<br />BUILDING SPECIFICATIONS
<br />The building system shown on these drawings has been designed and detailed for the loads and conditions
<br />stipulated by the letter of certification, and these drawings.
<br />Any alterations to this building system, removal of any of its components or parts, modification of the intended
<br />end —use, modifications in cladding or any other deviations from the original conditions for which the building
<br />system was designed may be done only with the written approval of a registered architect and/or a registered
<br />professional engineer, as applicable. The metal building manufacturer (MBM) will assume no responsibility for any
<br />of the changes mentioned above if performed without prior written approval by the MBM.
<br />This building system has been designed per the MBM's standard design and manufacturing practices, the governing
<br />building code, and the applicable editions of the building code referenced AISC, AISI, ASCE, and AWS standards.
<br />This building system has also been designed in accordance with all applicable provisions of the latest edition of
<br />MBMA Metal Building Systems Manual. In applications including structural steel deck and steel joists, the code
<br />referenced editions of applicable SDI and SJI standards, respectively, were also applied.
<br />The MBM does not design or check ventilation or energy conservation systems for the building system supplied and
<br />is not responsible for the adequacy of specified ventilation and energy conservation components. The End User
<br />should insure that adequate provisions are made for ventilation, condensation, and energy conservation requirements.
<br />The MBM is not responsible for the design, materials and workmanship of the foundation, or the anchorage of the
<br />building system to the foundation. Anchor bolt plans prepared by the MBM are intended to show only location,
<br />diameter, and projection of anchor bolts required to attach the metal building system to the foundation. The END
<br />USER is responsible for engaging the services of a licensed Professional Engineer to perform foundation and
<br />foundation anchorage design.
<br />The Professional Engineer designing the foundation shall determine the adequate anchor bolt material type and
<br />grade, anchor bolt embedment, and any anchorage reinforcement to accommodate the given anchor bolt locations,
<br />quantity, and diameter.
<br />Unless noted otherwise on the Letter of Certification, the building system by the MBM is exempt from the ASCE
<br />7 stipulated seismic drift limitations. The END USER shall insure that all the interior and exterior attachments
<br />and cladding by others are designed to accommodate seismic drift.
<br />The MBM does not investigate the influence of its metal building system on existing buildings or structures. The
<br />END USER shall engage services of a licensed Professional Engineer to evaluate whether such buildings and
<br />structures are adequate to resist snow drift loads or other conditions as a result of the presence of the Metal
<br />Building System. The materials used in fabrication of primary and secondary steel framing members, as well as
<br />related accessories are shown below with their corresponding ASTM designations. When the compliance with the
<br />building code mandated edition of the AISC Seismic Provisions is required, only materials approved by those
<br />provisions are used.
<br />Built—up Section Flanges (Fy = 55 ksi); A529, A572 or A588;
<br />Built—up Section Webs & Connection Plates (Fy = 55 ksi); A1011, A572 or A588;
<br />Hot —rolled W—shapes (Fy = 50 ksi); A992 or A572;
<br />Hot —rolled C and L—shapes (Fy = 50 ksi); A529 or A572;
<br />Hot —rolled Rods (Fy = 55 ksi); A108 or A572;
<br />Cold —formed C, Z, and ES shapes (Fy = 55 ksi); A1011 or A653;
<br />Panels, A792 or A653, Gr. 50 for Ga. 24 and thicker, Gr. 80 for others;
<br />HSS Round; A500 Gr. 8 (Fy = 42 ksi)
<br />HSS Square/Rectangular; A500 Gr. B (Fy = 46 ksi)
<br />Cables, A475
<br />Eyebolts (Gr. 55); A108, or A572
<br />Washers, A536
<br />Hillside Washers, A48
<br />Structural Bolts, A307 Gr. A, A325 Gr. C, A490 Gr. DH
<br />(used as noted in next section) .
<br />Unless noted otherwise and except for crane support system connections, all bolted joints shall be snug —tightened
<br />in accordance with the latest edition of Specification for Structural Joints Using ASTM A325, or A490 Bolts
<br />(RCSC). All joints in crane support system application shall be pretensioned as required by RCSC. All primary
<br />frame bolted connections use A325 bolts, unless noted otherwise. All end —plate connections in cold —formed steel
<br />frames use A325 bolts, unless noted otherwise.
<br />All primary structural members have been painted with the minimum of one coat of iron oxide inhibitive primer.
<br />All structural steel members have been painted in accordance with Steel Structures Painting Council Specification,
<br />SSPC No. 15.
<br />Shop and field inspections and associated fees and expenses are the responsibility of the contractor, unless noted
<br />otherwise.
<br />BUYER or CONTRACTOR RESPONSIBILITIES
<br />The BUYER or CONTRACTOR must secure all required approvals and permits for this project from the
<br />appropriate agencies in full compliance with all applicable local and state laws and regulations. In accordance with
<br />the Sec. 4.4.1 of the latest edition of the AISC Code of Standard Practice and the MBMA Common Industry
<br />Practices. Approval of these drawings and calculations (if applicable) constitutes an agreement that the MBM has
<br />correctly interpreted the requirements of the contract building drawings, specifications, and all other contractual
<br />requirements.
