� GENERAL NOTES
<br />ACCESSIBILITY LEGEND EGRESS PLAN LEGEND
<br />ACCESSIBLE ROUTE OCCUPANT LOAD TAG
<br />MIN. 4'-0" WIDE WALKWAY, MAX. 1:20 ROOM NAME ROOM NAME
<br />SLOPE. XXX ROOM NUMBER
<br />###
<br />ROOM OCCUPANCY
<br />PATH OF TRAVEL SYMBOLOGY
<br />TRAVEL DISTANCE START POINT
<br />I
<br />COMMON PATH TRAVEL DISTANCE
<br />of EXIT ACCESS TRAVEL DISTANCE
<br />�I N (INCLUDES COMMON PATH
<br />TRAVEL DISTANCE)
<br />�] COMMON PATH OF TRAVEL
<br />i END OF COMMON PATH OF TRAVEL
<br />I
<br />EXIT ACCESS PATH OF TRAVEL
<br />EXIT ACCESS POINT
<br />EXIT DOOR OCCUPANT LOAD TAG
<br />- DIRECTION OF EXIT TRAVEL
<br />EXIT NO. EXIT REFERENCE NUMBER
<br />### ACTUAL OCCUPANT LOAD AT DOOR
<br />OCCUPANCYUSE # �# MAXIMUM OCCUPANT LOAD OF
<br />GROUP LEGEND DOOR
<br />INTERIOR DOOR OCCUPANT LOAD TAG
<br />"A 1" (ASSEMBLY) ® OCCUPANT LOAD AT DOOR
<br />' DIRECTION OF EXIT TRAVEL
<br />W3" (ASSEMBLY- GENERAL /
<br />MISCELLANEOUS) FIRE SPECIALTIES AND EXIT SIGNAGE
<br />FE FIRE EXTINGUISHER
<br />W (BUSINESS)
<br />CEILING / WALL MTD. EXIT SIGN
<br />"74" (FACTORY INDUSTRIAL- I I (ARROWS = EXIT DIRECTION
<br />MODERATE HAZARD) (HATCH = FACE OF SIGN)
<br />7-2" (FACTORY INDUSTRIAL EGRESS AREAS
<br />LOW HAZARD)
<br />;F EXISTING AREAS NOT IN PROJECT
<br />SCOPE; EGRESS PATHS UN-
<br />"H 1" (HIGH HAZARD- DETONATION AFFECTED AND UNVERIFIED BY CRB
<br />L/VJ E INQ /YIICnJ IVV 1 IIV rRVJGV 1
<br />"H-2" (HIGH HAZARD- DEFLAGRATION) �./,!` SCOPE; EGRESS PATHS AFFECTED
<br />' ;.' �, BY PROJECT
<br />"H-3" (HIGH HAZARD- COMBUSTIBLES) AREAS IN PROJECT SCOPE
<br />"H-4" (HIGH HAZARD- HEALTH)
<br />"H-5" (HIGH HAZARD- PRODUCTION
<br />MATERIALS)
<br />"L" (LABORATORIES)
<br />"M" (MERCANTILE)
<br />"S-1" (STORAGE- MODERATE HAZARD)
<br />O O O O O O O
<br />O "S-2" (STORAGE- LOW HAZARD)
<br />"U" (UTILITY / MISCELLANEOUS)
<br />MATERIALS LEGEND
<br />CUT PATTERN SURFACE
<br />PATTERN
<br />d" CONC-1
<br />RES-1
<br />fx
<br />E
<br />i
<br />FINISH PLAN LEGEND
<br />ROOM FINISH TAG
<br />ROOM NAME
<br />ROOM NUMBER
<br />PRIMARY WALL FINISH
<br />PRIMARY WALL BASE
<br />PRIMARY FLOOR FINISH
<br />SEQUENTIAL FINISH TYPE FOR
<br />EACH FINISH NAME
<br />__._.._.__._._._!I...._......._....._. CMU
<br />(UNIT SIZE AS SPECIFIED) FINISH NAME DESIGNATION
<br />' --' INDICATES NEW WORK
<br />BRICK BUT NO FINISH
<br />'(E)' INDICATES EXISTING
<br />:- s�`— (UNIT SIZE AS SPECIFIED) FINISH TO REMAIN; 'PATCH TO
