My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
37643-37671 Leafside Ln
Zephyrhills
>
Building Department
>
Building Plans
>
37643-37671 Leafside Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 10:43:38 AM
Creation date
2/19/2025 11:33:33 AM
Metadata
Fields
Template:
Building Plans
Street #
37643-37671
Location
Leafside Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
4157-4162
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-0 <br />N t o <br />O O O O O °°• v .a v •.. •ea v <br />8F8-1B/1T 8F8-0B/1T <br />O O O O O D O O <br />8RF14-1B/1T8RF14-013/1T 8F16-1B/1T 8F16-0B/1T <br />© O O O <br />a <br />O O <br />8RF6-0B/1 T <br />5", <br />° <br />U6,1' :O,° <br />° <br />O O <br />8F20-1B/1T 81F20-013/1T 8F20-113-2T <br />O O 0 81724-1 B/11 T 8F24-OB/1T <br />F <br />0 <br />O <br />TYPE DESIGNATION <br />F = FILLED WITH <br />GROUT / U = UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />J <br />w <br />8F1� B/1T <br />a z <br />ib g <br />u� O <br />N Z <br />tNOMINAL. <br />QUANTITYOF <br />WIDTH <br />#5 REBAR AT <br />TOP <br />NOMINAL <br />HEIGHT <br />iic precast lintels = 3500 psi. <br />Pc prestressed lintels = 6000 psi. <br />§routed per ASTM C476 f'g = 3000 psi w/ <br />Maximum 3/8" aggregate and 8" to 11" slump. <br />concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />Rebar per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />270 low relaxation. <br />7/32 wire per ASTM A510. <br />81ortar per ASTM C270 type M or S. <br />ALTERNATE POWERS <br />STEEL LINTEL <br />#5 REBAR <br />AT TOP <br />#5 REBAR AT TOP <br />MIN. <br />(1) REQ'D <br />1/2" <br />MIN. (1) REQ'D- <br />1-1/2" CLEAR <br />d n <br />CLEAR <br />= <br />O <br />d C <br />✓ <br />a <br />.M.U. <br />w <br />C% <br />as a <br />Lu <br />u <br />C <br />C.M.U. <br />e <br />20 U � <br />� .0 <br />a e <br />GROUT <br />� LLJ J <br />� <br />wSQa? <br />5 REBAR AT <br />J N <br />WBOTTOM <br />a <br />OF <br />Z w u) <br />r <br />5 REBAR AT BOTTOM <br />LINTEL CAVITY <br />¢ ¢ <br />REQ'D <br />o <br />BOTTOM REINFORCING <br />xC,/ <br />O o <br />MIN. (1) <br />PROVIDED IN LINTEL <br />, (VARIES) <br />U) LL w <br />�� <br />7-5/8"ACTUAL <br />—16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting. <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required top and <br />bottom of all Powers Steel lintels. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 174" and <br />longer with a nominal height of 8" meet or exceed L/180. <br />6, Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7, 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10, Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load / . O <br />Safe vertical load Safe horizontal load \— <br />SYMETRICAL <br />I <br />rD nD rD (D) n nD n CD) <br />2ND FLOOR LINTEL PLAN_ <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />(F) (F OFO iF0 <br />O E I I <br />O O O <br />MIN. MIN. MIN. MIN. <br />1ST FLOOR LINTEL PLAN <br />SYMETRICAL <br />O M <br />c14 <br />Q m X <br />cl-i N a <br />*-r <br />Mom <br />CD 4) <br />,► + N <br />a-C Q <br />M <br />p <br />N <br />(� CL Q <br />.�i E <br />M; to, 0 O <br />U <br />�O �G <br />o� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />v <br />N <br />W N <br />v E <br />11- 0 <br />J <br />6 cot)w <br />0 <br />U N <br />0 N <br /># <br />M rn CNN <br />CD 2 Q IJi <br />ccoo d' <br />Y/ <br />N S J 0. <br />� ro � LL 52 h o w <br />J w � o- <br />Z cO7 0 0 <br />m Co <br />t @ o 3: <br />7 Co N 0 O OY <br />W �oo m w w <br />Z LLLO coZ ¢ O <br />N <br />QIL n O <br />(� <br />� " <br />Z 0 Co <br />❑❑ <br />W ❑Arm <br />Rai <br />Z N M <br />O O <br />Z ip <br />QO <br />QN <br />z O Q <br />Q � <br />— <br />N <br />M <br />Ln 'zn ca <br />^ , C <br />V O <br />LL <br />T fn <br />� <br />m <br />U <br />O W O <br />V) w <br />N � <br />60�0 <br />U <br />W <br />E <br />asp <br />=3. <br />Of U) I <br />Q <br />O <br />J <br />W <br />Mm <br />o <br />z <br />� <br />LJ- <br />E <br />z o <br />- <br />> <br />a R <br />ca <br />E 8F- <br />z® <br />oa <br />co <br />XOU <br />Up <br />r <br />70 <br />0 <br />Z <br />C <br />O C <br />N <br />L <br />a <br />az <br />o <br />QO <br />a z <br />CID <br />¢~Z <br />o <br />y <br />mi <br />z F <br />Z <br />J <br />m <br />¢ <br />Q W <br />z <br />to <br />0¢ <br />z <br />go <br />W <br />� <br />a <br />y W <br />o <br />CDco <br />wl <br />a z <br />za <br />°3 <br />C <br />0 r <br />> d' <br />m <br />C114L <br />0 <br />r <br />6i' <br />O <br />C5 <br />�o <br />5 <br />M <br />50 <br />r <br />4. <br />M N <br />Q0 <br />�—' <br />O N <br />00 <br />T <br />O <br />E <br />o <br />O <br />Z <br />co <br />Z <br />E O N <br />CU <br />co <br />FL <br />E <br />U - Q 0 <br />-J <br />JOB <br />NO: 22-03915-03908 <br />SCALE : AS NOTED <br />SHEET NO. <br />L 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.