My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
40134 Chancey Rd
Zephyrhills
>
Building Department
>
Building Plans
>
40134 Chancey Rd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:25:52 AM
Creation date
2/19/2025 11:35:09 AM
Metadata
Fields
Template:
Building Plans
Street #
40134
Location
Chancey Rd
Contractor
Pete Richter Construction
Building Plans - Permit #
20277
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DATE SCALE: <br />1 /4 1= 1-011 PAGE <br />i <br />L — — — — J <br />L <br />2 -8' I{/ <br />OUTSIDE I <br />CLOSET <br />CEILING / <br />CENTRAL . - - - - - - <br />VACUUM I <br />SYSTEM I <br />AHU <br />I I I <br />REAR PORCH <br />\ l IfJ LfJ <br />ppII---------- <br />IT\ <br />SX4X4 j ELEttTR � <br />�fCXTOx6 <br />- - - - - - - - - I I EL crRIC1f DRYER WATER TIEATE <br />`\ IOOCFM <br />WALK-IN <br />CLOSET *3 r' , _ I p� ® 30" ELECTRIC RANGE <br />ELECTRIC WASHER\ Q I 12xbx1Lu <br />` <br />I i Q q 1 / <br />l0'-1 v2 <br />, \ <br />X <br />CEILING <br />\ <br />�1� <br />N I ram' I1 <br />LAUNDRY TUB l <br />I <br />i Lu Lu <br />? <br />ELEC. ,' <br />PANEL; <br />i 1 <br />111 O <br />i a <br />. <br />i l <br />IIN <br />® <br />Q <br />MUD ROOM <br />I <br />1u a <br />/ <br />CV <br />loxlox6 <br />i' ` <br />,' - <br />m <br />' <br />10'-1 1/2" CEILING <br />,1 <br />2 -8 <br />1oocFM I KITCHEN <br />BATHROOM > <br />\ 10'-1 1/2" CEILING <br />I� <br />I - <br />3 LL <br />LL <br />2 X <br />\ <br />10'-I 1/2" CEILING ,' <br />i i t 01 <br />\ '\ <br />6 <br />®X <br />r- <br />_ <br />mano - <br />---------------LINE <br />OF LOFT A50VE <br />--------------------------- <br />_ <br />\ / <br />I <br />HALF .� 1 <br />`\ ® <br />2-811 <br />® <br />0 <br />:IQ,� <br />BATH I <br />---------- <br />1 n " I ♦ <br />LJ <br />10'-1 1/2" CEILING <br />\ <br />\ <br />_ _ _ _ _ _ _ _ _ _ <br />\ <br />\ <br />12x6x1 <br />150GFM <br />12x6x1 <br />150CFM <br />------------ <br />) FBI <br />x0 I / \ <br />� !n <br />dw <br />SOFFITT <br />OUTLETS <br />/---------- \\ FLOOR OUTLET ' ---------- \ <br />r <br />a \\ <br />II ---------- I <br />I I ---------- yj FAMILY ROOM ' <br />BEDROOM #2 - - - - - - - - - - FLOOR OUTLET VAULTED CEILING ' <br />10'-1 1/2" CEILING <br />12x6x1 / <br />150CFM <br />SWITCH FOR SOFFITT OUTLETS <br />SOFFITT <br />OUTLETS <br />I \ <br />/ <br />FRONT PORCH <br />INT <br />ERIOR RIDGE <br />I I <br />I I � <br />I � I <br />I I I <br />I � � <br />1 <br />I 1 � <br />----------------------- -®-- - -------------- <br />RAILING POST <br />AC REQUIRED <br />4 1/2 TONS 54000 BTUS 1800 CFM <br />1) THE DUCT WORK, ALL FLEX RUNS AND DUCT <br />RUNS COULD CHANGE DUE TO THE FRAMING OF <br />THE HOUSE AND THE ROOF TRUSSES WEB DESIGNS. <br />THE DUCTS ARE NOT SHOWN FOR THIS REASON. <br />2) THE FIRST NUMBERS BY THE GRILL <br />ARE THE SIZE OF THE VENT AND THE <br />LAST NUMBER BY THE GRILL IS THE DUCT SIZE. <br />3) IN ORDER FOR THE AC SYSTEM TO WORK <br />EFFICIENTLY THE CONTRACTOR WILL NEED TO <br />HAVE 6"x12" PASS THROUGH VENTS ABOVE ALL <br />DOORS OR INSTALL INDIVIDUAL RETURNS IN <br />EACH ROOM. <br />4) ONLY HEATING IS REQUIRED <br />5) THE HVAC CONTRACTOR WILL DETERMINE IF ONE <br />UNIT OR TWO WILL BE REQUIRED AFTER THE HOUSE <br />IS FRAMED. THERE ARE 2 LOCATIONS PROVIDED FOR <br />THE AHU, <br />-®-- ------------------------- <br />RAILING POST <br />MAIN ELECTRICAL PLAN <br />J <br />SOFFITT <br />OUTLETS <br />ATTIC SPACE <br />STORAGE <br />SECOND STORY PORCH <br />9'4' CEILING <br />VAULTED CEILING I , <br />--- <br />CEILING HEIGHT , 51�11 <br />I I <br />\ I IIMM <br />F <br />lOxlOx6 12x6x1 <br />12x6x1 <br />IOOCFM \ 150GFM <br />12x6x1 <br />\ - - -� <br />150GFM <br />V <br />/DINING ROOM <br />I10'-1 1/2" CEILING <br />3'46" x 4'-21,2" <br />SW 24 <br />bw <br />SOFFITT <br />OUTLETS <br />DESIGN SERVICES INC. <br />MOBILE/ OFFICE 352-206-5&21 <br />R. S. HANLEY P o BOX 1325 SAN ANTONIO <br />FLA. 33516 <br />EMAIL: haniey06lvembargmail.com <br />CUSTOM HOMES AND BARNS <br />ATTIC SPACE <br />-------------------------------- <br />VAULTED CEILING <br />-------------------- <br />WALK-IN CLOSET <br />1 rl <br />9'-O" CEILING <br />12x6x1 <br />150CFM 1 <br />/ N <br />1 <br />'---------- <br />I/ VAULTED CEILING <br />- I --'- - - - -- <br />--------------------- <br />LOFT b <br />---------------------I <br />V-411 <br />MASTER BEDROOM \ <br />r' I t I i i / CATHEDRAL CEILING / - <br />I I <br />SITTING AREA \ I <br />I \ <br />lo'-o" CEILING <br />VAULTED CEILING <br />STORAGE <br />r <br />CJ <br />`-/ <br />U� <br />2-X-�y <br />-� <br />LL I1Oxlox6 <br />OOC� <br />4260MASTER —K'- <br />Cr <br />VAUL <br />CEIl_- <br />ro <br />N <br />2'-6" <br />I <br />I <br />---`\ <br />I <br />i <br />WALK-IN ' <br />I <br />- - - - - - <br />\MASTER <br />-- ----- -- <br />CLOSET ' <br />I <br />} ' <br />T I <br />I <br />--------- <br />8x4x4 <br />-- <br />50CFM ' <br />------ <br />9'-O" CEILING <br />- - - - - - - <br />- <br />---------- <br />T- <br />VAULTED ; <br />- <br />CEILING <br />--------- <br />---------- <br />CATHEDRAL CEILING <br />RAILING <br />OPEN TO BELOW <br />FAMILY ROOM <br />VAULTED CEILING <br />ll ATTIC ACCESS <br />I <br />----------- <br />----------- <br />ALL ATTIC SPACES REQUIRE ACCESS - <br />WITH A LIGHT, ATTIC SPACE <br />AHU <br />I I I <br />------------------------------------------------------------------- <br />I I I <br />(_ <br />ELECTRICAL <br />COUNT <br />SYMBOL <br />CEILING FANS AND LIGHTS <br />12 <br />6 IN CAN LIGHTS <br />38 <br />EXTERIOR WALL