<br />.: _:_:_
<br />MATCH' AS REQUIRED
<br />STONE
<br />SECONDARY FINISH TAGS
<br />SIZE/ TYPE AS SPECIFIED
<br />xx
<br />-1 SECONDARY CEILING, WALL,
<br />BASE, FLOOR, AND/OR (OTHER)
<br />%{ r� STEEL FINISH DESIGNATION
<br />INDICATES EXTENTS OF
<br />SECONDARY FINISH
<br />ALUMINUM
<br />FINISH WOOD-
<br />PLANKS/BOARDS
<br />(SIZE/ TYPE AS SPECIFIED)
<br />....'... ,... .... r ... . •'
<br />1
<br />i t
<br />FINISH WOOD - PANELS
<br />(SIZE/ TYPE AS SPECIFIED
<br />J1t
<br />N/A
<br />ROUGH WOOD - PLYWOOD
<br />N/A PLASTIC
<br />NIA INSULATION - RIGID
<br />1 I---
<br />`
<br />"} '
<br />N/A INSULATION - SPRAY
<br />� ! YY
<br />N/A INSULATION - BATT
<br />N/A
<br />„X ri GLASS / GLAZING
<br />GYPSUM
<br />WALLBOARD (GWB)
<br />' --
<br />7-1
<br />N/A EARTH
<br />GRAVEL / STONE FILL
<br />l��
<br />t-CG-X CORNER GUARD SYMBOL AND
<br />- DESIGNATION
<br />BG-X BUMPER GUARD SYMBOL AND
<br />DESIGNATION
<br />FLOORING TRANSITION LINE
<br />ARCHITECTURAL SYMBOLS
<br />DOORS, WINDOWS, AND PARTITIONS
<br />i
<br />i
<br />i
<br />■
<br />EXISTING SWINGING DOOR -
<br />45 DEGREE ANGLE
<br />DOOR NUMBER TAG
<br />NEW SWINGING DOOR - 90
<br />DEGREE ANGLE
<br />DOUBLE SWINGING DOOR -
<br />INACTIVE LEAF
<br />DOUBLE SWINGING DOOR -
<br />ACTIVE LEAF
<br />INTERIOR WINDOW - NON -FLUSH
<br />INTERIOR WINDOW TAG
<br />INTERIOR WINDOW - FLUSH
<br />EXTERIOR CURTAINWALL
<br />.\
<br />vv\ uvvu/ EXTERIOR WINDOW TAG
<br />INTERIOR PARTITION TAG
<br />SAFETY AND FIRE EQUIPMENT
<br />A: I
<br />'s EMERGENCY SHOWER
<br />(FREE-STANDING)
<br />EMERGENCY SHOWER / EYEWASH
<br />(FREE-STANDING)
<br />.r
<br />O
<br />RECESSED EYEWASH/EMERGENCY
<br />SHOWER ACTUATOR WITH CEILING
<br />=11 `
<br />MOUNTED SHOWER HEAD
<br />I RECESSED EYEWASH/EMERGENCY
<br />I h `" SHOWER ACTUATOR WITH WALL
<br />MOUNTED SHOWER HEAD
<br />FIRE EXTINGUISHER CABINET
<br />(SURFACE MOUNTED)
<br />{
<br />FIRE EXTINGUISHER CABINET
<br />k
<br />(SEMI-RECESSED)
<br />FIRE EXTINGUISHER CABINET
<br />(FULLY -RECESSED)
<br />1="
<br />O
<br />FIRE EXTINGUISHER
<br />(WALL MOUNTED)
<br />MISCELLANEOUS
<br />SOLID LINE'X' INDICATES EXTENT OF
<br />OPENING IN FLOOR / ROOF BELOW
<br />_ DASHED LINE'X' INDICATES EXTENT
<br />' OF OPENING IN CEILING / FLOOR/
<br />' ROOF ABOVE
<br />X" =1'-0" SPOT ROOF/FLOOR SLAB SLOPE
<br />INDICATOR
<br />(PLAN) PARTITION LEGEND
<br />EXISTING WORK NEW WORK
<br />CONCRETE
<br />(2-HR RATED)
