My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36375-36395 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36375-36395 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:09:31 AM
Creation date
2/19/2025 11:32:38 AM
Metadata
Fields
Template:
Building Plans
Street #
36375-36395
Location
Garden Wall Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
5118-5123
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14, <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />,�. <br />EXHAUST FAN/LIGHT COMBINATION <br />I� <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TV <br />TELEVISION (OPTIONAL) <br />02 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�M <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C�!ri <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />T <br />CEILING MOUNTED LIGHT FIXTURE W! ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />I <br />i I <br />I I <br />I I <br />LAV T--- I <br />� I <br />t� TUB/ <br />W/C SHOWER <br />LAV <br />3" VTR <br />AIL <br />I <br />I <br />I <br />t <br />I <br />I OPT. <br />I LAV <br />LAV <br />I <br />I <br />cU L W/C <br />SHOWER <br />„ ` --__2f7a <br />STU DO R -� <br />VENTT LrJ DBL SINK <br />W/ DISP. <br />W/C <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />UNIT -A 1532 (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />45991 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />NEMA1 <br />2lx) AMP <br />� rrrn nnn e, <br />1�0-200 AMP I IT/ —Serial Cable <br />3R <br />Power Co. Feed _--_ I J I #4 Solid COPPER Ground <br />W93 <br />I� <br />Intersystem Bonding <br />Termination Per <br />NEC 17, 250.94 5/8" Galvanized Driven Ground <br />Rods at least V apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />DB&GFITO <br />BE ALIGNED <br />VERTICALLY <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL — UNIT —A 1532 <br />SCALE: Y4"=1'-0" <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED, LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />F — — — — — <br />OWNER'S <br />BEDROOM <br />/,,>ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT <br />I <br />S.D <br />----- ----D-1 —1 <br />O. BATH \ 1 <br />--WIC I <br />----- ----- <br />�GFI <br />/ 1 /' c m <br />I <br />II II ` <br />I <br />LOFT `� t <br />G <br />� <br />BATH 2 <br />i <br />S.D. <br />iGFI <br />WIC € <br />I <br />I <br />I <br />/,>ROUGH-IN <br />t� �>FOPT. <br />FAN/LIGHT <br />/LIGHT <br />\BEDROOM 2 <br />L — <br />2ND ELECTRICAL — UNIT -A 1532 <br />SCALE: Y4'=1'-0" <br />c <br />N <br />o <br />c <br />o <br />�m <br />�o <br />N d <br />�i`cr� � <br />� `• as u d <br />tlf, <br />0 <br />CV <br />CV <br />CV <br />0 <br />0 <br />To the best of the Engineer's knowiedge, Information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0 <br />W <br />4 <br />�E <br />p M U <br />N O <br />co <br />a <br />N <br />Q <br />coNN C) CAL <br />C J LL <br />J u-d <br />Z <br />°' a <br />rmo 3 <br />Z <br />M N � <br />O <br />W <br />S <br />�2CPO m w <br />Z <br />uIL <br />CC,N Z Q J <br />Z <br />N 00 < v <br />W <br />Cq M <br />z N c"Y <br />z <br />N <br />z o � <br />T <br />V! <br />N <br />M <br />z <br />0 <br />(� <br />u, ca <br />° <br />U <br />T � <br />0«ro <br />y <br />wd <br />�N <br />in <br />v <br />w <br />•, <br />Rig <br />v;' <br />_ � m <br />C) o' N <br />° <br />U <br />�Q <br />¢ N 0 <br />e� <br />o <br />w <br />M <br />z� <br />o <br />z <br />� <br />«i E <br />zo <br />QO <br />>� <br />QN <br />Q <br />Ci 8 <br />�® <br />X O <br />0 <br />�� <br />Z <br />O E <br />N <br />E .o <br />°z <br />4o <br />¢ o <br />a z <br />ire <br />L <br />M <br />Cn C <br />< <br />m 0 <br />o <br />°zZ <br />N <br />J <br />.0 <br />wm <br />¢w <br />�z <br />u� <br />¢" <br />< <br />5 0 <br />aL�'i <br />Q <br />S <br />a< <br />a w <br />� <br />W <br />xi= <br />JW <br />`< <br />�~ <br />o <br />Y° <br />a <br />OU <br />Vim' <br />zla <br />3 <br />c O <br />0 <br />co <br />ai <br />rn <br />Nc� <br />c^� <br />CO M <br />N <br />N <br />r <br />o0 <br />60 <br />U) m <br />N <br />O <br />LO <br />C <br />M <br />CN <br />C3� <br />,6 <br />T <br />CV <br />r <br />MM <br />W <br />� <br />a <br />Z <br />cca <br />z <br />E r <br />iri <br />a <br />W <br />E <br />°' <br />a) <br />a <br />a <br />U <br />JOB <br />NO: 22-06565-06560 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />
The URL can be used to link to this page
Your browser does not support the video tag.