My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36651 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36651 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:30:13 AM
Creation date
2/19/2025 11:33:08 AM
Metadata
Fields
Template:
Building Plans
Street #
36651
Location
Garden Wall Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
5067
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A/C <br />DISCONNECT <br />WP <br />GFI <br />ELEC <br />METER <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION A <br />1 /4" = 1'-0" <br />SECOND FLOOR ELECTRICAL PLAN (ELEVATION A' <br />1 /4" = 1 1-0" <br />I ELECTRICAL NOTES: I <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL RE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />V <br />VIRTUAL REV't'% A55. <br />Virtual Rev. <br />.le�, i` �'_' „� . <br />._.,d <br />Plans Review cc� ..� <br />for CompiianCe with n� Klanr PX2�Jo <br />Edition by Debra An <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />i� <br />SWITCH- <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o Z <br />k �' <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />MOUNTED <br />HORIZONTAL <br />AT 12" - TOP PLUG IS HOT <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />�- SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />-wi*- 4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />— DIMMER SWITCH AT 36" <br />-0 PUSH-BUTTON DOORBELL <br />+ CLG MNT LT FIXTURE <br />EB} CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />WALL MNT FIXTURE <br />NOTE: <br />ND OPALEX - ALTERNATE <br />TUB/SHOWERCANS MAY BE <br />0 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />0 50W MR16 4" LOW VOLTAGE OWNER <br />Q 50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />cs SMOKE COMBINATION <br />ARBON MONOIXED DETECTOR/ <br />�s SMOKE DETECTOR <br />-U-18= UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />-U-24- UNDER CABINET 24" <br />-S-24- SINGLE 24" FLUOR STRIP <br />-D-24- DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 — DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />G& 24 -ii2 24" VANITY LIGHTING <br />9;-u& 36 :;v-� 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />® EXHAUST FAN <br />Utp DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />® CHIMES (DELETE W/ INTERCOM) <br />1� MASTER STATION <br />S&Z-1 ELEC PANEL <br />M VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />® A/C REGISTER <br />(T THERMOSTAT <br />® SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />f <br />W <br />L 100 " U <br />M N <br />to <br />V �0° M <br />V/ OQ 2 O <br />VJ <br />_ <br />g N Q <br />• <br />N <br />^, <br />w C'; � Z <br />Q C14 c <br />Eri rn <br />7W <br />V <br />L p <br />- a a <br />W <br />ow uj0 <br />wol <2 � YZ� z <br />Ix 0W <br />Q U <br />Q <br />Q� -1 (1) 0 3: w M LL 000O <br />DOX�z�u-9zM0 <br />0 <br />F- <br />O 0 <br />C1 O Z <br />Ocn� OzO0fOomz <br />Nwn.�v5WwU,Vif1f <br />�¢adOw'd��zwz�wc�Da <br />-gwoP <br />U <br />� <br />LL <br />¢~Ow �i- <br />OQ o =O oazq�¢ <br />Q <br />LL <br />r-Qu <br />O <br />O <br />N <br />W <br />O <br />%D O <br />0 �M O <br />d <br />J <br />((AI <br />LL <br />W Ln <br />oC CL 4 <br />Z <br />00 <br />Z <br />W <br />Jo <br />ILD <br />d' <br />N <br />O <br />N <br />i <br />O <br />N <br />O <br />i. <br />a <br />O <br />00 <br />W <br />00 <br />W <br />O <br />O <br />D <br />NO <br />O <br />O <br />N <br />O <br />N <br />O <br />CV <br />O <br />N <br />ON <br />N <br />N <br />N <br />O <br />N <br />O <br />O— <br />O <br />O <br />op <br />O <br />N <br />M <br />O <br />N <br />4 <br />0 <br />�&( <br />00 <br />C) <br />O <br />O <br />N <br />0 <br />0 <br />0 <br />;n <br />> <br />0 <br />N <br />0 <br />M <br />0 <br />d <br />0 <br />0 <br />C <br />0 <br />ti <br />M <br />V`J <br />w <br />Z Z <br />O <br />w <br />�0�o <br />c� <br />W <br />o <br />0 <br />M <br />-0 <br />F— <br />�- <br />owwQ <br />a <br />LO-0 <br />Z <br />ZWF� <br />=MOZ <br />(� <br />Z Z�w <br />LL <br />r•I <br />Z z <br />N <br />w � <br />00 <br />O <br />U <br />a- w <br />co z <br />r <br />Z T-1 <br />T<O <br />• <br />32 <br />Z <br />U <br />U <br />a <br />0 <br />O <br />W <br />� <br />z <br />Q <br />Z <br />w <br />w <br />J <br />W <br />0 <br />N <br />LAST PLOT DATE <br />Apr. 27, 22 <br />1 ST & 2ND FLOOR <br />Z 0 <br />J <br />ELECTRICAL PLAN A <br />
The URL can be used to link to this page
Your browser does not support the video tag.