Laserfiche WebLink
M% 311Az111-DADS ce3LT M' <br />• PRODUCTCO..MMO . SECTION <br />n 1 W_ SW 26 Swe K Roost 202 <br />DEPARSLIENTOFREGULATORY A:NDECMV03DC RESOUR-CES(RER) %in= Florida 33 1.73-N74 <br />BOARD A 'D CODE AD3rID.`IST1RATIOX IYMS 0-N T (-j 3 n = 590 F t-S4) 3] i-2 S99 <br />NOTICE OF AC"CEPTA- CE CNOA) rrartc_m sindede,"t':weeosar <br />PGT Industries, Inc. <br />1070 Iecl a&gy Dort, <br />-North Venice. FL 34275 <br />SCOPE: <br />This NOA is being issued under the applicable rules and regubtieaas gory euiing the use of construction materials. The <br />documentation submitted has been re-nea-ed and accepted by;1 -Dade County RER -Product Cow Section to <br />be used to Miiami Dade County aW otherareas mere allowd by the Authority 1 taavw;g JtuisckcUm (ART) <br />This NOA shall not be valid after the expuatum date stated below The Mtauu-Dede Cousfy Product Centro Section <br />(in Manii Dade County) andorthe AHJ (m areas other dean. iiami Dade County) reserve the right to have this <br />product or ma a i.al tested fee quality a e pugmes_ If this product or material fails to perform in the accepted <br />mattner.the anu faetitrexwrddincurtheexpense ofsuch testing and the AllJmay immediatety rev oke.modify. or <br />suspend the use of such product or material within their jurisdiction. RER resea°n=es the right to ren°oke this <br />acceptance. if it is determined by Mianu-Dade CountvProduct Coamvd Section that this product or maternal fails to <br />meet the requireements of the applicable being cock_ <br />This product It, approw<1 as described herem and has been designed to comp4,with the Florida Building Code. <br />inn huling the High Velocity Hurricane, Zx me <br />DESCRIPTION: Series " 5570t.770" Vinyl Sliding Glass Door (Reinforced) wtwo 900 & 13.O corners-LAH. <br />APPROVAL DOCT27NT: Drawing No. 310D-55"0.0 Rev B. titled -Vutvi Sliding Glass Door NOA (L-M)' . sheet <br />1 through 21 of 21_ prepared by mamifwtum. dated 10.L'Q5•15 and last revised on 021!01. 2I. signed and sealed by <br />A. Lyme l%filler. P.E.. bearing the Nis i-Dade County Product Control Revision stan3p with the Notice of <br />Acceptance number and expiration date by the 43iarni-Dace County Product Control Section. <br />Missni Ny-m:1 RkTI Gr Large and Small '►Ii rile Impact Resistant <br />Limitations: <br />1. See table 1 (sheet' I and table 2 (sheet §) for apphcable SGD unit sew. design ptesnwes- reinforcements types. <br />glass types. sill riser ( see tables B-1 & B-.. sheets ; -8) and anchor layout sheets regwene nts in 11 thru 16 <br />?. Rigid tt'h.ite PVC. Tani (Non-uliite) Rigid PVC and Brown coated (Paused or laminated) w1ute Rigid PVC to be <br />labeled per referenced NOA" s rev(' s. <br />3. Ewes, <br />operable doors roust c emply- with rain clear wuM or height per FBC re gUiaement as applicable <br />.1. Poercet walh under separate approval to be renewed by Building official <br />LABELING. Each unit shall bear a permanent label with the manufacturer's name or 1v to, city. state azrd serifs aril <br />following statetaoenL "N iami-Dade County Product Cool Approved", taowd herein. <br />REN-E ':tL of this NOA shall be cousid.ered after a renewal applic3hon has been filed and theme has been no <br />change in the applicable binding code negatively affecting the petfcance of this prct <br />TERIW%�ATION ofthis NOA will occur after the expiration date or if these has been a revision or clianew in the <br />materials. use. and'ormaunfactune of the