Laserfiche WebLink
A/C <br />DISCONNECT <br />WP <br />GFI <br />ELEC <br />METER <br />FIRST FLOOR ELECTRICAL PLAN A <br />1 /4" = 1'-0„ <br />SECOND FLOOR ELECTRICAL PLAN A <br />1 /4„ = 1'-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE, <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED !N NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />1 <br />00 AMP <br />200 <br />0. #12 copper to 20 amp ckts <br />#10-2 copper to WH <br />00 #10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 <br />& 250.52 NEC <br />"_"TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />L"Au <br />VIRTUAL REVIEW ASSIST <br />Virtual Review Assist, Inc. <br />Plans Review completed and roved <br />for compliance with the 2020 FBC 7th <br />Edition by Debra An-- !,,,Iahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />`4 <br />SWITCH--° <br />4 1 /2" <br />DOOR JAMB DUPLEX <br />OUTLET ih <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o2� <br />'2C—SMOKE <br />DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />11 OV DUPLEX OUTLET AT 12" <br />11 OV DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />11 OV DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />11 OV DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 11 OV DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />11 OV QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />11 OV DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />�- SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-o PUSH BUTTON FOR GARAGE DOOR OPENER <br />fl DIMMER SWITCH AT 36" <br />-f] PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />}B CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />> WALL MNT FIXTURE <br />NOTE: <br />C TUB/SHOWERND OPALEX - ALTERNATE <br />CANS MAY BE <br />0- 5OW PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE OWNER <br />C 50W PAR20 NFL 4" MINI ROUND RECESS <br />@?Z 5OW PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0- CLG FAN PREVVIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />Cos SMOKE DETECTOR <br />O SMOKE DETECTOR <br />-U-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24- UNDER CABINET 24" <br />-S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />F,- 24 :�a 24" VANITY LIGHTING <br />36 � 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />EXHAUST FAN <br />p�p DOUBLE FLOOD LIGHT W/ COVERS AND <br />L% 15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />)� MASTER STATION <br />ELEC PANEL <br />® VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />® A/C REGISTER <br />C THERMOSTAT <br />TR SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />` <br />RO I 0 ,A, <br />e fin, .PCs <br />4��. <br />A <br />n` <br />W <br />n' N E <br />L ` � �^� O <br />Q M N ti <br />N � <br />cn <br />U �C <br />C ` t gM <br />O <br />O <br />m <br />�U1 <br />ci <br />w Q� <br />� N C <br />00 E <br />7W <br />L 5 <br />w W <br />W <br />W� W (6WW�O <br />Q Q I(.)DOD <br />�O��O���Cn u U000 <br />z30z20 QVQ <br />I.- <br />OrnOZOWOOmo0 <br />LU L5 wWv5�Z� <br />~¢OZW aOLuWwci �Q <br />ow z <br />oo Es <br />u- a O F u- <br />N <br />O <br />O <br />N <br />OW <br />= O <br />0 <br />`M O <br />Ln <br />din J <br />(L LL N <br />W Ln <br />Z <br />Z <br />W <br />Jo <br />to <br />N <br />O <br />N <br />i <br />O <br />N <br />O <br />O <br />06 <br />cfl <br />ao <br />0 <br />0 <br />0 <br />0 <br />O <br />o <br />N <br />o <br />N <br />O <br />N <br />o <br />N <br />O <br />N <br />O <br />N <br />N <br />M <br />O <br />N <br />6 <br />O <br />4 <br />O <br />— <br />O <br />— <br />00 <br />o <br />O <br />N <br />T- <br />O <br />M <br />o <br />N <br />4 <br />0 <br />00 <br />6 <br />O <br />0 <br />.- <br />o <br />O <br />1 <br />.L <br />Lo�' <br />V , <br />.- <br />O <br />N <br />O <br />M <br />O <br />d' <br />O <br />Ln <br />O <br />CO <br />O <br />f,- <br />1 <br />Cr <br />M <br />w <br />Z Z <br />-Zo <br />vV <br />+� <br />W0�> <br />W w v_ <br />0 <br />0 <br />Q <br />voo <br />Q <br />C <br />~ <br />Oa=Q <br />z <br />ZW�I- <br />=MOZ <br />I— <br />Z W <br />Q <br />�nzW <br />T1 <br />Z Z <br />M <br />� � <br />Ogg <br />r <br />Z <br />Z T <br />Z <br />�Q0 <br />Z <br />U <br />c� <br />g <br />00 <br />m <br />� <br />z <br />A6Z <br />Q <br />J <br />W <br />N <br />LAST PLOT DATE <br />> <br />Feb. 21, 22 <br />z <br />0 <br />1 ST & 2ND FLOOR <br />J <br />ELECTRICAL PLAN A <br />