Laserfiche WebLink
POWER DEVICE <br />SYMBOLS <br />POWER EQUIPMENT <br />SYMBOLS <br />FIRE ALARM & DETECTION <br />SYSTEM SYMBOLS <br />LUMINAIRE <br />SYMBOLS <br />GENERAL NOTES <br />WALL <br />CEILING FLOOR <br />MOUNT <br />MOUNT MOUNT <br />--e <br />e <br />Fe—i <br />SIMPLEX RECEPTACLE - 125V,2P,3W* <br />e <br />FEJ) <br />DUPLEX RECEPTACLE - 125V,2P,3W* <br />® <br />QUADRUPLEX RECEPTACLE - 125V,2P,3W* <br />---e <br />e <br />SIMPLEX RECEPTACLE <br />ON UPS OR STANDBY POWER - 125V,2P,3W* <br />8 <br />DUPLEX RECEPTACLE <br />ONSTANDBYDOWER- 125V,2P,3W* <br />® <br />D <br />ON STANDBY POWERT125V,2P,3W* <br />O <br />DUPLEX RECEPTACLE <br />ON UPS POWER - 125V,2P,3W* <br />® <br />QUADRUPLEX RECEPTACLE <br />ON UPS POWER- 125V,2P 3W* <br />0 <br />0 <br />SPECIAL PURPOSE RECEPTACLE- <br />__6 <br />® <br />SPECIAL PURPOSE RECEPTACLE <br />ON STANDBY POWER*" <br />0 <br />O <br />❑ <br />SPECIAL PURPOSE RECEPTACLE <br />BL <br />ON UPS POWER*" <br />* NEMA 250 ENCLOSURE RATING SHALL BE <br />INDICATED ON PLANS, RECEPTACLE TYPE <br />DESIGNATION, OR TEXT SHEET OR GENERAL <br />NOTATION. NEMA 1 UNLESS NOTED OTHERWISE. <br />"NEMA RECEPTACLE WD 1 CONFIGURATION SHALL <br />BE INDICATED ON PLANS. <br />L5-20R UNLESS OTHERWISE NOTED. <br />[RECEPTACLE TYPE] <br />GFCI GROUND FAULT CIRCUIT INTERRUPTER <br />RECEPTACLE <br />IG ISOLATED GROUND RECEPTACLE <br />SP SURGE SUPPRESSION RECEPTACLE <br />WP RECEPTACLE WITH WEATHERPROOF <br />COVER <br />TP TAMPER -PROOF RECEPTACLE <br />XP EXPLOSION -PROOF RECEPTACLE <br />USB RECEPTACLE WITH INTEGRAL USB PORT <br />SW SWITCHED OR CONTROLLED RECEPTACLE <br />�* <br />WALL MOUNTED RECEPTACLE WITH <br />INTEGRAL SWITCH <br />*REFER TO RECEPTACLE SYMBOLOGY LEGEND <br />ABOVE FOR POWER TYPE, ENCLOSURE TYPE, <br />AND RECEPTACLE CONFIGURATION. <br />O <br />JUNCTION BOX <br />F JQ <br />WALL MOUNTED JUNCTION BOX <br />J 5 30R <br />CEILING MOUNTED JUNCTION BOX <br />W/ HANGING RECEPTACLE CORD <br />[INDICATES NEMA WD 1 CONFIGURATION]. <br />L5-20R UNLESS OTHERWISE NOTED. <br />® <br />PULL BOX <br />® <br />POWER SUPPLY <br />I'Q <br />WALL MOUNTED CLOCK HANGER RECEPTACLE <br />FF <br />WALL MOUNTED POWER FEED TO PRE -WIRED <br />FURNITURE SYSTEM <br />FF <br />FLOOR BOX POWER FEED TO PRE -WIRED <br />FURNITURE SYSTEM <br />FB <br />COMBINATION POWER AND DATA FLOOR BOX <br />PP <br />DUAL CHANNEL POWER & TELE/DATA POLE <br />(FROM CEILING) <br />PL <br />PLUG LOAD CONTROLLER <br />OP <br />FIRE RATED POKE-THRU ASSEMBLY <br />X <br />~— <br />[POKE-THRU FUNCTION] <br />AV POWER, VOICE, DATA AND A/V <br />FF POWER FEED TO PRE -WIRED FURNITURE SYSTEM <br />PX POWER, VOICE AND DATA <br />P POWER DUPLEX RECEPTACLE <br />POWER SURFACE RACEWAY <br />WITH DUPLEX RECEPTACLES <br />STANDARD MOUNTING HEIGHTS <br />DEVICE <br />MOUNTING HEIGHT AFF <br />TO: <br />PANELBOARD <br />6'- 6" <br />TOP <br />TOGGLE SWITCH <br />4'- 0" <br />TOP <br />TELEPHONE/DATA OUTLET <br />1'- 6" <br />CENTER <br />TELE/DATA OUTLET (CLEAN ROOM) <br />4'- 0" <br />TOP <br />TELE/DATA OUTLET (ADA) <br />4'- 0" <br />TOP <br />AUDIO-VISUAL OUTLETS <br />1'- 6" <br />CENTER <br />DISCONNECT SWITCH <br />6'- 6" MAX. <br />TOP <br />MOTOR STARTER AND VFD <br />6'- 6" MAX. <br />TOP <br />GROUND BUS BAR <br />4'- 0" MAX. <br />CENTER <br />FIRE ALARM PULL STATION <br />4' - 0" <br />TOP <br />FIRE ALARM HORN/STROBE <br />6'- 8" <br />BOTTOM <br />WALL PHONE <br />6-0" <br />CENTER <br />EXIT SIGN <br />NOTE 8, 9 <br />NOTE 8, 9 <br />CARD READER AND KEYPAD <br />4' - 0" <br />TOP <br />DOOR RELEASE BUTTON <br />4'- 0" <br />TOP <br />DOOR OPERATOR <br />4' - 0" <br />TOP <br />CLOCK RECEPTACLE <br />8'- 0" <br />CENTER <br />WALL SPEAKER <br />8'- 0" <br />CENTER <br />RECEPTACLE <br />1'- 6" <br />CENTER <br />RECEPTACLE (ABOVE COUNTER) <br />6", NOTE 5 <br />BOTTOM <br />RECEPTACLE (CLEAN ROOM) <br />4' - 0" <br />TOP <br />DIGITAL MONITOR OR SCREEN <br />5' - 0" <br />CENTER <br />1. ALL MOUNTING HEIGHTS SHALL BE AS LISTED ABOVE UNLESS <br />OTHERWISE INDICATED ON DRAWINGS. <br />2. ALL MOUNTING HEIGHTS SHALL BE IN ACCORDANCE WITH THE <br />AMERICANS WITH DISABILITIES ACT. <br />3. MOUNTING HEIGHTS AND LOCATIONS OF DEVICES SHOWN ON <br />HORIZONTAL AND VERTICAL CHASES SHALL BE COORDINATED WITH <br />OTHER UTILITIES IN THE CHASE. REFER TO ARCHITECTURAL PLANS <br />AND ELEVATIONS FOR CHASE LOCATIONS AND MOUNTING LOCATIONS, <br />4. MOUNTING HEIGHTS AND LOCATIONS OF SURFACE PLUGMOLD <br />RACEWAY SHALL BE COORDINATED WITH COUNTER TOPS AND BACK <br />SPLASHES. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR <br />COUNTER LOCATIONS AND DIMENSIONS. <br />5. '+' SHOWN BESIDE A DEVICE INDICATES THAT IT SHALL BE INSTALLED <br />ABOVE COUNTER, AND BACK SPLASH WHERE APPLICABLE. INSTALL <br />OUTLETS 6" ABOVE COUNTER TOP, COORDINATE EXACT HEIGHT WITH <br />ARCHITECTURAL ELEVATIONS AND/OR CASEWORK DRAWINGS. <br />6. 