LIGHTS <br />6 <br />HALF BATH WALL LIGHT <br />1 <br />CABLE <br />5 <br />RG6 <br />CARBON MONOXIDE DETECTORS <br />2 <br />EXFAN <br />4 <br />FLOOROUTLET <br />2 <br />FLOOR OUTLET <br />SOFFITT OUTLETS <br />4 <br />&A <br />SOFFITT <br />OUTLETS <br />CEILING LIGHTS <br />16 <br />r�} <br />110 WALL OUTLETS <br />49 <br />220 WALL OUTLETS <br />Z <br />GFI OUTLETS <br />28 <br />6GR <br />SMOKE DETECTORS <br />I <br />SINGLE SWITCHES <br />54 <br />3 WAY SWITCHES <br />24 <br />$s <br />VANITY LIGHT BARS <br />4 <br />0 0 0 <br />1 I I <br />I I I <br />I I I <br />I I I <br />I I 1 <br />I I I <br />FRONT PORCH ROOF BELOW <br />I I I <br />I I I <br />I I I <br />I I I <br />I I 1 <br />I I 1 <br />1 I 1 <br />I I I <br />I I 1 <br />I I I <br />I I I <br />I I I <br />I I I <br />I , , <br />I I 1 <br />I <br />I I I <br />'------' <br />SECOND STORY ELECTRICAL PLAN <br />ELECTRICAL ICAL NOTES <br />1) ELECTRICAL, PLUMBING, AND MECHANICAL SYSTEMS SHALL <br />BE DESIGNED BY THE RESPECTIVE CONTRACTORS TO MEET <br />ALL APPLICABLE CODES, THE SYSTEMS DRAWN HEREON ARE <br />BASED UPON THE HOMEOWNERS REQUIREMENTS. <br />2) ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHENS, <br />EXTERIOR AREAS, ABOVE COUNTER HEIGHTS AND WITHIN <br />6'-O" OF SINKS SHALL BE GFI <br />GROUND FAULT INTERRUPTER) <br />3) ALL ELECTRICAL OUTLETS IN BEDROOMS SHALL BE WIRED INTO <br />AN ARC -FAULT INTERRUPTER "AR" CIRCUIT. <br />4) SMOKE DETECTORS SHALL BE PLACED IN EACH BEDROOM <br />AND IN HALLWAY AREAS ADJACENT TO BEDROOM AND OTHER <br />LIVING AREAS . THE DETECTORS MUST BE HARDWIRED AND ALL <br />DETECTORS ARE REQUIRED TO ALARM ONCE ONE HAS DETECTED <br />SMOKE IN ANY SECTION OF THE RESIDENCE. <br />5) PROVIDE AN OUTLET AND LIGHT WITHIN REACH OF EVERY <br />ATTIC ACCESS AREA FOR ANY FUTURE SERVICE IN <br />THE ATTIC AREA. <br />6) PROVIDE CARBON MONOXIDE DETECTORS WITHIN 10',I9T �4 <br />OF ALL BEDROOMS. �," \ ee.. ee s, <br />® A No.535o <br />» <br />e <br />e <br />� <br />STORAGE <br />JOB NAME and ADDRESS <br />JAMIE R CREWS <br />40134 CHANCEY ROAD <br />ZEPHYRHILLS, FLORIDA <br />33540 <br />MAIN FLOOR LIVING ,AREA 1644 SF <br />SECOND FLOOR LIVING AREA 1060 SF <br />FRONT PORCH 251 SF <br />REAR PORCH 504 SF <br />SECOND STORY PORCH 292 SF <br />OUTSIDE CLOSET 50 SF <br />TOTAL UNDER ROOF 3801 SF <br />DAV ID W. SMITH, MS, PE, <br />FLORIDA LIC.* 53608 <br />352-521-0865 OFFICE 352-521-05r'ol FAX, <br />9909 WALLASTON DRIVE DADE CITY ,FLA. 33525 <br />1 HEREBY CERTIFY THAT I HAVE REVIEWED THIS <br />PLAN AND FOUND IT TO BE IN COMPLIANCE WITH <br />ASCE 1-10 AND THE 201-7 FLORIDA BUILDING CODE <br />6th EDITION. <br />DAVID W. SMITH, MS. PE. LIC,* 53608 <br />
The URL can be used to link to this page
Your browser does not support the video tag.