Laserfiche WebLink
W <br />t <br />a <br />n <br />0 <br />o- <br />a <br />J <br />LO <br />0 <br />0 <br />0 <br />c) <br />9 <br />0 <br />3 <br />Q <br />r— <br />d <br />a. <br />E <br />9 <br />cn <br />0 <br />0 <br />0 <br />c <br />'3 <br />v <br />0 <br />U <br />U <br />.a <br />a <br />0 <br />6 <br />0 <br />0 <br />0 <br />0- <br />9 <br />r` <br />N, <br />0 <br />a <br />m <br />d <br />0 <br />DOOR JAMB (REFERTO <br />DOOR JAMB (REFER <br />1x4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />PRODUCT <br />1x4 1/2" DRYWALL <br />TO PRODUCT <br />TO PRODUCT <br />FOR CONN. <br />/ <br />APPROVAL FOR CONN. <br />APPROVAL FOR CONN.APPROVAL <br />&X41"RYWALL <br />x4 P.T. <br />3/16"0 X 3" LONG <br />, <br />!x <br />FURRING <br />ROWS 3/16" 3-1/2" <br />1 X 4 <br />FURRING <br />3-1/4" LONG X 3116"0FURRING <br />TAPCONS <br />(2) x <br />INTO <br />STAGGERED @ 16" <br />TAPCON 16" O.C. & 4" <br />2X8 <br />BLOCON. <br />BLOCK@ SPACING „ <br />1 <br />DETAIL <br />O.C. 2-ROWS INTO <br />1x8 P.T. <br />FROM EACH END w/ MIN. <br />2" EDGE DIST. ATTACH <br />1X8 <br />PER MANUFACTURE <br />MASONRY THROUGH 1-1 /2" DETAIL <br />1x8 w/ (2) ROWS 8d NALS <br />�� <br />3 DETAIL <br />1x4 P.T. & 1x8 P.T. <br />STAGGERED @ 12" O.C. <br />3/16" x 3 -1/2" <br />1x4 P.T. <br />DOOR JAMB (REFER <br />TAPCON @ 16" <br />TO PRODUCT <br />O.C. & 4" FROM <br />DOOR JAMB (REFER <br />APPROVAL FOR CONN. <br />1x4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />EACH END W/ MIN. <br />2" EDGE DIST. <br />TO PRODUCT <br />APPROVAL FOR CONN. <br />j /% <br />2x8 P.T. w/ (2) ROWS 3/16" <br />TO PRODUCT <br />APPROVAL FOR CONN. <br />/ / <br />j! <br />(2) ROWS 3/16" x 3-1/2" <br />TAPCON @ 16" O.C. & <br />%�i// <br />x 3-1/2" TAPCON 16" <br />O.C. & 4" FROM ECH <br />END w/ MIN. 2" EDGE DIST. <br />1x4 <br />FURRINI <br />4" FROM EACH END w/ <br />2x8 P.T. <br />ATTACH SECOND PLY w/ <br />2x P.T. AS REQ'D <br />MIN. 2" EDGE DIST. <br />2x8" <br />2x DETAIL <br />2 1/4 " <br />DETAIL <br />STAGGERED @ 12" O.C. <br />3-1/4 DETAIL <br />BUILDOUT OVER SIZE DOOR -WINDOW ROUGH OPENINGS CC <br />SCALE: N.T.S. SS <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />EMBEDMENT INTO BLK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45' DIAGONAL (4)10d NAILS INTO <br />BRACE(S) 2 x 8 BRACE/ BLKG. <br />7/16" OSB <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) POLY -CELL IN THIS AREA <br />BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />INSTALL WDW. SCREW ANCHOR 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />INTO ARCH BLKG. PER ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 <br />INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW, INSTALLATION DETAILS OR THRU -� <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL J <br />SCALE: N.T.S. SS <br />BLOCK HEADER <br />1 X 4 FURRING <br />8d NAILS @ 8" O.C. AT BUCK <br />PROVIDE 2 x 8 DIAG. BRACE BT <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />2 x 8 VERT. BRACE(S) <br />BUILT UP PLWD. BUCK - <br />SCRIBE (NOTCH) BACKSIDE <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />INSTALL WDW, SCREW---' <br />ANCHOR INTO ARCH BLKG. <br />PER INSTALLATION DETAILS <br />114" MAX <br />IT <br />SOLID BLKG. AT TOP BTWN. <br />ARCH BLKG. & BUCK <br />2'-0" <br />2 x 8 BUCK - CONNECT TO BLOCK <br />— WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />/4" MAX EMBEDMENT INTO K.) <br />Z-0" <br />SOLID BLKG. AT TOP BTWN. ARCH <br />BLKG. & BUCK <br />191 <br />2 x 8 VERT. W/ (2)1 Od <br />NAILS AT EA. END ----- __� <br />LEAVE A CUT OUT IN O.S.B. ON T <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />7/16" OSB ARCH PANEL <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL <br />THRU OSB INTO 2 x 8 <br />B_B ARCH DETAIL rK <br />SCALE: N.T.S. SS <br />.