<br />GWB (1-HR RATED)
<br />ANTLIRM
<br />GWB (2-HR RATED)
<br />_^
<br />GWB (3-HR RATED)
<br />INSULATED WALL PANEL
<br />v--
<br />(NON RATED)
<br />-- - ----
<br />INSULATED WALL PANEL
<br />1-HR RATED)
<br />INSULATED WALL PANEL
<br />(2-HR RATED)
<br />-
<br />INSULATED WALL PANEL
<br />�- - -
<br />(3-HR RATED)
<br />_._ ------
<br />CONCRETE
<br />(NON RATED)
<br />CONCRETE
<br />(1-HR RATED)
<br />CONCRETE
<br />(3-HR RATED)
<br />CONCRETE
<br />(4-HR RATED)
<br />- - --
<br />MASONRY
<br />(NON RATED)
<br />SONRY
<br />(1AHR RATED)
<br />MASONRY
<br />(2-HR RATED)
<br />MASONRY
<br />(3-HR RATED)
<br />MASONRY
<br />(4-HR RATED)
<br />CLEAN ROOM
<br />(NON -RATED)
<br />METAL LINK FENCE
<br />FRAMELESS
<br />GLASS WALL
<br />GLASS STOREFRONT
<br />SYSTEM
<br />GLASS CURTAINWALL
<br />SYSTEM
<br />GENERAL SYMBOLS LEGEND
<br />COLUMN LINE REFERENCE
<br />COLUMN LINE DESIGNATION
<br />COLUMN GRID LINE
<br />SHEET NOTE REFERENCE
<br />SHEET NOTE
<br />i/ `-' SEE NOTE LEGEND ON SAME SHEET
<br />BUILDING SECTION REFERENCE
<br />ARROW AND TAIL INDICATE
<br />DIRECTION OF VIEW
<br /># SECTION NUMBER
<br />X00-00 SHEET WHERE SECTION
<br />IS DRAWN, SAME DISCIPLINE
<br />WALL SECTION REFERENCE
<br />SECTION NUMBER
<br />XXX -� WALL SECTION REFERENCE TYPE
<br /># (WHERE APPLICABLE)*
<br />X00-00 SHEET WHERE SECTION
<br />IS DRAWN, SAME DISCIPLINE
<br />DRAWING REVISION
<br />1 REVISION NUMBER (SEE
<br />DESCRIPTION IN TITLE BLOCK
<br />SAME SHEET)
<br />REVISION AREA
<br />EQUIPMENT TAG
<br />.1-TAG ID
<br />ROOM 1 SPACE NAME
<br />ROOM NAME ROOM NAME
<br />101 ROOM NUMBER
<br />150 SF ROOM AREA (OPTIONAL)
<br />METRIC ROOM AREA
<br />(OPTIONAL)
<br />NORTH ARROW
<br />INDICATES DIRECTION
<br />OF TRUE NORTH
<br />N INDICATES DIRECTION
<br />OF PROJECT NORTH
<br />DETAIL REFERENCE LEVEL
<br />DETAIL NUMBER
<br />XXX — DETAIL REFERENCE TYPE - - - - — - - - _ LEVEL NAME (�
<br />(WHERE APPLICABLE)* 0-0"
<br />X00-00 SHEET WHERE DETAIL
<br />IS DRAWN, SAME DISCIPLINE PLAN ELEVATION MARKER
<br />CALLOUT
<br />_ DETAIL NUMBER
<br />XXX— CALLOUT REFERENCE TYPE
<br /># (WHERE APPLICABLE)*
<br />X00-00 SHEET WHERE DETAIL
<br />- J IS DRAWN, SAME DISCIPLINE
<br />EXTERIOR ELEVATION REFERENCE
<br /># ELEVATION NUMBER
<br />XA(E==
<br />00-00 SHEET WHERE ELEVATION
<br />IS DRAWN, SAME DISCIPLINE
<br />INTERIOR ELEVATION REFERENCE (SINGLE AND MULTIPLE)
<br />ELEVATION NUMBER
<br /># XXX # XXX
