Laserfiche WebLink
2x BLOCKING <br />J <br />TYP. <br />U.NO. <br />00 <br />J <br />LL <br />�J <br />@ 24" O.C. <br />MIN. (2) <br />STRAPS <br />2x BLOCKING <br />/--,JATYP.@ <br />LOW ROOF <br />vn <br />(� C7 <br />CJ2G I — CJ2G <br />2 I I <br />D2 CJ4G I I C7 <br />_ 2A1 <br />—T—r - — — <br />II T <br />I I CJi <br />II <br />— <br />II <br />II <br />II <br />I I <br />I I <br />T1 — <br />P <br />FL2 _ <br />R <br />A II FL9 IcL <br />2) <br />i C-0j <br />A TYP. @ <br />S3)STORY <br />SINGLE <br />^ \TYP. <br />^f U.N.O. <br />TYP. @ <br />CORNERS <br />D2 <br />J <br />V <br />TYP. <br />U.NO. <br />(2) <br />A <br />S5 <br />SIM. @ <br />CONNECTIONS <br />ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />RSH CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT <_ 25 ft <br />✓IND SPEED (ULTIMATE) 140.0 MPH <br />AND SPEED (ALLOWABLE) 108.4 MPH <br />XPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) <br />WIND AREA {+) VALUE DENOTES PRESSURE HIP ROOF >20 TO 45 DEG. <br />(SQ FEET) (-) VALUE DENOTES SUCTION [4:12]-[12:12] <br />a=oft <br />AREA ROOF 1 2e 2n 2r 3 3e 3, <br />HIP 1 -35.94 1 -49.57 -49.57-49.57/�� <br />10 _ <br />GABLE 1 -38.22 1 -38.22 -60.99 -60.99 1 -60.99 <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): r <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD r <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: (D (D <br />SHINGLE: Y16" EXP. 1 CY16) or IV32" EXP. 1 (3y6) <br />TILE: 1%2' EXP. 1 03,6) r <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 %" x 0.113") NAILS �i 3r 3r r� <br />w <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1V32', SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 RSRS-03 10d (2Y2" x 0.131 ") NAILS OR ASTM F1667 RSRS-04 (3" x .120") NAILS a=oft <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER GABLE ROOF > 20 TO 45 DEG. <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING [4:12]-[12:12] <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />2x STUDS @ 16" O.C. <br />w/ SIMPSON SP1 w/ (10) 10d <br />NAILS AT BASE & SIMPSON <br />SP2 w/ (12) 10d NAILS AT TOP <br />2x BLOCKING BETWEEN STUDS <br />TO TRUSS W/ (2) 12d TOENAILS <br />EACH END ( BETWEEN TRUSSES <br />(2) 12d NAILS TO EACH VERTICAL <br />LOW ROOF/WALL STUD) <br />SHEATHING ATTACHED <br />PER NAILING SCHEDULE 2x BASE PLATE W/ (2) 12d <br />NAILS @ 16" O.C. ALONG W/ <br />SIMPSON MTS12 W/ (14) 10d x <br />1 112" NAILS TO BLOCKING <br />BELOW @ 16" O.C. <br />LOW ROOF TRUSS W/— <br />RAISED BOTTOM CHORD <br />EXTENSION SEE TRUSS <br />MANUF. SPEC'S FOR <br />CONNECTIONS TO G.T. <br />SECTION <br />SCALE: 3/4"=1'-0" <br />PLYWOOD <br />FLOORING <br />L (2) 2x6 BLOCKING UNDER- FLOOR G.T <br />2nd FLOOR WALL w/ SEE PLAN <br />SIMPSON LUS24-2 w/ (16) <br />16d NAILS AT EACH END <br />BUMP OUT 39 <br />UPLIFT CONNECTION CROSS-REFERENCE <br />LARK <br />SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />O <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 - 10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />k (2) <br />(2)META12 <br />1875 (1)PLY <br />1795(2)PLY <br />9 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 -10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 -10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 10d x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 - 10d x 1 1/2"& 8-10d <br />H <br />FGTR <br />4725 <br />3400 <br />w/ (18) 1/4" x 3" SDS <br />WOOD SCREWS AND (2) <br />1/2" x 5" TITEN HD ACHOR <br />BOLTS <br />RFUS <br />7100 <br />--- <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH.1(26) 10dxl-1/2" <br />HTT5 <br />5795 <br />5/8" ANCH. /(26) 10d x1-1/2 <br />K <br />HD3B * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />--- <br />2 - 5/8" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />X 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 ** <br />1005/915 ** <br />8 - 10d x 3" <br />JUS26 <br />1000/1080** <br />--- <br />8-10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 - 16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />--- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />172013125 ** <br />30 - 16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />--- <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 - 10d x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-10d x 1-1/2" <br />S <br />VGT - M <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND (1) <br />5/8" ATR EPDXIED w/ <br />SIMPSON SET w/ 12" MIN. <br />EMBEDMENT. <br />T <br />(2) LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />w/ (24) 1/4" x 3" SDS <br />SCREWS & (8) 3/8" x 5" <br />TITEN HD (2 PLY) OR (52) <br />16D SINKERS FOR FRAME <br />U <br />MGT <br />3965 <br />3330 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET' <br />EPDXY <br />MUGT15 <br />4175 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ USP CIA-7000C <br />EPDXY <br />V <br />(2) LGT2 <br />4060-M 3770-F <br />3500-M 3240-F <br />`N/ (32) 16D SINKERS & <br />(14) 1/4" x 2 1/4" TITENS <br />(2 PLY) OR (28) 16D <br />SINKERS FOR FRAME <br />LUGT2 <br />3100-M 4520-F <br />3100-M 3800-F <br />w/ (32) 16D SINKERS & <br />(10) 1/4" x 3" WEDGE- <br />BOLTS (2-PLY) OR (32) 16 <br />SINKERS FOR FRAME <br />u <br />"X" <br />HTS 20 <br />1310 <br />1245 <br />24-10d x 1 1/2" <br />HTW20 <br />1530 <br />1285 <br />24-10d x 1 112" <br />SP1 <br />555 <br />535 <br />10-10d <br />SPT22 <br />735 <br />8-10d <br />SP2 <br />1010 <br />605 <br />12-10d <br />SPT24 <br />logo <br />12-10d <br />HCP2 <br />590 <br />555 <br />12-10d x 1 1/2" <br />HHCP2 <br />680 <br />570 <br />(20)10d x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />*** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12-02-20 <br />LOADS -- ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />*FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (6) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ("). <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE T-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />1 (2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />(A) <br />OR 2 PLY <br />;ARRIER <br />0 <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />SEP 0 8 2022 <br />VIRTUAL Rt'= ' S`'rT <br />Virtual 11G. <br />-o ed <br />Plans F'evr.y 4 GG'iT ;_ <br />for conlPiiance voth (ire 2-IJ�= :' tb <br />Edition by Debra Klahr P/:2300 <br />FLOOR FRAMING PLAN - ELEV - B <br />SCALE: Y4'=1'-0" <br />-6 <br />�N <br />a° Ca <br />L 0 ,,vvim� <br />q a°°°•. p' <br />�6 �16t <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />cD <br />W <br />Q <br />v E 1 <br />O M U (co, r, <br />O N # J <br />04 <br />� J <br />0 <br />.a) <br />5 t; o? � ik �; W <br />H <br />Q <br />Cl) r- t` w LL a- <br />�m0v Ui ai <br />J LL LL a LU <br />o <br />Z <br />_ <br />r6�vo <br />O: <br />� °c, O~w <br />13 N co O <br />WU) <br />1� O' <br />Z <br />IL <br />IL <br />a <br />N M Z LO 0 <br />= <br />U O U _j Cn <br />W <br />��❑ <br />O O <br />z <br />Z o <br />J <br />a � <br />N <br />r I <br />ch <br />W <br />o <br />u- <br />4-J <br />v, <br />G' <br />U <br />0 <br />Lu o <br />(/'1 <br />c <br />/N'� <br />w <br />(j) <br />w �E <br />{m <br />= w � <br />0 as <br />C cs <br />�® <br />Qco N <br />�� <br />o <br />w <br />M <br />0 <br />z <br />a <br />LL_z <br />O <br />o <br />o� <br />? <br />g <br />o a <br />o <br />_�� <br />I <br />CL <br />oa <br />Z <br />O E <br />N <br />az <br />a o <br />aZ <br />wz <br />� � <br />__ C <br />az <br />Y <br />U <br />. 9 <br />mo <br />O ¢ <br />Z <br />z <br />J <br />a tl <br />Q W <br />z <br />to <br />� <br />o¢ <br />z <br />ao <br />W <br />U <br />�o <br />�w <br />�o <br />o <br />V <br />w <br />w <br />z¢ <br />r= <br />a <br />o <br />O <br />C O <br />E01 <br />N <br />> <br />f0 <br />V <br />c� <br />i� <br />O <br />Q <br />LJ.. <br />U) <br />�p <br />~ <br />+, <br />� <br />O <br />o <br />L0 <br />T.. <br />Q <br />N <br />T <br />ui <br />m <br />w <br />N <br />y CN <br />o <br />Z <br />Z <br />E CV <br />a) <br />cc <br />d <br />E <br />U j <br />Q p <br />CD <br />JOB <br />NO: <br />22-02366 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />6.1 <br />