OWNER'S BATHROOM
<br />SCALE: 3/8" =1'-0"
<br />0
<br />Eo
<br />BATHROOM 2
<br />SCALE: 3/8" = 1'-0"
<br />FILLED CELL LEGEND
<br />CONT. FILLED CELL FROM FOUNDATION TO 211
<br />FLOOR
<br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO
<br />LINTEL)
<br />® FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO
<br />BOND BEAM)
<br />WINDOW SCHEDULE
<br />SIZE
<br />R.O. CMU
<br />(Flange)
<br />R.O. FRAME
<br />(Fin)
<br />TYPE
<br />12
<br />20X26
<br />18JX25J
<br />S.H.
<br />13
<br />20 X 38
<br />18' X 371
<br />S.H.
<br />14
<br />20X50J
<br />184X50
<br />S.H.
<br />15
<br />20X63
<br />184X624
<br />S.H.
<br />16
<br />20X72
<br />18JX714
<br />S.H.
<br />1H2
<br />271/4X26
<br />26X25J
<br />S.H.
<br />1113
<br />27 1/4 X 38 J
<br />26 x 37
<br />S.H.
<br />1 H4
<br />27 4 X 501
<br />26 x 50
<br />S.H.
<br />1 H5
<br />274 X 63
<br />26 X 62 1/2
<br />S.H.
<br />1H6
<br />27X72
<br />26X711/2
<br />S.H.
<br />22
<br />37JX26
<br />364X251/2
<br />S.H.
<br />23
<br />37 J X 38 i
<br />36 4 X 37 3/4
<br />S.H.
<br />24
<br />37 a X 50 1
<br />36 J X 50
<br />S.H.
<br />25
<br />37 J X 63
<br />36 J X 62 1/2
<br />S.H.
<br />26
<br />37�X72
<br />36JX711/2
<br />S.H.
<br />DOUBLE 2 WIDE
<br />75" TALL
<br />73 4 WIDE
<br />S.H.
<br />32
<br />54 X 26
<br />52 7'X 251
<br />S.H.
<br />33
<br />54 X 38 J
<br />52 J X 37 J
<br />S.H.
<br />34
<br />54 X 50 J
<br />52 4 X 50
<br />S.H.
<br />35
<br />54 X 63
<br />52 J X 62 J
<br />S.H.
<br />36
<br />54 X 72
<br />52 J X 71 J
<br />S.H.
<br />39X59
<br />40 X 59
<br />N/A
<br />S.H.
<br />DOUBLE 39X59
<br />79 X 59
<br />N/A
<br />S.H.
<br />STAIR DATA:
<br />18 RISERS @ 7.153"
<br />42" KNEE WALL 17 TREADS @ 10"
<br />WITH 1x8 CAP & TOTAL RISE =10'-8 3/4"
<br />CASING (AT 2nd / TOTAL RUN = 14'-2"
<br />FLOOR ONLY) // 3/4" PLYWOOD
<br />(2) 2x8 w/ 112" // DECKING
<br />FLITCH HEADER /
<br />SLOPE CEILING TO /
<br />/
<br />MATCH STAIR RISE
<br />i
<br />/
<br />F. FL.
<br />17 �
<br />Solo�/ 16
<br />AN,/ 15
<br />U 14
<br />Z // 13
<br />CONT. 12
<br />ual HAND RAIL 1.1
<br />U 10
<br />v � 9 �r
<br />o� 8
<br />z 7 M�
<br />600 °P
<br />co
<br />4 5 Zx STRINGERS
<br />I F. FL. LJ1
<br />2x4 #2 SYP. P.T. THRUST ,
<br />BLOCK W/(2)-1/4"x 31/2" 14'-2"
<br />TAPCONS @ 16"o.c. AND
<br />3" FROM EA. END. TYP. STAIR SECTION
<br />SCALE: 1/4" = l'-0"
<br />HEADER SCHEDULE
<br />MARK
<br />HEADER SIZE
<br />REMARKS
<br />H 1
<br />(2) - 2X6 #2 SYP W/ 1/2"
<br />FLITCH PLATE
<br />H2
<br />(2) - 2X8 #2 SYP W/ 1/2"
<br />FLITCH PLATE
<br />H3
<br />(2) - 2X10 #2 SYP W/ 1/2"
<br />FLITCH PLATE
<br />H4
<br />(2) - 2X12 #2 SYP W/ 1/2"
<br />FLITCH PLATE
<br />H5
<br />(2) -1 3/4" X 11 1/4 LVL
<br />2.0E Fb=2950
<br />OH6
<br />(2) - 1 3/4" X 9 1/4"
<br />LVL 2.0E Fb=2950
<br />H7
<br />(2) -1 3/4" X 16"
<br />LVL 2.0E Fb=2950
<br />H8
<br />(2) - 1 3/4" X 71/4"
<br />LVL 2.0E Fb=2950
<br />(2) - 2X4 #2 SYP W/ 1/2"
<br />Follow Q/S4. See Plan for
<br />RAG
<br />FLITCH PLATE
<br />Bearing Wall Call Out When
<br />Straps are Required
<br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED
<br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND
<br />REQUIRED STUDS
<br />DRYWALL
<br />1 1/2" MIN. CLEARANCE
<br />1 1/4" TO 2" DIA
<br />HANDRAIL NO
<br />LESS THAN 34"
<br />NOR MORE
<br />17 THAN 38" ABV.