<br />In accordance with Sec. 3.3 of the latest edition of the AISC Code of Standard Practice, where discrepancies
<br />exist between drawings provided by the MBM and the drawings provided by the other trades, such as
<br />architectural, electrical, plumbing, and others, these drawings provided by the MBM shall govern.
<br />The BUYER or CONTRACTOR is responsible for the erection of the entire building system and all associated work
<br />pertaining thereto in accordance with the MBM's "For Construction" drawings. Drawings not marked "For
<br />Construction" SHALL NOT be used in the erection of the MBM's building system.
<br />In accordance with Sec. 7.10.3 of the latest edition of the AISC Code of Standard Practice, temporary supports
<br />such as guys, braces, falsework, shoring, and other elements necessary to safely erect the building system and
<br />prevent structural and other damage to the building system shall be determined and furnished by the erector.
<br />The structural building system provided by the MBM is designed for service conditions in accordance with the
<br />building code. The BUYER or CONTRACTOR shall erect the system in a manner that insures that the loading
<br />conditions on the structure during service are not exceeded in any part of the structure throughout the erection
<br />process.
<br />Unless noted otherwise, the MBM shall not be responsible for the design of any elements of this project not part
<br />of the structural building system provided by the MBM. The BUYER or CONTRACTOR shall be responsible for
<br />taking appropriate steps to insure that such elements are properly structurally designed and constructed.
<br />It is the responsibility of the BUYER or CONTRACTOR to observe and apply all pertinent OSHA and other
<br />mandatory safety provisions.
<br />The BUYER or CONTRACTOR is responsible for the inspection of all of the MBM's shipment when received. Any
<br />claims of non —received items must be reported to the MBM in writing within 5 business days. In order to
<br />maintain the quality guarantee and to qualify for reimbursement, any field modifications of any reported defective
<br />item may not be performed without a prior written endorsement by the MBM.
<br />THE MBM shall not be held liable for any claim whatsoever, including, but not limited to, labor charges or
<br />consequential damages, resulting from the BUYER or CONTRACTOR/Erectors use of defective or incorrect
<br />materials that can be detected by visual inspection.
<br />THE MBM is not responsible for material damaged in unloading or for packaged or nested materials, including, but
<br />not limited to, fasteners, sheet metal, "C" and "Z" sections, and covering panels that become wet and/or are
<br />damaged by water while in the possession of others. Packaged or nested materials that become wet in transit
<br />shall be unpacked, unstacked and dried by the BUYER or CONTRACTOR.
<br />With respect to all other building system erection aspects not mentioned above, the BUYER or CONTRACTOR shall
<br />comply with the Sec. 6 of the MBMA Common Industry Practices. For any aspects of the erection not covered by
<br />the MBMA Common Industry Practices, the provisions of Sec. 7 of the latest edition of the AISC Code of
<br />Standard Practice shall apply.
<br />ENGINEERING SEAL
<br />This certification covers parts
<br />fabricated and delivered by the
<br />manufacturer only and excludes
<br />parts such as doors, windows,
<br />foundation design, and erection of
<br />the building. Sealed drawings do
<br />not constitute an agreement that
<br />the signed engineer is acting as
<br />the engineer of record for the
<br />overall project.
<br />KEITH SHEDD
<br />459 WOODLAND RD
<br />BATESVILLE, MS. 38606
<br />PE# 48014
<br />`%��1uuuu,,
<br />,�
<br />TN .
<br />t.wG E N3F its ite i has been elcctronicadlc
<br />si sued and waled bc_ Keith P. Shedd,
<br />No 48014 P.F_ u,imL a Dwita l Siunature and
<br />* : * date_ Printed copies of this dO Ctlment
<br />are not considered signed and sealed
<br />STATE OF <1/ and the signaun'e must be verified on
<br />'. !(� : am' cicetrontc coptes
<br />O R 1 D
<br />06/13/2021
<br />1,,,,,,ONA� 1%%,
<br /><�
<br />Q�
<br />WSTORY
<br />_N0.
<br />�
<br />DATE
<br />coat. �
<br />rear
<br />.,ettvL
<br />raa.r
<br />.Pravt.
<br />NOfE3
<br />nnRtc
<br />etcR
<br />U
<br />C
<br />N cV
<br />0 in
<br />L
<br />L-
<br />O
<br />U) L
<br />C
<br />O
<br />U
<br />vi
<br />O
<br />U
<br />C
<br />�
<br />I �
<br />O O
<br />O
<br />U N
<br />O
<br />m
<br />CUSTOMER
<br />PROJECT
<br />0
<br />x F
<br />r-1 •. i �
<br />FW-
<br />w
<br />� Z
<br />J
<br />m
<br />ENG BY: MNF
<br />CAD BY:
<br />WJD
<br />DET BY:
<br />WJD
<br />CKD BY:
<br />Tic
<br />JOB NUMBER
<br />B21-1794
<br />DWG NUMBER : B
<br />CS2 of 2
<br />
|