MECHANICAL LEGEND <br />EXISTING SUPPLY <br />EXISTING RETURN <br />EXISTING EXHAUST <br />® <br />SUPPLY <br />RETURN OR TRANSFER <br />® <br />EXHAUST <br />eEQUIPMENT <br />MARK <br />-' <br />MANUAL BALANCING DAMPER <br />/ <br />✓ EXISTING FLEX -DUCT <br />FLEX -DUCT <br />k EXISTING DOUBLE DUCT TO BE REMOVED <br />OT <br />NEW THERMOSTAT <br />ODRAWING <br />NOTE <br />-U_> <br />1" DOOR UNDERCUT <br />TAP WITH DAMPER <br />DUCT UP <br />DUCT DOWN <br />SINGLE LINE DUCT <br />Ci <br />PIPE DOWN <br />Q+- <br />PIPE UP <br />[ <br />END CAP <br />< <br />INDICATES SUPPLY AIRFLOW <br />INDICATES RETURN AIRFLOW <br />MECHANICAL ABBREVIATIONS <br />(E) <br />EXISTING <br />AFF <br />ABOVE FINISHED FLOOR <br />CD <br />CEILING DIFFUSER <br />CFM <br />CUBIC FEET PER MINUTE <br />CG <br />CEILING GRILLE <br />CO <br />PIPE CLEAN -OUT <br />CTE <br />CONNECT TO EXISTING <br />EA <br />EXHAUST AIR <br />EF <br />EXHAUST FAN <br />FBC <br />FLORIDA BUILDING CODE <br />FPM <br />FEET PER MINUTE <br />(N) <br />NEW <br />NC <br />NEW CONNECTION <br />QA <br />OUTSIDE AIR <br />OBD <br />OPPOSED BLADE DAMPER <br />RA <br />RETURN AIR <br />RTU <br />ROOFTOP UNIT <br />SA <br />SUPPLY AIR <br />VD <br />VOLUME DAMPER <br />DEMOLITION KEYNOTES <br />1. REMOVE AND PROPERLY DISPOSE OF EXISTING PLUMBING FIXTURES <br />WITHIN HATCHED REGION. REMOVE ASSOCIATED PLUMBING PIPING <br />BACK TO WALL OR BELOW SLAB AND CAP. <br />2. REMOVE AND PROPERLY DISPOSE OF EXISTING EXHAUST FAN AND <br />ASSOCIATED EQUIPMENT, DUCTWORK, WIRING AND DEVICES. REPAIR <br />ANY HOLES IN EXTERIOR WALLS OR ROOF WITH LIKE MATERIALS. <br />AREA NOT IN <br />SCOPE <br />(D RENOVATION KEYNOTES <br />1. RELOCATED EXISTING SUPPLY DIFFUSER. ENSURE FLEX DUCT RUN -OUT <br />SIZE IS EQUAL TO WHAT IS CALLED OUT ON DRAWINGS. UPSIZE FLEX <br />DUCT OR EXTEND AS NEEDED TO ACHIEVE SPECIFIED AIRFLOWS. <br />2. RELOCATED EXISTING RETURN GRILLE. <br />3. EXISTING RETURN GRILLES TO REMAIN. <br />4. PROVIDE NEW SUPPLY DIFFUSER. ROUTE FLEX DUCT TO NEAREST <br />EXISTING SUPPLY DUCT MAIN. REFER TO DETAIL FOR PROPER <br />CONNECTION. NEW DIFFUSER MODEL TO MATCH EXISTING. IF NO MODEL <br />NUMBER IS KNOWN, PROVIDE TITUS TDC-AA. <br />5. PROVIDE NEW RETURN GRILLE. ROUTE NEW DUCTWORK TO NEAREST <br />RETURN DUCT MAIN. REFER TO DETAIL FOR PROPER CONNECTION. NEW', <br />GRILLE MODEL TO MATCH EXISTING. IF NO MODEL NUMBER IS KNOWN, <br />PROVIDE TITUS 350FL. <br />O(E)C <br />95.CFM <br />AREA NOT IN <br />SCOPE <br />MECHANICAL NOTES. <br />10. <br />THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL TRADES INSTALLATION <br />INDUSTRIES MODEL #120 (FLAME SPREAD = 5, SMOKE DEVELOPED = 10) OTHER <br />SCHEDULES. FIXED WORK SUCH AS DUCTWORK AND PLUMBING SHALL BE <br />ACCEPTABLE MANUFACTURERS ARE OWENS CORNING AND KNAUF. IN LIEU OF <br />INSTALLED PRIOR TO ANY TRADE WORK THAT CAN BE EASILY RELOCATED OR <br />SHEET METAL DUCTWORK, DUCT BOARD MAY BE USED. CONTRACTOR SHALL (BID <br />1. IN GENERAL, PLANS AND DETAILS ARE DIAGRAMMATIC IN NATURE AND SHOULD <br />OFFSET SUCH AS ELECTRICAL CONDUITS, SMALL WATER LINES, ETC. IDEALLY <br />AS DEDUCTIVE ALTERNATE). 