<br />TREAD NOSING
<br />METAL
<br />HANDRAIL
<br />BRACKET
<br />BLOCKING AS
<br />REQUIRED
<br />HANDRAIL DETAIL
<br />Stair and Railing General Notes
<br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312
<br />and R302.7.
<br />Riser height:
<br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading
<br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by
<br />more than 3/8 inch.
<br />Tread depth:
<br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the
<br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The
<br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 318 inch.
<br />Winders:
<br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the
<br />foremost projection of adjacent treads at the intersections with the walkline, Winder treads shall have a tread
<br />depth of not less than 6 inches at any point within the dear width of the stair.
<br />Nosings:
<br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than
<br />9/16 inch or a bevel not exceeding % inch. A nosing projection not less than 314 inch and not more than 1114
<br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing
<br />projection by more than 3/8 inch within a stairway.
<br />Handrails:
<br />al beprovidedo n ss t an one side of each continuous run of treads or flight with four or more
<br />Handrails shall o of le h g
<br />t measured vertically from the sloped lane adjoining the tread nosing, or finish surface of
<br />risers. Handrail height me u d v rti ally f m p p I g g,
<br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be
<br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly
<br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety
<br />terminals. Handrails adjacent to a wall shall have a space of not less than 1112 inches between the wall and the
<br />handrails.
<br />Grip -size:
<br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater
<br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3.
<br />Guards:
<br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings,
<br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches
<br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs,
<br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the
<br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have
<br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in
<br />diameter.
<br />Under -stair protection:
<br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and
<br />any soffits protected on the enclosed side with 1/2-inch gypsum board.
<br />VERIFY
<br />AC PAD LOCATION OF
<br />A/C PAD
<br />HB
<br />ON 111113
<br />1110
<br />on
<br />• . • . i i
<br />I:II
<br />HIS
<br />mi iui
<br />Ii on • iiii
<br />so Sol ■•ir
<br />Ionuu nu
<br />I
<br />I
<br />( F6-
<br />7
<br />5-SH
<br />REF 2468 BF
<br />V
<br />T-2"
<br />I
<br />o
<br />O
<br />2
<br />017
<br />-1
<br />Z
<br />KITCHEN
<br />9'-4" FLAT CLG.
<br />I
<br />TILE
<br />SINK w/
<br />DISPOSAL
<br />_D!W
<br />CD
<br />00
<br />in
<br />LO
<br />' c
<br />112 WALL u
<br />CAPPED
<br />1 7-
<br />2 UPS I =
<br />3 a I�
<br />4
<br />5
<br />PW01
<br />D1
<br />TYP.
<br />7
<br />-
<br />g01-
<br />r
<br />F
<br />10
<br />i i
<br />6" CNTR. AT 42"
<br />A. F.F.
<br />ti
<br />GREAT ROOM
<br />9'-4" FLAT CLG.
<br />CARPET
<br />GG
<br />S3
<br />4'-4"
<br />*NO UPL
<br />Q
<br />S4
<br />2868
<br />EDGE W.H. NI I BEYOND FWALLL SLAB 2"
<br />6068 SGD
<br />DINING
<br />9'-4" FLAT CLG.
<br />TILE
<br />FLRG. LINE
<br />FLRG. LIN
<br />U)06
<br />o
<br />� i N
<br />FOYER
<br />9'-4" FLAT CLG.:
<br />01
<br />TILE o a
<br />1- r
<br />�? 9'-4"
<br />BUILDER TO
<br />PROVIDE
<br />APPLIANCE
<br />PROTECTION
<br />WHEN
<br />REQUIRED PER
<br />FBC
<br />1-CAR GARAGE
<br />T-4" FLAT CLG.
