Laserfiche WebLink
OWNER'S BATHROOM <br />SCALE: 3/8" =1'-0" <br />0 <br />Eo <br />BATHROOM 2 <br />SCALE: 3/8" = 1'-0" <br />FILLED CELL LEGEND <br />CONT. FILLED CELL FROM FOUNDATION TO 211 <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />® FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18JX25J <br />S.H. <br />13 <br />20 X 38 <br />18' X 371 <br />S.H. <br />14 <br />20X50J <br />184X50 <br />S.H. <br />15 <br />20X63 <br />184X624 <br />S.H. <br />16 <br />20X72 <br />18JX714 <br />S.H. <br />1H2 <br />271/4X26 <br />26X25J <br />S.H. <br />1113 <br />27 1/4 X 38 J <br />26 x 37 <br />S.H. <br />1 H4 <br />27 4 X 501 <br />26 x 50 <br />S.H. <br />1 H5 <br />274 X 63 <br />26 X 62 1/2 <br />S.H. <br />1H6 <br />27X72 <br />26X711/2 <br />S.H. <br />22 <br />37JX26 <br />364X251/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 4 X 37 3/4 <br />S.H. <br />24 <br />37 a X 50 1 <br />36 J X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 J X 62 1/2 <br />S.H. <br />26 <br />37�X72 <br />36JX711/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 4 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 7'X 251 <br />S.H. <br />33 <br />54 X 38 J <br />52 J X 37 J <br />S.H. <br />34 <br />54 X 50 J <br />52 4 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 62 J <br />S.H. <br />36 <br />54 X 72 <br />52 J X 71 J <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />STAIR DATA: <br />18 RISERS @ 7.153" <br />42" KNEE WALL 17 TREADS @ 10" <br />WITH 1x8 CAP & TOTAL RISE =10'-8 3/4" <br />CASING (AT 2nd / TOTAL RUN = 14'-2" <br />FLOOR ONLY) // 3/4" PLYWOOD <br />(2) 2x8 w/ 112" // DECKING <br />FLITCH HEADER / <br />SLOPE CEILING TO / <br />/ <br />MATCH STAIR RISE <br />i <br />/ <br />F. FL. <br />17 � <br />Solo�/ 16 <br />AN,/ 15 <br />U 14 <br />Z // 13 <br />CONT. 12 <br />ual HAND RAIL 1.1 <br />U 10 <br />v � 9 �r <br />o� 8 <br />z 7 M� <br />600 °P <br />co <br />4 5 Zx STRINGERS <br />I F. FL. LJ1 <br />2x4 #2 SYP. P.T. THRUST , <br />BLOCK W/(2)-1/4"x 31/2" 14'-2" <br />TAPCONS @ 16"o.c. AND <br />3" FROM EA. END. TYP. STAIR SECTION <br />SCALE: 1/4" = l'-0" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />OH6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 71/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />DRYWALL <br />1 1/2" MIN. CLEARANCE <br />1 1/4" TO 2" DIA <br />HANDRAIL NO <br />LESS THAN 34" <br />NOR MORE <br />17 THAN 38" ABV. <br />TREAD NOSING <br />METAL <br />HANDRAIL <br />BRACKET <br />BLOCKING AS <br />REQUIRED <br />HANDRAIL DETAIL <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 318 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline, Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the dear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding % inch. A nosing projection not less than 314 inch and not more than 1114 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handrails: <br />al beprovidedo n ss t an one side of each continuous run of treads or flight with four or more <br />Handrails shall o of le h g <br />t measured vertically from the sloped lane adjoining the tread nosing, or finish surface of <br />risers. Handrail height me u d v rti ally f m p p I g g, <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 1112 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />VERIFY <br />AC PAD LOCATION OF <br />A/C PAD <br />HB <br />ON 111113 <br />1110 <br />on <br />• . • . i