Laserfiche WebLink
� GENERAL NOTES <br />ACCESSIBILITY LEGEND EGRESS PLAN LEGEND <br />ACCESSIBLE ROUTE OCCUPANT LOAD TAG <br />MIN. 4'-0" WIDE WALKWAY, MAX. 1:20 ROOM NAME ROOM NAME <br />SLOPE. XXX ROOM NUMBER <br />### <br />ROOM OCCUPANCY <br />PATH OF TRAVEL SYMBOLOGY <br />TRAVEL DISTANCE START POINT <br />I <br />COMMON PATH TRAVEL DISTANCE <br />of EXIT ACCESS TRAVEL DISTANCE <br />�I N (INCLUDES COMMON PATH <br />TRAVEL DISTANCE) <br />�] COMMON PATH OF TRAVEL <br />i END OF COMMON PATH OF TRAVEL <br />I <br />EXIT ACCESS PATH OF TRAVEL <br />EXIT ACCESS POINT <br />EXIT DOOR OCCUPANT LOAD TAG <br />- DIRECTION OF EXIT TRAVEL <br />EXIT NO. EXIT REFERENCE NUMBER <br />### ACTUAL OCCUPANT LOAD AT DOOR <br />OCCUPANCYUSE # �# MAXIMUM OCCUPANT LOAD OF <br />GROUP LEGEND DOOR <br />INTERIOR DOOR OCCUPANT LOAD TAG <br />"A 1" (ASSEMBLY) ® OCCUPANT LOAD AT DOOR <br />' DIRECTION OF EXIT TRAVEL <br />W3" (ASSEMBLY- GENERAL / <br />MISCELLANEOUS) FIRE SPECIALTIES AND EXIT SIGNAGE <br />FE FIRE EXTINGUISHER <br />W (BUSINESS) <br />CEILING / WALL MTD. EXIT SIGN <br />"74" (FACTORY INDUSTRIAL- I I (ARROWS = EXIT DIRECTION <br />MODERATE HAZARD) (HATCH = FACE OF SIGN) <br />7-2" (FACTORY INDUSTRIAL EGRESS AREAS <br />LOW HAZARD) <br />;F EXISTING AREAS NOT IN PROJECT <br />SCOPE; EGRESS PATHS UN- <br />"H 1" (HIGH HAZARD- DETONATION AFFECTED AND UNVERIFIED BY CRB <br />L/VJ E INQ /YIICnJ IVV 1 IIV rRVJGV 1 <br />"H-2" (HIGH HAZARD- DEFLAGRATION) �./,!` SCOPE; EGRESS PATHS AFFECTED <br />' ;.' �, BY PROJECT <br />"H-3" (HIGH HAZARD- COMBUSTIBLES) AREAS IN PROJECT SCOPE <br />"H-4" (HIGH HAZARD- HEALTH) <br />"H-5" (HIGH HAZARD- PRODUCTION <br />MATERIALS) <br />"L" (LABORATORIES) <br />"M" (MERCANTILE) <br />"S-1" (STORAGE- MODERATE HAZARD) <br />O O O O O O O <br />O "S-2" (STORAGE- LOW HAZARD) <br />"U" (UTILITY / MISCELLANEOUS) <br />MATERIALS LEGEND <br />CUT PATTERN SURFACE <br />PATTERN <br />d" CONC-1 <br />RES-1 <br />fx <br />E <br />i <br />FINISH PLAN LEGEND <br />ROOM FINISH TAG <br />ROOM NAME <br />ROOM NUMBER <br />PRIMARY WALL FINISH <br />PRIMARY WALL BASE <br />PRIMARY FLOOR FINISH <br />SEQUENTIAL FINISH TYPE FOR <br />EACH FINISH NAME <br />__._.._.__._._._!I...._......._....._. CMU <br />(UNIT SIZE AS SPECIFIED) FINISH NAME DESIGNATION <br />' --' INDICATES NEW WORK <br />BRICK BUT NO FINISH <br />'(E)' INDICATES EXISTING <br />:- s�`— (UNIT SIZE AS SPECIFIED) FINISH TO REMAIN; 'PATCH TO <br />.: _:_:_ <br />MATCH' AS REQUIRED <br />STONE <br />SECONDARY FINISH TAGS <br />SIZE/ TYPE AS SPECIFIED <br />xx <br />-1 SECONDARY CEILING, WALL, <br />BASE, FLOOR, AND/OR (OTHER) <br />%{ r� STEEL FINISH DESIGNATION <br />INDICATES EXTENTS OF <br />SECONDARY FINISH <br />ALUMINUM <br />FINISH WOOD- <br />PLANKS/BOARDS <br />(SIZE/ TYPE AS SPECIFIED) <br />....'