<br />CONCRETE
<br />r------
<br />I
<br />I
<br />- - - - - - - - --
<br />I
<br />I
<br />I
<br />LINE
<br />I
<br />F 2nd STRY. ABV. I
<br />-
<br />-
<br />I *
<br />NOTE**
<br />BLK. WALLS
<br />ARE 8'-8"
<br />TALL FOR"A"
<br />UNIT 5'-8"
<br />FROM
<br />FRONT OF
<br />GARAGE
<br />K
<br />I
<br />TYP. @
<br />I H
<br />O
<br />ARAGE S4 I
<br />8'x7' .
<br />ARAGE DOOR
<br />IIIIIII�
<br />. In nr■ri_�u
<br />. 1
<br />nnrru�
<br />soon
<br />07���
<br />:::
<br />M. OVA
<br />■rr
<br />ili
<br />•
<br />oom
<br />•
<br />'
<br />go �
<br />"
<br />9
<br />roll
<br />■
<br />V_8"
<br />1ST FLOOR PLAN -UNIT-B 1516
<br />D
<br />TYP.
<br />SCALE: Ya'=T-0"
<br />idnr..
<br />RFV in 1 9n r..AR
<br />EXTERIOR 2ND FLOOR
<br />BEARING WALL SCHEDULE
<br />HEIGHT
<br />STUD
<br />SPECIES
<br />SPACING
<br />SPF #2
<br />8'-0"
<br />2x4
<br />SYP #2
<br />16" O.C.
<br />SPF #2
<br />9'-0"
<br />2x4
<br />SYP #2
<br />16" O.C.
<br />SPF #2
<br />(*)>9'-0"
<br />2x6
<br />SYP #2
<br />16" O.C.
<br />* WHEN THE TOP OF WALL IS GREATER THAN 9'-0"
<br />, THEN AT
<br />EACH EXTERIOR CORNER WITHIN
<br />STUDS WILL BE DOUBLE STUDS @ 1
<br />@12"O.C-
<br />THIS IS ONLY USED WITH PLASTER
<br />FINISH
<br />** WALL SHEATHING 15/32" EXPOSU
<br />REFER TO SHEATHING SCHEDULE
<br />THE 4'-0" END ZONE, THE
<br />6" O.C. OR SINGLE STUDS
<br />OR STUCCO EXTERIOR I 3'-0" 12'-Q° 3`-4"01
<br />RE 1 0R EQUIVALENT. 2'-8" 3'-10" 5'-0" 3'-10" 3'-0" 01
<br />FOR ATTACHMENTS** I O
<br />MOD 25 SH MOD 25 SH
<br />( 39" x 59") { 39" x 59" )
<br />17-10
<br />�I
<br />EGRESS EGRESS
<br />00op
<br />OWNER'S
<br />BEDROOM
<br />8'-0" FLAT CLG. V
<br />CARPET 1
<br />04
<br />T
<br />Eo
<br />o? 17-8" is
<br />7'-0" 4'-4" 6'-4"
<br />R&S M.C.
<br />-----
<br />Pwo1 I ----- 22"x36" 0 13ATH
<br />D1 I � ATTIC F-0" LAT CLG. 0
<br />W I l \ ACCESS C RPET
<br />TYP. 00
<br />0 '-0" FLAT C� // m
<br />�I 00
<br />CARPET) \ N N
<br />I \/ I o)
<br />I
<br />I- - - - - - - - - - -
<br />R&S
<br />5 c 2868 CDP PW01
<br />6 D 1 _ o0
<br />00
<br />8 7, TYP.
<br />g AH � co 36,
<br />10 S OWER P
<br />LID 11 I I R/A LO
<br />3'-8" I 3'ki-_4,' 4--4" -1 1
<br />13 I I awl
<br />I
<br />14 I I w, LO
<br />80 15 n ^00
<br />o0
<br />1 o� L FT N o I
<br />I Ua I
<br />17 I 8'-0' FLAT CLG.
<br />18 IP l l ARPET
<br />u OTA.F.
<br />1/2 WALL
<br />CAPPED b�
<br />9'-6" N 1'-10" -4" a
<br />2668
<br />'-0" LATCLG.
<br />C RPET
<br />M.C.
<br />WIC
<br />CV �' ti6�� 8'-0" FLAT CLG.
<br />CARPET I
<br />CD Ito
<br />1�
<br />EDROOM 2 _ __ 1
<br />8'-0" FLAT CLG. `� R&S
<br />CARPET _777-717 1 11 11
<br />G.T.
