Laserfiche WebLink
rW►u.wyr►I!! �..�► .ul, ., :. L_. L - A-l 1L_ 1 , - -- l .L . _�1 1 -..1 <br />Lrrf <br />3 <br />3 <br />co <br />20 <br />C9 <br />S <br />Q <br />0 <br />J <br />t2 <br />0 <br />a <br />cc <br />ro <br />Ln <br />rn <br />S <br />9 <br />t2 <br />0 <br />Lo <br />S. <br />v <br />B <br />O <br />3 <br />H <br />Q <br />O <br />i <br />E <br />F� <br />E <br />0 <br />`v <br />J <br />8 <br />4 <br />e <br />i <br />a <br />o <br />81 <br />J <br />t� <br />0 <br />S <br />0 <br />a <br />0 <br />s <br />a <br />CROSS BRACING DETAIL (TYP.)r1 <br />SCALE:NTS <br />TRUSS NOTES: <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 CONV. FRAMED RIDGEMAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. Cg <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. Dg <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 10d x <br />1 1/2" NAILS EACH <br />TB <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP — <br />MAX & EACH END ALTERNATE CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. —� <br />----L WOOD TRUSS J <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: NTS <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL <br />SCALE: NTS <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />TRUSS <br />SEE ROOF <br />PLAN SHEATHING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />➢A TRUSS <br />HIP <br />G.T <br />(2) 12D NAILS <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />SCALE: NTS <br />(2) 2x8 #2 SYP wi <br />O.S.B. FLITCH PI <br />TOP @ TRUSS B <br />U.N.O. ON ROOF <br />PLAN <br />TYPIC <br />WALL <br />NOT,kj BENDING BEAM <br />BEA NG LOCATION, THE <br />BEAM CAN SIT ON TOP OF <br />COLLWN w/ (2) SIMPSON li <br />HTS2b it/ (24) 10d x 1 1/2" <br />NAILS EACH <br />SIM N HU46/HUC46 w/ (8) <br />16d L5 TO POST & (4) 10d <br />NAIL L0 BEAM <br />SUPP Wr COLUMN BUILT-UP <br />(2) 2X� OR 4x4 w/ (2) 10d <br />NAILS; 8" O.C. EACH PLY <br />(SHO N AS 4 x 4) <br />(2) S14SON HETA20 w/ (8) 10d <br />x 1 V24'NAILS EACH - OR (2) <br />SIMPS. N MSTAM36 w/ (7) 10d <br />& (4) 1f 'x2 1/4" TITENS EACH <br />TIE BEAM <br />BEAM @ RAISED ENTRY <br />MASONRY WALL 4 <br />SCALE: NTS <br />SIMPSON LSTA18 <br />VERTICAL SCAB 2 x 6 w/ (12) 10d NAILS SIMPSON HUC410 w/ (14) L.SEE PLANL. <br />#2 SPF 48" O.C. W/ (4) CENTERED AT 16d INTO HEADER & (6) FOR CANT. <br />10d TOP & BOTTOM SPLIT TO TIE 10d INTO BEAM -SEE <br />OR SIMPSON H2.5A w/ BEAMS TOGETHER ROOF PLAN FOR MORE <br />(10) 8d NAILS INFO <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2x4 SPF 2 (2) #7 x 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO TIE BEAM <br />2X4 CONT. AT- / CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL @ INTERIOR BEARING <br />SCALE: NTS <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />OIL VARIES - <br />2x4 #2 SPF BRACING @ <br />16" O.C. W/ (4) 12d <br />TOENAILS TO TOP <br />PLATE & (2) 12d END <br />NAILS TO TRUSS <br />BOTTOM CHORD <br />ROOF SHEATHING <br />ATTACHED PER <br />NAILING SCHEDULE <br />COMMON TRUSSES. <br />— SEE TRUSS PLAN <br />MIN. (2) 2x4 FOR CONNECTION <br />SPF TOP INFORMATION. <br />PLATE <br />VARIES SEE PLAN <br />FOR WALL