- SECTION <br />A -A <br />8" <br />1/4" x 31 /4" TAPCONS <br />-LEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />-2 x 8 45 DIAAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3)1 Od NAILS <br />- AT EA. END <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAD. <br />SECTION <br />B-B <br />81' <br />EQUAL <br />PROVIDE 2x <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK - (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />PROPER INSTALLATION MAX. 8" <br />FILL SOLID <br />BOTH CELLS <br />#5 REBr <br />(TYP,) <br />STD. 90' <br />HOOK <br />±5n <br />NOTCH WEB AT <br />FIRST 2 COURSI <br />UPLIFT CAPACITY = 805 # FOR 1 STRAP <br />=1610 # FOR 2 STRAPS <br />1 PLY PRE-ENGINEERED TRUSS <br />SIMPSON HM9KT w/ (4) 1/4"xl 1/2" SDS <br />SCREWS & (5) 1/4" x 2 1/4" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 w/ (16)16d <br />SINKERS AND (7) 1/4"x21/4" TITEN = 2150 #) <br />BOND BEAM OR CAST IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T,S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL <br />USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />12 <br />JACK TRUSS PROVIDED BY SEE <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />(5) 12d NAILS SIMPSON <br />2X6 TO 2X4 H2.5A w/ (10) <br />8d NAILS <br />NOTE: <br />SHED ROOF ENDS TO BE <br />GABLE ONLY, CORNERS <br />SHALL NOT BE FRAMED AS <br />HIP. <br />DESIGNED ONLY FOR THE <br />INSTALLATION OF SHINGLE <br />AND METAL ROOF FINISH <br />GLASS BLOCK INSTALLATION NOTES <br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />EXPANSION STRIP <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />20 ga. PANEL <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT, FOR SOLID GLASS <br />ANCHOR <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT, <br />1/4" EXPANSION BOLT (2 <br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />9 ga. PANEL PER ANCHOR) <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />REINFORCING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />(EVERY OTHER <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />COURSE) EXPANSION STRIP <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />SEALANT <br />PRESS PANEL REINFORCING INTO PLACE. N <br />- ;.;.``:=`�`::..:. 611 MIN. LAP SPLICE W! <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />.� <br />REINFORCING PANEL <br />SMOOTH. DO NO FURROW. <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING -DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH, <br />6" MIN. LAP <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />SPLICE <br />REMAIN FREE OF MORTAR. <br />NOTE: <br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SEALANT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />GLASS BLOCK DETAIL <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAYBE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />JACK TRUSS PROVIDED BY <br />TRUSS COMPANY OR 2X4 <br />#2 SYP @ 24" O.C. <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH —/ <br />IF TRUSSES USED) W/ (2) #6 X 4Y2' WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2)1/4" X 31/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY L <br />SCALE: 3/4" = V-0" Qs") <br />#5 CONT. TOP & MID <br />" <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />i <br />r. <br />i <br />L FILLED CELL PER <br />FOUNDATION PLAN <br />r <br />YP.) <br />THE <br />:S <br />BRG WALL TYPE T- <br />PER PLAN I <br />I <br />F CHANNEL, -4-,_ <br />UNACCEPTABLE INSTALLTION <br />DO NOT DO THIS <br />o� <br />e® <br />#5 REBAR (TYP,) .1® <br />e® <br />®1 <br />ee <br />1e <br />'.