<br />- -
<br />r� -
<br />O o
<br />LID
<br />i9
<br />MOD 25 SH
<br />(39"x59")
<br />EGRESS
<br />3'-10" 3'-10" T-8" 01
<br />7'-4" 4'-0"
<br />14
<br />i"
<br />1001
<br />in 11._4�� 7r_0�� 01
<br />18'-4"
<br />2nd FLOOR PLAN - UNIT-B 1516
<br />SCALE: A"=V-0"
<br />OPENING PRESSURES
<br />ENCLOSED - EXPOSURE "C"
<br />0 +29.7 / -32.2 +29.7 / -39.7
<br />© +28.3 / -30.8 +28.3 / -37.0
<br />DE +26.6 / -29.1 �F +26.6 / -33.5
<br />GO SEE SN SHEET O SEE SN SHEET
<br />140 MPH
<br />NOTE: WIND SPEED INDICATEp ABOVE IS AN
<br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES
<br />LISTED ABOVE ARE ALLOWABLE PRESSURES
<br />SOFFIT DESIGN PRESSURE +29.7 / -39.7
<br />General Notes
<br />R302.5 Dwelling/Garage Opening/Penetration Protection
<br />Opening and penetrations through walls or ceilings separating the
<br />dwelling from the garage shall be in accordance with sections
<br />R302.5.1 through R302.5.3.
<br />R302.5.1 Opening Protection
<br />Openings from a private garage directly into a room used for
<br />sleeping purposes shall not be permitted. Other openings between
<br />the garage and residence shall be equipped with solid wood doors
<br />not less than 1-3/8" in thickness, solid or honeycomb -core steel
<br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors.
<br />R302.5.2 Duct Penetration
<br />Ducts in the garage and ducts penetrating the walls or ceilings
<br />separating the dwelling from the garage shall be constructed of a
<br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid
<br />nonmetallic class 0 or classl duct board, or other approved
<br />material and shall not have openings into the garage.
<br />R302.5.3 Other Penetrations
<br />Penetrations through the separation required in Section R302.6
<br />shall be protected as required by section R302.11, Item 4.
<br />R302.6 Dwelling/Garage Fire Separation.
<br />The garage shall be separated as required by Table R302.6.
<br />Openings in garage walls shall comply with Section R302.5.
<br />Attachment of gypsum board shall comply with Tab;e R702.3.5.
<br />The wall separation provisions of Table R302.6 shall not apply to
<br />garage walls that are perpendicular to the adjacent dwelling unit
<br />wall:
<br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or
<br />equivalent applied to garage side.
<br />• From Habitable Rooms Above Garage - Not Less than 5/8"
<br />Type-X Gyp. Bl or equivalent.
<br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less
<br />than 1/2" Gyp, Bd. or equivalent.
<br />• Garages Located Less Than 3 Feet From Dwelling On The
<br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied
<br />to the interior side of exterior walls that are within this area.
<br />R312.2.1 Window Sills
<br />In dwelling units, where the top of the sill of an operable window is
<br />located less than 24 inches (610 mm) above the finished floor and
<br />greater than 72 inches (1829 mm) above the finished grade or
<br />other surface below on the exterior of the building, the operable
<br />window shall comply with one of the following: 1. Operable
<br />windows with openings that will not allow a 4-inch-diameter (102
<br />mm) sphere to pass through the opening where the opening is in
<br />its largest opened position. 2. Operable windows that are provided
<br />with window fall prevention devices that comply with ASTM F2090.
<br />3. Operable windows that are provided with window opening
<br />control devices that comply with Section R312.2.2.
<br />Chapter 45 Private Swimming Pools
<br />Outdoor swimming pools shall be provided with a barrier
<br />complying with R4501.17.1.1 through R4501.17.1.14.
<br />M1507.2 Re -circulation of Air
<br />Exhaust air form Bathrooms and toilet rooms shall not be
<br />re -circulated within a residence or to another dwelling unit and
<br />shall be exhausted directly to the outdoors. Exhaust air from
<br />bathrooms and toilet rooms shall not discharge into an attic, crawl
<br />space or other areas inside the building.
<br />GAS APPLIANCES
<br />G.C. to verify location of gas riser before commencement of work.
<br />Where gas water heaters are installed. Water heaters shall be
<br />installed a min. of 18" above fir. per FBCR G2408.2. Except where
<br />appliances that are listed as flammable vapor ignition resistant.
<br />WALL LEGEND
<br />2-STORY MASONRY WALL w/
<br />BOND BEAM HGT. AT 10'-8"
<br />TOP AT 18'-8"
<br />W
<br />uouuuuouoou■■i . . • � .
<br />�l�r•r•�our.urroo■r•rr.r.��r • •
<br />MASONRY PARTY WALL
<br />TYP. 2x FRAME WALL
<br />BEARING WALL
<br />INTERIOR BEARING WALLS NOTED "FLOOR
<br />BEARING ONLY" ARE FLOOR SYSTEM
<br />SUPPORTING ONLY AND REQUIRES NO UPLIFT
<br />CONNECTORS TO FLOOR SYSTEM
<br />AREA TABULATION
<br />1ST FLOOR 664 S.F.
