My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6384 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6384 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:35:07 PM
Creation date
2/19/2025 11:40:31 AM
Metadata
Fields
Template:
Building Plans
Street #
6384
Location
Ten Acre Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
5546
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed Joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed U180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7, 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and AC1530 <br />10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12, Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load Applied horizontal load • O <br />a e vertlCa load + Safe horizontal load <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />UV Wiwi <br />Mom <br />o 'o �' r`-Wml <br />�Q= <br />• • • • <br />,J 1 1' <br />.. W <br />817441B/1T8F401B/1T 8RF400B/1T 8F321B/1T <br />FORM & GROUT SOLID <br />4 ••. NW � J <br />�U <br />O #5 BAR CONT. <br />8F12-16/1T <br />'V' LINTEL DETAIL <br />SCALE = N.T.S. <br />I; <br />TYPE DESIGNATION <br />F = FILLED WITH <br />GROUT / U = UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />Q <br />W <br />8 F 16- B/ 1 T <br />U <br />to <br />o <br />tNOMINAL. <br />QUANTITY OF <br />WIDTH #5 REBAR AT <br />TOP <br />NOMINAL- <br />o <br />HEIGHT <br />MATERIALS <br />cTf precasll'mtels = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />#5 REBAR <br />MIN. <br />AT 1)REQ' <br />(t) aD D <br />ILAR <br />ALTERNATE POWERS <br />STEEL LINTEL <br />a <br />#5 REBAR AT TOP <br />° <br />° <br />me C.M.U. <br />° <br />GROUT <br />MIN. (1) REQ'D < <br />1.1/2" CLEAR <br />° <br />° <br />° <br />5 REBAR AT <br />BOTTOM OF <br />= in Z - <br />rn <br />ai <br />LINTEL CAVITY <br />L) <br />W <br />Xw <br />-BOTTOM <br />O W CU Z <br />REINFORCING <br />PROVIDED IN <br />LINTEL <br />¢ C� Zi <br />Z O w ,� <br />¢ Cr i� <br />REBAR AT BOTTC <br />•5/8"ACTUAL <br />DMINAL WIDTH <br />(VARIES) <br />y ¢ a <br />AS INDICATED <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturers specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturers specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel planidetails for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION a@ ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />2x8 #2 SYP STUDS @ 8" O.C. W/ (2) USP OR <br />SIMPSON MSTAM36 STRAPS EACH STUD ((1) <br />STRAPS EACH SIDE) CENTERED W/ (13) 10d <br />NAILS & (8) Y4"x1 J" TAPCONS OR TITENS <br />'CENTER OF STRAP @ T/WALL TYP. U.N.O. <br />2x8 #2 SYP P.T. BASE PLATE <br />W/ Y2" EPDXY ANCHOR OR Y2" <br />J BOLT W/ MIN. 7" EMBEDMENT @ <br />32" O.C. & 6" FROM EACH END <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE PLAN <br />I I T/VVALL <br />161, <br />8" KNOCKOUT COURSE <br />W/ (1) #5 CONT. <br />SEE PLAN FOR FILLED CELL <br />SPACING <br />WALL SPLICE DETAIL <br />REVISED: 11/04/19 SCALE: 1" = V-0" <br />Q <br />8'-0" LL <br />O <br />4'-6" LL <br />O <br />4'-6" LL <br />B <br />MIN. <br />5'-8" LL <br />O O <br />13'-0" LL 5'-10" LL <br />(DMIN. <br />17'-4" LL <br />LINTEL PLAN-B <br />SCALE: Ya"=V-0" <br />N <br />C%j <br />N <br />00 <br />N <br />o <br />CDW <br />.L.+ = <br />a r, v <br />K <br />12 <br />y m v cc <br />..CC Y <br />'" <br />a. .. c <br />� ca <br />c <br />co 0 <br />aC <br />i11i1MMiarrrri,•�i <br />:,,, <br />w�• 0 <br />•" �� S E ' <br />r <br />VL Z_4 <br />S•S ,ON <br />To the best of the Engineers knowledge, information and belief, <br />the sWctural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />o g 8 <br />o <br />0 <br />Q <br />� <br />� C') qLL <br />JLLLL' LL W <br />a <br />- a <br />Z <br />r <br />f� <br />tONr_o <br />W <br />y�Oj m w <br />Z IL LL <br />0 <br />N M Z <br />Z <br />OU 0 <br />W <br />U� <br />Ur cn V <br />Z 5N5� <br />Z 3S <br />Z g <br />� <br />Q <br />U) in <br />N <br />Z i <br />U <br />/r-r'� <br />('y <br />W <br />� <br />U <br />0 <br />W <br />U_ <br />Q <br />Q ora <br />c <br />to <br />W <br />Ir■ <br />co <br />g <br />� <br />�o <br />Wo <br />�� <br />o0za <br />a <br />U <br />H <br />Ru <br />oa <br />US <br />Zoe <br />oaL <br />� � <br />8 <br />1z <br />�a <br />C <br />2O <br />Z <br />rfi <br />rNir <br />d <br />•<- w <br />g <br />z <br />az <br />W <br />a <br />U <br />w <br />�W <br />ca <br />O <br />CID <br />�w <br />¢o <br />o� <br />O <br />co <br />O <br />c� <br />N <br />L <br />0) <br />CO r <br />a. <br />m <br />N <br />LO <br />N <br />a) <br />N <br />N <br />Lo <br />Q <br />� <br />T <br />ui <br />cc <br />4^ <br />N <br />^ <br />c <br />z <br />� <br />Q <br />N <br />v <br />cc <br />c <br />m <br />a <br />.. <br />U <br />JOB <br />NO: <br />22-08308 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />7 <br />�z <br />c <br />W <br />7 <br />