... ,... .... r ... . •' <br />1 <br />i t <br />FINISH WOOD - PANELS <br />(SIZE/ TYPE AS SPECIFIED <br />J1t <br />N/A <br />ROUGH WOOD - PLYWOOD <br />N/A PLASTIC <br />NIA INSULATION - RIGID <br />1 I--- <br />` <br />"} ' <br />N/A INSULATION - SPRAY <br />� ! YY <br />N/A INSULATION - BATT <br />N/A <br />„X ri GLASS / GLAZING <br />GYPSUM <br />WALLBOARD (GWB) <br />' -- <br />7-1 <br />N/A EARTH <br />GRAVEL / STONE FILL <br />l�� <br />t-CG-X CORNER GUARD SYMBOL AND <br />- DESIGNATION <br />BG-X BUMPER GUARD SYMBOL AND <br />DESIGNATION <br />FLOORING TRANSITION LINE <br />ARCHITECTURAL SYMBOLS <br />DOORS, WINDOWS, AND PARTITIONS <br />i <br />i <br />i <br />■ <br />EXISTING SWINGING DOOR - <br />45 DEGREE ANGLE <br />DOOR NUMBER TAG <br />NEW SWINGING DOOR - 90 <br />DEGREE ANGLE <br />DOUBLE SWINGING DOOR - <br />INACTIVE LEAF <br />DOUBLE SWINGING DOOR - <br />ACTIVE LEAF <br />INTERIOR WINDOW - NON -FLUSH <br />INTERIOR WINDOW TAG <br />INTERIOR WINDOW - FLUSH <br />EXTERIOR CURTAINWALL <br />.\ <br />vv\ uvvu/ EXTERIOR WINDOW TAG <br />INTERIOR PARTITION TAG <br />SAFETY AND FIRE EQUIPMENT <br />A: I <br />'s EMERGENCY SHOWER <br />(FREE-STANDING) <br />EMERGENCY SHOWER / EYEWASH <br />(FREE-STANDING) <br />.r <br />O <br />RECESSED EYEWASH/EMERGENCY <br />SHOWER ACTUATOR WITH CEILING <br />=11 ` <br />MOUNTED SHOWER HEAD <br />I RECESSED EYEWASH/EMERGENCY <br />I h `" SHOWER ACTUATOR WITH WALL <br />MOUNTED SHOWER HEAD <br />FIRE EXTINGUISHER CABINET <br />(SURFACE MOUNTED) <br />{ <br />FIRE EXTINGUISHER CABINET <br />k <br />(SEMI-RECESSED) <br />FIRE EXTINGUISHER CABINET <br />(FULLY -RECESSED) <br />1=" <br />O <br />FIRE EXTINGUISHER <br />(WALL MOUNTED) <br />MISCELLANEOUS <br />SOLID LINE'X' INDICATES EXTENT OF <br />OPENING IN FLOOR / ROOF BELOW <br />_ DASHED LINE'X' INDICATES EXTENT <br />' OF OPENING IN CEILING / FLOOR/ <br />' ROOF ABOVE <br />X" =1'-0" SPOT ROOF/FLOOR SLAB SLOPE <br />INDICATOR <br />(PLAN) PARTITION LEGEND <br />EXISTING WORK NEW WORK <br />CONCRETE <br />(2-HR RATED) <br />GWB (1-HR RATED) <br />ANTLIRM <br />GWB (2-HR RATED) <br />_^ <br />GWB (3-HR RATED) <br />INSULATED WALL PANEL <br />v-- <br />(NON RATED) <br />-- - ---- <br />INSULATED WALL PANEL <br />1-HR RATED) <br />INSULATED WALL PANEL <br />(2-HR RATED) <br />- <br />INSULATED WALL PANEL <br />�- - - <br />(3-HR RATED) <br />_._ ------ <br />CONCRETE <br />(NON RATED) <br />CONCRETE <br />(1-HR RATED) <br />CONCRETE <br />(3-HR RATED) <br />CONCRETE <br />(4-HR RATED) <br />- - -- <br />MASONRY <br />(NON