<br />2ND FLOOR 849 S.F.
<br />TOTAL 1513 S. F.
<br />GARAGE 246 S.F.
<br />LANAI 108 S. F.
<br />ENTRY 98 S.F.
<br />TOTAL SQ. FT. 1965 S.F.
<br />INSULATION REQ.
<br />LOCATION R-VALUE / TYPE
<br />EXT CONIC WALL R-4.1 HIGH PERM
<br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED
<br />EXT FRAME 2 x 6 R-19 KRAFT FACED
<br />CONDITIONED CEILING R-30 BLOWN -IN
<br />(INSTALL BAFFELS AT EAVE)
<br />GARAGE SEPARATION R-11/R-13 KRAFT FACED
<br />(GARAGE / LIVING)
<br />OG.C. TO COORDINATE PLUMBING TO AVOID
<br />CONFLICT WITH STRUCTURAL WD. COL.
<br />C�cr)
<br />t� CL`
<br />r-- 0 _.
<br />.0 i
<br />CJN.
<br />W
<br />c
<br />j. tp
<br />fj
<br />�%'t1�i� N
<br />CEO'fu
<br />P�
<br />�fle S S I ®F�
<br />To the best of the Engineer's knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineer's signature and seal is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineer's signature and seal.
<br />W
<br />E
<br />4 O co 8 c
<br />0
<br />0 00 N N r
<br />(A W Jnl 2 "
<br />0) M it LL
<br />C J LL
<br />0 J u u- LL a
<br />Lu
<br />Z � _°'i It rz �
<br />� @9 o
<br />N
<br />IL41 �2°'°' m
<br />? 00
<br />N Z d
<br />�K
<br />Z o0 o
<br />C13
<br />W
<br />Q
<br />Z cMv o
<br />a
<br />Z c N
<br />Q � �
<br />a
<br />N
<br />M
<br />�N z a
<br />_ o
<br />4--�
<br />LU
<br />U
<br />0 W a
<br />(D- t/1
<br />un
<br />U
<br />W J
<br />mks L 3
<br />U =
<br />•
<br />c � ri Q
<br />N 8f
<br />o Z
<br />Z
<br />CID
<br />MZ
<br />wo >o
<br />E Wo k®
<br />0
<br />V < 00
<br />�V
<br />Z ~ o16 oz
<br />O a~p aZ
<br />O <o �w
<br />J
<br />L ¢o m0
<br />0
<br />Z C Z,
<br />W
<br />a) J ¢ ° z 0Z
<br />$ate 30
<br />W a
<br />E �w
<br />yLL s3
<br />z �~
<br />o w� �_
<br />a�
<br />rt za
<br />c
<br />o r
<br />> d'
<br />0
<br />�_ E
<br />�-
<br />r
<br />CID
<br />M a- - 4
<br />Lf� U (a/
<br />� O
<br />_ O
<br />E
<br />_ N Ln
<br />CD 0
<br />© N
<br />N -" 6
<br />E � N z
<br />Z E a @
<br />E c
<br />o
<br />CD
<br />a_ U Q p
<br />JOB NO : 22-06603-06596
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />4
<br />2nd FLOOR PLAN - UNIT-B 1516
<br />SCALE: A"=V-0"
<br />OPENING PRESSURES
<br />ENCLOSED - EXPOSURE "C"
<br />0 +29.7 / -32.2 +29.7 / -39.7
<br />© +28.3 / -30.8 +28.3 / -37.0
<br />DE +26.6 / -29.1 �F +26.6 / -33.5
<br />GO SEE SN SHEET O SEE SN SHEET
<br />140 MPH
<br />NOTE: WIND SPEED INDICATEp ABOVE IS AN
<br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES
<br />LISTED ABOVE ARE ALLOWABLE PRESSURES
<br />SOFFIT DESIGN PRESSURE +29.7 / -39.7
<br />General Notes
<br />R302.5 Dwelling/Garage Opening/Penetration Protection
<br />Opening and penetrations through walls or ceilings separating the
<br />dwelling from the garage shall be in accordance with sections
<br />R302.5.1 through R302.5.3.
<br />R302.5.1 Opening Protection
<br />Openings from a private garage directly into a room used for
<br />sleeping purposes shall not be permitted. Other openings between
<br />the garage and residence shall be equipped with solid wood doors
<br />not less than 1-3/8" in thickness, solid or honeycomb -core steel
<br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors.