1.5" THICK DUCT BOARD (EQUAL TO JOHNS MANVILLE <br />NOT BE SCALED. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD <br />DUCTWORK SHALL BE INSTALLED FIRST. <br />BONDED WITH THERMO SETTING RESIN ON AIR STREAM SIDE WITH AN <br />VERIFY SPACE ALLOCATED PRIOR TO ORDERING EQUIPMENT. <br />ANTI -MICROBIAL COATING) AND CONFORM WITH UL STANDARDS FOR SAFETY AIR <br />11. <br />INTENT OF THESE NOTES AND MECHANICAL NOTES ON DRAWINGS IS TO CLARIFY <br />DUCT, NO. 181, 1967 ESTABLISHED FOR CLASS 1 AIR DUCTS. FACING SHALL BE <br />2. THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH SUBMITTED <br />THE SCOPE OF WORK AND ALERT CONTRACTOR OF EXISTING CONDITIONS. THE <br />FSK ALUMINUM FOIL. CONSTRUCTION SHALL COMPLY WITH RECOMMENDATIONS <br />EQUIPMENT TO ENSURE ALL INLET/OUTLET CONNECTIONS COORDINATE WITH <br />CONTRACTOR IS TO VISIT SITE AND VERIFY ALL CLEARANCES BEFORE <br />AND DETAILS IN SMACNA AND NAIMA FIBROUS GLASS DUCT CONSTRUCTION <br />FIELD INSTALLED DUCTWORK AND MAKE ANY NECESSARY DUCT MODIFICATIONS <br />FABRICATION OF DUCTWORK AND PROVIDE ADDITIONAL OFFSET AND/OR <br />STANDARDS, LATEST REVISION AND MANUFACTURER'S RECOMMENDATIONS. ALL <br />TO ENSURE PROPER OPERATION OF MECHANICAL EQUIPMENT. <br />CHANGES IN DUCT SIZES TO MEET FIELD CONDITIONS AND COORDINATE WITH <br />JOINTS SHALL BE SECURELY TAPED WITH FASSON 0810 OR APPROVED EQUAL <br />ELECTRICAL, PLUMBING AND FIRE PROTECTION SUBCONTRACTORS BEFORE ANY <br />PRESSURE SENSITIVE TAPE. METAL TO FIBERGLASS CONNECTIONS TO BE MADE <br />3. SUBMITTALS SHALL MEET SCHEDULED DESIGN CHARACTERISTICS. THIS INCLUDES <br />CONSTRUCTION WORK. <br />USING 3" WIDE GLASS FABRIC TAPE WITH FOSTER 30/35 MASTIC OR EQUAL. <br />BUT NOT LIMITED TO CFMS, EAT(DBNB), ESP, CAPACITIES, VOLTAGES/PHASES, <br />SUPPORT DUCTS WITH 1X2X1 22 GAUGE MINIMUM CHANNELS AND STRAP OR <br />MCA/MOCP, SONES, ETC... <br />12. <br />FLEXIBLE AND RIGID ROUND DUCT TAKE -OFFS FOR DIFFUSERS SHALL BE THE <br />12-GAUGE WIRE FROM BUILDING CONSTRUCTION. SUSPEND FROM JOISTS WITH <br />SAME SIZE AS DIFFUSER NECK. MAXIMUM FLEXIBLE DUCT LENGTH SHALL BE 8'-01'. <br />BEAM CLAMPS. PROVIDE HOT DIPPED STEEL FASTENERS, ANCHORS, RODS, <br />4. ALL CONSTRUCTION WORK SHALL ALSO MEET THE FOLLOWING BUILDING CODE <br />STRAPS, TRIM AND ANGLES FOR SUPPORT OF DUCTWORK. DUCT SIZES ON <br />REQUIREMENTS: <br />13., <br />UNLESS OTHERWISE NOTED, INSTALL DUCTWORK AS HIGH AS