LOCATION <br />�- MIN. 2X4 #2 SPF STUDS @ <br />16" O.C. W/ EXTERIOR <br />SHEATHING ATTACHED <br />PER NAILING SCHEDULE & <br />(3) 12d TOENAILS TO <br />OIL SEE PLAN FOR <br />PLATE BELOW <br />TOP OF WALL <br />MIN. 2X4 #2 SYP P.T. PLATE <br />4 <br />W/ 1/2"X8" EPDXY ANCHOR <br />MASONRY WALL SEE <br />@ 3" FROM EACH END & <br />PLAN FOR MORE <br />16" O.C. MAX. <br />INFO. <br />° <br />SECTION_@ <br />ENTRY <br />s <br />SCALE: NTS <br />SEE FLOOR PLAN <br />FOR COLUMN SIZE <br />& ADDITIONAL INF1 <br />SEE FLOOR PLAN FOR <br />COLUMN SIZE & BASE--7/16" OSB FLITCH PLATE <br />CONNECTION INFO REQ'D ONLY WHEN <br />INDICATED ON BM. <br />7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR SCHEDULE/PLAN <br />REQ'D ONLY WHEN COLUMN SIZE & BASE <br />OPTION A INDICATED ON <br />SC EDU E/PLANM OPTION B CONNECTION INFO OPTION C <br />COMMON BM. TO POST ATTACHMENT rA� <br />SEE ROOF PLAN <br />FOR BEAM SIZE & <br />CONNECTION INFO. <br />SIMPSON MTS18 w/ (14) <br />10d NAILS TYP. U.N.O. <br />SEE FLOOR PLAN FOR — <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />A A <br />SEE PLAN FOR <br />O <br />U <br />SEE PLAN FOR <br />CANTILEVER IF <br />INDICATED <br />CORNER SEE FOUNDATION <br />< [�— PLAN FOR MORE INFO <br />5" <br />COMMON BM. ATTACHMENT <br />SCALE: NTS <br />2X4 STUDS w/ SIMPSON <br />SP1 w/ (10) 10d NAILS <br />AT BASE SEE J/S6 FOR <br />MORE INFO. <br />EXTERIOR SHEATHING <br />ATTACHED PER <br />NAILING SCHEDULE <br />2X4 BASE PLATE W/ <br />SIMPSON LSTA30 w/ <br />(22) 10d NAILS OR <br />SIMPSON MTS12 w/ <br />(14) 10d x 1 1/2" NAILS <br />TO FLOOR GIRDER <br />BELOW @ 16" O.C. <br />16" FLOOR SYSTEM FLOOR GIRDER <br />SEE PLAN FOR SEE PLAN FOR <br />DIRECTION CONNECTION <br />SECTION @ FLOOR <br />CONNECTION r22� <br />SCALE: NTS <br />SCALE: 3/4"=1'-0" <br />SIMPSON <br />MTS18 w/ (14) <br />10d NAILS <br />TYP. U.N.O. <br />SEE 1/S5 FOR - <br />ADDITIONAL <br />OUTLOOKER <br />INFO, <br />GABL <br />1/2" PLYWOOD <br />(2) 16d NAILS TO <br />EACH COMMON <br />TRUSS/ FRAMING <br />TYP TOP & BOTTOM <br />MIDDLE <br />8d NAILS AT <br />4" O.C. <br />BM. SPLICE OVER <br />CENTER OF POST <br />SEE PLAN FOR <br />VALLEY TRUSS <br />INFO. <br />`—• MASONRY WALL BELOW: SIMPSON <br />a°. HETA16 w/ (9) 10d x 1 1/2" NAILS @ <br />MASONRY WALL 4'-0" O.C. TO GABLE TRUSS <br />OR BEAM • BEAM BELOW: SIMPSON HTS20 w/ <br />SEE TRUSS PLAN E (24) 10d x 1 1/2" NAILS @ 4'-0" O.C. <br />TO GABLE TRUSS <br />COMMON TRUSS <br />° SEE ROOF PLAN <br />FOR CONNECTION <br />SECTION AT HIP GABLE <br />SCALE: NTS <br />JACK TRUSS (AS SHOWN) <br />OR GABLE END SEE TRUSS <br />LAYOUT <br />CLIP EACH TRUSS <br />(SEE ROOF PLAN <br />FOR TYPE) <br />FRAME OUT TO <br />BLOCK EDGE <br />SEE PLAN <br />FOR BEAM SIZE <br />EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE 2x SPF #2 <br />AT 16" O.C. <br />BUILDER FRAME <br />RADIUS <br />AS REQUIRED <br />KNEEWALL aC� ENTRY FRONT WALL <br />2X4 #2 SYP NAILER. NAIL <br />TO STUDS w/ (3)16d AT <br />EACH STUD - TOENAIL <br />EACH TRUSS TO NAILER <br />W/ (3)10d <br />SCALE: NTS <br />ROOF AND EXTERIOR <br />SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />w/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY <br />W/ (3) ROWS OF 16d <br />NAILS AT 24" O.C. <br />• <br />SIMPSON LUS26 w/ (8)10d NAILS <br />OR IF 2 PLY TRUSS SIMPSON <br />LUS26-2 w/ (8) 16d NAILS TO <br />SEE FLOOR FRAMING PLAN <br />LEDGER <br />AND J/S6 FOR MORE INFO. <br />VERIFY WITH PLAN FOR <br />2X10 #2 SYP CONT. LEDGER w/ (3) <br />LOCATION AND DIRECTION <br />1/2" X 4 1/2" LAG SCREWS ATTACH <br />(IF PARALLEL SEE 2/D2 FOR <br />LAG SCREWS INTO END OF EACH <br />BLOCKING INFO) <br />FLOOR TRUSS, 24" O.C. MAX. (AT <br />EACH SIDE OF G.T. INSTALL (4) LAG <br />MASONRY WALL <br />SCREWS EACH SIDE) <br />(TYPICAL) <br />SECTION AT LOW ROOF rg <br />SCALE: NTS <br />LOW ROOF/WALL <br />SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />�-- 2x STUDS @ 16" O.C. <br />W/ SIMPSON SP1 w/ (10) 10d <br />NAILS AT BASE & SIMPSON <br />SP2 w/ (12) 10d NAILS AT TOP <br />2x BLOCKING BETWEEN STUDS <br />TO TRUSS W/ (2) 12d TOENAILS <br />EACH END ( BETWEEN TRUSSES <br />(2) 12d NAILS TO EACH VERTICAL <br />STUD) <br />2x BASE PLATE W/ (2) 12d <br />NAILS @ 16" O.C. ALONG W/ <br />SIMPSON MTS12 w/ (14) 10d x <br />1 1/2" NAILS TO BLOCKING <br />BELOW @ 16" O.C. <br />— PLYWOOD <br />FLOORING <br />LOW ROOF TRUSS W/—' <br />L (2) 2x6 BLOCKING UNDER FLOOR G.T. <br />RAISED BOTTOM CHORD <br />2nd FLOOR WALL w/ SEE PLAN <br />EXTENSION SEE TRUSS <br />SIMPSON LUS24-2 w/ (16) <br />MANUF. SPEC'S FOR <br />16d NAILS AT EACH END <br />CONNECTIONS TO G.T. <br />SECTION @ <br />BUMP OUT 39 <br />SCALE: NTS <br />DETAILS &SECTIONS <br />N <br />N <br />N <br />N <br />V <br />O dWj <br />7 W <br />i <br />= O <br />ag o G OC C-9 N <br />x <br />' a <br />N y C M <br />Q �N � <br />d <br />d <br />E" = <br />, <br />d C' d <br />ro d <br />O <br />Q) ro <br />N E <br />C <br />ro <br />o <br />ot1E4Ot l!tofkkvdr <br />gR r <br />— ;•\ 2 NN <br />Q J <br />C <br />U � r1 ,�� O `�• r� <br />Off' <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />O M <br />O N <br />p <br />N �[j <br />N 00 � N Ono <br />'C'-4P J <br />Q <br />J u- u- LL W <br />a <br />LU <br />0) a- <br />OC <br />5aN o0 <br />W °' m <br />6 <br />unzU Z< <br />ZN OU <br />W <br />c� <br />z <br />z <br />¢ $ <br />N <br />� z <br />� o <br />LL <br />mW <br />.V W <br />� 8 <br />Of <br />�N = co <br />co <br />C) <br />LU <br />Q <br />to <br />so <br />o <br />U- <br />21 E� <br />- <br />�R <br />?® <br />p <br />ro @ <br />~ <br />? <br />fa <br />Z <br />❑a <br />UO <br />80 <br />z <br />O <br />N I— <br />0 <br />Qi <br />o <br />wz <br />0` <br />¢ <br />CO C: <br />Z. <br />z <br />z <br />- <br />�w <br />p <br />Zgo <br />d U <br />W <br />a <br />U <br /><o <br />mw <br />�k <br />NJ <br />`� <br />oa <br />a <br />0- <br />U <br />am <br />0,11t <br />J <br />LOLO <br />Q <br />c� <br />j T CID <br />co <br />Y <br />C Y <br />T <br />M <br />mLO <br />a[ <br />0 N <br />O) <br />N <br />am^ <br />04I <br />N <br />r <br />L <br />M <br />Q <br />E <br />T N <br />2 <br />E M `� <br />£ >v <br />C <br />_ <br />a <br />0 -j <br />JOB <br />NO : 22-08313 <br />SCALE: AS NOTED <br />SHEET NO. <br />D 1 <br />