<br />R302.5.2 Duct Penetration
<br />Ducts in the garage and ducts penetrating the walls or ceilings
<br />separating the dwelling from the garage shall be constructed of a
<br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid
<br />nonmetallic class 0 or classl duct board, or other approved
<br />material and shall not have openings into the garage.
<br />R302.5.3 Other Penetrations
<br />Penetrations through the separation required in Section R302.6
<br />shall be protected as required by section R302.11, Item 4.
<br />R302.6 Dwelling/Garage Fire Separation.
<br />The garage shall be separated as required by Table R302.6.
<br />Openings in garage walls shall comply with Section R302.5.
<br />Attachment of gypsum board shall comply with Tab;e R702.3.5.
<br />The wall separation provisions of Table R302.6 shall not apply to
<br />garage walls that are perpendicular to the adjacent dwelling unit
<br />wall:
<br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or
<br />equivalent applied to garage side.
<br />• From Habitable Rooms Above Garage - Not Less than 5/8"
<br />Type-X Gyp. Bl or equivalent.
<br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less
<br />than 1/2" Gyp, Bd. or equivalent.
<br />• Garages Located Less Than 3 Feet From Dwelling On The
<br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied
<br />to the interior side of exterior walls that are within this area.
<br />R312.2.1 Window Sills
<br />In dwelling units, where the top of the sill of an operable window is
<br />located less than 24 inches (610 mm) above the finished floor and
<br />greater than 72 inches (1829 mm) above the finished grade or
<br />other surface below on the exterior of the building, the operable
<br />window shall comply with one of the following: 1. Operable
<br />windows with openings that will not allow a 4-inch-diameter (102
<br />mm) sphere to pass through the opening where the opening is in
<br />its largest opened position. 2. Operable windows that are provided
<br />with window fall prevention devices that comply with ASTM F2090.
<br />3. Operable windows that are provided with window opening
<br />control devices that comply with Section R312.2.2.
<br />Chapter 45 Private Swimming Pools
<br />Outdoor swimming pools shall be provided with a barrier
<br />complying with R4501.17.1.1 through R4501.17.1.14.
<br />M1507.2 Re -circulation of Air
<br />Exhaust air form Bathrooms and toilet rooms shall not be
<br />re -circulated within a residence or to another dwelling unit and
<br />shall be exhausted directly to the outdoors. Exhaust air from
<br />bathrooms and toilet rooms shall not discharge into an attic, crawl
<br />space or other areas inside the building.
<br />GAS APPLIANCES
<br />G.C. to verify location of gas riser before commencement of work.
<br />Where gas water heaters are installed. Water heaters shall be
<br />installed a min. of 18" above fir. per FBCR G2408.2. Except where
<br />appliances that are listed as flammable vapor ignition resistant.
<br />WALL LEGEND
<br />2-STORY MASONRY WALL w/
<br />BOND BEAM HGT. AT 10'-8"
<br />TOP AT 18'-8"
<br />W
<br />uouuuuouoou■■i . . • � .
<br />�l�r•r•�our.urroo■r•rr.r.��r • •
<br />MASONRY PARTY WALL
<br />TYP. 2x FRAME WALL
<br />BEARING WALL
<br />INTERIOR BEARING WALLS NOTED "FLOOR
<br />BEARING ONLY" ARE FLOOR SYSTEM
<br />SUPPORTING ONLY AND REQUIRES NO UPLIFT
<br />CONNECTORS TO FLOOR SYSTEM
<br />AREA TABULATION
<br />1ST FLOOR 664 S.F.
<br />2ND FLOOR 849 S.F.
<br />TOTAL 1513 S. F.
<br />GARAGE 246 S.F.
<br />LANAI 108 S. F.
<br />ENTRY 98 S.F.
<br />TOTAL SQ. FT. 1965 S.F.
<br />INSULATION REQ.
<br />LOCATION R-VALUE / TYPE
<br />EXT CONIC WALL R-4.1 HIGH PERM
<br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED
<br />EXT FRAME 2 x 6 R-19 KRAFT FACED
<br />CONDITIONED CEILING R-30 BLOWN -IN
<br />(INSTALL BAFFELS AT EAVE)
<br />GARAGE SEPARATION R-11/R-13 KRAFT FACED
<br />(GARAGE / LIVING)
<br />OG.C. TO COORDINATE PLUMBING TO AVOID
<br />CONFLICT WITH STRUCTURAL WD. COL.
<br />C�cr)
<br />t� CL`
<br />r-- 0 _.
<br />.0 i
<br />CJN.
