br />184X50 <br />S.H. <br />15 <br />20X63 <br />18JX62} <br />S.H. <br />16 <br />20X72 <br />18�X711 <br />S,H. <br />1 H2 <br />27 114 X 26 <br />26 X 25 J <br />S.H. <br />1 H3 <br />27 1/4 X 38 <br />26 x 3711 <br />S.H. <br />i H4 <br />27 J X 501 <br />26 x 50 <br />S.H. <br />1115 <br />27JX63 <br />26X621/2 <br />S.H. <br />1H6 <br />27aX72 <br />26X711/2 <br />S.H. <br />22 <br />37 JX 26 <br />36 J X 251 /2 <br />S.H. <br />23 <br />37 J X 38 J <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 i <br />36 J X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 J X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 J X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 J WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 } X 25 4 <br />S.H. <br />33 <br />54 X 38 2 <br />52 4 X 37 J <br />S.H. <br />34 <br />54 X 50 8 <br />52 7' X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 z4 X 62 4 <br />S.H. <br />36 <br />54 X 72 <br />52 } X 714 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />STAIR DATA: <br />18 RISERS @ 7.153" <br />17 TREADS @ 10" DRYWALL <br />TOTAL RISE = 10'-8 3/4" <br />TOTAL RUN = 14'-2" 42" KNEE WALL <br />WITH 1x8 CAP & <br />3/4" PLYWOOD �� CASING (AT 2nd 1 1/2" MIN. CLEARANCE <br />DECKING �� FLOOR ONLY) <br />(2) 2X8 w/ 1/2" <br />FLITCH HEADER <br />co <br />SLOPE CEILING TO <br />MATCH STAIR RISE <br />F. FL: F. FL. <br />------- --------- �� -- <br />17 �� 1 114" TO 2" DIA <br />16 HANDRAIL NO <br />15 LESS THAN 34" <br />14 �� NOR MORE <br />13 U THAN 38" ABV. <br />12 Z TREAD NOSING <br />11 CONT. <br />1 HAND RAIL METAL <br />HANDRAIL <br />BRACKET <br />BLOCKING AS <br />REQUIRED <br />n. <br />F. FL. <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 91/4" <br />LVL 2.OE Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) -1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />Stair and Railing General: Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9116 inch or a bevel not exceeding % inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newef posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair sUrfacb and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />It 18'-4" <br />1'4" 134" b 3 -i <br />AC PAD I I oC PAD N OF <br />A OUTDOOR LIVING <br />o S3 9'-4" CLG. A.F.F. <br />9 CONCRETE <br />8" 6'-0" 10'-8" <br />" 6'-8" 10 3'-10" L& 3'-10" L. 2'-8rr- <br />o r <br />6068 SG ID <br />A� i ll i <br />o Co _ 5-SH <br />t r T <br />N 2468 - REF <br />I <br />7'-11" 3'-2" 6-7" <br />o <br />O <br />2 <br />Cn <br />ro © M w Igo <br />DINING o KITCHEN Q <br />9'-4" FLAT CLG. 9'4" FLAT CLG. <br />TILE TILE <br />ao __ <br />SINK w/ <br />D/W DISPOSAL <br />;__ <br />L_____ _J_goo <br />_._ FLRG. LINE <br />2x8 WALL <br />8'-0" 6-0" 3'-8" <br />16" CNTR. AT 42" ,ten <br />o U) r A.F.F. 1/2 WALL <br />;0 M O 04 r` CAPPED <br />r 1 <br />II UP 2 <br />3 <br />co 00 `0 55 - 4 <br />GREAT ROOM 5 <br />" ' 9-4FLAT CLG 6 <br />- CARPET <br />7 <br />13-8" <br />o ot <br />GG _ <br />T S3 10 <br />11 <br />o O LO 12 <br />2x6 WALL <br />M <br />6-8" 2'-8" 4'-4" <br />*NO UPLIFT* <br />Q - - <br />S4 - - -- <br />-- � w - <br />FLRG. LINE H 1 N <br />N <br />is <br />o I �- -TILE - - <br />N 10007 <br />105 N u_ <br />,5 F w <br />N I� <br />FOYER <br />9'-4" FLAT CLG. 2868 <br />oo TILE <br />(] 0P <br />00 <br />- 1= T.O.M <br />- 9' 4 O <br />- 7'_0" <br />Z-6" <br />3068 BUILDER TO <br />PROVIDE <br />APPLIANCE <br />2'-0' 4'- -0" PROTECTION <br />1 1WHEN <br />C 2'- " 4'-8"10 REQUIRED PER <br />E Y FBG <br />`D 9'-4' PLG. A.F.F. <br />CONCRETE1-CAR GARAG E <br />-------- 9'-4" FIJTCLG. <br />CONCRETE <br />- � o <br />Lc 04 <br />N <br />16" SQUARE - <br />q CMU COLUMN _ -- <br />o - <br />r LO r--------------•- --- <br />t <br />� I I <br />0o d I I <br />�1 ■ I LINE OF 2nd STRY. ABV. I <br />I **NOTE <br />01 p I BILK. WALLS A RE 8'-8" i <br />I TALL FOR "A" I.JNIT 5'-8' <br />FROM FRONT OF <br />00 9 <br />GARAGE 1 <br />K TYP. @ I <br />I S4 GARAGEI <br />8'x7' GARAGE OOR <br />1 ST FLOOR <br />SCALE: Y4'=1'-0" <br />UNIT -A 1532 <br />D1 <br />r <br />ZI <br />1. <br />91 <br />�IF0 <br />I <br />01 <br />I <br />FILLED CELL LEGEND <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />® FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />,Q- <br />34, <br />12'-0" 3'-0" <br />1'4" o V-8" L. 3'-10" <br />5'-0" 3'-10" <br />2'-8" <br />op <br />© <br />oAo <br />MOD <br />25 SH <br />MOD 25 SH <br />( 39" <br />x 591, <br />( 39" x 59" ) <br />EGRESS I EGRESS <br />0 <br />00 <br />OWNER'S <br />Zo <br />55 <br />BEDROOM <br />D1 -- <br />TYP. U N O. -- M�� <br />8'-0" FLAT CLG. <br />I CARPET <br />CV <br />o <br />I <br />00 <br />0 <br />N <br />00 <br />17'-8" <br />CO <br />- <br />6'-4" <br />_ <br />4'4" 7-0" <br />I <br />- M.C. <br />R&S <br />_.. <br />----------, <br />_ O. BAT <br />H I 22"x36" <br />8'-0" FLA <br />CARP <br />CLG. ATTIC <br />T ACCESS <br />�p� <br />I 1 C I <br />N <br />-- <br />C <br />/ V V <br />1 1). FLAT �W <br />� <br />M <br />-1 <br />N I <br />to <br />'ItN / CARPET I <br />iv <br />PW01 <br />_ _ _----- <br />(-A Cf) <br />I <br />R&S <br />I ► + <br />N <br />Cl)o <br />2868 <br />5 <br />= <br />T <br />6 <br />oo <br />_ <br />_ <br />I d <br />7 <br />00 <br />- E TO <br />00 <br />7' A. _ . <br />C 8 <br />N <br />AHU 9 <br />60"x <br />r <br />°P <br />_ <br />OWER PAN <br />I <br />10 <br />v <br />� <br />co <br />--- <br />0 <br />R!A l I 11 <br />� <br />1 5' 114 <br />4- 4„ <br />3'-4" I I 3'-8� <br />OP <br />LOFT 13 <br />1 <br />rD <br />8'-0" FLAT CLG. 14LO <br />0 <br />_ <br />- j <br />00 r' <br />00 <br />N <br />CARPET 1 15 <br />I 16 <br />I <br />00 <br />in <br />-- <br />1 1 17 <br />00 <br />in <br />91� <br />I I UP 18 <br />T A. F. F. <br />LJ <br />-- 0 <br />D <br />1/2 WALL <br />I b� <br />CAPPED <br />5' 4 <br />CV <br />1'-10" <br />9 _6" <br />0 <br />00= <br />BAT <br />2668 <br />O <br />8'-0" FLAT <br />CLG I <br />CARP <br />_ M.G. <br />T <br />0, <br />I WIC <br />( 8'-0" FLAT CLG. <br />(y <br />CARPET <br />2668 <br />CV <br />u)co <br />&DD <br />_- i rn <br />CO <br />- I <br />Z <br />BEDROOM 2 <br />- R&S <br />8'-0" FLAT CLG. <br />I I <br />I <br />CARPET <br />Miv <br />_ <br />G.T. <br />- <br />G.T. <br />imp <br />-- <br />( 1-S l <br />in <br />MODD 2255 SH <br />( 39" x 59" ) <br />EGRESS <br />I <br />, <br />3'-8 <br />3-10 <br />3-10" <br />10 <br />4,_0„ <br />7 -4 <br />o <br />- <br />7-0" <br />11'-4" <br />LO <br />18'-4° <br />L -- - <br />o <br />2ND FLOOR PLAN -UNIT-A 1532 <br />SCALE: Y4"=1'-0" <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />�D <br />+28.3 / -37.0 <br />+26.6 / -29.1 <br />Q <br />+26.6 / -33.5 <br />Go <br />SEE SN SHEET 6, SEE SN SHEET <br />1 An MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in. <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 677 S.F. <br />2ND FLOOR 864 S.F. <br />TOTAL 1541 S.F. <br />GARAGE 246 S.F. <br />LANAI 110 S.F. <br />ENTRY 42 S.F. <br />TOTAL SQ. FT. 1939 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/13-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />G.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />t� <br />2 <br />C � <br />m c._a,� <br />w <br />a <br />J; : a, <br />.cam°, <br />H <br />E <br />a <br />a f. <br />.O <br />• /. <br />Ile <br />LL <br />J F E 5l®� y\N <br />�r�''r+ttlttttt��, <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />t) <br />d Ep <br />Q 8 <br />N O <br />N <br />.� <br />11 0 m� n <br />at ��rD <br />NO <br />J <br />W <br />,\ LL Ul 0. <br />V J <br />cum <br />- he <br />Z W m a 0 <br />o O <br />7 N N <br />W o M -;; <br />m <br />Z N Z <br />N O U cQ� <br />W 13 <br />CD � r <br />o <br />N M <br />o <o <br />0__�0 <br />C1 <br />LL <br />Orov <br />C: J <br />w <br />J <br />OLrs <br />Ul rti <br />3 <br />r,-y to <br />W C <br />oi.,..,. <br />�- E <br />z <br />4, <br />Q` <br />®401 <br />�w <br />CO <br />2 <br />O <br />Z <br />QC <br />E <br />g O <br />< N <br />U <br />aIQ <br />O° <br />o< <br />N <br />°z <br />wo <br /><i <br />a <br />XY <br />. > <br />U) c <br />oY <br />0 <br />�o <br />zE <br />m <br />6 <br />�w <br />ZZ <br />W <br />En <br />w <br />o <br />z <br />gz <br />Sam a <br />o& <br />�w <br />o <br />as <br />�a <br />=3 <br />�o <br />it <br />Z. <br />a0 <br />s <br />CC) <br />L <br />01 <br />> <br />T <br />i <br />~ <br />4i <br />01 <br />CU <br />N <br />O <br />M <br />CV) <br />N <br />U> <br />N <br />T <br />�- <br />00 <br />U) m <br />N <br />4-0 <br />N <br />I- <br />0 <br />LA-) <br />iC <br />04 <br />O <br />Cn <br />Q <br />CO <br />M <br />E <br />t <br />It O <br />o <br />Z <br />m <br />z <br />0 rri <br />E N ,- <br />c <br />U 0 Q p <br />c <br />JOB <br />NO: 22-08387-08382 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />0 <br />9 U <br />8 Q bi <br />7 w <br />6 z <br />5 -g <br />2x STRINGERS 4 0? <br />3 <br />2 ,N <br />LJ F.FL. HANDRAIL DETAIL <br />14 2" L 2x4 #2 SYP. P.T. THRUST SCALE: 3" =1'-0" <br />Im BLOCK W/(2)-1/4"x 31/2" <br />TAPCONS @ 16"o.c. AND <br />TYP. STAIR SECTION 3" FROM EA. END. <br />SCALE: 1/4" = 1'4' <br />
The URL can be used to link to this page
Your browser does not support the video tag.