'UC' SHOWN BESIDE A DEVICE INDICATES THAT IT SHALL BE INSTALLED <br />4" BELOW COUNTER OR 18" ABOVE FINISHED FLOOR, WHICHEVER IS <br />FEASIBLE. <br />7. '+P' SHOWN BESIDE A DEVICE INDICATES IT SHALL BE INSTALLED 18" <br />ABOVE PLATFORM. <br />8. WALL MOUNTED EXIT SIGNS INSTALLED ABOVE DOORS SHALL BE <br />INSTALLED V-0" ABOVE THE TOP OF THE DOOR FRAME TO THE BOTTOM <br />OF THE EXIT SIGN. WHERE CEILING HEIGHT DOES NOT ALLOW FOR <br />MOUNTING AT THIS LOCATION, INSTALL SIGN CENTERED BETWEEN <br />DOOR FRAME AND CEILING. <br />9. PENDANT MOUNTED EXIT SIGNS SHALL BE INSTALLED AT 10'-0" AFF AS <br />MEASURED TO THE BOTTOM OF THE EXIT SIGN. ADJUST AS NECESSARY <br />IN UNFINISHED SPACES TO CLEAR WORK PERFORMED BY OTHER <br />TRADES. INSTALL EXIT SIGN SO LINE OF SIGHT IS MAINTAINED AND NOT <br />HINDERED BY WORK FROM OTHER TRADES. <br />ST WALL OR SURFACE MOUNTED TOGGLE SWITCH <br />_____ [SUBSCRIPT INDICATES TYPE OF SWITCH] <br />P SWITCH WITH PILOT LIGHT <br />V VARIABLE SPEED CONTROL SWITCH <br />T FRACTIONAL HORSEPOWER MANUAL MOTOR <br />CONTROLLER WITH OVERLOADS <br />M MANUAL MOTOR CONTROLLER <br />CO SINGLE POLE, CENTER -OFF MOMENTARY <br />CONTACT SWITCH <br />3P SINGLE POLE, THREE -POSITION, CENTER -OFF, MOMENTARY <br />CONTACT SWITCH <br />R/L RAISE/LOWER SWITCH <br />q:1 NONFUSIBLE SAFETY DISCONNECT SWITCH <br />*NEMA ENCLOSURE TYPE SHALL BE <br />INDICATED ON PLANS. <br />NEMA 1 UNLESS OTHERWISE NOTED. <br />[DISCONNECT TYPE] <br />R RECESSED OR FLUSH MOUNTED <br />C AUXILIARY CONTACT <br />21* ENCLOSED CIRCUIT BREAKER <br />q!] * FUSIBLE SAFETY DISCONNECT SWITCH <br />®* MOTOR STARTER <br />* COMBINATION MOTOR STARTER <br />WITH FUSIBLE DISCONNECT SWITCH <br />4 * COMBINATION MOTOR STARTER <br />W/ MOTOR CIRCUIT PROTECTOR <br />Lwim 208/120V DISTRIBUTION OR BRANCH PANELBOARD <br />m 240/120V DISTRIBUTION OR BRANCH PANELBOARD <br />480V OR 480/277V DISTRIBUTION OR BRANCH PANELBOARD <br />ED VARIABLE FREQUENCY DRIVE OR CONTROLLER, <br />CONTROL PANEL OR OTHER DISTRIBUTION EQUIPMENT <br />SPD WALL MOUNTED SURGE PROTECTION DEVICE <br />COLUMN LINE REFERENCE <br />1 <br />i <br />i <br />Q <br />FIRE ALARM MANUAL PULL STATION <br />F <br />WALL OR CEILING MOUNTED FIRE ALARM AUDIBLE <br />110 <br />AND VISUAL DEVICE; CANDELA RATING AS NOTED <br />WALL OR CEILING MOUNTED FIRE AUDIBLE DEVICE <br />F, <br />CEILING MOUNTED