Laserfiche WebLink
• <br />BUILDING SPECIFICATIONS <br />The building system shown on these drawings has been designed and detailed for the loads and conditions <br />stipulated by the letter of certification, and these drawings. <br />Any alterations to this building system, removal of any of its components or parts, modification of the intended <br />end —use, modifications in cladding or any other deviations from the original conditions for which the building <br />system was designed may be done only with the written approval of a registered architect and/or a registered <br />professional engineer, as applicable. The metal building manufacturer (MBM) will assume no responsibility for any <br />of the changes mentioned above if performed without prior written approval by the MBM. <br />This building system has been designed per the MBM's standard design and manufacturing practices, the governing <br />building code, and the applicable editions of the building code referenced AISC, AISI, ASCE, and AWS standards. <br />This building system has also been designed in accordance with all applicable provisions of the latest edition of <br />MBMA Metal Building Systems Manual. In applications including structural steel deck and steel joists, the code <br />referenced editions of applicable SDI and SJI standards, respectively, were also applied. <br />The MBM does not design or check ventilation or energy conservation systems for the building system supplied and <br />is not responsible for the adequacy of specified ventilation and energy conservation components. The End User <br />should insure that adequate provisions are made for ventilation, condensation, and energy conservation requirements. <br />The MBM is not responsible for the design, materials and workmanship of the foundation, or the anchorage of the <br />building system to the foundation. Anchor bolt plans prepared by the MBM are intended to show only location, <br />diameter, and projection of anchor bolts required to attach the metal building system to the foundation. The END <br />USER is responsible for engaging the services of a licensed Professional Engineer to perform foundation and <br />foundation anchorage design. <br />The Professional Engineer designing the foundation shall determine the adequate anchor bolt material type and <br />grade, anchor bolt embedment, and any anchorage reinforcement to accommodate the given anchor bolt locations, <br />quantity, and diameter. <br />Unless noted otherwise on the Letter of Certification, the building system by the MBM is exempt from the ASCE <br />7 stipulated seismic drift limitations. The END USER shall insure that all the interior and exterior attachments <br />and cladding by others are designed to accommodate seismic drift. <br />The MBM does not investigate the influence of its metal building system on existing buildings or structures. The <br />END USER shall engage services of a licensed Professional Engineer to evaluate whether such buildings and <br />structures are adequate to resist snow drift loads or other conditions as a result of the presence of the Metal <br />Building System. The materials used in fabrication of primary and secondary steel framing members, as well as <br />related accessories are shown below with their corresponding ASTM designations. When the compliance with the <br />building code mandated edition of the AISC Seismic Provisions is required, only materials approved by those <br />provisions are used. <br />Built—up Section Flanges (Fy = 55 ksi); A529, A572 or A588; <br />Built—up Section Webs & Connection Plates (Fy = 55 ksi); A1011, A572 or A588; <br />Hot —rolled W—shapes (Fy = 50 ksi); A992 or A572; <br />Hot —rolled C and L—shapes (Fy = 50 ksi); A529 or A572; <br />Hot —rolled Rods (Fy = 55 ksi); A108 or A572; <br />Cold —formed C, Z, and ES shapes (Fy = 55 ksi); A1011 or A653; <br />Panels, A792 or A653, Gr. 50 for Ga. 24 and thicker, Gr. 80 for others; <br />HSS Round; A500 Gr. 8 (Fy = 42 ksi) <br />HSS Square/Rectangular; A500 Gr. B (Fy = 46 ksi) <br />Cables, A475 <br />Eyebolts (Gr. 55); A108, or A572 <br />Washers, A536 <br />Hillside Washers, A48 <br />Structural Bolts, A307 Gr. A, A325 Gr. C, A490 Gr. DH <br />(used as noted in next section) . <br />Unless noted otherwise and except for crane support system connections, all bolted joints shall be snug —tightened <br />in accordance with the latest edition of Specification for Structural Joints Using ASTM A325, or A490 Bolts <br />(RCSC). All joints in crane support system application shall be pretensioned as required by RCSC. All primary <br />frame bolted connections use A325 bolts, unless noted otherwise. All end —plate connections in cold —formed steel <br />frames use A325 bolts, unless noted otherwise. <br />All primary structural members have been painted with the minimum of one coat of iron oxide inhibitive primer. <br />All structural steel members have been painted in accordance with Steel Structures Painting Council Specification, <br />SSPC No. 15. <br />Shop and field inspections and associated fees and expenses are the responsibility of the contractor, unless noted <br />otherwise. <br />BUYER or CONTRACTOR RESPONSIBILITIES <br />The BUYER or CONTRACTOR must secure all required approvals and permits for this project from