My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6357 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6357 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 2:40:06 PM
Creation date
2/19/2025 11:39:19 AM
Metadata
Fields
Template:
Building Plans
Street #
6357
Location
Beverly Hills Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
4580
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />WALL SHEATHING <br />16GA0412" LONG (3/4"-1" CROWNi 1 n' I, r <br />STAPLES @ 6" O.C. VERT BETWEEN I MAX I ! I i I 16GAxl-1;"2" LONG (3!4'-1" <br />STUDS (NOTED THUS:.—) - OFFSET I I I I I CROWN) STAPLES jai 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />INOTED THUS:—) <br />M ETAL LAT H ATTAC H M E NT DETAIL <br />REV. 09.24.21 SCALE: 34" = T-0" <br />'DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH' <br />*`ONLY APPLIES TO LENNAR TPA/JAX`* <br />LATHING ACCESSORIES: <br />ATTACHMENTS SHALL BE OF CORROSION -RESISTANT MATERIALS. <br />WOOD APPLICATION: 16 GA. x 1-1/2" LONG (3/4"-1" CROWN) STAPLES @ 6" O.C. <br />VERTICALLY/HORIZONTALLY INTO FRAMING MEMBERS. <br />MASONRY APPLICATION: CONCRETE STUB NAIL, 3/8" (10 MM) HEAD DIA. MIN. @ <br />6" O.C. VERTICALLY/HORIZONTALLY OR COMPATIBLE ADHESIVES, EXTERIOR <br />GUN -GRADE, CONSTRUCTION ADHESIVE WITH 1" DABS @ 6" O.C. OR IN A <br />SEMI -CONTINUOUS BEAD BETWEEN THE SOLID PLASTER BASE AND THE SOLID <br />PORTION OF THE KEY ATTACHMENT FLANGE. <br />CONTROL JOINTS: INSTALL CONTROL JOINT LATHING ACCESSORIES IN <br />CONFORMANCE WITH C1063. LATH SHALL NOT BE CONTINUOUS THROUGH <br />CONTROL JOINTS, BUT SHALL BE STOPPED AND TIED AT EACH SIDE. <br />ALL ACCESSORIES SHALL BE IN ACCORDANCE WITH THE LATEST ASTM C1063 & <br />ASTM C1861. <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />5'-011 <br />STUB -OUT FOR <br />GAS METER O <br />0 <br />1 <br />N <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS" <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2) 16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13-9" <br />(3) 16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HIS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2) 16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2) 16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2) 16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'4" <br />(3) 16d 'i OENAILS <br />2" X 12" @ 24" O.C. <br />15'4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />=TOEUNA CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />RN YELLOW PINE, 55 PSF LOADING <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />0_1 <br />-O"(Typ) <br />+ <br />+ <br />15/32" CDX <br />ma <br />PLYWOOD OR <br />7/16" OSB <br />RIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE <br />140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS <br />8d RING SHANK NAILS @ 6" O.C. EDGES & <br />8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER <br />0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH <br />16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />2-3/8 INCH NAIL LENGTH <br />2-3/8 INCH NAIL LENGTH <br />NOTE: * FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + + <br />+ <br />+ + <br />+ + <br />+ + + + + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />t t <br />+ <br />+ t <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ + + + <br />+ <br />+ <br />+ <br />+ <br />/++ <br />+ <br />+ + <br />+ + <br />+ + + + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" <br />5000s 1.8/1.7 <br />p nel <br />wood panels <br />Two 3/4" wood panels or 2 x <br />P — <br />1-1 /8" or two 1 /2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1 /2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x —+ 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />902.0 <br />2 x — lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONS <br />(Not required if both loa <br />Filler <br />1/8" gap <br />FILL CELL- STD. 900 HOOK r- BOND BEAM <br />Cn <br />w <br />............1............ ...... <br />STD.90° <br />CONT. #5 <br />CONT. #5 HOOK <br />BAR <br />BAR <br />OOC <br />#5 CONT. <br />I <br />......;. <br />:......... <br />FROM <br />FO <br />TOUNDATION HIGHESST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from <br /># OF 2nd FLOOR <br />above to bearing below. <br />STUDS <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8" min. Small 2" min. <br />2" max } <br />gap <br />• � 4 max. <br />Clinch nails <br />when <br />possible 1 <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />2x4/Plywood/OSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. <br />2x : CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Ye" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />t. <br />DOUBLE JOIST CONNECTION top irdsmouth cuts. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor coh,mn w/ Inaric <br />N.T.S, <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />`Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />consideration. Check <br />wall or beam below.` <br />local building <br />code for appropriate <br />1/16" <br />details inIL--or--20 <br />One 10d box <br />areas=20 of high <br />sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block / <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam e <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —� <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />l Ica 3" 11 Aril nails nt R" n r <br />Q'/ Provide adequate bearing <br />for each lapped joist. <br />Od nails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below &13/4" <br />d bearing wall must stack over <br />king and wall or beam below.