<br /># # ELEVATION REFERENCE TYPE
<br /># X00-00 (WHERE APPLICABLE)"
<br />X00-00 SHEET WHERE ELEVATION IS
<br />DRAWN, SAME DISCIPLINE
<br />* REFERENCE TYPES (SECTION I DETAIL I CALLOUT I ELEVATION)
<br />OPP"= (OPPOSITE) IDENTICAL TO REFERENCED VIEW EXCEPT
<br />OPPOSITE ORIENTATION
<br />SIM = (SIMILAR) DOCUMENTED SCOPE IS IDENTICAL TO
<br />REFERENCED VIEW, WITH MINOR DIFFERENCES IN
<br />CONTEXTUAL ELEMENTS
<br />TYP = (TYPICAL) REFERENCED VIEW DOCUMENTS A
<br />REPEATED CONDITION
<br />MATCH LINE
<br />MATCHLINE
<br />RE:X00-00
<br />BREAK LINE
<br />PROJECT NOTES
<br />+/- 4' - 0" HEIGHT ABOVE / BELOW
<br />ESTABLISHED 0.0 ELEVATION
<br />(LEADER OPTIONAL)
<br />DEMOLITION LINEWORK
<br />OBJECT TO BE REMOVED
<br />EXISTING I DEMOLITION EXTENTS
<br />DEMOLITION EXTENT SYMBOL
<br />�# NUMBER DESIGNATION (OPTIONAL)
<br />~- CONNECTION TO EXISTING SYMBOL
<br />DIMENSIONS
<br />(E) INDICATES A REFERENCE ONLY -
<br />DIMENSION BETWEEN TWO
<br />EXISTING POINTS. (+/-) INDICATE
<br />NEW WORK DIMENSIONED TO AN
<br />EXISTING POINT. CONTRACTOR
<br />SHALL FIELD VERIFY AND NOTIFY
<br />ARCHITECT/ENGINEER OF ANY
<br />DISCREPANCIES
<br />INDICATES DIMENSION IS TO
<br />CENTERLINE OF OBJECT
<br />+/- X' -XI X' X" SET DIMENSIONS
<br />(NON +/- DIMENSIONS)
<br />COORD HOLD
<br />'HOLD' INDICATES
<br />CRITICAL DIMENSION
<br />COORD' INDICATES CONTRACTOR
<br />MUST VERIFY DIMENSION WITH
<br />FINAL APPROVED EQUIPMENT
<br />ALIGN
<br />INDICATES ALIGNMENT OF
<br />FINISHED FACE OF TWO ELEMENTS
<br />1. SITE VISIT & EXISTING CONDITIONS: 9. UTILITIES:
<br />THE CONTRACTOR SHALL VISIT THE SITE. THE VARIOUS PLANS THE LOCATION SHOWN FOR EXISTING UTILITY MAINS ARE
<br />ARE NOT INTENDED AS SURVEYS OF EXISTING CONDITIONS AND APPROXIMATE ONLY. THE ACCURACY OR COMPLETENESS OF THIS
<br />ONLY INDICATE IN GENERAL CERTAIN CONDITIONS RELATED TO INFORMATION IS NOT GUARANTEED. VERIFY LOCATION OF ALL
<br />THE WORK TO BE DONE, INFORMATION REGARDING EXISTING UTILITY LINES, CONDUITS, SURFACE OR SUBSURFACE
<br />CONDITIONS HAS BEEN DETERMINED AS REASONABLY AS STRUCTURES, ETC., OF ANY NATURE THAT MAY BE AFFECTED BY
<br />POSSIBLE, BUT MAY NOT BE SHOWN EXACTLY. CONTRACTOR THE WORK. VERIFY ACTUAL LOCATION AND DEPTH AND REPORT
<br />SHALL FAMILIARIZE THEMSELVES WITH AND VERIFY EXISTING POTENTIAL CONFLICTS TO THE ENGINEER PRIOR TO EXCAVATING
<br />CONDITIONS AND REPORT ALL DISCREPANCIES TO THE FOR NEW FACILITIES.