<br />W
<br />c
<br />j. tp
<br />fj
<br />�%'t1�i� N
<br />CEO'fu
<br />P�
<br />�fle S S I ®F�
<br />To the best of the Engineer's knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineer's signature and seal is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineer's signature and seal.
<br />W
<br />E
<br />4 O co 8 c
<br />0
<br />0 00 N N r
<br />(A W Jnl 2 "
<br />0) M it LL
<br />C J LL
<br />0 J u u- LL a
<br />Lu
<br />Z � _°'i It rz �
<br />� @9 o
<br />N
<br />IL41 �2°'°' m
<br />? 00
<br />N Z d
<br />�K
<br />Z o0 o
<br />C13
<br />W
<br />Q
<br />Z cMv o
<br />a
<br />Z c N
<br />Q � �
<br />a
<br />N
<br />M
<br />�N z a
<br />_ o
<br />4--�
<br />LU
<br />U
<br />0 W a
<br />(D- t/1
<br />un
<br />U
<br />W J
<br />mks L 3
<br />U =
<br />•
<br />c � ri Q
<br />N 8f
<br />o Z
<br />Z
<br />CID
<br />MZ
<br />wo >o
<br />E Wo k®
<br />0
<br />V < 00
<br />�V
<br />Z ~ o16 oz
<br />O a~p aZ
<br />O <o �w
<br />J
<br />L ¢o m0
<br />0
<br />Z C Z,
<br />W
<br />a) J ¢ ° z 0Z
<br />$ate 30
<br />W a
<br />E �w
<br />yLL s3
<br />z �~
<br />o w� �_
<br />a�
<br />rt za
<br />c
<br />o r
<br />> d'
<br />0
<br />�_ E
<br />�-
<br />r
<br />CID
<br />M a- - 4
<br />Lf� U (a/
<br />� O
<br />_ O
<br />E
<br />_ N Ln
<br />CD 0
<br />© N
<br />N -" 6
<br />E � N z
<br />Z E a @
<br />E c
<br />o
<br />CD
<br />a_ U Q p
<br />JOB NO : 22-06603-06596
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />4
<br />General Notes
<br />R302.5 Dwelling/Garage Opening/Penetration Protection
<br />Opening and penetrations through walls or ceilings separating the
<br />dwelling from the garage shall be in accordance with sections
<br />R302.5.1 through R302.5.3.
<br />R302.5.1 Opening Protection
<br />Openings from a private garage directly into a room used for
<br />sleeping purposes shall not be permitted. Other openings between
<br />the garage and residence shall be equipped with solid wood doors
<br />not less than 1-3/8" in thickness, solid or honeycomb -core steel
<br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors.
<br />R302.5.2 Duct Penetration
<br />Ducts in the garage and ducts penetrating the walls or ceilings
<br />separating the dwelling from the garage shall be constructed of a
<br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid
<br />nonmetallic class 0 or classl duct board, or other approved
<br />material and shall not have openings into the garage.
<br />R302.5.3 Other Penetrations
<br />Penetrations through the separation required in Section R302.6
<br />shall be protected as required by section R302.11, Item 4.
<br />R302.6 Dwelling/Garage Fire Separation.
<br />The garage shall be separated as required by Table R302.6.
<br />Openings in garage walls shall comply with Section R302.5.
<br />Attachment of gypsum board shall comply with Tab;e R702.3.5.
<br />The wall separation provisions of Table R302.6 shall not apply to
<br />garage walls that are perpendicular to the adjacent dwelling unit
<br />wall:
<br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or
<br />equivalent applied to garage side.
<br />• From Habitable Rooms Above Garage - Not Less than 5/8"
<br />Type-X Gyp. Bl or equivalent.
<br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less
<br />than 1/2" Gyp, Bd. or equivalent.
<br />• Garages Located Less Than 3 Feet From Dwelling On The
<br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied
<br />to the interior side of exterior walls that are within this area.
<br />R312.2.1 Window Sills
<br />In dwelling units, where the top of the sill of an operable window is
<br />located less than 24 inches (610 mm) above the finished floor and
<br />greater than 72 inches (1829 mm) above the finished grade or
<br />other surface below on the exterior of the building, the operable
<br />window shall comply with one of the following: 1. Operable
<br />windows with openings that will not allow a 4-inch-diameter (102
<br />mm) sphere to pass through the opening where the opening is in
<br />its largest opened position. 2. Operable windows that are provided
<br />with window fall prevention devices that comply with ASTM F2090.
<br />3. Operable windows that are provided with window opening
<br />control devices that comply with Section R312.2.2.
<br />Chapter 45 Private Swimming Pools
<br />Outdoor swimming pools shall be provided with a barrier
<br />complying with R4501.17.1.1 through R4501.17.1.14.
