Laserfiche WebLink
PIPING LINE CALLOUTS <br />DESIGNATION DESCRIPTION <br />ACID <br />ACID <br />ALC <br />ALCOHOL <br />AR <br />ARGON <br />AV <br />ACID VENT <br />AW <br />ACID WASTE <br />AWFI <br />AMBIENT WATER FOR INJECTION <br />B <br />BRINE <br />BBD <br />BOILER BLOW DOWN <br />BFW <br />BOILER FEED WATER <br />BV <br />BIOVENT <br />BW <br />BIOLOGICAL WASTE <br />BWV <br />BIOLOGICAL WASTE VENT <br />CA <br />COMPRESSED AIR <br />CAUS <br />CAUSTIC <br />CCA <br />CLEAN COMPRESSED AIR <br />CD <br />CONDENSATE DRAIN <br />CGR <br />CHILLED GLYCOL RETURN <br />CGS <br />CHILLED GLYCOL SUPPLY <br />CHF <br />CHEMICAL FEED <br />CHWR <br />CHILLED WATER RETURN <br />CHWS <br />CHILLED WATER SUPPLY <br />CIPA <br />CIP ACID <br />CIPB <br />CIP BASE <br />CIPR <br />CLEAN IN PLACE RETURN <br />CIPS <br />CLEAN IN PLACE SUPPLY <br />CO <br />CARBON MONOXIDE <br />CO2 <br />CARBON DIOXIDE <br />CS <br />CLEAN STEAM <br />CWFI <br />COLD WATER FOR INJECTION <br />CWR <br />COOLING WATER RETURN <br />CWS <br />COOLING WATER SUPPLY <br />DCW <br />DOMESTIC COLD WATER <br />DHW <br />DOMESTIC HOT WATER <br />DHWR <br />DOMESTIC HOT WATER RETURN <br />DI <br />DEIONIZED WATER <br />EG <br />ETHYLENE GLYCOL <br />ETCH <br />ETHANOL <br />FOR <br />FUEL OIL RETURN <br />FOS <br />FUEL OIL SUPPLY <br />FOV <br />FUEL OIL VENT <br />FP <br />FIRE PROTECTION <br />FPBS <br />FIRE PROTECTION BLACK STEEL <br />FPGS <br />FIRE PROTECTION GALVANIZED STEEL <br />FPSS <br />FIRE PROTECTION STAINLESS STEEL <br />GLC GLUCOSE <br />H2 <br />HYDROGEN <br />HE <br />HELIUM <br />HHWR <br />HEATING HOT WATER RETURN <br />HHWS <br />HEATING HOT WATER SUPPLY <br />HPC <br />HIGH PRESSURE PLANT STEAM CONDENSATE <br />HPS <br />HIGH PRESSURE PLANT STEAM <br />HS <br />HUMIDIFICATION STEAM <br />HWFI <br />HOT WATER FOR INJECTION <br />IA <br />INSTRUMENT AIR <br />ICW <br />INDUSTRIAL COLD WATER <br />IHW <br />INDUSTRIAL HOT WATER <br />IHWR <br />INDUSTRIAL HOT WATER RETURN <br />IPA <br />ISOPROPYL ALCOHOL <br />IV <br />INDUSTRIAL VENT <br />IW <br />INDUSTRIAL WASTE <br />DESIGNATION DESCRIPTION <br />LCO2 <br />LIQUID CARBON DIOXIDE <br />LCW <br />LAB COLD WATER <br />LHW <br />LAB HOT WATER <br />LHWR <br />LAB HOT WATER RETURN <br />LN2 <br />LIQUID NITROGEN <br />LPC <br />LOW PRESSURE PLANT STEAM CONDENSATE <br />LPG <br />LIQUIFIED PETROLEUM GAS <br />LPS <br />LOW PRESSURE PLANT STEAM <br />LW <br />LAB WASTE <br />LWV <br />LAB WASTE VENT <br />MPC <br />MEDIUM PRESSURE PLANT STEAM CONDENSATE <br />MPS <br />MEDIUM PRESSURE PLANT STEAM <br />N2 <br />NITROGEN <br />N20 <br />NITROUS OXIDE <br />NG <br />NATURAL GAS <br />NPCW <br />NON -POTABLE COLD WATER <br />NPHW <br />NON -POTABLE HOT WATER <br />02 <br />OXYGEN <br />OSW <br />OVERFLOW STORM WATER <br />P <br />PROCESS <br />PC <br />PUMPED CONDENSATE <br />PCHR <br />PROCESS CHILLED WATER RETURN <br />PCHS <br />PROCESS CHILLED WATER SUPPLY <br />PTWR <br />PROCESS TEMPERED WATER RETURN <br />PTWS <br />PROCESS TEMPERED WATER SUPPLY <br />PUR <br />PURIFIED WATER <br />PV <br />PROCESS VENT <br />PW <br />PROCESS WASTE <br />PWV <br />PROCESS WASTE VENT <br />RG <br />REFRIGERANT HOT GAS <br />RL <br />REFRIGERANT LIQUID <br />RO <br />REVERSE OSMOSIS <br />IRS <br />REFRIGERANT SUCTION <br />RV <br />RELIEF VENT <br />SAN <br />SANITARY WASTE <br />SFT <br />SOFT WATER <br />SV <br />SANITARY VENT <br />SW <br />STORM WATER <br />TEWR <br />TEPID WATER RETURN <br />TEWS <br />TEPID WATER SUPPLY <br />TSWR <br />THERMAL STORAGE WATER RETURN <br />TSWS <br />THERMAL STORAGE WATER SUPPLY <br />TWR <br />TOWER WATER RETURN <br />TWS <br />TOWER WATER SUPPLY <br />USP USP PURIFIED WATER <br />VAC VACUUM <br />VW VIRAL WASTE <br />VWV VIRAL WASTE VENT <br />WFI WATER FOR INJECTION <br />PIPING SYMBOLS PIPING CALLOUTS DUCTWORK SYMBOLS DUCTWORK CALLOUTS GENERAL <br />- — — — = PIPING TO BE REMOVED SIZE DUCTWORK TO BE REMOVED SIZE (RECTANGULAR DUCT) COLUMN LINE REFERENCE DRAWING REVISION <br />SERVICE SERVICE 1 REVISION NUMBER, SEE <br />PIPING TO REMAIN <br />SPEC 1 DESCRIPTION IN TITLE <br />NEW PIPING <br />DUCTWORK TO REMAIN 12"x12" XX BLOCK SAME SHEET <br />LINE NUMBER - <br />FLANGED CONN.IBLIND FLANGE INSULATION SIZE (ROUND DUCT) REVISION AREA <br />C NEW DUCTWORK A — -- — — <br />SERVICE i <br />PIPE CAP <br />2"-XXX-YYYY-ZZZZ-X DIMENSIONS <br />DUCTWORK WITH INSULATION 12"0 XX (+/-) DIMENSIONS ARE FOR <br />REDUCER INV. EL. = 10' - 61/8" BUILDING SECTION REFERENCE REFERENCE ONLY. CONTRACTOR <br />PIPE DROP/PIPE RISE — — SIZE (OVAL DUCT) SECTION NUMBER _ _ SHALL FIELD VERIFY AND NOTIFY <br />BOP = 10' - 6" DUCTWORK WITH LINING +/- X' - X" ARCHITECT/ENGINEER OF ANY <br />BOTTOM OUTLET TEE INV. EL. = 10' - 61/8" <br />SERVICE DISCREPANCIES <br /># +/- X' - X" X' X"� SET DIMENSIONS <br />L—A( <br />TOP OUTLET TEE <br />DUCT DOWN (SEE TAG FOR SYSTEM) Ei <br />2"/10" XX X00-00 SHEET WHERE SECTION (NON +/- DIMENSIONS) <br />BOP =10' - 6" IS DRAWNSAME DISCIPLINE — <br />, = <br />O STEAM TRAP ASSEMBLY WITH NUMBER Slope DIRECTION OF DOWNWARD SLOPE SUPPLY DUCT UP BOD 10' - 6" WALL SECTION REFERENCE <br />## (OPTIONAL) (S DENOTES SANITARY) <br />S SECTION NUMBER ROOM I SPACE NAME <br />RETURN DUCT UP FBOD =10' - 6" # XXX WALL SECTION REFERENCE TYPE ROOM NAME ROOM NAME <br />(WHERE APPLICABLE) <br />X00-00 101 ROOM NUMBER <br />SHEET WHERE SECTION 150 SF ROOM AREA <br />EXHAUST DUCT UP IS DRAWN, SAME DISCIPLINE <br />SQUARE NECK SUPPLY DIFFUSER/ <br />DUCTWORK LINE CALLOUTS DETAIL REFERENCE NORTH ARROW <br />_ GRILLE/REGISTER DETAIL NUMBER INDICATES DIRECTION <br />XXX DETAIL REFERENCE TYPE OF TRUE NORTH <br />ROUND NECK SUPPLY DIFFUSER/ DESIGNATION DESCRIPTION # (WHERE APPLICABLE) N INDICATES DIRECTION <br />GRILLE/REGISTER EA EXHAUST AIR X00-00 OF PROJECT NORTH <br />SHEET WHERE DETAIL LEVEL <br />MA MAKEUP AIR IS DRAWN, SAME DISCIPLINE <br />RETURN GRILLE OA OUTSIDE AIR <br />PEA PROCESS EXHAUST AIR CALLOUT <br />LEVEL NAME <br />PEC PROCESS EXHAUST CHUTE _ _ — <br />PRA PROCESS RETURN AIR DETAIL NUMBER 0'-0" <br />EXHAUST GRILLE PSA PROCESS SUPPLY AIR XXX--- CALLOUT REFERENCE TYPE <br />RAS REACTIVATION AIR SUPPLY # (WHERE APPLICABLE) MATCH LINE <br />RA RETURN AIR X00-00 MATCHLINE <br />WALL MOUNTED DIFFUSERIGRILLE