Laserfiche WebLink
ELEV AT 8'- <br />T.O.M. <br />ELEV AT 0'- <br />1 ST FLOOF <br />SHINGLE R( <br />ELEV AT 8'-0" <br />T.O.M. <br />5/8" STUCCi <br />OVER CMU <br />ELEV AT 0'-0" <br />71, 1ST FLOOR FF <br />FRONT ELEVATION B <br />1 /4" = 1'-0" <br />REAR ELEVATION B <br />1 /411 = 1'-0" <br />12 <br />5 <br />SHINGLE ROOF <br />1 1/4" THK x 6" <br />STUCCO BAND <br />5/8" STUCCO <br />OVER CMU <br />ELEV AT 8'-0" _ <br />T.O.M. <br />75/8" STUCCO <br />OVER CMU <br />00 <br />CID <br />2'-0" <br />ELEV AT 0'-0" _ I <br />1ST FLOOR FF \ �— <br />RIGHT ELEVATION B <br />1 /411 = 1'-0" <br />ELEV AT 8'-0" <br />7-1 T.O.M. <br />75/8" STUCCO <br />OVER CMU <br />ELEV AT 0'-0" <br />1ST FLOOR FF <br />00 <br />io <br />LEFT ELEVATION B <br />1 /411 = 1'-0" <br />7 I <br />A5 I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I <br />ROOF FINISH <br />PER ELEVATION <br />ROOF SHEATHING <br />MANUFACTURED <br />ROOF TRUSS <br />MTL DRIP EDGE <br />ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />,IOVERHANG DETAIL <br />a <br />ROOF FINISH PER <br />ELEVATION <br />ROOF SHEATHING <br />' <br />» <br />MANUFACTURED <br />ROOF TRUSS <br />METAL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINIUM WRAP <br />PER ELEVATION <br />ALUMINUM <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />OVERHANG DETAIL <br />6 <br />_ A = <br />- <br />!;NCMU COLUMN DETAIL <br />r <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM 'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />* EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />NOTE: <br />FOAM TO BE USED ONLY WHEN <br />REQUIRED BY COMMUNITY JUN 1 <br />SPECS. IF NOT, DETAIL TO BE <br />BUILT W/ STUCCO T ueview Assisi <br />,.I Review Assist, Inc. <br />unc; :w ew completed a <br />n J <br />nth the 20 <br />r I' <br />;1ttc,.;1 t)v Gej, ,�,r, �e Kla <br />11 <br />' ELEVATION DETAILS <br />8 Ate-1-111, <br />5/8" STUCCO <br />FINISH ---- <br />2" 6 L VARIES <br />(V <br />(V <br />ASSUMED GRADE <br />9 ELEVATION DETAIL <br />1 1/4" THICK <br />I �LI <br />m7 y s' <br />N <br />o <br />o <br />P <br />L0 <br />7 , <br />O <br />w <br />0 <br />z <br />Q <br />^` <br />W <br />K E <br />L '� .gyp `''• o <br />C) M N m <br />} <br />N <br />UDII� �M <br />-070 °0 m ai <br />E - MMp <br />O U O <br />0 <br />._Cu <br />6�} <br />V W �N C <br />EM <br />W <br />L 0 rn <br />N CW-^J <br />o w w 0 <br />W< W.2_j Wg z <br />O <br />1.L U <br />H <br />j 8 R J w x 0 2 2 0 0 <br />awo ww—z wFnw Z: <br />Q P <br />0 <br />C�'1 0O Z <br />a inww z XQ <br />Q�a0WQ�zWz0W°oa <br />LL <br />Ow �I-F zsYOQQ <br />0X o D oQzx <br />Qw <br />Q <br />LLQ 0 <br />>f <br />O <br />Z W <br />0� <br />MO <br />Q u) CM � <br />2U)�ti <br />H W a- M <br />WCL2� <br />Z 0 <br />W <br />W <br />JC:) <br />0 <br />J <br />202 <br />a VOd <br />FBC 7th <br />X2300 <br />I <br />C <br />O <br />O <br />o <br />coo <br />NO <br />N <br />N <br />N <br />M <br />N <br />0 <br />N <br />O <br />1 <br />0 <br />W <br />o <br />o <br />I <br />1 � <br />00 <br />} <br />ZZ <br />U) <br />Q z <br />w <br />O <br />go <br />4- 0 <br />0 <br />W <br />_ <br />W O O <br />U <br />U U <br />O <br />::)Z> <br />owo <br />o� <br />Q <br />O <br />Z <br />I— <br />a <br />a <br />L�) <br />= <br />W <br />mitW <br />F- <br />_ <br />ZF-o <br />o = <br />■ ■ <br />W <br /><U) <br />M <br />Q <br />Z <br />C) <br />gwwx <br />az w <br />Z <br />LnZ <br />F� <br />pV <br />_o <br />W <br />z <br />Z <br />z <br />w <br />W-1 <br />Cov/ <br />T <br />N O <br />LAST PLOT DATE <br />• <br />April 22, 2022 <br />z 0 <br />J <br />EXTERIOR <br />ELEVATIONS B <br />