a s <br />DATE <br />3/28/18 <br />No PAGE 11 <br />SCALE <br />MASONRY WALLS <br />*1 CONCRETE MASONRY UNITS SHALL BE HOLLOW UNIT <br />MASONRY IN ACCORDANCE WITH ASTM C-90 AND SHALL <br />HAVE MINIMUM F'M OF 1500 P,S,I, <br />*2 MORTAR SHALL CONFORM TO ASTMC -2-10 AND SHALL BE <br />EITHER TYPE M OR S, <br />*3 REINFORCING STEEL SHALL BE GAUGE 40 MINIMUM AND <br />IDENTIFIED IN ACCORANCE WITH ASTMA-615.LAP SPLICES <br />WHERE REQUIRED SHALL BE A MINIMUM OF 25" FOR *5 REBAR <br />30" FOR *6 REBAR AND 36" FOR *'l REBAR. <br />*4 GROUT FOR POURED CELLS AND LINTELS SHALL HAVE A <br />MAXIMUM COURSE AGGREGATE SIZE OF 3/8" PLACED AT 8 TO <br />11 INCH SLUMP AND HAVE A MINIMUM 28 DAY COMPRESSIVE <br />STRENGTH OF 3000 P,S.I, ( WHEN TESTED PER ASTM C-1019) <br />*5 PROVIDE CLEAN OUT OPENINGS (12 SQ IN,) IN CELLS <br />CONTAINING SPLICED REINFORCEMENT. WHEN THE GROUT <br />POUR EXCEEDS 5 FEET IN HEIGHT, <br />FINISHED GRADE <br />8"x24" COMPOSITE PRECAST LINTEL <br />TOP COURSE LINTEL BLOCK <br />POURED SOLID WITH 3000 PSI CONCRETE <br />WITH (1) •5 CONT. REBAR <br />PRE -CAST U-LINTELS <br />POURED SOLID WITH 3000 PSI <br />CONCRETE (U 05 REBAR REQUIRED <br />a <br />�- ALL MASONRY OPENINGS <br />ON THIS JOB <br />8"44" COMPOSITE <br />POWER BOX STEEL LINTEL <br />TOP COURSE LINTEL BLOCK <br />POURED SOLID WITH 3000 PSI CONCRETE <br />WITH (1) 05 CONT. REBAR <br />POWER BOX STEEL LINTEL <br />POURED SOLID WITH 3000 PSI <br />�NCRETE (U "5 REBAR REQUIRED <br />— ALL MASONRY OPENINGS <br />ON THIS JOB <br />GALV-ALUM METAL ROOFING <br />OVER AN APPROVE SELF ADHESIVE <br />ROOFING UNDERLAYMENT <br />12 <br />10 <br />FRAME THE 2x6 GABLE WALL WITH THE <br />TRIPLE 2x12 RIDGE BEAM STUDS STARTED WITH AN ODD SPACE <br />AND 2x8 RAFTERS 16" OC, TO NOT INTERFERE WITH THE SPACING <br />CONVENTIONAL FRAMED OF THE GREAT ROOM ROOF TRUSSES,, ATTIC <br />SPACE <br />--- - - ---- ---- ---- ---- ---- - <br />------ ------ ------ <br />2x6 GABLE WALL WITH STUDS iro OC, <br />VALLEY TRUSSES 24" OC, PRE-ENG. WOOD TRUSSES <br />24" OC SPACING <br />a <br />a <br />12 <br />JAMES HARDI SIDING <br />Sx8 POSTS OVER THE <br />MASONRY WALLS <br />THE FOOTERS FOR THE FRONT PORCH FOUNDATION <br />WILL BE A CONTINUOUS 8"x 16" 3000 PSI FOOTER WITH (2) *5 <br />HORIZONTAL REBARS ON ROD CHAIRS SPACED NO MORE THAN <br />48" OC, THE RODS WILL BE TIED TO THE CHAIRS. THE MIN LAP <br />FOR 18 25" AND ALL LAPS WILL BE TIED, <br />1/2" CEILING DRYWALL ON <br />ALL INTERIOR CEILINGS <br />8"x24" COMPOSITE <br />POWER STEEL LINTEL <br />TOP COURSE LINTEL BLOCK <br />POURED SOLID WITH 3000 PSI CONCRETE <br />WITH (1) *5 CONT. REBAR <br />POWER STEEL LINTEL AND LINTEL BLOCK <br />POURED SOLID WITH 3000 PSI <br />CONCRETE (U *5 REBAR REQUIRED <br />I <br />�— ALL MASONRY OPENINGS <br />ON THIS JOB <br />RECESS DOOR HEADER <br />LABEL <br />CLEAR SPAN <br />TOTAL LENGTH <br />DOOR SIZE <br />p-1 <br />2'-411 <br />3'—Q 11 <br />2'-011 <br />D-2 <br />2'-8" <br />4'-0" <br />2'-4" <br />D-3 <br />2'-10" <br />4'-2" <br />2'-6" <br />D-4 <br />3'-0 if <br />4'-4„ <br />2'-8" <br />D-5 <br />3'-4" <br />4'-8" <br />3'-0" <br />D-ro <br />4'-4" <br />5 -8" <br />4'-0" <br />D-1 <br />5'-4 ' <br />6'-8" <br />5'-0" <br />D-8 <br />6'-4" <br />1'-8" <br />6'-0" <br />D-9 <br />8'-4" <br />9'-8" <br />8'-O" <br />MAX, 1516 PLF ON MAX SPAN (1) *5 TOP COURSE ONLY <br />THE ROOF SHEATHING WILL BE 1/2" CDX OR OSB NAILED TO <br />THE ROOF TRUSSES WITH 8d GALV, COMMONS AT 6" OC IN <br />ALL AREAS. USE 1/2" PLYWOOD CLIPS BETWEEN THE SHEETS <br />AND BLOCKING WHERE PLYCLIPS WONT WORK. <br />DESIGN SERVICES INC. <br />MOBILE/ OFFICE 352-206-5821 <br />R. S, HANLEY P O BOX 1325 SAN ANTONIO <br />FLA. 3351ro <br />FEMAIL: Han Isy06-membarclmaII,com <br />CUSTOM HOMES AND BARNS <br />ALL TEMPORARY AND PERMANENT BRACING INFORMATION <br />FOR THE ENGINEERED ROOF TRUSSES WILL BE FURNISHED BY <br />THE TRUSS COMPANY THAT PRODUCES THE TRUSSES, <br />VERT WEBS ARE REQUIRED AT THE GABLE BRACING LOCATIONS <br />ICYNENE INSULATION <br />ATTIC <br />VALLEY TRUSSES 24" OC, PRE ENGINEERED ROOF TRUSSES 24" OC. ICYNENE INSULATION WILL BE USED AS THE ATTIC <br />------ ---------- ---- <br />SPACE l r AND WALL INSULATION. ICYNENE REQUIRES THAT <br />THE ATTIC WILL NOT HAVE VENTILATION THRU THE <br />SOFFITT OR THE RIDGE. THE HOUSE WILL HAVE TO <br />11 If 11 HAVE A FRESH AIR INTAKE VENT, WITH A DAMPER <br />PRE-ENG, WOOD TRUSSES AS PER THE MECHANICAL CONTRACTOR. <br />24" OC SPACING <br />a <br />12 <br />a <br />a <br />i <br />a <br />a <br />a <br />------------------------ - <br />- <br />- <br />- <br />- <br />- ---- <br />LOFT 2x8 RAFTERS AND HEADERS SIMPSON HURRICANE TIES <br />COLLAR TIES 24" OC, SEE THE TRUSS LAYOUT PAGE <br />OF THIS PLAN FOR CONNECTIONS <br />THE MAIN HOUSE CEILING VARIES. 6x6 *2 PT POSTS <br />SEE THE MAIN FLOOR PLAN, <br />RAILING OR KNEEWALL <br />OF THE LOFT <br />2X4 AND 2x6 *2 SPRUCE STUDS AT 16" OC <br />WITH A DBL TOP PLATE ON ALL BEARING WALLS, <br />1/2" THREADED RODS FOR UPLIFT CONNECTIONS <br />SEE THE TRUSS LAYOUT FOR THE APPROX LOCATIONS <br />AC CHASE FLAT IRDER <br />POURED 10'-0" TOP COURSE LINTEL BLOCKS WITH <br />(1) *5 ROD TIED TO THE VERT RODS IN THE <br />FILLED CELLS, <br />POURED LINTELS AT 8'-0" OVER SOME OF THE WINDOW <br />AND DOOR OPENINGS WITH (1) *5 REBAR TIED <br />TO THE VERT FILLED CELL REBARS, <br />1/2" DRYWALL OVER IX FURRING STRIPS <br />AND RIGID INSULATION R-5, DBL FURRING <br />OR 2x AT THE TOP FOR DRAFTSTOPPING <br />12" <br />24" <br />CLEAN, TREATED, COMPACT SOIL <br />THE BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS. ANY ADDITIONAL FILL <br />- PLACED ON THE BUILDING PAD AREA SHALL BE COMPACTED SUCH THAT IT CAN ADEQUATELY <br />SUPPORT A 2000 P.S.F. FOUNDATION LOADING. THE SLAB SHALL BE PLACED OVER A 6MIL VAPOR <br />BARRIER ON CLEAN ADEQUATELY COMPACTED AND TERMITE POISONED SOIL, THE CONCRETE UTILIZED <br />IN THE FOUNDATION AND SLABS SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 P,S,I, <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE WITH ASTM A -615, <br />LAP SPLICES, WHERE REQUIRED SHALL BE A MINIMUM OF 25" FOR *5 REBAR. <br />ALL FLOOR TRUSSES WILL BE INSET <br />FROM THE OUTSIDE WALLS 