SA SUPPLY AIR — SHEET WHERE DETAIL <br />IS DRAWN, SAME DISCIPLINE RE:X00-00 <br />FLEXIBLE DUCT <br />BREAK LINE <br />OT THERMOSTAT DIFFUSER CALLOUTS J <br />HO HUMIDISTAT EXTERIOR ELEVATION REFERENCE <br />DESIGNATION PLAN ELEVATION MARKER <br />FIRE AND SMOKE DAMPER & NUMBER # ELEVATION NUMBER HEIGHT ABOVE / BELOW <br />FSD 1 X00-00 SHEET WHERE ELEVATION ESTABLISHED 0.0 ELEVATION <br />TO NECK SIZE +/_ 0" <br />FLO AIR A EAL IS DRAWN, SAME DISCIPLINE <br />TYPICAL OF <br />FIRE DAMPER - CFM INTERIOR ELEVATION REFERENCE (SINGLE AND MULTIPLE) <br />FD DESIGNATION DESCRIPTION ELEVATION NUMBER EQUIPMENT TAG <br /># XXXC"'.0". <br />XXX ELEVATION REFERENCE TYPE TAG ID <br />MOTOR OPERATED DAMPER EG EXHAUST GRILLE (WHERE APPLICABLE) <br />ER EXHAUST REGISTER X00-00 <br />MD LRG LINEAR RETURN GRILLE <br />LSD LINEAR SUPPLY DIFFUSER DEMOLITION EXTENT <br />MANUAL VOLUME DAMPER RG RETURN GRILLE <br />RR RETURN REGISTER <br />VD SD SUPPLY DIFFUSER SHEET WHERE ELEVATION IS <br />SG SUPPLY GRILLE DRAWN, SAME DISCIPLINE <br />SR SUPPLY REGISTER CONNECT TO EXISTING <br />BALANCED BACKDRAFT DAMPER TG TRANSFER GRILLE REFERENCE TYPES (SECTION 1 DETAIL I CALLOUT I ELEVATION <br />BD OPP = OPPOSITE # OPTIONAL NUMBER DESIGNATION <br />SYM =SIMILAR <br />SMOKE DAMPER TYP = TYPICAL <br />SD SHEET NOTE REFERENCE <br />DEMOLITION LINEWORK <br />BLAST GATE SHEET NOTE (DEMO AND NEW WORK) OBJECT TO BE REMOVED <br />SEE NOTE LEGEND ON SAME SHEET. <br />BG---------------------- <br />PATH OF EGRESS <br />AD ACCESS DOOR IN CEILING/WALL <br />CONSULTING ARCHITECT/ENGINEER <br />I CLARK, RICHARDSON AND BISKUP <br />CONSULTING ENGINEERS, INC. <br />CRB ARCHITECTS -ENGINEERS P.C. <br />C1 GLENLAKE PARKWAY <br />SUITE 600 <br />\ ATLANTA, GA 30328 <br />PHONE: 404-860-1440 <br />FAX: 404-860-1442 <br />PROJECT TITLE <br />ZEPHYRHILLS LINE 12 <br />REV <br />BY <br />DATE <br />DESCRIPTION <br />0 <br />GJH <br />25AUG21 <br />ISSUED FOR BID <br />1 <br />GJH <br />22SEP21 <br />ISSUED FOR PERMIT <br />LICENSEE . %IA11 111 <br />Gordon James Handziuk, PE <br />State of Florida <br />Professional Engineer <br />License No. 91122 <br />This item has been digitally signed and <br />sealed by Gordon James Handziuk, PE <br />on the date adjacent to the seal. <br />Printed copies of this document are not <br />considered signed and sealed and the <br />signature must be verified on any <br />electronic copies. <br />XI, <br />III 122 <br />'M1 3 v. z <br />oe <br />��m �'�'► <br />61�1 N- <br />•«����� <br />1;fill 10 <br />29 Sep 2021 <br />CRB ARCHITECTS -ENGINEERS P.C. LICENSE #09000002537 <br />CRB CONSULTING ENGINEERS, INC LICENSE #F96000003389 <br />INFORMATION CONTAINED HEREIN IS CONSIDERED CONFIDENTIAL. THIS <br />DOCUMENT IS NOT TO BE USED, REPRODUCED, OR DISCLOSED IN WHOLE OR <br />PART WITHOUT THE PRIOR WRITTEN PERMISSION OF BLUETRITON BRANDS. <br />PROJ. NO. <br />217043.00 <br />DESIGNED BY: <br />SB <br />SCALE: <br />NOT TO SCALE <br />CHECKED BY: <br />GJH <br />SHEET SIZE: <br />30x42 <br />APPROVED BY: <br />GJH <br />DRAWING TITLE <br />MECHANICAL <br />LEAD SHEET <br />DRAWING NUMBER <br />MOO-01 <br />