FIRE ALARM VISUAL DEVICE <br />IF <br />WALL MOUNTED FIRE ALARM VISUAL DEVICE <br />FIRE ALARM BELL <br />FIRE ALARM TROUBLE BELL <br />FACP <br />FIRE ALARM CONTROL PANEL <br />[CONTROL PANEL FUNCTION] <br />FACP FIRE ALARM MAIN CONTROL PANEL <br />FAA FIRE ALARM ANNUNCIATOR PANEL <br />PRE PRE -ACTION SPRINKLER SYSTEM CONTROL PANEL <br />SAP SPRINKLER ALARM SYSTEM CONTROL PANEL <br />FATC FIRE ALARM TERMINAL CABINET <br />BATT FIRE ALARM BATTERY CABINET <br />NAC FIRE ALARM POWER BOOSTER PANEL <br />GACP GAS DETECTION & ALARM CONTROL PANEL <br />FD_H_1 <br />MAGNETIC DOOR HOLDER <br />© <br />FIRE ALARM FLOW SWITCH <br />© <br />FIRE ALARM TAMPER SWITCH <br />INTELLIGENT SYSTEM MONITOR & CONTROL DEVICES <br />Cam— <br />[RELAY FUNCTION] <br />C CONTROL <br />I ISOLATION <br />M MONITOR <br />O <br />AUTOMATIC SMOKE/HEAT DETECTOR <br />P <br />�— <br />[DETECTOR CLASSIFICATION] <br />AS AIR SAMPLING SMOKE DETECTOR <br />BR BEAM TYPE SMOKE DETECTOR - RECEIVER <br />BT BEAM TYPE SMOKE DETECTOR - TRANSMITTER <br />D DUCT MOUNTED, PHOTOELECTRIC SMOKE <br />DETECTOR <br />F FIXED TEMPERATURE HEAT DETECTOR <br />FR COMBINATION RATE OF RISE PLUS <br />FIXED TEMPERATURE HEAT DETECTOR <br />I IONIZATION SMOKE DETECTOR <br />P PHOTOELECTRIC SMOKE DETECTOR <br />R RELAY BASE SMOKE DETECTOR <br />RR RATE OF RISE HEAT DETECTOR <br />SB SOUNDER BASE SMOKE DETECTOR <br />SS SINGLE STATION SMOKE DETECTOR <br />O <br />AUTOMATIC GAS DETECTOR <br />A <br />�— <br />[DETECTOR CLASSIFICATION] <br />A AMMONIA DETECTOR <br />CH4 METHANE DETECTOR <br />CO CARBON MONOXIDE DETECTOR <br />CO2 CARBON DIOXIDE DETECTOR <br />HCL HYDROGEN CHLORIDE DETECTOR <br />N2 NITROGEN DETECTOR <br />02 OXYGEN DETECTOR <br />Fso FIRE SMOKE DAMPER <br />RTS SMOKE DETECTOR AND/OR DAMPER REMOTE TEST <br />SWITCH AND STATUS INDICATOR <br />GENERAL <br />BUILDING SECTION REFERENCE <br />SECTION NUMBER <br /># <br />X00-00 SHEET WHERE SECTION <br />IS DRAWN, SAME DISCIPLINE <br />WALL SECTION REFERENCE <br />SECTION NUMBER <br />XXX WALL SECTION REFERENCE TYPE <br /># (WHERE APPLICABLE) <br />X00-00 SHEET WHERE SECTION <br />IS DRAWN, SAME DISCIPLINE <br />DETAIL REFERENCE <br />DETAIL NUMBER <br />XXX DETAIL REFERENCE TYPE # <br />(WHERE APPLICABLE) <br />X00-00 SHEET WHERE DETAIL <br />IS DRAWN, SAME DISCIPLINE <br />CALLOUT <br />DETAIL NUMBER <br />XXX-- CALLOUT REFERENCE TYPE # <br />(WHERE APPLICABLE) <br />X00-00 <br />— SHEET WHERE DETAIL <br />IS DRAWN, SAME DISCIPLINE <br />L_J <br />EXTERIOR ELEVATION REFERENCE <br />#-- ELEVATION NUMBER <br />lk <br />X00-00 SHEET WHERE ELEVATION <br />IS DRAWN, SAME DISCIPLINE <br />INTERIOR ELEVATION REFERENCE (SINGLE AND MULTIPLE) <br />ELEVATION NUMBER <br />XXX # XXX ELEVATION REFERENCE TYPE <br />* (WHERE APPLICABLE) <br />X00-00 <br />SHEET WHERE ELEVATION IS <br />DRAWN, SAME DISCIPLINE <br />REFERENCE TYPES (SECTION 1 DETAIL 1 CALLOUT / ELEVATION) <br />OPP = OPPOSITE <br />SYM = SIMILAR <br />TYP = TYPICAL <br />SHEET NOTE REFERENCE <br />DRAWING REVISION <br />REVISION NUMBER, SEE <br />DESCRIPTION IN TITLE <br />BLOCK SAME SHEET <br />REVISION AREA <br />DIMENSIONS <br />(+/-) DIMENSIONS ARE FOR <br />REFERENCE ONLY, CONTRACTOR <br />SHALL FIELD VERIFY AND NOTIFY <br />ARCHITECT/ENGINEER OF ANY <br />DISCREPANCIES <br />X' - X SET DIMENSIONS <br />*- (NON +/- DIMENSIONS) <br />ROOM ! SPACE NAME <br />ROOM NAME ROOM NAME <br />101 - ROOM NUMBER <br />150 SF ROOM AREA <br />NORTH ARROW <br />INDICATES DIRECTION <br />OF TRUE NORTH <br />N INDICATES DIRECTION <br />OF PROJECT NORTH <br />LEVEL <br />_ - LEVEL NAME <br />0'-0" <br />MATCH LINE <br />_ MATCHLINE <br />RE:X00-00 <br />BREAK LINE <br />PLAN ELEVATION MARKER <br />HEIGHT ABOVE / BELOW <br />ESTABLISHED 0.0 ELEVATION <br />EQUIPMENT TAG <br />TAG ID <br />DEMOLITION EXTENT <br />CONNECT TO EXISTING <br />�# OPTIONAL NUMBER DESIGNATION <br />DEMOLITION LINEWORK <br />SHEET NOTE (DEMO AND NEW WORK) OBJECT TO BE REMOVED <br />SEE NOTE LEGEND ON SAME SHEET. <br />:V <br />LUMINAIRE <br />LUMINAIRE TYPE <br />LP-1/1 a <br />0 1 <br />CIRCUIT NUMBER OF PANELBOARD <br />PANELBOARD NAME <br />BUILDING CONTROL ZONE (AS APPLICABLE) <br />LUMINAIRE SYMBOL <br />SUSPENDED HIGH BAY EMERGENCY <br />LUMINARIES INDICATED WITH DIAGONAL <br />SOLD FILL HATCH <br />SUSPENDED HIGH BAY LUMINAIRE <br />CEILING OR PENDANT MOUNTED SINGLE -SIDED <br />EXIT SIGN FIXTURE, ARROWS AS INDICATED <br />CEILING OR PENDANT MOUNTED DUAL -SIDED <br />EXIT SIGN FIXTURE, ARROWS AS INDICATED <br />WALL MOUNTED EXIT SIGN FIXTURE, ARROWS AS INDICATED <br />WALL MOUNTED COMBINATION EXIT SIGN/EMERGENCY <br />LUMINAIRE, ARROWS AS INDICATED <br />F 0 WALL MOUNTED LIGHTING CONTROL SENSOR <br />�S CEILING MOUNTED LIGHTING CONTROL SENSOR <br />DT <br />[SUBSCRIPT INDICATES SENSOR TYPE] <br />OS OCCUPANCY SENSOR <br />PS PHOTOCELL (DAYLIGHT) SENSOR <br />[SUBSCRIPT INDICATES TYPE OF SWITCH] <br />FOR CEILING AND WALL MOUNTED <br />DT DUALTECHNOLOGY <br />PIR PASSIVE INFRARED TECHNOLOGY <br />UT ULTRASONIC TECHNOLOGY <br />MP MICROPHONIC TECHNOLOGY <br />H HALLWAY TYPE PASSIVE INFRARED TECHNOLOGY <br />LB LOW BAY TYPE DUAL TECHNOLOGY <br />HB HIGH BAY TYPE DUAL TECHNOLOGY <br />L LINE VOLTAGE TYPE <br />LV LOW VOLTAGE TYPE <br />LP LIGHTING POWER SUPPLY OR POWER PACK <br />S2 FLUSH WALL OR SURFACE MOUNTED LUMINAIRE SWITCH <br />V_ <br />7SUBSCRIPT <br />ONTROL DEVICE INDICATES TYPE OF SWITCH] <br />2 DOUBLE POLE SINGLE THROW SWITCH <br />3 THREE-WAY SWITCH <br />4 FOUR-WAY SWITCH <br />D SINGLE POLE LINE VOLTAGE DIMMING SWITCH <br />LV LOW VOLTAGE SWITCH WITH CONNECTION TO <br />LIGHTING CONTROL PANEL OR POWER PACK <br />KP LOW VOLTAGE KEYPAD SWITCH WITH <br />CONNECTION TO LIGHTING CONTROL PANEL <br />K KEYED SWITCH <br />OV LOW VOLTAGE OVERRIDE SWITCH <br />LM LOW VOLTAGE MASTER SWITCH <br />TC TIME CONTROL SWITCH <br />OS OCCUPANCY SENSOR <br />PC PHOTOCELL OR PHOTOSENSOR <br />#B [NUMBER] -BUTTON SWITCH <br />VS VACANCY SENSOR <br />MS MOMENTARY SWITCH <br />LD LOW VOLTAGE DIMMING <br />IS ILLUMINATED SWITCH <br />CONDUIT AND WIRING <br />SYMBOLS <br />RP-2/1,3,5 <br />CIRCUIT NUMBER(S) OF PANELBOARD <br />PANELBOARD NAME <br />1. ALL ELECTRICAL MATERIAL AND EQUIPMENT SHALL BE NEW, NRTL <br />APPROVED AND BEAR THE NRTL LABEL. <br />2. CONTRACTOR IS RESPONSIBLE FOR SCHEDULING OF LIGHTING, <br />POWER, FIRE ALARM, ETC. SHUT -DOWNS WITH THE OWNER. <br />COORDINATION OF NIGHTS AND WEEKEND ELECTRICAL WORK SHALL <br />BE BY THE ELECTRICAL CONTRACTOR, ADJACENT AREAS WILL <br />REMAIN IN OPERATION DURING NORMAL WORKING HOURS. <br />3. CONDUIT ROUTING SHOWN ON THE DRAWINGS IS SCHEMATIC. <br />CONTRACTOR TO COORDINATE INSTALLATION WITH EXISTING <br />LIGHTING AND MECHANICAL SYSTEMS, AND WITH PIPING, PLUMBING <br />AND MECHANICAL INSTALLATION ON THIS PROJECT. <br />4. PROVIDE A SEPARATE GROUNDED CONDUCTOR (NEUTRAL) WIRE WITH <br />EACH CIRCUIT, UNLESS NOTED OTHERWISE. USE OF MULTIWIRE <br />BRANCH CIRCUITS IS NOT ACCEPTABLE. <br />5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED <br />SUPPORTS FOR ALL DEVICES AND EQUIPMENT FURNISHED BY THE <br />ELECTRICAL CONTRACTOR AND SHALL NOT RELY ON SUPPORTS <br />PROVIDED BY OTHER TRADES. SUPPORT SUCH EQUIPMENT PER <br />APPROVED GOVERNING CODES OR PER APPROVAL OF THE