My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6384 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6384 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:35:07 PM
Creation date
2/19/2025 11:40:31 AM
Metadata
Fields
Template:
Building Plans
Street #
6384
Location
Ten Acre Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
5546
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Vf11+ I !t Rvr1<II�II PR9.+�11�If+llllh'111111N�1' For J y Ii' nl Ip' IAllll�Il■ 1 IIII I '�!' <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />7 <br />200 amp <br />150 amp <br />UNDERGROUND [Dis <br />SERVICE BY POWER CO.—�� <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 <br />NEMA1 <br />150 AMP/ <br />200 AMP <br />to lights & outlets <br />to appliances and GFI <br />to WH <br />o Range <br />o HVAC <br />200=4/0 in 2" Conduit <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES. Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance With the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoketcarbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />FiiP <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />CH <br />PB <br />SD <br />CM <br />USB <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />1.5" VTR <br />SWITCH <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />DEDICATED <br />RECEPTACLE FOR <br />CROWAVE RANGE <br />HOOD PER SPECS <br />SPEC 3 & 4 KITCHEN <br />SCALE: %4'=1'-0" <br />WP A/C PAD <br />GFI DISC. <br />A — <br />/V <br />ENTRY�P <br />DB & GFI TO I GFI <br />BE ALIGNED — — — — — — — <br />VERTICALLI'� <br />I <br />I <br />1 <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />X X <br />W W <br />WLU <br />J <br />�O� <br />m <br />�UI=— <br />� O� <br />COACH LIGHTS I/ COACH LIGHTS <br />OR PREWIRE AS \ OR PREWIRE AS <br />PER SPECS \ / PER SPECS <br />FIRST FLOOR ELECTRICAL PLAN-B <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />L----------- I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -d <br />SECOND FLOOR ELECTRICAL PLAN-B <br />c <br />O <br />" <br />-o := <br />W -o <br />C ce c.� eat <br />O X <br />y V O <br />a� y <br />a <br />c � <br />�o <br />a� <br />0 <br />N <br />O <br />N <br />N <br />ti <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0 <br />F o E <br />a $ <br />to <br />32 <br />2 - <br />di cr <br />ik LL <br />J LL LL <br />LL d <br />Z —vim <br />M CS <br />a. 2 <br />W :3� & Z; <br />� 0 <br />Z cc <br />ILW W�O'a' <br />to M Z <br />m w <br />d <br />J <br />,n N <br />VIL <br />O U <br />U <br />= <br />W <br />00 <br />0 <br />Z N � <br />z <br />v <br />J— <br />d � <br />aE3 <br />tV <br />� z <br />W <br />)(10 <br />O w s <br />N Ly N <br />N 5_ <br />In <br />�— <br />U c <br />L.Lr J <br />r E <br />8 <br />_ � <br />�Q <br />• <br />U o <br />� <br />C ' <br />Q m � <br />N <br />o <br />W <br />M <br />= <br />� <br />ZM <br />� <br />E <br />gD <br />C � <br />LJ <br />w� <br />go <br />tC <br />C <br />O <br />00 <br />Z <br />� <br />N <br />i <br />a <br />wg <br />Ww <br />�? <br />CO <br />_, <br />UZ <br />�g <br />0 " <br />Z <br />� <br />Q� <br />$ <br />Z <br />a0Z <br />C <br />'2 <br />�W <br />W <br />w <br />o <br />W <br />U_ 0 <br />>° <br />O <br />w� <br />zla� <br />ar <br />$ 3 <br />y0 <br />>M <br />� <br />O <br />m <br />c9 <br />CID r <br />O <br />T <br />T <br />Cr <br />U) <br />N <br />on <br />Ln <br />�+-+ <br />O <br />N <br />N <br />CD <br />Q <br />T <br />i►i <br />N <br />7 <br />c <br />Z <br />W <br />Z <br />N <br />E O <br />E v m <br />c <br />c <br />a <br />0 a o <br />'i <br />JOB <br />NO: 22-08308 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.