Laserfiche WebLink
::t_ <br />LO <br />LO <br />0 <br />1:71 <br />V) <br />:0 <br />_n <br />9 <br />;Z4 <br />cl <br />V) <br />a, <br />_G <br />C <br />CL <br />E <br />E <br />0 <br />LZ <br />E2 <br />-0 <br />E! <br />2 <br />CL <br />01 <br />Q <br />C14 <br />�J <br />1Z <br />LO <br />U") <br />177 <br />THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3/8" CEMENT <br />PLASTER <br />12 MIL DRY5LOK <br />CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />1) SEALANT AT <br />4) SEALANT JOINT <br />WINDOWBUCKTO <br />OUTSIDE EDGE OF <br />MASONRY <br />WINDOW BUCK- <br />/-2) SEALANT JOINT <br />5)SEALANTFROM <br />INSIDE EDGE OF <br />WINDOW FRAME <br />WINDOWBUCK <br />ACROSS WINDOW BUCK <br />ANDEXT DTO <br />EN <br />-ViANDOWFRAME <br />MASONRY <br />ATTACHED <br />PER CODE <br />6) TOOLED SEALANT <br />ED S LANT <br />REQUIREMENTS <br />BEAD BRIDGING <br />�ID�GING <br />NG AND WINDOW <br />CLADDING AND WINDOW <br />FRAME <br />3) SEALANT WINDOW FRAME T< <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SILL. <br />SCS 06 05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />"V'SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />SCS 06 02 WINDOW FIN INTERFACE WITH <br />EXTRUDED SHOULDER <br />WEATHER <br />RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTI( <br />1 . Cut, fold up & temporarily secure, <br />resistive barrier above header to allow tor <br />flashing installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />Scale: NTS <br />SELF -ADHERED FLASHING <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />G <br />SELF -ADHERED FLASHIN <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />as(Refer to the number marked OP in each detail that corresponds to the <br />numbered items in the list instructions below: <br />1 . Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />NAILING FLANGE <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />2x FRAMEWALL <br />TILE FINISH <br />1/2" DUROCK- <br />8" CMU <br />4" OR 8" CMU <br />(PER SEAT DEPTH) <br />FILL WITH GROUT - <br />SLOPED MUD BED - <br />VINYL SHOWER PAN <br />WEATHER <br />VE BARRIER & <br />ZARILY SECURE <br />WOOD FRAME CONSTR. <br />EXTERIOR SELF -ADHERED FLASHIN <br />SHEATHING BY LAPPING DOWN ­, <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER <br />SEAL TOPS OF JOK <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />ED FLASHING <br />SELF -ADHERED FLASHING <br />E <br />kM <br />1'4" PER PLAN <br />V-0" PER PLAN <br />SHOWER SEAT <br />4 <br />WEATHER RESISTIVE <br />BARRIER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />'N <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />I <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WPO-7� <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF-ADHEF; <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />LU <br />> <br />< <br />Lu <br />CL <br />1-- <br />X: W <br />LD LLJ <br />0 <br />LJ LU <br />Lu <br />LU <br />a) <br />0 <br />U) <br />DOOR ROUGH OPENING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6". USE LIQUID <br />NAIL BRAND OR EQUAL WEATHER <br />PROOF CAULKING <br />SELF -ADHERED FLASHING <br />SUBFLOOR <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED \AnNDOVV <br />(SEE DETAIL WP011) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />!LF-ADHERED FLASHING <br />TCH <br />HERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />PLASTER STOP <br />CONTINUOUS BACKER - <br />ROD & SEALANT <br />WINDOWUNIT <br />FLASHING REQUIREMENTS <br />SLOPE <br />0.3 in : 12.0 in <br />R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />(0.6 cm: 30.5 cm) <br />include flashing as described in Section R703.4. <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of <br />CEMT. FIN. <br />water within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means <br />BUILDING PAPER <br />of draining to the exterior water that penetrates the exterior cladding. <br />>< <br />WIRE LATH <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type I felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied <br />horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less then 6 <br />inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The <br />No. 15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and <br />building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over <br />wood -based sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade <br />V <br />D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />substantially nonwater-absorbing layer or designed drainage space. <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />RUBBERIZED <br />NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />THROUGH SELF -ADHERED <br />R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be <br />FLASHING <br />SELF -ADHERED FLASHING <br />applied shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied <br />membranes used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to <br />SCORED <br />prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER <br />Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />(BEFORE FOLDING, SCORE <br />the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />2�� <br />shall be installed at the following locations: <br />1. I.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />2 <br />following: <br />5 <br />1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />4 <br />manufacturer"s instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />are not provided, p an flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />6 <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for <br />7 <br />subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />SELF -ADHERED FLASHING <br />1.3 13. In accordance with other approved methods. <br />INSIDE CORNER <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMAANDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground <br />3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6.6.At wall and roof intersections. <br />Water Resistant Barrier <br />7. 7.At built-in qutters. <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />THIS, <br />NATU <br />DO Ni <br />DRIP <br />ACCE <br />SOFFIT/CANTI LEVER <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) <br />BOND BREAK WEATHER RESISTANT BARRIER <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING, 'OSB', PLYWOOD, DENSGLASS_ <br />FRAMING <br />SHEATHING <br />ANE WRB <br />WRB <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMCI 063 <br />Building Paper <br />-7/16" O�S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />< XX <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />eWEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" 0. S. B. <br />sheathing <br />Stampede or similar <br />caulk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />C_J <br />% <br />Cn <br />C3 <br />'J <br />> LU <br />cc <br />C�4 <br />C= CU <br />E <br />C2 <br />LJ% <br />C4 <br />C4 <br />(=0 <br />C=:) <br />To the best of the Engineer's knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only fo <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and see[. <br />W <br />MNft I- <br />It E <br />5038 <br />U) <br />I � C b -,,, <br />co c: cc <br />0 C`1 <br />N 0 <br />C L� <br />_J Lu <br />(D u_ U_ . a. <br />0 <br />Z <br />0 <br />_J W <br />2 S <br />i <br />E n W <br />Z = 9 0 <br />a N <br />:5 F <br />W <br />0 2 <br />co <br />Z <br />IL <br />IL <br />U-) Z� Z0 <br />co <br />a <br />CN � < <br />do <br />Z <br />0 co <br />W <br />11 El <br />0 <br />:2:: <br />93 1 <br />< <br />V) <br />(1) <br />(D <br />0 <br />4---' <br />ro <br />- <br />co <br />LU <br />0 <br />U1 <br />LL.1 <br />U') <br />3 <br />A <br />U) <br />MINE <br />8 <br />U U) <br />< 0 <br />14 <br />ff IF <br />Z <br />U_ <br />E <br />Ei <br />� R" <br />E 8 <br />WW <br />O� <br />-73W <br />AV, <br />E <br />z <br />0 <br />Z <br />�z <br />= C <br />C/) <br />1' <br />, <br />'0 <br />0, <br />Z, <br />0 <br />�z <br />2. <br />Cn <br />9) <br />0 <br />- Z0 <br />Q_ <br />0 <br />W <br />5. <br />-,3: <br />miC� <br />S <br />C) <br />LO <br />LO <br />cc <br />(D <br />CY) <br />J 04 <br />N <br />Cr <br />T_ <br />LO <br />4-J <br />4-J <br />0 <br />C'4 <br />N <br />0 <br />c) <br />Ir- <br />C0 <br />L0 <br />E <br />0 <br />Z <br />Z <br />E cle) <br />CAP <br />a) <br />a <br />ca <br />E <br />0 0 <br />-8 <br />r_ <br />CD <br />I <br />JOB <br />NO <br />22-06472 <br />SCALE <br />AS NOTED <br />SHEET NO. <br />WP <br />