<br />M1507.2 Re -circulation of Air
<br />Exhaust air form Bathrooms and toilet rooms shall not be
<br />re -circulated within a residence or to another dwelling unit and
<br />shall be exhausted directly to the outdoors. Exhaust air from
<br />bathrooms and toilet rooms shall not discharge into an attic, crawl
<br />space or other areas inside the building.
<br />GAS APPLIANCES
<br />G.C. to verify location of gas riser before commencement of work.
<br />Where gas water heaters are installed. Water heaters shall be
<br />installed a min. of 18" above fir. per FBCR G2408.2. Except where
<br />appliances that are listed as flammable vapor ignition resistant.
<br />WALL LEGEND
<br />2-STORY MASONRY WALL w/
<br />BOND BEAM HGT. AT 10'-8"
<br />TOP AT 18'-8"
<br />W
<br />uouuuuouoou■■i . . • � .
<br />�l�r•r•�our.urroo■r•rr.r.��r • •
<br />MASONRY PARTY WALL
<br />TYP. 2x FRAME WALL
<br />BEARING WALL
<br />INTERIOR BEARING WALLS NOTED "FLOOR
<br />BEARING ONLY" ARE FLOOR SYSTEM
<br />SUPPORTING ONLY AND REQUIRES NO UPLIFT
<br />CONNECTORS TO FLOOR SYSTEM
<br />AREA TABULATION
<br />1ST FLOOR 664 S.F.
<br />2ND FLOOR 849 S.F.
<br />TOTAL 1513 S. F.
<br />GARAGE 246 S.F.
<br />LANAI 108 S. F.
<br />ENTRY 98 S.F.
<br />TOTAL SQ. FT. 1965 S.F.
<br />INSULATION REQ.
<br />LOCATION R-VALUE / TYPE
<br />EXT CONIC WALL R-4.1 HIGH PERM
<br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED
<br />EXT FRAME 2 x 6 R-19 KRAFT FACED
<br />CONDITIONED CEILING R-30 BLOWN -IN
<br />(INSTALL BAFFELS AT EAVE)
<br />GARAGE SEPARATION R-11/R-13 KRAFT FACED
<br />(GARAGE / LIVING)
<br />OG.C. TO COORDINATE PLUMBING TO AVOID
<br />CONFLICT WITH STRUCTURAL WD. COL.
<br />C�cr)
<br />t� CL`
<br />r-- 0 _.
<br />.0 i
<br />CJN.
<br />W
<br />c
<br />j. tp
<br />fj
<br />�%'t1�i� N
<br />CEO'fu
<br />P�
<br />�fle S S I ®F�
<br />To the best of the Engineer's knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineer's signature and seal is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineer's signature and seal.
<br />W
<br />E
<br />4 O co 8 c
<br />0
<br />0 00 N N r
<br />(A W Jnl 2 "
<br />0) M it LL
<br />C J LL
<br />0 J u u- LL a
<br />Lu
<br />Z � _°'i It rz �
<br />� @9 o
<br />N
<br />IL41 �2°'°' m
<br />? 00
<br />N Z d
<br />�K
<br />Z o0 o
<br />C13
<br />W
<br />Q
<br />Z cMv o
<br />a
<br />Z c N
<br />Q � �
<br />a
<br />N
<br />M
<br />�N z a
<br />_ o
<br />4--�
<br />LU
<br />U
<br />0 W a
<br />(D- t/1
<br />un
<br />U
<br />W J
<br />mks L 3
<br />U =
<br />•
<br />c � ri Q
<br />N 8f
<br />o Z
<br />Z
<br />CID
<br />MZ
<br />wo >o
<br />E Wo k®
<br />0
<br />V < 00
<br />�V
<br />Z ~ o16 oz
<br />O a~p aZ
<br />O <o �w
<br />J
<br />L ¢o m0
<br />0
<br />Z C Z,
<br />W
<br />a) J ¢ ° z 0Z
<br />$ate 30
<br />W a
<br />E �w
<br />yLL s3
<br />z �~
<br />o w� �_
<br />a�
<br />rt za
<br />c
<br />o r
<br />> d'
<br />0
<br />�_ E
<br />�-
<br />r
<br />CID
<br />M a- - 4
<br />Lf� U (a/
<br />� O
<br />_ O
<br />E
<br />_ N Ln
<br />CD 0
<br />© N
<br />N -" 6
<br />E � N z
<br />Z E a @
<br />E c
<br />o
<br />CD
<br />a_ U Q p
<br />JOB NO : 22-06603-06596
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />4
<br />
|