RATED) <br />SONRY <br />(1AHR RATED) <br />MASONRY <br />(2-HR RATED) <br />MASONRY <br />(3-HR RATED) <br />MASONRY <br />(4-HR RATED) <br />CLEAN ROOM <br />(NON -RATED) <br />METAL LINK FENCE <br />FRAMELESS <br />GLASS WALL <br />GLASS STOREFRONT <br />SYSTEM <br />GLASS CURTAINWALL <br />SYSTEM <br />GENERAL SYMBOLS LEGEND <br />COLUMN LINE REFERENCE <br />COLUMN LINE DESIGNATION <br />COLUMN GRID LINE <br />SHEET NOTE REFERENCE <br />SHEET NOTE <br />i/ `-' SEE NOTE LEGEND ON SAME SHEET <br />BUILDING SECTION REFERENCE <br />ARROW AND TAIL INDICATE <br />DIRECTION OF VIEW <br /># SECTION NUMBER <br />X00-00 SHEET WHERE SECTION <br />IS DRAWN, SAME DISCIPLINE <br />WALL SECTION REFERENCE <br />SECTION NUMBER <br />XXX -� WALL SECTION REFERENCE TYPE <br /># (WHERE APPLICABLE)* <br />X00-00 SHEET WHERE SECTION <br />IS DRAWN, SAME DISCIPLINE <br />DRAWING REVISION <br />1 REVISION NUMBER (SEE <br />DESCRIPTION IN TITLE BLOCK <br />SAME SHEET) <br />REVISION AREA <br />EQUIPMENT TAG <br />.1-TAG ID <br />ROOM 1 SPACE NAME <br />ROOM NAME ROOM NAME <br />101 ROOM NUMBER <br />150 SF ROOM AREA (OPTIONAL) <br />METRIC ROOM AREA <br />(OPTIONAL) <br />NORTH ARROW <br />INDICATES DIRECTION <br />OF TRUE NORTH <br />N INDICATES DIRECTION <br />OF PROJECT NORTH <br />DETAIL REFERENCE LEVEL <br />DETAIL NUMBER <br />XXX — DETAIL REFERENCE TYPE - - - - — - - - _ LEVEL NAME (� <br />(WHERE APPLICABLE)* 0-0" <br />X00-00 SHEET WHERE DETAIL <br />IS DRAWN, SAME DISCIPLINE PLAN ELEVATION MARKER <br />CALLOUT <br />_ DETAIL NUMBER <br />XXX— CALLOUT REFERENCE TYPE <br /># (WHERE APPLICABLE)* <br />X00-00 SHEET WHERE DETAIL <br />- J IS DRAWN, SAME DISCIPLINE <br />EXTERIOR ELEVATION REFERENCE <br /># ELEVATION NUMBER <br />XA(E== <br />00-00 SHEET WHERE ELEVATION <br />IS DRAWN, SAME DISCIPLINE <br />INTERIOR ELEVATION REFERENCE (SINGLE AND MULTIPLE) <br />ELEVATION NUMBER <br /># XXX # XXX <br /># # ELEVATION REFERENCE TYPE <br /># X00-00 (WHERE APPLICABLE)" <br />X00-00 SHEET WHERE ELEVATION IS <br />DRAWN, SAME DISCIPLINE <br />* REFERENCE TYPES (SECTION I DETAIL I CALLOUT I ELEVATION) <br />OPP"= (OPPOSITE) IDENTICAL TO REFERENCED VIEW EXCEPT <br />OPPOSITE ORIENTATION <br />SIM = (SIMILAR) DOCUMENTED SCOPE IS IDENTICAL TO <br />REFERENCED VIEW, WITH MINOR DIFFERENCES IN <br />CONTEXTUAL ELEMENTS <br />TYP = (TYPICAL) REFERENCED VIEW DOCUMENTS A <br />REPEATED CONDITION <br />MATCH LINE <br />MATCHLINE <br />RE:X00-00 <br />BREAK LINE <br />PROJECT NOTES <br />+/- 4' - 0" HEIGHT ABOVE / BELOW <br />ESTABLISHED 0.0 ELEVATION <br />(LEADER OPTIONAL) <br />DEMOLITION LINEWORK <br />OBJECT TO BE REMOVED <br />EXISTING I DEMOLITION EXTENTS <br />DEMOLITION