<br />ARCHITECT PRIOR TO THE START OF WORK.
<br />10. DAMAGED UTILITIES / SYSTEMS:
<br />2. CODE COMPLIANCE: SHOULD ANY OF THE ABOVE ITEMS BE DISTURBED,
<br />ALL WORK SHALL CONFORM WITH THE CURRENT APPLICABLE DISCONNECTED, OR DAMAGED DURING CONSTRUCTION, THE
<br />EDITIONS OF THE CODE, THE RULES AND REGULATIONS OF THE CONTRACTOR SHALL IMMEDIATELY NOTIFY PROPER AUTHORITIES
<br />SAFETY ORDERS ISSUED BY THE DIVISION OF INDUSTRIAL SAFETY AND THOSE PARTIES AFFECTED. CONTRACTOR SHALL BEAR ALL
<br />AND THE NATIONAL BOARD OF UNDERWRITERS. THE EXPENSES, OF WHATEVER NATURE, ARISING FROM SUCH
<br />CONTRACTOR SHALL COMPLY WITH THESE AND ALL OTHER DISTURBANCE, REPLACEMENT, OR REPAIR THEREOF, AND
<br />NATIONAL, STATE AND LOCAL CODES. WHERE UL OR GYPSUM REPLACE OR REPAIR SUCH ITEMS AS REQUIRED.
<br />ASSOCIATION CONSTRUCTION ASSEMBLIES ARE DESIGNATED,
<br />THE COMPONENTS AND INSTALLATION DETAILS SHALL CONFORM 11. UNIDENTIFIED ITEMS:
<br />IN EVERY PARTICULAR WITH THE DESIGN NUMBER SPECIFIED. SHOULD ANY UNIDENTIFIED ITEM BE ENCOUNTERED DURING
<br />DEMOLITION OR CONSTRUCTION, DO NOT PROCEED UNTIL THE
<br />3. SCHEDULE OF WORK: OWNER HAS BEEN NOTIFIED AND DIRECTION HAS BEEN GIVEN.
<br />COORDINATE THE CONSTRUCTION SCHEDULE AND OPERATIONS
<br />SCHEDULE WITH THE CONSTRUCTION COORDINATOR. WORK 12. TRENCHING:
<br />SHALL BE CONSTRUCTED IN PHASES AS REQUIRED TO ALL TRENCHES AND EXCAVATIONS SHALL BE CONSTRUCTED IN
<br />ACCOMMODATE OWNER'S REQUIREMENTS, STRICT COMPLIANCE WITH THE APPLICABLE SECTIONS OF STATE
<br />AND FEDERAL OSHA REQUIREMENTS AND OTHER APPLICABLE
<br />4. MASTER CONSTRUCTION SCHEDULE: SAFETY ORDINANCES. CONTRACTOR SHALL BEAR FULL
<br />THE CONTRACTOR SHALL PROVIDE A "MASTER CONSTRUCTION RESPONSIBILITY FOR TRENCH SHORING DESIGN AND
<br />SCHEDULE." INSTALLATION.
