Laserfiche WebLink
PANEL SCHEDULE NOTES <br />1. ALL ITEMS SHOWN IN THIN/LIGHT LINEWEIGHT ARE EXISTING TO REMAIN <br />OR WORK BY OTHERS. ALL ITEMS SHOWN IN BOLD/DARK LINEWEIGHT <br />ARE NEW WORK. <br />2. PROVIDE NEW TYPE WRITTEN PANELBOARD DIRECTORIES FOR ALL <br />PANELBOARDS MODIFIED AS PART OF THIS SCOPE OF WORK. <br />LUMINAIRE SCHEDULE <br />TYPE <br />DESCRIPTION <br />LENSIOPTICS <br />MOUNTING <br />MANUFACTURER <br />CATALOG NUMBER <br />INPUT WATTS <br />VOLTAGE <br />REMARKS <br />CLE-D1 <br />18K LUMEN LED 277V 60Hz 5000K COLOR TEMPERATURE 80CRI <br />LED <br />SUSPENDED <br />DIGITAL LUMENS <br />CLE-DI-CE-W-850 <br />150 VA <br />277 V <br />EXISTING, PROVIDED FOR REFERENCE ONLY. <br />SUSPENDED HIGH BAY FIXTURE <br />CLE-F <br />24K LUMEN LED 277V 60Hz 5000K COLOR TEMPERATURE 80CRI <br />LED <br />SUSPENDED <br />DIGITAL LUMENS <br />CLE-F1-CE-W-850 <br />150 VA <br />277 V <br />EXISTING. PROVIDED FOR REFERENCE ONLY. <br />SUSPENDED HIGH BAY FIXTURE <br />DLE-18 <br />18K LUMEN LED 277V 60Hz 5000K COLOR TEMPERATURE 70CRI <br />LED <br />SUSPENDED <br />DIGITAL LUMENS <br />DLE-18-ST-W-750-20-0-20 <br />178 VA <br />277 V <br />EXISTING. PROVIDED FOR REFERENCE ONLY. <br />SUSPENDED HIGH BAY FIXTURE <br />DLE-24 W <br />LED SUSPENDED HIGH BAY FIXTURE <br />LED <br />SUSPENDED <br />DIGITAL LUMENS <br />DLE-24-ST-W-754 20-0-0-20 <br />232 VA <br />277 V <br />EXISTING. PROVIDED FOR REFERENCE ONLY. <br />X1 <br />CEILING MOUNTED EXIT SIGN, DOUBLE FACE <br />RED LED <br />UNIVERSAL MOUNT <br />5 VA <br />277 V <br />PROVIDE MOUNTING, NUMBER OF FACES, AND ARROWS AS INDICATED ON PLANS <br />PANELBOARD: H2 (EXISTING) <br />BUS RATING: 400 A MOUNTING: SURFACE SUPPLY FROM: MCB SWBD MINIMUM AIC RATING: SEE NOTE 2 <br />MAIN TYPE: MLO - 400 A ENCLOSURE: NEMA 1 LOCATION: Room 07 ACCESSORIES: <br />VOLTAGE: 480/277V 30 4W <br />NOTE <br />CKT <br />DESCRIPTION <br />CONDUCTORS <br />COND <br />AMP <br />P <br />A <br />B <br />C <br />P <br />AMP <br />COND <br />CONDUCTORS <br />DESCRIPTION <br />CKT <br />NOTE <br />1 <br />WALL PACKS EAST 4fALL / S <br />20 <br />1 <br />3.88 <br />2.91 <br />K" ,,. <br />3 <br />15 <br />EX FANS NORTH WALL <br />2 <br />3 <br />WALL PACKS EAST WALL,' N <br />20 <br />1 <br />3.88 <br />2.91 <br />4 <br />5 <br />WALL PACKS NORTH W I E <br />20 <br />1 <br />3.88 <br />2.91 <br />6 <br />7rvALL <br />PACKS NORTHv' CEN <br />20 <br />1 <br />3.88 <br />0.00 <br />3 <br />15 <br />SPARE <br />8 <br />9 <br />PARKING LOT LIGHTS 1 NE <br />50 <br />1 <br />9.70 <br />0.00 <br />10 <br />11 <br />PARKING LOT LIGHTS i N <br />50 <br />1 <br />z <br />9.70 <br />0.00 <br />12 <br />13 <br />LIGHTING PHOTO CELL r CO <br />20 <br />1 <br />3.88 <br />19.40 <br />s . <br />,• 3 <br />� r <br />19.40 <br />� <br />.1,00 <br />,�,3�� <br />TRANSFORMER TI �._ 2 <br />��AN�SFOte�1ER � � D;' 0�:4 <br />14 <br />- <br />15 <br />SPARE <br />__ <br />50 <br />3 <br />0.00 <br />1940 <br />............... <br />:> $ .? <br />0.00 <br />16 <br />17 <br />18 <br />19 <br />0.00 <br />2.91 <br />" <br />..... <br />1 <br />1 S <br />EXIT EMER. LIGHTS <br />20 <br />21 <br />WELDING LIGI-IT'S <br />1 20 <br />1 <br />...;,.. <br />3.88 <br />2.91 <br />1 <br />15 <br />EXIT + EMER. LIGHTS <br />22 <br />1 <br />23 <br />INLINE WATER HEATER IWH•1 <br />2#10, #10G <br />314" <br />30 <br />1 <br />5.82 <br />3.88 <br />6.00 <br />5.82 i <br />30 <br />FORKLIFT LIGHT <br />24 <br />25 <br />WELD AC <br />30 <br />3 <br />w <br />3.88 <br />20 <br />FORKLIFT FAN 01 <br />26 <br />27 <br />5.82 <br />3.88 <br />5.82 <br />28 <br />29 <br />30 <br />31 <br />FORK AC <br />30 <br />3 <br />5.82 <br />3.88 <br />5.82 <br />- <br />3.88 <br />., <br />5.82 <br />3 <br />3.88 <br />20 <br />VELDING RM EX FAN <br />32 <br />33 <br />34 <br />35 <br />36 <br />37 <br />LIGHTING AREA B ROW 1 <br />20 <br />1 <br />3.88 <br />0.00 <br />0.00 <br />20 <br />- <br />- <br />SPARE <br />38 <br />39 <br />LIGHTING AREA B ROW2 <br />20 <br />1 <br />x <br />3.88 0.00 <br />40 <br />41 <br />LIGHTING AREA B ROW 3 <br />20 <br />1 <br />3.88 <br />42 <br />TOTAL KVA: 60.13 kVA 65.94 kVA 70.98 kVA <br />TOTAL AMPS: 217 A 241 A 259 A <br />LOAD CLASSIFICATION <br />CONNECTED LOAD <br />DEMAND FACTOR <br />ESTIMATED DEMAND <br />PANEL TOTALS <br />EXISTING LOAD <br />191048 VA <br />125.00% <br />238810 VA <br />TOTAL CONNECTED KVA: <br />197.05 kVA <br />EQUIPMENT - GENERAL <br />6000 VA <br />100.00% <br />6000 VA <br />TOTAL ESTIMATED DEMAND KVA: <br />244.81 kVA <br />TOTAL CONNECTED CURRENT: <br />237 A <br />TOTAL ESTIMATED DEMAND CURRENT: <br />294 A <br />NOTE: VALUES INDICATED FOR EXISTING CONNECTED LOADS IN THE PANEL SCHEDULE ARE BASED ON 70% OF THE TRIP RATING OF THE DEVICE SERVING THE LOAD. ACTUAL LOAD VALUES FOR EXISTING EQUIPMENT <br />ARE UNKNOWN, SINCE THEY WERE NOT AVAILABLE AT THE TIME OF DESIGN. VERIFY PANEL CAPACITY BEFORE ENERGIZING NEW LOAD. <br />NOTE 1: PROVIDE NEW CIRCUIT BREAKER AS INDICATED. <br />NOTE 2: EXISTING PANEL AIC RATING NOT INDICATED ON RECORD DOCUMENTS. CONTRACTOR TO FIELD VERIFY AIC RATING OF EXISTING OVER CURRENT PROTECTION DEVICES AND MATCH FOR NEW OVERCURRENT <br />PROTECTION DEVICE PROVIDED. <br />CONSULTING ARCHITECT/ENGINEER <br />I CLARK, RICHARDSON AND BISKUP <br />CONSULTING ENGINEERS, INC. <br />C � CRB ARCHITECTS -ENGINEERS P.C. <br />1 GLENLAKE PARKWAY <br />SUITE 600 <br />\ ATLANTA, GA 30328 <br />PHONE: 404-860-1440 <br />FAX: 404-860-1442 <br />L <br />PROJECT TITLE <br />ZEPHYRHILLS LINE 12 <br />REV <br />BY <br />DATE <br />DESCRIPTION <br />0 <br />MW <br />25AUG21 <br />ISSUED FOR BID <br />1 <br />MW <br />22SEP21 <br />ISSUED FOR PERMIT <br />LICENSEE <br />Michael Wagner, PE <br />State of Florida <br />Professional Engineer <br />i i } � 7 <br />License No. 57097 <br />\' <br />This item has been digitally signed and <br />.. o. 57D97 "a* <br />sealed by Michael Wagner on the date <br />- ° ~- <br />adjacent to the seal. <br />Printed this document <br />-gip>. ETA fE OF,» <br />copies of are not <br />considered signed and sealed and the <br />«�'�' O <br />signature must be verified on any''t70N <br />Ai��i` <br />electronic copies. <br />r fill t <br />CRB ARCHITECTS -ENGINEERS P.C. LICENSE #09000002537 <br />CRB CONSULTING E 98RS, INC LICENSE #F96000003389 <br />INFORMATION CONTAINED HEREIN IS CONSIDERED CONFIDENTIAL. THIS <br />DOCUMENT IS NOT TO BE USED, REPRODUCED, OR DISCLOSED IN WHOLE OR <br />PART WITHOUT THE PRIOR WRITTEN PERMISSION OF BLUETRITON BRANDS. <br />PROJ, NO. <br />217043.00 <br />DESIGNED BY: <br />KB <br />SCALE: <br />NONE <br />CHECKED BY: <br />MW <br />SHEET SIZE: <br />30x42 <br />APPROVED BY: <br />MW <br />DRAWING TITLE <br />ELECTRICAL <br />PANEL SCHEDULE <br />DRAWING NUMBER <br />E70-01 <br />