the <br />appropriate agencies in full compliance with all applicable local and state laws and regulations. In accordance with <br />the Sec. 4.4.1 of the latest edition of the AISC Code of Standard Practice and the MBMA Common Industry <br />Practices. Approval of these drawings and calculations (if applicable) constitutes an agreement that the MBM has <br />correctly interpreted the requirements of the contract building drawings, specifications, and all other contractual <br />requirements. <br />In accordance with Sec. 3.3 of the latest edition of the AISC Code of Standard Practice, where discrepancies <br />exist between drawings provided by the MBM and the drawings provided by the other trades, such as <br />architectural, electrical, plumbing, and others, these drawings provided by the MBM shall govern. <br />The BUYER or CONTRACTOR is responsible for the erection of the entire building system and all associated work <br />pertaining thereto in accordance with the MBM's "For Construction" drawings. Drawings not marked "For <br />Construction" SHALL NOT be used in the erection of the MBM's building system. <br />In accordance with Sec. 7.10.3 of the latest edition of the AISC Code of Standard Practice, temporary supports <br />such as guys, braces, falsework, shoring, and other elements necessary to safely erect the building system and <br />prevent structural and other damage to the building system shall be determined and furnished by the erector. <br />The structural building system provided by the MBM is designed for service conditions in accordance with the <br />building code. The BUYER or CONTRACTOR shall erect the system in a manner that insures that the loading <br />conditions on the structure during service are not exceeded in any part of the structure throughout the erection <br />process. <br />Unless noted otherwise, the MBM shall not be responsible for the design of any elements of this project not part <br />of the structural building system provided by the MBM. The BUYER or CONTRACTOR shall be responsible for <br />taking appropriate steps to insure that such elements are properly structurally designed and constructed. <br />It is the responsibility of the BUYER or CONTRACTOR to observe and apply all pertinent OSHA and other <br />mandatory safety provisions. <br />The BUYER or CONTRACTOR is responsible for the inspection of all of the MBM's shipment when received. Any <br />claims of non —received items must be reported to the MBM in writing within 5 business days. In order to <br />maintain the quality guarantee and to qualify for reimbursement, any field modifications of any reported defective <br />item may not be performed without a prior written endorsement by the MBM. <br />THE MBM shall not be held liable for any claim whatsoever, including, but not limited to, labor charges or <br />consequential damages, resulting from the BUYER or CONTRACTOR/Erectors use of defective or incorrect <br />materials that can be detected by visual inspection. <br />THE MBM is not responsible for material damaged in unloading or for packaged or nested materials, including, but <br />not limited to, fasteners, sheet metal, "C" and "Z" sections, and covering panels that become wet and/or are <br />damaged by water while in the possession of others. Packaged or nested materials that become wet in transit <br />shall be unpacked, unstacked and dried by the BUYER or CONTRACTOR. <br />With respect to all other building system erection aspects not mentioned above, the BUYER or CONTRACTOR shall <br />comply with the Sec. 6 of the MBMA Common Industry Practices. For any aspects of the erection not covered by <br />the MBMA Common Industry Practices, the provisions of Sec. 7 of the latest edition of the AISC Code of <br />Standard Practice shall apply. <br />ENGINEERING SEAL <br />This certification covers parts <br />fabricated and delivered by the <br />manufacturer only and excludes <br />parts such as doors, windows, <br />foundation design, and erection of <br />the building. Sealed drawings do <br />not constitute an agreement that <br />the signed engineer is acting as <br />the engineer of record for the <br />overall project. <br />KEITH SHEDD <br />459 WOODLAND RD <br />BATESVILLE, MS. 38606 <br />PE# 48014 <br />`%��1uuuu,, <br />,� <br />TN . <br />t.wG E N3F its ite i has been elcctronicadlc <br />si sued and waled bc_ Keith P. Shedd, <br />No 48014 P.F_ u,imL a Dwita l Siunature and <br />* : * date_ Printed copies of this dO Ctlment <br />are not considered signed and sealed <br />STATE OF <1/ and the signaun'e must be verified on <br />'. !(� : am' cicetrontc coptes <br />O R 1 D <br />06/13/2021 <br />1,,,,,,ONA� 1%%, <br /><� <br />Q� <br />WSTORY <br />_N0. <br />� <br />DATE <br />coat. � <br />rear <br />.,ettvL <br />raa.r <br />.Pravt. <br />NOfE3 <br />nnRtc <br />etcR <br />U <br />C <br />N cV <br />0 in <br />L <br />L- <br />O <br />U) L <br />C <br />O <br />U <br />vi <br />O <br />U <br />C <br />� <br />I � <br />O O <br />O <br />U N <br />O <br />m <br />CUSTOMER <br />PROJECT <br />0 <br />x F <br />r-1 •. i � <br />FW- <br />w <br />� Z <br />J <br />m <br />ENG BY: MNF <br />CAD BY: <br />WJD <br />DET BY: <br />WJD <br />CKD BY: <br />Tic <br />JOB NUMBER <br />B21-1794 <br />DWG NUMBER : B <br />CS2 of 2 <br />