<br />5. "AS -BUILT" CONSTRUCTION SET: 13, DUST CONTROL:
<br />THE CONTRACTOR SHALL POSSESS AND MAINTAIN, AT THE JOB CONTRACTOR SHALL PROVIDE DUST CONTROL AT ALL TIMES.
<br />SITE, A CURRENT "AS -BUILT" DRAWING SET. THIS SET SHOULD
<br />REFLECT ALL APPROVED DESIGN DRAWING CHANGES. THIS SET IS 14. PATCH / PAINT I FINISHES:
<br />TO BE KEPT IN GOOD CONDITION AND SHALL BE DELIVERED TO ALL ADJACENT EXISTING FINISHES DAMAGED OR AFFECTED BY
<br />OWNER WITHIN TWO WEEKS AFTER THE COMPLETION OF THE DEMOLITION OR CONSTRUCTION OF NEW AREAS IN SCOPE OF
<br />PROJECT. WORK SHALL BE PATCHED AND REPAIRED TO MEET OWNER
<br />SATISFACTION.
<br />6. SEISMIC BRACING:
<br />ALL NEW CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH 15. MECHANICAL & ELECTRICAL EQUIPMENT:
<br />IBC EARTHQUAKE RESISTANT DESIGN, CONSTRUCTION ALL MECHANICAL & ELECTRICAL EQUIPMENT SHALL HAVE A UL
<br />STANDARDS, AND SPECIFICATIONS FOR SEISMIC BRACING AND DESIGN LISTING/NUMBER. ANY EQUIPMENT NOT LISTED WILL BE
<br />SUPPORT OF ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL, REQUIRED TO BE FIELD TESTED AND CERTIFIED BY AN APPROVED
<br />PIPING, AND ELECTRICAL WORK. PROVIDE SEISMIC ANCHORS AT AGENCY.
<br />ALL EQUIPMENT, BENCHES, AND SHELVES.
<br />16. DEMOLITION COORDINATION:
<br />7. MATERIALS AND METHODS: COORDINATE ALL DEMOLITION ON PLANS WITH ARCHITECTURAL,
<br />ALL MATERIALS FOR THIS CONSTRUCTION SHALL BE NEW, UNO. MECHANICAL, PROCESS PIPING, PLUMBING, ELECTRICAL, AND
<br />OWNER RESERVES THE RIGHT TO APPROVE ALL MATERIALS, STRUCTURAL DRAWINGS. DEMOLISH AS REQUIRED TO SUPPORT
<br />WHICH SHALL BE IN STRICT ACCORDANCE WITH OWNER NEW WORK.
<br />SPECIFICATIONS OR AS NOTED ON THE CONSTRUCTION
<br />DOCUMENTS. IF ANY PORTION OF THE WORK (EITHER THE 17. IRRIGATION:
<br />MATERIALS OR THE METHODS OF INSTALLATION) IS DETERMINED ALL LANDSCAPING AND IRRIGATION DISTURBED BY
<br />TO BE DEFECTIVE, THE CONTRACTOR SHALL REPLACE THAT IMPROVEMENTS SHALL BE REPAIRED OR REPLACED BY
<br />PORTION, WITH NO ADDITIONAL COST TO OWNER, AS PART OF CONTRACTOR WITHOUT ADDED COST TO THE OWNER.
<br />THE ORIGINAL CONTRACT.