®D. 90° HOOK (TYP.) <br />e® <br />@ FIRST COURSE <br />eeo <br />e° <br />1e <br />1e <br />2"x BOT. PLATE W/ (2)1 Old @ 6" O.C. <br />3/4" PLYWOOD DECKING GLUED — <br />AND NAILED W/ 8d COMMON @ <br />6" O,C. EDGES AND 12" O.C. FIELD <br />/—ATTACHED WALL SHEATHING TO <br />2X BOTTOM PLATE W/ 8d @ 4" <br />O.C., 2 ROWS STAGGERED <br />r-2x BAND JOIST W/ FACE NAIL 1Od <br />@ TOP & BTTM CHORD, AND (8) <br />FACE NAILS 1 Od @ TRUSS VERT. <br />WEB <br />METAL SEAT PLATE <br />NOTE: <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />SIMPSON HGAM10KTA @ 12" O.C, <br />w/ (4)1/4x1 1/2" SDS SCREWS <br />INTO BAND JOIST & (4)1/4"x2 3/4" <br />TITEN INTO K.O. BLOCK <br />FILLED CELL INSTALLATION H RETROFIT FOR MISSING EMBEDDED STRAP <br />SCALE: N.T.S. <br />SS SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. <br />SEE ARCH PLAN AND <br />PRE-ENG TRUSS DESIGN <br />SEE NOTE 1 BELOW <br />FASTENED PER i <br />NOTE 2 BELOW—L-A--1- <br />CONT 2X4 NAILED TO <br />BLOCKING w/ 2-12d NAILS (**) <br />2x SUB FASCIA <br />ALUM DRIP EDGE <br />• ALUM FASCIA <br />1-3/4" TRIM PAINTED <br />SS NAIL w/ 5/16" HEAD <br />DIA. @ 24" O.C. <br />CONT VENTED OR SOLID SOFFIT <br />2x BLOCKING NAILED TO TOP <br />CHORD EVERY OTHER TRUSS <br />W/ 3-12d NAILS, TYP. (**) <br />1. G.C./ BUILDER TO VERIFY/PROVIDE SOFFIT MATERIAL SPAN CAPACITIES BASED <br />ON THE DESIGN PRESSURES SPECIFIED FOR COMPONENTS AND CLADDING <br />LISTED IN THE DESIGN CRITERIA ON SHEET SN. <br />2. FOR SOFFIT ATTACHMENT AT WALL (PER ALPHA ALUM, INC. FL# 16544 R5 FL <br />PRODUCT APPROVAL) F CHANNEL FASTENED TO: <br />CMU w/ T NAIL .097" DIA. @ 24" O.C. w/ 5/8" MIN. EMBEDMENT <br />- WOOD w/ (3) 16 GA. 3/4"x1/4" CROWN STAPLES @ 24" MAX. O.C. IN DIAMOND <br />PATTERN <br />- SUB FASCIA w/ 16 GA. 3/4"x1/4" CROWN STAPLE @ EACH GROOVE <br />STRUCTURAL SOFFIT <br />/ SF01 SCALE: 3/4" = V-0" (**) FOR ALUMINUM SOFFITS WITH SPANS <br />REV. 09.23.2021 > V-4", INSTALL MID SPAN BLOCKING PER <br />THE SOFFIT FL PA INSTALLATION CRITERIA <br />*REFER TO THE PRODUCT APPROVAL FOR INSTALLATION DETAILS.* <br />W.W.M. AT PERIMETER <br />WHERE THIS CONDITION <br />OCCURS <br />WITH MIN. 3 COVER 6-0" <br />p <br />p A — — <br />g • =1 I 11 f=1TI= �11_� <br />GRADE p <br />- a <br />Cl) P <br />z_ <br />CV 2 • C. <br />a' <br />p (2) #5 REBAR. (1-STORY) <br />16" MIN. (1-STORY) (3) #5 REBAR. (2-STORY) <br />20" MIN. (2-STORY) WITH MIN. 3" COVER EA. WAY <br />01 <br />SECTION AT DEEP MONO FOUNDATION <br />REV. 07.28.21 <br />SCALE: 3/4" = V-0" <br />+ + <br />+ + <br />+ + <br />+ + <br />+ <br />2X4 SYP <br />EACH TRUSS <br />CONNECTOR <br />SEE LINTEL—' I/ III <br />SCHED. <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />TRUSS AS SHOWN FOR O.H. UP TO Z-6" <br />* DOUBLE 2X4 SCAB FOR Z-6" TO 4'-0" O.H. <br />(2)10d NAILS @ 8" O.C. <br />TO TRUSS TOP CHORD <br />PLYWOOD SHEATHING <br />BLOCKING AS <br />+ REQUIRED TO <br />�\ + SUPPORT SOFFIT <br />/ CENTER