EXTENT SYMBOL <br />�# NUMBER DESIGNATION (OPTIONAL) <br />~- CONNECTION TO EXISTING SYMBOL <br />DIMENSIONS <br />(E) INDICATES A REFERENCE ONLY - <br />DIMENSION BETWEEN TWO <br />EXISTING POINTS. (+/-) INDICATE <br />NEW WORK DIMENSIONED TO AN <br />EXISTING POINT. CONTRACTOR <br />SHALL FIELD VERIFY AND NOTIFY <br />ARCHITECT/ENGINEER OF ANY <br />DISCREPANCIES <br />INDICATES DIMENSION IS TO <br />CENTERLINE OF OBJECT <br />+/- X' -XI X' X" SET DIMENSIONS <br />(NON +/- DIMENSIONS) <br />COORD HOLD <br />'HOLD' INDICATES <br />CRITICAL DIMENSION <br />COORD' INDICATES CONTRACTOR <br />MUST VERIFY DIMENSION WITH <br />FINAL APPROVED EQUIPMENT <br />ALIGN <br />INDICATES ALIGNMENT OF <br />FINISHED FACE OF TWO ELEMENTS <br />1. SITE VISIT & EXISTING CONDITIONS: 9. UTILITIES: <br />THE CONTRACTOR SHALL VISIT THE SITE. THE VARIOUS PLANS THE LOCATION SHOWN FOR EXISTING UTILITY MAINS ARE <br />ARE NOT INTENDED AS SURVEYS OF EXISTING CONDITIONS AND APPROXIMATE ONLY. THE ACCURACY OR COMPLETENESS OF THIS <br />ONLY INDICATE IN GENERAL CERTAIN CONDITIONS RELATED TO INFORMATION IS NOT GUARANTEED. VERIFY LOCATION OF ALL <br />THE WORK TO BE DONE, INFORMATION REGARDING EXISTING UTILITY LINES, CONDUITS, SURFACE OR SUBSURFACE <br />CONDITIONS HAS BEEN DETERMINED AS REASONABLY AS STRUCTURES, ETC., OF ANY NATURE THAT MAY BE AFFECTED BY <br />POSSIBLE, BUT MAY NOT BE SHOWN EXACTLY. CONTRACTOR THE WORK. VERIFY ACTUAL LOCATION AND DEPTH AND REPORT <br />SHALL FAMILIARIZE THEMSELVES WITH AND VERIFY EXISTING POTENTIAL CONFLICTS TO THE ENGINEER PRIOR TO EXCAVATING <br />CONDITIONS AND REPORT ALL DISCREPANCIES TO THE FOR NEW FACILITIES. <br />ARCHITECT PRIOR TO THE START OF WORK. <br />10. DAMAGED UTILITIES / SYSTEMS: <br />2. CODE COMPLIANCE: SHOULD ANY OF THE ABOVE ITEMS BE DISTURBED, <br />ALL WORK SHALL CONFORM WITH THE CURRENT APPLICABLE DISCONNECTED, OR DAMAGED DURING CONSTRUCTION, THE <br />EDITIONS OF THE CODE, THE RULES AND REGULATIONS OF THE CONTRACTOR SHALL IMMEDIATELY NOTIFY PROPER AUTHORITIES <br />SAFETY ORDERS ISSUED BY THE DIVISION OF INDUSTRIAL SAFETY AND THOSE PARTIES AFFECTED. CONTRACTOR SHALL BEAR ALL <br />AND THE NATIONAL BOARD OF UNDERWRITERS. THE EXPENSES, OF WHATEVER NATURE, ARISING FROM SUCH <br />CONTRACTOR SHALL COMPLY WITH THESE AND ALL OTHER DISTURBANCE, REPLACEMENT, OR REPAIR THEREOF, AND <br />NATIONAL, STATE AND LOCAL CODES. WHERE UL OR GYPSUM REPLACE OR REPAIR SUCH ITEMS AS REQUIRED. <br />ASSOCIATION CONSTRUCTION ASSEMBLIES ARE DESIGNATED, <br />THE COMPONENTS AND INSTALLATION DETAILS SHALL CONFORM 11. UNIDENTIFIED ITEMS: <br />IN EVERY PARTICULAR WITH THE DESIGN NUMBER SPECIFIED. SHOULD ANY UNIDENTIFIED ITEM BE ENCOUNTERED DURING <br />DEMOLITION OR CONSTRUCTION, DO NOT PROCEED UNTIL THE <br />3. SCHEDULE OF WORK: OWNER HAS BEEN NOTIFIED AND DIRECTION HAS BEEN GIVEN. <br />COORDINATE THE CONSTRUCTION SCHEDULE AND OPERATIONS <br />SCHEDULE WITH THE CONSTRUCTION COORDINATOR. WORK 12. TRENCHING: <br />SHALL BE CONSTRUCTED IN PHASES AS REQUIRED TO ALL TRENCHES AND EXCAVATIONS SHALL BE CONSTRUCTED IN <br />ACCOMMODATE OWNER'S REQUIREMENTS, STRICT COMPLIANCE WITH THE APPLICABLE SECTIONS OF STATE <br />AND FEDERAL OSHA REQUIREMENTS AND OTHER APPLICABLE <br />4. MASTER CONSTRUCTION SCHEDULE: SAFETY ORDINANCES. CONTRACTOR SHALL BEAR FULL <br />THE CONTRACTOR SHALL PROVIDE A "MASTER CONSTRUCTION RESPONSIBILITY FOR TRENCH SHORING DESIGN AND <br />SCHEDULE." INSTALLATION. <br />5. "AS -BUILT" CONSTRUCTION SET: 13, DUST CONTROL: <br />THE CONTRACTOR SHALL POSSESS AND MAINTAIN, AT THE JOB CONTRACTOR SHALL PROVIDE DUST CONTROL AT ALL TIMES. <br />SITE, A CURRENT "AS -BUILT" DRAWING SET. THIS SET SHOULD <br />REFLECT ALL APPROVED DESIGN DRAWING CHANGES. THIS SET IS 14. PATCH / PAINT I FINISHES: <br />TO BE KEPT IN GOOD CONDITION AND SHALL BE DELIVERED TO ALL ADJACENT EXISTING FINISHES DAMAGED OR AFFECTED BY <br />OWNER WITHIN TWO WEEKS AFTER THE COMPLETION OF THE DEMOLITION OR CONSTRUCTION OF NEW AREAS IN SCOPE OF <br />PROJECT. WORK SHALL BE PATCHED AND REPAIRED TO MEET OWNER <br />SATISFACTION. <br />6. SEISMIC BRACING: <br />ALL NEW CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH 15. MECHANICAL & ELECTRICAL EQUIPMENT: <br />IBC EARTHQUAKE RESISTANT DESIGN, CONSTRUCTION ALL MECHANICAL & ELECTRICAL EQUIPMENT SHALL HAVE A UL <br />STANDARDS, AND SPECIFICATIONS FOR SEISMIC BRACING AND DESIGN LISTING/NUMBER. ANY EQUIPMENT NOT LISTED WILL BE <br />SUPPORT OF ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL, REQUIRED TO BE FIELD TESTED AND CERTIFIED BY AN APPROVED <br />PIPING, AND ELECTRICAL WORK. PROVIDE SEISMIC ANCHORS AT AGENCY. <br />ALL EQUIPMENT, BENCHES, AND SHELVES. <br />16. DEMOLITION COORDINATION: <br />7. MATERIALS AND METHODS: COORDINATE ALL DEMOLITION ON PLANS WITH ARCHITECTURAL, <br />ALL MATERIALS FOR THIS CONSTRUCTION SHALL BE NEW, UNO. MECHANICAL, PROCESS PIPING, PLUMBING, ELECTRICAL, AND <br />OWNER RESERVES THE RIGHT TO APPROVE ALL MATERIALS, STRUCTURAL DRAWINGS. DEMOLISH AS REQUIRED TO SUPPORT <br />WHICH SHALL BE IN STRICT ACCORDANCE WITH OWNER NEW WORK. <br />SPECIFICATIONS OR AS NOTED ON THE CONSTRUCTION <br />DOCUMENTS. IF ANY PORTION OF THE WORK (EITHER THE 17. IRRIGATION: <br />MATERIALS OR THE METHODS OF INSTALLATION) IS DETERMINED ALL LANDSCAPING AND IRRIGATION DISTURBED BY <br />TO BE DEFECTIVE, THE CONTRACTOR SHALL REPLACE THAT IMPROVEMENTS SHALL