ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Are -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315,1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />(. <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />P4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />;O <br />P. <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�{]BD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />e USB <br />TELEPHONE/USB (OPTIONAL) <br />TV <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD: HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />L J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />G9 <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR I <br />3" VTR j �- I <br />JIL i <br />I I <br />I I <br />�I OPT. <br />' I I LAV �V <br />HANSON <br />I I BOX <br />I I 3 <br />W/C <br />LAV T\ <br />3" SHOWER <br />TUB/ — <br />W/C SHOWER \` <br />2nd <br />3 ,F.F�R <br />STUVENDOR DBL SINK C O <br />W/ DISP. <br />2" <br />LAV 3" <br />rJ , .. W/CQ�3 <br />LOAD CALCULATIONS <br />`O DISCONNECT <br />F— — — <br />OUTDOOR LIVING <br />INSTALL LIGHT �� <br />ROUGH -IN / C <br />FOR OPT. <br />FAN/LIGHT WP 3 <br />( GFI i <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />— —� <br />Unit -A- (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />WATTS <br />1 <br />12000 <br />OTHER LOADAT1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 10 KW at 100% <br />10000 <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />Optional Overhead Service <br />Same As Underground <br />150 Or 200 Amp Service <br />I <br />Power Co. Feed <br />200A <br />Indoor Panel <br />Center <br />NEMA1 <br />RMAN <br />200 AMP <br />3R <br />I Cable <br />#4 Solid COPPER Ground <br />II <br />Intersystem Bonding <br />Termination Per <br />NEC 08, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />IOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />'HE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS I AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />DB & GFI TO <br />BE ALIGNED <br />VERTICALLY <br />GFI <br />DEDICATED <br />jGFI RECEPTACLE FOR <br />MICROWAVE <br />DINING \ \ � RANGE HOOD PER <br />SPECS <br />Ip <br />KITCHEN l <br />GqI <br />FI 0 r-CaF1_J <br />---- ---- GFI <br />-- --- <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK C.M <br />f <br />II <br />\ I <br />GREAT ROOM <br />>ROUGH -IN\ <br />FOR OPT. CH <br />FAN/LIGHT <br />1 <br />y� � <br />I TO SATCH <br />UPSTAIRS <br />I <br />FOYER <br />G <br />GFI <br />- \ <br />@ 44" <br />W.H. <br />A.F.F. <br />1 \ O <br />I <br />� I <br />ENtRI <br />I GARAG E <br />WPDB <br />LIGH��AS FIPEER <br />1 <br />\� <br />/ <br />GARAGE <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />DOOR <br />' <br />GFI <br />' <br />1 <br />I <br />W <br />I <br />Q <br />Ip ZLU <br />IU a <br />I <br />I <br />W <br />W Z <br />I0 <br />I <br />�00� <br />��wo <br />ICU <br />I <br />I <br />Q Ud <br />lu- <br />rrW <br />I <br />> -j m <br />I <br />tCOACH <br />LIGHTS <br />EWIRE AS <br />PER <br />SPECS <br />1ST ELECTRICAL - UNIT -A 1532 <br />SCALE:)/ '=T-0" <br />2ND ELECTRICAL -UNIT-A 1532 <br />SCALE: y"=V-0" <br />N <br />N -C O <br />c <br />0f�0' <br />e <br />aU <br />CLmx <br />- <br />M LL <br />V M `O N <br />C � N <br />c <br />CL C <br />Q;0 M <br />r <br />a.0;� C0 <br />a U) 0 0 <br />0 C L) <br />�W <br />N <br />C'V <br />c>' <br />N <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers <br />signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />v <br />n <br />W <br />Q <br />v E <br />O om 8CON <br />CN <br />N Cb 0 <br />N a00 ctO.i a- m <br />N <br />r'n to <br />".�� <br />"t ¢ `J` <br />a <br />m <br />J LL O W <br />� o <br />JLLLU <br />o <br />Z <br />IT 0 <br />r @� <br />w (If o <br />W <br />03 <br />05 <br />Z <br />IL <br />cp m w <br />OD d <br />N M Z Q O J <br />Z <br />N Q 0_ to O <br />O U L) W <br />W <br />❑❑❑ <br />v M <br />Z N n <br />o <br />z <br />z o � <br />d l(J <br />N <br />z:9 <br />`o <br />�N <br />(9 <br />LU <br />O <br />v) <br />v) <br />W o <br />°I�rl <br />U <br />.. <br />all'— <br />J <br />L U <br />I <br />_ Go W <br />CIO <br />Q O <br />N -m <br />14 <br />I� <br />� <br />¢ <br />w <br />z <br />co <br />- <br />LL <br />(L E <br />wo <br />-O <br />>� <br />QN <br />CL O <br />E U <br />Z <br />Fm— <br />O <br />z0 <br />1<¢Ww <br />a z <br />DO <br />O <br />w w <br />N I— <br />oo <br />w 2 <br />ate.. L' <br />C <br />� <br />�Z <br />O Y <br />�Z� <br />m2 <br />O LL <br />Z <br />N <br />J <br />m <br />¢w <br />�z <br />to <br />a� <br />�" <br />o2 <br />5� <br />a <br />ww <br />az <br />nw <br />W <br />yLL <br />�3 <br />O <br />< <br />w <br />_0 <br />�o <br />O <br />I <br />>a F <br />o T <br />.L <br />> d. <br />o� <br />CNJ <br />00 <br />� <br />r <br />O <br />LS7 <br />U <br />5 <br />�o <br />00 <br />CM <br />r <br />CM <br />N <br />F— <br />O <br />CD <br />00 <br />d- <br />J o <br />r <br />LO <br />E <br />E C <br />Z <br />m <br />Z <br />E C) <br />vi <br />ca <br />a <br />E <br />U � <br />Q p <br />JOB <br />NO: 22-03915-03908 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />13 <br />