1/2" FOR <br />THE SUB LAYER OF WALL SHEATHING, <br />2 x 6 *2 PT PLATE ATTACHED <br />TO THE TOP OF THE MASONRY WALLS <br />WITH 1/2" x 8" J-BOLTS AT 32" OC, BESIDE <br />ALL OPENINGS, SPLICES AND 12" IN BOTH <br />DIRECTIONS FROM THE CORNERS. <br />FINISHED FLOORING <br />-------------------- <br />12" <br />24" <br />THE BOTTOM ON THE FOOTER <br />WILL BE A MIN OF 12" INTO THE <br />EXISTING UNDISTURBED GROUND <br />A 4" / 3000 PSI CONCRETE SLAB OVER 6x6 10/10 WIRE <br />MESH AND A 6 MIL.VISQUEEN VAPOR BARRIER WILL BE <br />POURED FOR THIS HOUSE. THE SOIL WILL BE TREATED FOR <br />TERMITES AND BE CLEAN AND COMPACTED. F15ERMESH <br />CONCRETE MAY BE USED WITH WIRE MESH. <br />SECOND STORY HANDRAIL <br />ATTIC METAL OR ALUM. <br />SPACE DRIP EAVE 0,024 MIN, <br />PRE FINISHED FASCIA <br />OVER 2X SUB -FASCIA <br />NON- VENTED SOFFITT <br />6x6 POSTS <br />8" CONCRETE BLOCK <br />EXTERIOR WALLS <br />• c , , POST BASE <br />JAMES HARDI PLANK LAPPED SIDING <br />1/2" (32/24) CDX OR OSB SHEATHING <br />NAILED FROM THE BOTTOM PLATE ON <br />THE CONCRETE SLAB TO THE TOP OF <br />THE FRAME WALL, <br />NAIL THE SIDE EDGES 6" OC <br />NAIL THE INTERIOR 12"OC <br />NAIL THE END EDGES 3" OC <br />KEEP THE SHEATHING OFF THE MASONRY, <br />2x12 *2 PT SOUTHERN YELLOW PINE FLOOR <br />JOISTS 16" OC WITH 3/4" PT DECKING. <br />SLOPE THE PORCH AWAY FROM THE <br />MAIN HOUSE AND USE DECKRITE WATER <br />PROOFING SYSTEM FOR THE PORCH <br />FLOOR OR SOMETHING EQUAL, <br />ALL CONNECTIONS TO THE PRESSSURE <br />TREATED WOOD WILL BE HOT -DIPPED <br />ZINC COATED GALVANIZED STEEL. <br />*5 REBAR IN FILLED CELLS IN THE <br />STEMWALL OF THE FOUNDATION. SEE <br />THE FOUNDATION PAGE FOR THE <br />LOCATION OF THE CELLS. <br />12" �-� � 12" <br />24" 24" <br />THE FOOTERS FOR THE MAIN HOUSE AND REAR PORCH <br />FOUNDATION WILL BE A CONTINUOUS 1211x 24" 3000 PSI <br />FOOTER WITH (3) *5 HORIZONTAL REBARS ON ROD CHAIRS <br />SPACED NO MORE THAN 48" OC.THE RODS WILL BE TIED <br />TO THE CHAIRS, THE MIN LAP FOR 18 25" AND ALL LAPS <br />WILL BE TIED, <br />TREATMENT: ( SOIL CHEMICAL 5ARRIER METHOD) <br />SOIL 5EARING CAPACITY <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE <br />SOIL BEARING CAPACITY OF 2000 P.S.F.(MINIMUM) THE <br />CONTRACTOR / PROPERTY OWNER IS RESPONSIBLE FOR <br />VEIFYING THAT THE SOIL ON THE SITE IS PROPERLY <br />PREPARED AND COMPACTED SUCH THAT IT CAN SUPPORT <br />A 2000 P.S.F, FOUNDATION LOADING. <br />1) <br />A PERMANENT SIGN TO IDENTIFY THE TERMITE TREATMENT PROVIDER AND <br />(3) <br />CONCRETE OVER POUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE <br />NEED FOR RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED, <br />REMOVED BEFORE EXTERIOR SOIL TREATMENT <br />THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL <br />10) <br />SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITH 1'-0" <br />2) <br />CONDENSATE AND ROOF DOWN SPOUTS SHALL DISCHARGE AT LEAST 1'-0" AWAY FROM <br />OF THE STRUCTURES SIDEWALLS. <br />THE BUILDING SIDEWALLS <br />11) <br />AN EXTERIOR VERTICAL CHEMICAL BARRIERS MUST BE INSTALLED AFTER <br />3) <br />IRRIGATION SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS SHALL <br />CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. <br />NOT BE INSTALLED WITHIN 1'-0" OF THE BUILDINGS SIDEWALLS <br />ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED, SHALL BE <br />4) <br />TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION BETWEEN WALL COVERING <br />RETREATED. <br />AND FINAL EARTH GRADE SHALL NOT BE LESS THA 6 INCHES ( EXCEPTION PAINT OR <br />12) <br />ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT <br />DECORATIVE CEMENTIOUS FINISH LE65 THAN 5/5" THICK ADHERED DIRECTLY TO THE <br />13) <br />A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY <br />FOUNDATION WALL.) <br />A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL <br />5) <br />INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACK FILL IS COMPLETED. <br />BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: " THE BUILDING HAS <br />6) <br />SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED INCLUDING SPACES BOXED <br />RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. <br />OR FORMED. <br />THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE <br />FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. <br />_11) <br />BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLLATION OF TRAPS, ETC. SHALL BE <br />14) <br />AFTER ALL WORK IS COMPLETE LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />MADE WITH PERMANENT METAL OR PLASTID FORMS, PERMANENT FORMS MUST BE OF A SIZE AND <br />BELOW AND WITHIN i'-O" OF THE BUILDING, THIS INCLUDES ALL GRADE STAKES,TUB <br />DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL AFTER THE INITIAL TREATMENT , <br />TRAP BOXES, FORMS,SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. <br />8) <br />A MINIMUM ro MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST <br />15) <br />NO WOOD , VEGETATION, STUMPS, CARDBOARD ,TRASH ETC. , SHALL BE BURIED WITHIN <br />RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, <br />e'-O" OF ANY BUILDING OR PROPOSED BUILDING <br />RE -TREATMENT IS REQUIRED, <br />FINISHED GRADE <br />0111,91111 <br />�� 1 pA, <br />eepsauseps <br />`��, P� E ,•eee <br />C .� 00 <br />• <br />No. 5350i3 <br />oa,. a "�' • ,� <br />70 p e TAT5Al <br />• <br />i • <br />a•' � • e•ir ,4 <br />Oily <br />JOB NAME and ADDRESS <br />JAMIE R CREWS <br />40134 CHANCEY ROAD <br />ZEP- YRHILLS, FLORIDA <br />33540 <br />MAIN FLOOR LIVING AREA <br />1644 <br />SF <br />SECOND FLOOR LIVING AREA <br />1060 <br />SF <br />FRONT PORCH <br />251 <br />SF <br />REAR PORCH <br />504 <br />SF <br />SECOND STORY PORCH <br />292 <br />SF <br />OUTSIDE CLOSET <br />50 <br />SF <br />TOTAL UNDER ROOF <br />3501 <br />SF <br />DAV ID W. SMITH, MS, PE, <br />FLORIDA LIC.* 536 08 <br />352-521-0865 OFFICE 352-521-08rol FAX, <br />9909 WALLASTON DRIVE DADE CITY ,FLA, 33525 <br />1 HEREBY CERTIFY THAT I HAVE REVIEWED THIS <br />PLAN AND FOUND IT TO BE IN COMPLIANCE WITH <br />ASCE -1-10 AND THE 2011 FLORIDA BUILDING COD <br />6th EDITION, >> <br />DAVID W. SMITH, MS. PE, LIC.* 53608 <br />