i <br />I:II <br />HIS <br />mi iui <br />Ii on • iiii <br />so Sol ■•ir <br />Ionuu nu <br />I <br />I <br />( F6- <br />7 <br />5-SH <br />REF 2468 BF <br />V <br />T-2" <br />I <br />o <br />O <br />2 <br />017 <br />-1 <br />Z <br />KITCHEN <br />9'-4" FLAT CLG. <br />I <br />TILE <br />SINK w/ <br />DISPOSAL <br />_D!W <br />CD <br />00 <br />in <br />LO <br />' c <br />112 WALL u <br />CAPPED <br />1 7- <br />2 UPS I = <br />3 a I� <br />4 <br />5 <br />PW01 <br />D1 <br />TYP. <br />7 <br />- <br />g01- <br />r <br />F <br />10 <br />i i <br />6" CNTR. AT 42" <br />A. F.F. <br />ti <br />GREAT ROOM <br />9'-4" FLAT CLG. <br />CARPET <br />GG <br />S3 <br />4'-4" <br />*NO UPL <br />Q <br />S4 <br />2868 <br />EDGE W.H. NI I BEYOND FWALLL SLAB 2" <br />6068 SGD <br />DINING <br />9'-4" FLAT CLG. <br />TILE <br />FLRG. LINE <br />FLRG. LIN <br />U)06 <br />o <br />� i N <br />FOYER <br />9'-4" FLAT CLG.: <br />01 <br />TILE o a <br />1- r <br />�? 9'-4" <br />BUILDER TO <br />PROVIDE <br />APPLIANCE <br />PROTECTION <br />WHEN <br />REQUIRED PER <br />FBC <br />1-CAR GARAGE <br />T-4" FLAT CLG. <br />CONCRETE <br />r------ <br />I <br />I <br />- - - - - - - - -- <br />I <br />I <br />I <br />LINE <br />I <br />F 2nd STRY. ABV. I <br />- <br />- <br />I * <br />NOTE** <br />BLK. WALLS <br />ARE 8'-8" <br />TALL FOR"A" <br />UNIT 5'-8" <br />FROM <br />FRONT OF <br />GARAGE <br />K <br />I <br />TYP. @ <br />I H <br />O <br />ARAGE S4 I <br />8'x7' . <br />ARAGE DOOR <br />IIIIIII� <br />. In nr■ri_�u <br />. 1 <br />nnrru� <br />soon <br />07��� <br />::: <br />M. OVA <br />■rr <br />ili <br />• <br />oom <br />• <br />' <br />go � <br />" <br />9 <br />roll <br />■ <br />V_8" <br />1ST FLOOR PLAN -UNIT-B 1516 <br />D <br />TYP. <br />SCALE: Ya'=T-0" <br />idnr.. <br />RFV in 1 9n r..AR <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />(*)>9'-0" <br />2x6 <br />SYP #2 <br />16" O.C. <br />* WHEN THE TOP OF WALL IS GREATER THAN 9'-0" <br />, THEN AT <br />EACH EXTERIOR CORNER WITHIN <br />STUDS WILL BE DOUBLE STUDS @ 1 <br />@12"O.C- <br />THIS IS ONLY USED WITH PLASTER <br />FINISH <br />** WALL SHEATHING 15/32" EXPOSU <br />REFER TO SHEATHING SCHEDULE <br />THE 4'-0" END ZONE, THE <br />6" O.C. OR SINGLE STUDS <br />OR STUCCO EXTERIOR I 3'-0" 12'-Q° 3`-4"01 <br />RE 1 0R EQUIVALENT. 2'-8" 3'-10" 5'-0" 3'-10" 3'-0" 01 <br />FOR ATTACHMENTS** I O <br />MOD 25 SH MOD 25 SH <br />( 39" x 59") { 39" x 59" ) <br />17-10 <br />�I <br />EGRESS EGRESS <br />00op <br />OWNER'S <br />BEDROOM <br />8'-0" FLAT CLG. V <br />CARPET 1 <br />04 <br />T <br />Eo <br />o? 17-8" is <br />7'-0" 4'-4" 6'-4" <br />R&S M.C. <br />----- <br />Pwo1 I ----- 22"x36" 0 13ATH <br />D1 I � ATTIC F-0" LAT CLG. 0 <br />W I l \ ACCESS C RPET <br />TYP. 00 <br />0 '-0" FLAT C� // m <br />�I 00 <br />CARPET) \ N N <br />I \/ I o) <br />I <br />I- - - - - - - - - - - <br />R&S <br />5 c 2868 CDP PW01 <br />6 D 1 _ o0 <br />00 <br />8 7, TYP. <br />g AH � co 36, <br />10 S OWER P <br />LID 11 I I R/A LO <br />3'-8" I 3'ki-_4,' 4--4" -1 1 <br />13 I I awl <br />I <br />14 I I w, LO <br />80 15 n ^00 <br />o0 <br />1 o� L FT N o I <br />I Ua I <br />17 I 8'-0' FLAT CLG. <br />18 IP l l ARPET <br />u OTA.F. <br />1/2 WALL <br />CAPPED b� <br />9'-6" N 1'-10" -4" a <br />2668 <br />'-0" LATCLG. <br />C RPET <br />M.C. <br />WIC <br />CV �' ti6�� 8'-0" FLAT CLG. <br />CARPET I <br />CD Ito <br />1� <br />EDROOM 2 _ __ 1 <br />8'-0" FLAT CLG. `� R&S <br />CARPET _777-717 1 11 11 <br />G.T. <br />- - <br />r� - <br />O o <br />LID <br />i9 <br />MOD 25 SH <br />(39"x59") <br />EGRESS <br />3'-10" 3'-10" T-8" 01 <br />7'-4" 4'-0" <br />14 <br />i" <br />1001 <br />in 11._4�� 7r_0�� 01 <br />18'-4" <br />2nd FLOOR PLAN - UNIT-B 1516 <br />SCALE: A"=V-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />0 +29.7 / -32.2 +29.7 / -39.7 <br />© +28.3 / -30.8 +28.3 / -37.0 <br />DE +26.6 / -29.1 �F +26.6 / -33.5 <br />GO SEE SN SHEET O SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATEp ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE +29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bl or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp, Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />W <br />uouuuuouoou■■i . . • � . <br />�l�r•r•�our.urroo■r•rr.r.��r • • <br />MASONRY PARTY WALL <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 664 S.F. <br />2ND FLOOR 849 S.F. <br />TOTAL 1513 S. F. <br />GARAGE 246 S.F. <br />LANAI 108 S. F. <br />ENTRY 98 S.F. <br />TOTAL SQ. FT. 1965 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONIC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />OG.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />C�cr) <br />t� CL` <br />r-- 0 _. <br />.0 i <br />CJN. <br />W <br />c <br />j. tp <br />fj <br />�%'t1�i� N <br />CEO'fu <br />P� <br />�fle S S I ®F� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />E <br />4 O co 8 c <br />0 <br />0 00 N N r <br />(A W Jnl 2 " <br />0) M it LL <br />C J LL <br />0 J u u- LL a <br />Lu <br />Z � _°'i It rz � <br />� @9 o <br />N <br />IL41 �2°'°' m <br />? 00 <br />N Z d <br />�K <br />Z o0 o <br />C13 <br />W <br />Q <br />Z cMv o <br />a <br />Z c N <br />Q � � <br />a <br />N <br />M <br />�N z a <br />_ o <br />4--� <br />LU <br />U <br />0 W a <br />(D- t/1 <br />un <br />U <br />W J <br />mks L 3 <br />U = <br />• <br />c � ri Q <br />N 8f <br />o Z <br />Z <br />CID <br />MZ <br />wo >o <br />E Wo k® <br />0 <br />V < 00 <br />�V <br />Z ~ o16 oz <br />O a~p aZ <br />O <o �w <br />J <br />L ¢o m0 <br />0 <br />Z C Z, <br />W <br />a) J ¢ ° z 0Z <br />$ate 30 <br />W a <br />E �w <br />yLL s3 <br />z �~ <br />o w� �_ <br />a� <br />rt za <br />c <br />o r <br />> d' <br />0 <br />�_ E <br />�- <br />r <br />CID <br />M a- - 4 <br />Lf� U (a/ <br />� O <br />_ O <br />E <br />_ N Ln <br />CD 0 <br />© N <br />N -" 6 <br />E � N z <br />Z E a @ <br />E c <br />o <br />CD <br />a_ U Q p <br />JOB NO : 22-06603-06596 <br />SCALE : AS NOTED <br />SHEET NO. <br />4 <br />2nd FLOOR PLAN - UNIT-B 1516 <br />SCALE: A"=V-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />0 +29.7 / -32.2 +29.7 / -39.7 <br />© +28.3 / -30.8 +28.3 / -37.0 <br />DE +26.6 / -29.1 �F +26.6 / -33.5 <br />GO SEE SN SHEET O SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATEp ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE +29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bl or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp, Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />W <br />uouuuuouoou■■i . . • � . <br />�l�r•r•�our.urroo■r•rr.r.��r • • <br />MASONRY PARTY WALL <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 664 S.F. <br />2ND FLOOR 849 S.F. <br />TOTAL 1513 S. F. <br />GARAGE 246 S.F. <br />LANAI 108 S. F. <br />ENTRY 98 S.F. <br />TOTAL SQ. FT. 1965 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONIC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />OG.