POSSIBLE, TIGHT <br />CONSTRUCTION DOCUMENTS ARE INTERNAL FREE -AREA DIMENSIONS. <br />TO BOTTOM OF STRUCTURE. COORDINATE DUCT ELEVATION WITH RAIN LEADERS, <br />• FLORIDA BUILDING CODE (FBC) 2017 <br />WATER PIPING, SANITARY DRAINS AND MAJOR ELECTRICAL CONDUITS. <br />24. <br />ALL EXHAUST DUCT WORK SHALL BE NON -INSULATED SHEET METAL UNLESS <br />* FBC ENERGY CONSERVATION 2017 <br />OTHER WISE NOTED. <br />* FBC MECHANICAL CODE 2017 <br />14. <br />CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO <br />• FBC PLUMBING CODE 2017 <br />SUSPEND/SUPPORT MECHANICAL EQUIPMENT AND MATERIALS. <br />25. <br />FLEXIBLE DUCT SHALL HAVE CONTINUOUS TEAR RESISTANT LINER ENCASED BY <br />INSULATING MATERIAL WITH AN OUTER VAPOR JACKET CONFORMING TO UL181 <br />5. ALL WALL MOUNTED THERMOSTATS AND/OR TEMPERATURE SENSORS SHALL BE <br />15. <br />IT IS THE RESPONSIBILITY OF THE MECHANICAL INSTALLER TO PATCH AND REPAIR <br />UNLESS THE FLEX DUCT MEETS THE CRITERIA STATED IN 2017 FLORIDA BUILDING <br />INSTALLED AT AN ELEVATION OF 48" ABOVE FINISHED FLOOR TO THE TOP UNLESS <br />ANY DUCT OPENINGS WHICH RESULT FROM THE RELOCATION OR <br />CODE -BUILDING SECTION 449.3.6.4. <br />OTHERWISE NOTED ON DRAWINGS. LOCATION OF THE WALL MOUNTED <br />THERMOSTAT SHALL BE COORDINATED WITH OTHER TRADES FOR A NEAT <br />16. <br />ELIMINATION OF ANY EXISTING AIR DEVICES. THE PATCH IS TO BE OF A SIMILAR <br />26. <br />COORDINATE AIR DEVICE LOCATIONS WITH LIGHTING FIXTURES AND FIRE <br />APPEARANCE. FINAL LOCATION OF THERMOSTAT SHALL BE SUBJECT TO THE <br />MATERIAL TO THE REPAIRED DUCT AND TO BE SEALED IN ACCORDANCE WITH <br />SPRINKLER HEADS. <br />APPROVAL OF THE ENGINEER OR REPRESENTATIVE IN THE FIELD. <br />SMACNA STANDARDS. <br />27. <br />CONTRACTOR SHALL SUPPLY PIPE SUPPORTS 4'-0" ON CENTERS FOR <br />6. ALL SUPPLY AIR DIFFUSERS SHALL BE 4-WAY THROW UNLESS OTHERWISE NOTED. <br />17. <br />DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS (FREE <br />REFRIGERANT LINES AND CONDENSATE LINES. SUPPORTS SHALL BE PER DETAILS. <br />CONTRACTOR SHALL PAINT INSIDE EACH RETURN GRILLE'S PLENUM AND DUCT <br />AREA). <br />CONNECTION FLAT BLACK TO CONCEAL CONNECTION. COORDINATE AIR DEVICE <br />28. <br />ALL DOOR UNDERCUTS FOR THE PURPOSE OF BALANCING RETURN AIR SHALL BE <br />LOCATIONS WITH LIGHTING FIXTURES AND FIRE SPRINKLER HEADS. PRIOR TO <br />18. <br />CONTRACTOR SHALL COORDINATE ALL INTAKE/EXHAUST LOCATIONS TO INSURE <br />MINIMUM 1", PER FLORIDA BUILDING CODE - MECHANICAL - SECTION 601.6. <br />INSTALLATION, THE CONTRACTOR IS TO REFER TO THE ARCHITECTURAL <br />AT LEAST A 10' DISTANCE BETWEEN ANY INTAKES AND VENTILATION EXHAUSTS, <br />REFLECTED CEILING PLAN FOR ACTUAL FINAL LOCATIONS OF AIR DEVICES. <br />PLUMBING VENTS, RELIEF, ETC... <br />29. <br />MECHANICAL CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS <br />o <br />AND REQUIREMENTS OF ALL MECHANICAL EQUIPMENT WITH ELECTRICAL <br />3 7. DIFFUSERS/GRILLES SHALL NEVER BE INSTALLED ON SURFACE OF ACOUSTICAL <br />19. <br />ALL HVAC EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S <br />CONTRACTOR BEFORE BIDDING/ORDERING AND INSTALLATION. <br />LAY -IN TILE. ALL DIFFUSERS/GRILLES IN LAY -IN CEILINGS SHALL BE LAY -IN PANEL <br />RECOMMENDATIONS UNLESS INDICATED OTHERWISE. <br />= MOUNT. REFER TO SCHEDULE. GYPSUM BOARD SURFACE MOUNT DIFFUSERS <br />30. <br />ALL CONTROL WIRING SHALL BE INCLUDED AS PART OF MECHANICAL WORK. <br />SHALL NOT BE BEVEL MOUNT. <br />20. <br />CONTRACTOR SHALL THOROUGHLY CLEAN AND ENSURE PROPER OPERATION OF <br />REFER TO ELECTRICAL SPECIFICATIONS FOR CONDUIT AND WIRING <br />ANY EXISTING HVAC EQUIPMENT. ANY CHANGE TO THE SYSTEM SHALL RESULT IN <br />REQUIREMENTS. MECHANICAL CONTRACTOR SHALL ENSURE THAT ELECTRICAL <br />= 8. CONTRACTOR SHALL PROVIDE A COPY OF THE TEST AND BALANCE REPORT BY AN <br />EQUIPMENT MODIFICATIONS (AS REQUIRED) INCLUDING BUT NOT LIMITED TO <br />INTERFACE DEVICES NECESSARY IN THE ELECTRICAL COMPONENTS ARE <br />AABC OR NEBB CERTIFIED AGENCY. THIS REPORT MUST BE REVIEWED AND <br />REPLACING MOTORS, VFDS, PULLEYS, SHEAVES, BELTS, ETC... <br />COORDINATED WITH THE ELECTRICAL CONTRACTOR (IE FAN SPEED RHEOSTATS, <br />APPROVED BY THE ENGINEER PRIOR TO THE FINAL INSPECTION. THE <br />AUXILIARY CONTACTS, INTERLOCKS, ETC.) 62. UNLESS OTHERWISE NOTED <br />CONTRACTOR MUST ALSO PROVIDE ALL REPORTS REQUIRED BY THE <br />21. <br />CONTRACTOR SHALL PROVIDE A PERMANENT/PROFESSIONAL LABEL FOR EACH <br />MOTOR STARTERS AND DISCONNECTS SHALL BE FURNISHED AND INSTALLED BY <br />SPECIFICATION. OUTDOOR TEMPERATURE (DB); OUTSIDE AIR (DB/WB &CFM); <br />PIECE OF EQUIPMENT, ASSOCIATED THERMOSTAT(S) AND/OR SENSOR(S). <br />ELECTRICAL CONTRACTOR. <br />SUPPLY AIR AT UNIT DISCHARGE (DB/WB & CFM); RETURN AIR {MIXED) (DB/WB & <br />o CFM); LEAVING COIL (DB/WB); DIFFUSER/GRILLE (DB/WB); EQUIPMENT (EWT/LWT); <br />22. <br />DUCTWORK, DIFFUSERS, REGISTERS, GRILLES, AND OTHER ITEMS OF THE AIR <br />31. <br />CLOSE OUT DOCUMENTS: CONTRACTOR SHALL MAINTAIN A SET OF AS -BUILT <br />° EQUIPMENT (EAT/LAT); EQUIPMENT (GPM); EQUIPMENT (PRESSURES). OUTSIDE <br />HANDLING SYSTEM SHALL NOT BE SUPPORTED BY THE CEILING OR CEILING <br />DRAWINGS AND KEEP CURRENT DURING CONSTRUCTION OF THE PROJECT. IT IS <br />AIR CFM SHALL BE MEASURED DIRECTLY AND NOT CALCULATED FROM THE <br />SUSPENSION SYSTEM. <br />TO INCLUDE ALL CONTRACT CHANGES, MODIFICATIONS AND CLARIFICATIONS. <br />DIFFERENCE BETWEEN SUPPLY AIR CFM AND RETURN AIR CFM. <br />THIS SET TOGETHER WITH ALL SHOP DRAWINGS SHALL BE TURNED OVER TO THE <br />23. <br />LOW PRESSURE SUPPLY, RETURN, AND TRANSFER DUCTWORK SHALL BE <br />ARCHITECT/ENGINEER AFTER CONSTRUCTION COMPLETION. <br />Ll 9. ALL DUCTWORK MUST BE INSTALLED 6" AWAY FROM ANY FIRE RATED WALL TO <br />EXTERNALLY INSULATED SHEET METAL CONSTRUCTION IN ACCORDANCE WITH <br />51 FACILITATE INSPECTION. <br />LATEST SMACNA STANDARDS UNLESS OTHERWISE NOTED. DUCT INSULATION TO <br />BE 2.0" THICK FOIL BACK WRAP, K=0.25 BTUH-IN./SF. HR° 1.50#/CF AS <br />MANUFACTURED BY JOHNS MANVILLE. JOINTS TO BE STAPLED AND TAPED WITH <br />PRESSURE SENSITIVE TAPE (PER FMC 603) AS MANUFACTURED BY COMPAC <br />AREA NOT IN <br />75 CFM <br />SCOPE <br />.. o <br />AREA NOT IN <br />SCOPE <br />MECHANICAL & PLUMBING PLAN <br />SCALE: 3/1611 = 1$-0" <br />AL <br />T STRAP TO PREVEN <br />(INKS <br />PER SMACNA) <br />)UCT: DO NOT SAG <br />ISULATED, <br />i'-0" LONG (SAME <br />-FUSER NECK) <br />.ET METAL <br />HROUGH HELIX OF <br />)UCT, BAND CLAMP <br />* FLEXIBLE DUCT SHALL HAVE CONTINUOUS METAL LINER ENCASED BY INSULATING MATERIAL WITH AN OUTER <br />VAPOR JACKET CONFORMING TO UL181 UNLESS THE FLEX DUCT MEETS THE CRITERIA STATED IN 2017 FLORIDA <br />BUILDING CODE -BUILDING SECTION 449.3.6.4. <br />O CEILING DIFFUSER RUNOUT DETAIL NTS <br />12" <br />ACCOUSTICALLY <br />LINED SHEET METAL <br />RECTANGULAR OR PLENUM <br />ROUND SHEET METAL <br />DUCT. SEE PLANS <br />FOR SIZES. <br />RETURN AIR <br />GRILLE/REGISTER <br />NOTE: <br />SPRAY INTERIOR SURFACE VISIBLE FROM BEL <br />OW) LOW) WITH FLAT BLACK ENAMEL PAINT <br />Q RETURN AIR GRILLE DUCT CONNECTION DETAIL NTS <br />rn <br />0 <br />to <br />M <br />Cl) <br />U <br />J <br />F- <br />^ <br />z3�:O <br />Lv <br />0 <br />0QD <br />00 <br />U <br />o <br />O� <br />o <br />�(jFLd <br />- <br />zaF- <br />Of <br />0 <br />(n Q <br />U <br />m <br />L0 <br />(n <br />N <br />I- <br />Z LJ- <br />LLJ <br />J <br />U <br />W N <br />� d- <br />L0 <br />0� <br />�V)_j <br />LiJ <br />0YV) <br />C)f <br />U�J <br />= <br />L() >- <br />00 LIJ <br />)) N <br />Nichol Digitally signed by <br />' Nicholas Stephenson <br />DN: c=US, o=MES <br />GROUP INC, ou=MES <br />as GROUP INC, <br />cn=Nicholas <br />Ste p h Stephenson, <br />0.9.2342,19200 3 00.100 <br />1.1=A0109800000015 <br />E69A980DA0000076F <br />n s o n 14:16 29104 00'9 <br />Nicholas P Stephenson, PE <br />83283 <br />I CERTIFY TO THE BEST OF <br />MY KNOWLEDGE THAT THE <br />DRAWINGS & SPECIFICATIONS <br />COMPLY WITH THE <br />APPLICABLE MINIMUM <br />BUILDING CODES <br />N <br />o <br />V) <br />~ <br />Z <br />N <br />O <br />Z <br />Z <br />r <br />I <br />O <br />00 <br />Q <br />In <br />m <br />p <br />Q <br />UJ <br />Z <br />y <br />Lu <br />w <br />U <br />= <br />N <br />V) <br />U <br />_ <br />Q <br />SHEET NUMBER <br />mi 01 <br />