BE REPAIRED OR REPLACED BY <br />PORTION, WITH NO ADDITIONAL COST TO OWNER, AS PART OF CONTRACTOR WITHOUT ADDED COST TO THE OWNER. <br />THE ORIGINAL CONTRACT. <br />18. ACCESS DOORS: <br />8. APPLICABLE FEES AND PERMITS: COORDINATE ACCESS DOOR LOCATIONS (FOR CONCEALED ITEMS) <br />OWNER WILL PAY FOR THE BUILDING PERMIT AND THE GENERAL WITH APPROPRIATE CONTRACTOR, <br />CONTRACTOR WILL OBTAIN IT. IT IS THE RESPONSIBILITY OF THE <br />CONTRACTOR TO OBTAIN AND PAY FOR ALL TRADE PERMITS, 19. DAMAGED FIREPROOFING: <br />MISCELLANEOUS FEES, INSPECTIONS, AND TAXES. REPLACE DAMAGED FIREPROOFING AT DECKS, COLUMNS, AND <br />BEAMS TO RETAIN EXISTING FIRE RATING. <br />ARCHITECTURAL LEAD SHEET CONTENT IS GENERAL IN NATURE. NOT <br />ALL SYMBOLOGY, LEGEND ELEMENTS, AND ABBREVIATIONS SHOWN ON <br />THIS SHEET ARE USED, AND THEIR INCLUSION ON THIS SHEET IS NOT <br />AN INDICATOR AS TO WHETHER OR NOT THEY ARE RELEVANT TO <br />SPECIFIC PROJECT SCOPES. <br />CONSULTING ARCHITECT/ENGINEER <br />I CLARK, RICHARDSON AND BISKUP <br />CONSULTING ENGINEERS, INC. <br />C � CRB ARCHITECTS -ENGINEERS P.C. <br />1 GLENLAKE PARKWAY <br />SUITE 600 <br />\ ATLANTA, GA 30328 <br />PHONE: 404-860-1440 <br />FAX: 404-860-1442 <br />PROJECT TITLE <br />ZEPHYRHILLS LINE 12 <br />REV <br />ARCHITECTURAL LEAD SHEET CONTENT IS GENERAL IN NATURE. NOT <br />ALL SYMBOLOGY, LEGEND ELEMENTS, AND ABBREVIATIONS SHOWN ON <br />THIS SHEET ARE USED, AND THEIR INCLUSION ON THIS SHEET IS NOT <br />AN INDICATOR AS TO WHETHER OR NOT THEY ARE RELEVANT TO <br />SPECIFIC PROJECT SCOPES. <br />CONSULTING ARCHITECT/ENGINEER <br />I CLARK, RICHARDSON AND BISKUP <br />CONSULTING ENGINEERS, INC. <br />C � CRB ARCHITECTS -ENGINEERS P.C. <br />1 GLENLAKE PARKWAY <br />SUITE 600 <br />\ ATLANTA, GA 30328 <br />PHONE: 404-860-1440 <br />FAX: 404-860-1442 <br />PROJECT TITLE <br />ZEPHYRHILLS LINE 12 <br />REV <br />BY <br />DATE <br />DESCRIPTION <br />0 <br />RJP <br />25AUG21 <br />ISSUED FORBID <br />1 <br />RJP <br />22SEP21 <br />ISSUED FOR PERMIT <br />LICENSEE <br />F FLQ <br />..r. w <br />. 1 <br />RED <br />CRB ARCHITECTS -ENGINEERS P.C. LICENSE #09000002537 <br />CRB CONSULTING ENGINEERS, INC LICENSE #F96000003389 <br />INFORMATION CONTAINED HEREIN IS CONSIDERED CONFIDENTIAL. THIS <br />DOCUMENT IS NOT TO BE USED, REPRODUCED, OR DISCLOSED IN WHOLE OR <br />PART WITHOUT THE PRIOR WRITTEN PERMISSION OF BLUETRITON BRANDS. <br />PROJ. NO. <br />217043.00 <br />DESIGNED BY: <br />AP <br />SCALE: <br />NOT TO SCALE <br />CHECKED BY: <br />RJP <br />SHEET SIZE: <br />30x42 <br />APPROVED BY: <br />RJP <br />'DRAWING TITLE <br />ARCHITECTURAL <br />LEAD SHEET <br />'DRAWING NUMBER <br />AOO-01 <br />