<br />18. ACCESS DOORS:
<br />8. APPLICABLE FEES AND PERMITS: COORDINATE ACCESS DOOR LOCATIONS (FOR CONCEALED ITEMS)
<br />OWNER WILL PAY FOR THE BUILDING PERMIT AND THE GENERAL WITH APPROPRIATE CONTRACTOR,
<br />CONTRACTOR WILL OBTAIN IT. IT IS THE RESPONSIBILITY OF THE
<br />CONTRACTOR TO OBTAIN AND PAY FOR ALL TRADE PERMITS, 19. DAMAGED FIREPROOFING:
<br />MISCELLANEOUS FEES, INSPECTIONS, AND TAXES. REPLACE DAMAGED FIREPROOFING AT DECKS, COLUMNS, AND
<br />BEAMS TO RETAIN EXISTING FIRE RATING.
<br />ARCHITECTURAL LEAD SHEET CONTENT IS GENERAL IN NATURE. NOT
<br />ALL SYMBOLOGY, LEGEND ELEMENTS, AND ABBREVIATIONS SHOWN ON
<br />THIS SHEET ARE USED, AND THEIR INCLUSION ON THIS SHEET IS NOT
<br />AN INDICATOR AS TO WHETHER OR NOT THEY ARE RELEVANT TO
<br />SPECIFIC PROJECT SCOPES.
<br />CONSULTING ARCHITECT/ENGINEER
<br />I CLARK, RICHARDSON AND BISKUP
<br />CONSULTING ENGINEERS, INC.
<br />C � CRB ARCHITECTS -ENGINEERS P.C.
<br />1 GLENLAKE PARKWAY
<br />SUITE 600
<br />\ ATLANTA, GA 30328
<br />PHONE: 404-860-1440
<br />FAX: 404-860-1442
<br />PROJECT TITLE
<br />ZEPHYRHILLS LINE 12
<br />REV
<br />ARCHITECTURAL LEAD SHEET CONTENT IS GENERAL IN NATURE. NOT
<br />ALL SYMBOLOGY, LEGEND ELEMENTS, AND ABBREVIATIONS SHOWN ON
<br />THIS SHEET ARE USED, AND THEIR INCLUSION ON THIS SHEET IS NOT
<br />AN INDICATOR AS TO WHETHER OR NOT THEY ARE RELEVANT TO
<br />SPECIFIC PROJECT SCOPES.
<br />CONSULTING ARCHITECT/ENGINEER
<br />I CLARK, RICHARDSON AND BISKUP
<br />CONSULTING ENGINEERS, INC.
<br />C � CRB ARCHITECTS -ENGINEERS P.C.
<br />1 GLENLAKE PARKWAY
<br />SUITE 600
<br />\ ATLANTA, GA 30328
<br />PHONE: 404-860-1440
<br />FAX: 404-860-1442
<br />PROJECT TITLE
<br />ZEPHYRHILLS LINE 12
<br />REV
<br />BY
<br />DATE
<br />DESCRIPTION
<br />0
<br />RJP
<br />25AUG21
<br />ISSUED FORBID
<br />1
<br />RJP
<br />22SEP21
<br />ISSUED FOR PERMIT
<br />LICENSEE
<br />F FLQ
<br />..r. w
<br />. 1
<br />RED
<br />CRB ARCHITECTS -ENGINEERS P.C. LICENSE #09000002537
<br />CRB CONSULTING ENGINEERS, INC LICENSE #F96000003389
<br />INFORMATION CONTAINED HEREIN IS CONSIDERED CONFIDENTIAL. THIS
<br />DOCUMENT IS NOT TO BE USED, REPRODUCED, OR DISCLOSED IN WHOLE OR
<br />PART WITHOUT THE PRIOR WRITTEN PERMISSION OF BLUETRITON BRANDS.
<br />PROJ. NO.
<br />217043.00
<br />DESIGNED BY:
<br />AP
<br />SCALE:
<br />NOT TO SCALE
<br />CHECKED BY:
<br />RJP
<br />SHEET SIZE:
<br />30x42
<br />APPROVED BY:
<br />RJP
<br />'DRAWING TITLE
<br />ARCHITECTURAL
<br />LEAD SHEET
<br />'DRAWING NUMBER
<br />AOO-01
<br />
|