SOFFIT <br />PRECAST LINTEL <br />SEE ELEVATION <br />FOR OVER HANG <br />(MAX. 41.011) <br />SECTION @ ROOF EXTENSION M <br />SCALE: 3/4" = V-0" SS <br />SIMPSON HTT4 W/ (18)10d x 1 <br />1/2" NAILS TO STUDS & (1) - <br />5/8u DIA. ALL THREAD ROD <br />EPDXIED w/ SIMPSON "SET" <br />EPDXY MIN. 6" EMBEDMENT 8 <br />3" MIN. EDGE DISTANCE <br />RETROFIT FOR MIS <br />MSTAM STRAP <br />SCALE: 3, - 1 <br />a <br />z <br />O <br />U) <br />U_ <br />O <br />LU <br />U_ <br />U <br />FILL 1st 4 COURSES <br />SOLID W/GROUT <br />a <br />d <br />d <br />a <br />FOR OVERHANGS BETWEEN OVER 1 112" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. d ' d"'' %• <br />OVERHAN �5. <br />d' <br />d. <br />RETROFIT WALL OVERHANG DETAIL (NTS <br />FOR OVERHANGS BETWEEN 3/4" TO 1 112" <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D. <br />11-011 51-0" <br />.A ... I Y <br />A p .. #5 BAR011 <br />>� <br />D. 1-01, ° ° CENTERED W/ <br />9 H IN TOP o <br />.11r : KNOCKOUT / �t <br />° CHAIR BLOCK <br />MONO FOOTING <br />SIZE AND REINF. PER PLAN <br />AND SECTION DETAILS <br />e <br />CLEAN FILL .> A • °. <br />DIRT z <br />°• ° STANDARD c� <br />e ° N <br />#5 BAR IN 90HOOK <br />FILLED CELL, , <br />STEMWALL FOOTING SIZE AND <br />MONO TO STEMWALL FOOTING REINF. PERLAN AND STEMWALL <br />SECTION DETAILS <br />SCALE: 3/4" = V-0" <br />OTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJEC' <br />ONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />EPDXY CAP TO PREVENT LEAKAGE <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2") <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />FILL CELL FULL HEIGHT W/ <br />NON SHRINK GROUT. <br />#5x6' EMBEDDED INTO <br />EXISTING FOOTING <br />DRILL 3/4"x5" MIN. HOLE <br />SET BAR IN EPDXY <br />4" SAW CUT <br />EXISTING FOOTING A SECTION <br />j SCALE: N.T.S. <br />RETROFIT FILLED CELL DETAIL <br />SCALE: N.T.S. <br />C-9 <br />0 <br />twill <br />Cl) <br />W` <br />;Y <br />R L3 N <br />�ti a <br />rn'cc CP <br />� d <br />d <br />o <br />= <br />a <br />0 <br />AA <br />r ill• aSir�A <br />� <br />� <br />N0 ti <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />H <br />W or E <br />U W ( N <br />5 u7 ? N <br />W 0- - <br />NoLL <br />N <br />Q C J LL W <br />M Li. <br />z c a <br />Z � �o � <br />i, �=9z O <br />-rn m <br />Lu <br />Z N z° ¢ J <br />uW <br />us <br />n <br />Z N OU 0 <br />W El El <br />o g <br />z00 <br />z o <br />Q <br />J <br />N <br />c� L <br />c� LU <br />Q F <br />g <br />g <br />O LULn <br />wa <br />1— — EE <br />MINW J <br />I <br />S L `! <br />c <br />Q N 0 <br />o <br />c <br />C" M <br />M <br />�w <br />z <br />U <br />Z <br />Z <br />g <br />IJL <br />zo <br />�� <br />>N <br /><o <br />Cl. <br />E U <br />�® <br />oU <br />O <br />L <br /><� <br />a C, <br />o <br />Q <br />wz <br />rr � <br />C <br />¢ o <br />ZZz <br />p Y <br />ma <br />�. <br />z <br />^ <br />U <br />w <br />Z <br />¢ <br />J <br /><' <br />W <br />2. <br />fn <br />a8 <br />H W <br />z Z <br />g o <br />o< <br />-z <br />WQ <br />3 <br />U <br />r <br />'0 <br />C <br />5 <br />a <br />> L() <br />Q <br />m <br />L <br />� <br />co � <br />T— <br />Q <br />r <br />T— <br />0 <br />m <br />�. <br />LO <br />4_j <br />M04 <br />N <br />N <br />LO <br />ai <br />N <br />m i6 <br />o <br />z <br />z <br />E �• <br />i6 <br />r cc <br />d <br />U J -00 <br />JOB <br />NO : 22-06455 <br />SCALE : AS NOTED <br />SHEET NO. <br />SS <br />