ENGINEER. <br />UNACCEPTABLE WORKMANSHIP OR MATERIALS SHALL BE REPLACED <br />AT THE REQUEST OF THE ENGINEER AT THE CONTRACTOR'S <br />EXPENSE. <br />6. ALL ELECTRICAL PERMITS AND INSPECTION FEES SHALL BE SECURED <br />AND PAID BY THE ELECTRICAL CONTRACTOR. <br />7. THE CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR <br />ALL FLOOR PLAN DIMENSIONS. <br />8. ALL CONDUIT, HANGERS, AND SUPPORTS SHALL BE INSTALLED SUCH <br />THAT THEY DO NOT INTERFERE WITH EQUIPMENT ACCESS OR <br />EQUIPMENT REMOVAL SPACE. <br />DEFERRED PERMIT <br />SUBMITTALS <br />1. FIRE ALARM SYSTEM INCLUDING BUT NOT LIMITED TO: BATTERY <br />CALCULATIONS, VOLTAGE DROP CALCULATIONS, NOTIFICATION <br />AND INITIATION DEVICE LOCATIONS, AND MANUFACTURER <br />CUTSHEETS FOR EQUIPMENT INSTALLED. SYSTEM SHALL BE IN <br />COMPLIANCE WITH INTERNATIONAL BUILDING CODE AND NFPA 72 <br />REQUIREMENTS. REFER TO MORE INFORMATION IN <br />SPECIFICATION SECTION 283100. <br />CONSULTING ARCHITECT/ENGINEER <br />I CLARK, RICHARDSON AND BISKUP <br />CONSULTING ENGINEERS, INC. <br />C � CRBARCH lTECTS-ENGINEERS P.C. <br />1 GLENLAKE PARKWAY <br />SUITE 600 <br />\ ATLANTA, GA 30328 <br />PHONE: 404-860-1440 <br />FAX: 404-860-1442 <br />PROJECT TITLE <br />ZEPHYRHILLS LINE 12 <br />REV <br />BY <br />DATE <br />DESCRIPTION <br />0 <br />MW <br />25AUG21 <br />ISSUED FORBID <br />1 <br />MW <br />22SEP21 <br />ISSUED FOR PERMIT <br />LICENSEE <br />Michael Wagner, PE <br />State of Florida <br />Professional Engineer <br />License No. 57097 <br />This item has been digitally signed and <br />sealed by Michael Wagner on the date <br />adjacent to the seal. <br />Printed copies of this document are not <br />considered signed and sealed and the <br />signature must be verified on any <br />electronic copies. <br />29 Sep 2021 <br />CRB ARCHITECTS -ENGINEERS P.C. LICENSE #09000002537 <br />CRB CONSULTING ENGINEERS, INC LICENSE #F96000003389 <br />INFORMATION CONTAINED HEREIN IS CONSIDERED CONFIDENTIAL. THIS <br />DOCUMENT IS NOT TO BE USED, REPRODUCED, OR DISCLOSED IN WHOLE OR <br />PART WITHOUT THE PRIOR WRITTEN PERMISSION OF BLUETRITON BRANDS. <br />PROJ. NO. <br />217043.00 <br />DESIGNED BY: <br />GW <br />SCALE: <br />NOT TO SCALE <br />CHECKED BY: <br />MW <br />SHEET SIZE: <br />30x42 <br />APPROVED BY: <br />MW <br />DRAWING TITLE <br />ELECTRICAL <br />LEAD SHEET <br />PATH OF EGRESS <br />DRAWING NUMBER <br />EOO-01 <br />