` <br />Joist <br />n joists meet over wall, provide <br />minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. <br />F_•� <br />IM <br />�! <br />6" 2 6" 6" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2" <br />Round Hole Diameter (in) <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />8.875 <br />10 <br />11 <br />12 <br />13 <br />Rectangular Hole Side (in) <br />2 <br />3 <br />5 <br />6 <br />8 <br />9 <br />10 <br />Any 16" joist <br />Span (ft) <br />8 <br />V-0" <br />V-1" <br />V-2" <br />1'-2" <br />V-3" <br />V-3" <br />V-7" <br />V-11" <br />2*4" <br />2'-9" <br />3'-2" <br />3'-7- <br />12 <br />V-0" <br />V-1"' <br />1'-2" <br />1'-2" <br />T-3" <br />1'_9" <br />2'-4" <br />2'-11" <br />3'-7" <br />4'-2" <br />4'-9" <br />5'-4" <br />16 <br />V-0"" <br />V-1" <br />1'-2" <br />V-2" <br />T-7" <br />2'-5"' <br />3'-2'" <br />3'-10"' <br />4' 9" <br />5'-7" <br />6'-4" <br />7'-2" <br />20 <br />1'-0" <br />1'-1" <br />1'-2" <br />V-2" <br />2'-0"' <br />S-0"' <br />4'-0" <br />4'-10" <br />5'-11"' <br />6'-11" <br />7'-11" <br />8'-11" <br />24 <br />1'-0" <br />1'-1'" <br />1'-2" <br />V-3" <br />2'-5"' <br />3'-7" <br />4'-9" <br />5'-10" <br />7'_2" <br />8' 4" <br />9'-6" <br />10' -9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT, DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN, <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />A <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />® <br />BCI5000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />- <br />BCI6000s® <br />BCI6500se <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/ (22) <br />NAILS 7 <br />5/8" 0 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS 7 <br />R TRUSS <br />'OP PLATE <br />l.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) :III —I I 1=J I _11T7�;F# <br />Nail with 10-10d nails. -111=111—III- <br />Install tight to top flange. SLEEVE THRU STEM <br />SEE PLAN FOR °• a . • • a <br />FOUNDATION INFO ° d <br />STEM FOUNDATION <br />�✓ \ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Blockl____�l <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />0 requirements <br />0.6 X Joist <br />p depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />° <br />r- REIN F. SEE PLAN <br />LA/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />�® <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A <br />(WHEN <br />w/ (18) 10d x 1 1/2" <br />° <br />REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />1 ° ' <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />d I° a <br />\FTT <br />I •' _ <br />=1 - I A. a:° <br />d i —Illr <br />1 I <br />F_ I <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4' 0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />d <br />� Y <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />• ° d <br />------4 d --.— — da. d/ <br />I I I ,4 1=1 <br />a A __ I— <br />i —I I I - <br />;IIIII�—III ; I'' <br />A. <br />I~ <br />SEE FND. PLN. <br />SIZE & REINF. <br />M �, V / <br />VR//\ <br />VIRTUAL REVIEW ASSIST <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th <br />Edition by Debra Anne Klahr PX2300 <br />N <br />N <br />0 <br />N <br />® <br />�c <br />(N <br />J <br />♦ W DC)"y00 <br />F <br />Ln <br />In <br />2 , <br />�t <br />, <br />Q <br />s AR 5805 ♦ A. <br />sev . <br />Z <br />W <br />A <br />o <br />LLI <br />0 <br />z <br />a <br />^` <br />W <br />11,0- E <br />>` � 11 o <br />MN S <br />N <br />V -0 -0- « ') <br />(D = L Cl) <br />�O u <br />T� <br />v_/ <br />O � g Q <br />m <br />t U <br />.N <br />p� 2 <br />U w Q� N <br />V <br />V 0 �a 'oo <br />W W <br />W <br />w <br />wWQ �2� WM��zOf z <br />of <br />02 <LL ����UDO <br />Q C) <br />Q f- F- <br />QZ)—_J <br />=(f <br />OCOW110 <br />JO <br />X Z W OZ2011F—Q~ <br />ORDOmZZ v <br />Lu <br />L'J 0 0 <br />J <br />_30a>zY0 ZLLpWo a. <br />Q�W°��In i1Wo��Q <br />U_Z <br />OOQ o M oY<z <br />¢� a <br />O <br />O <br />N <br />OW <br />V) � N <br />i>-i t) C:) O <br />O <br />Q (! L^ <br />(L L <br />W Q <br />00 Z I— <br />Z <br />LU <br />W <br />JO <br />N <br />N <br />O <br />N <br />O <br />1 <br />N <br />0 <br />0 <br />00 <br />O <br />� <br />O <br />r <br />O <br />� <br />O <br />N <br />O <br />N <br />O <br />N <br />04 <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />N <br />o- <br />O <br />O <br />- <br />CO <br />0 <br />CV <br />T-- <br />A <br />0 <br />M <br />4 <br />0 <br />1& <br />0 <br />0 <br />C) <br />0 <br />O <br />O <br />A <br />0 <br />.0 <br />Lo'_. <br />O <br />N <br />O <br />M <br />o <br />0 <br />VO <br />0 <br />CC <br />0 <br />t�_ <br />0_ <br />M <br />(� <br />Z Z <br />o <br />rV <br />owv� <br />UJ <br />C <br />Uo20 <br />~o <br />I— <br />(LW� <br />LO <br />-0 <br />Z <br />ZW~Q <br />Of ~ <br />= <br />m z <br />= <br />Z 3 W <br />}ZIt <br />TI <br />Z Z <br />M <br />� tM� <br />O_J2W <br />w <br />z <br />Cn Z z <br />r� <br />Z <br />�QG <br />U <br />CU <br />J <br />a <br />00 <br />m <br />� <br />Z <br />a <br />Z <br />z <br />J <br />UJ�N <br />o <br />r <br />LAST PLOT DATE <br />Feb. 21, 22 <br />z-`—+ <br />Q <br />STRUCTURAL <br />J <br />DETAILS <br />