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />C�cr) <br />t� CL` <br />r-- 0 _. <br />.0 i <br />CJN. <br />W <br />c <br />j. tp <br />fj <br />�%'t1�i� N <br />CEO'fu <br />P� <br />�fle S S I ®F� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />E <br />4 O co 8 c <br />0 <br />0 00 N N r <br />(A W Jnl 2 " <br />0) M it LL <br />C J LL <br />0 J u u- LL a <br />Lu <br />Z � _°'i It rz � <br />� @9 o <br />N <br />IL41 �2°'°' m <br />? 00 <br />N Z d <br />�K <br />Z o0 o <br />C13 <br />W <br />Q <br />Z cMv o <br />a <br />Z c N <br />Q � � <br />a <br />N <br />M <br />�N z a <br />_ o <br />4--� <br />LU <br />U <br />0 W a <br />(D- t/1 <br />un <br />U <br />W J <br />mks L 3 <br />U = <br />• <br />c � ri Q <br />N 8f <br />o Z <br />Z <br />CID <br />MZ <br />wo >o <br />E Wo k® <br />0 <br />V < 00 <br />�V <br />Z ~ o16 oz <br />O a~p aZ <br />O <o �w <br />J <br />L ¢o m0 <br />0 <br />Z C Z, <br />W <br />a) J ¢ ° z 0Z <br />$ate 30 <br />W a <br />E �w <br />yLL s3 <br />z �~ <br />o w� �_ <br />a� <br />rt za <br />c <br />o r <br />> d' <br />0 <br />�_ E <br />�- <br />r <br />CID <br />M a- - 4 <br />Lf� U (a/ <br />� O <br />_ O <br />E <br />_ N Ln <br />CD 0 <br />© N <br />N -" 6 <br />E � N z <br />Z E a @ <br />E c <br />o <br />CD <br />a_ U Q p <br />JOB NO : 22-06603-06596 <br />SCALE : AS NOTED <br />SHEET NO. <br />4 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bl or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp, Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />W <br />uouuuuouoou■■i . . • � . <br />�l�r•r•�our.urroo■r•rr.r.��r • • <br />MASONRY PARTY WALL <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 664 S.F. <br />2ND FLOOR 849 S.F. <br />TOTAL 1513 S. F. <br />GARAGE 246 S.F. <br />LANAI 108 S. F. <br />ENTRY 98 S.F. <br />TOTAL SQ. FT. 1965 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONIC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />OG.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />C�cr) <br />t� CL` <br />r-- 0 _. <br />.0 i <br />CJN. <br />W <br />c <br />j. tp <br />fj <br />�%'t1�i� N <br />CEO'fu <br />P� <br />�fle S S I ®F� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />E <br />4 O co 8 c <br />0 <br />0 00 N N r <br />(A W Jnl 2 " <br />0) M it LL <br />C J LL <br />0 J u u- LL a <br />Lu <br />Z � _°'i It rz � <br />� @9 o <br />N <br />IL41 �2°'°' m <br />? 00 <br />N Z d <br />�K <br />Z o0 o <br />C13 <br />W <br />Q <br />Z cMv o <br />a <br />Z c N <br />Q � � <br />a <br />N <br />M <br />�N z a <br />_ o <br />4--� <br />LU <br />U <br />0 W a <br />(D- t/1 <br />un <br />U <br />W J <br />mks L 3 <br />U = <br />• <br />c � ri Q <br />N 8f <br />o Z <br />Z <br />CID <br />MZ <br />wo >o <br />E Wo k® <br />0 <br />V < 00 <br />�V <br />Z ~ o16 oz <br />O a~p aZ <br />O <o �w <br />J <br />L ¢o m0 <br />0 <br />Z C Z, <br />W <br />a) J ¢ ° z 0Z <br />$ate 30 <br />W a <br />E �w <br />yLL s3 <br />z �~ <br />o w� �_ <br />a� <br />rt za <br />c <br />o r <br />> d' <br />0 <br />�_ E <br />�- <br />r <br />CID <br />M a- - 4 <br />Lf� U (a/ <br />� O <br />_ O <br />E <br />_ N Ln <br />CD 0 <br />© N <br />N -" 6 <br />E � N z <br />Z E a @ <br />E c <br />o <br />CD <br />a_ U Q p <br />JOB NO : 22-06603-06596 <br />SCALE : AS NOTED <br />SHEET NO. <br />4 <br />