product or ptocess. siisuseoffNOAasanendorsementofany product. <br />for sales, advertising or any odxf purposes shall automaticallyterminate this NOA. Failure to convly with any <br />w don of this NOA " be c avw for terminakou and removalofNOA <br />. <br />ADVERTISE -NE N?: The NOA number preceded by the words A harm -lade Coeurty. Florida. and toItowed by the <br />expiration date maybe displayedmn advertising literature- Ifanypertiotnof the NOAis displayed. then it shall be <br />done in its entirety. <br />LN 5PEC7ION : A copy of this entire 'NOA shall be pro -tided to the user by the niamtfactuter or its distributors and <br />,.hail be available for inspection at the,lob site at the reqmt of the Builder Official. <br />This NOA revises fir reams NO A020-04?9.05 and consists of this page l and en•idencepages E- 1. E-2_ E-3- E 4. <br />E-5 & E-6 as well as aplaroval docunient mentioned abopkxe. <br />The submitted docunwa atice was reviewed by Ishaq L C Banda, PE. <br />NOA No. :1-tt:©=.tf <br />. Expiration Date; April I4. 2026 <br />ApprotralDaloOklareb M1.01..1 <br />Page 1 <br />PGT Industries. Inc. <br />NOTICE OF ACCEPTANC'E: EVIDENCE StB'NIITTED <br />2. ENIdence Submitted under precious submittal <br />V. DRANVINGS <br />I. Drawing No. ' 1D-5570.0 Rev B_ titled "Vinyl Sliding Glass Door NOA W". sheets <br />1 through 21 of 2 1. prepared b� manufacturer. dated 10,05!15 and Last revised on <br />O- 210. signed and sealed by A. Lynn N-filler- P.E. <br />B. TESTS <br />1. Test reports on: 1) Air Infiltraticm Test. per FBC. TAS 202-94 <br />2) Uniform Static Air Pressure Test. Loading per FBC. TAS 202-94 <br />3) Water Resistance Test. per FBC. TAS 202-94 <br />4) Large Missile Impact Test per FBC. IAS 201-94 <br />-5Cyclic Wind Pnsswe Loadingpeer FBC, TAS 203-94 <br />along with marked up drawings and instahlation diagram of all PGT Industries, Inc. <br />representative units listed below and tested to qualify- Dowsil 791 and Dowsil 983 silicones. <br />prepared by Fenestratiou Testing Laboratory, Inc.. Teo Reports No.. <br />FTL 7897, PGT PW551-0 PVC Fixed Window (unit 6 in proposal). dated 09.03.14 <br />FTL-24-2107.1, PGT SGD780 Alurumism Sliding Glass Door (unit 7 in proposal) FTL-20- <br />2107.2, PGT CA740 Ahmi Outswing Cast Window (unit 8 in proposal) FTL-20- <br />2107.3. PGT PA'7620A Aluminum FLr&d Window (unit 9 m proposal) and FTL-20-2107.4. <br />PGT PW7620A Aluminum Fixed NVindow (unit 10 in proposal) dated 0713/20. all signed <br />and sealed by Idalmis Ortega. P.E. <br />C`. C_ALCULATIO:NS <br />1 Anchor -verification calculations and structural anah-sis. complying with FBC 71b <br />Eden (2020)- dated 04.22,20. prepared by nanuifactuIe r__ signed and wed by <br />Anthon L-ynn Rom, RE <br />'_. Gluing collies with AST"M E 1300-04. -09. -12 and -16. <br />D. QUALITY ASSU' kNCE <br />Miami -Dade Department of Regulatory and Economic Resources (RER). <br />E. 31ATERLkL C:ERTUICATIONS <br />1. Notice of Acceptance No.19-030.4.02 issued toKularay America. Inc. for their <br />`°Trosifolt U'ltraclear. Clear. and Colo • P1B Glass Interlay+ers.. expiring on <br />OT08..24. <br />2. Notice of Acceptance No.17-0803.02 issued to Kuraray America. Inc. for their <br />"Senni-GlasI (Clear and White) Glass Interlayon . expiring on 01.:04/2-3. <br />3_ Notice of Acceptance No. 18-1106.10 issued to Vision Fixtru ions Lmnited for their <br />"Brown Coated (Painted or Laminated) White Rigid PVC Exterior Extrusions <br />for tt'Indows and Doors"". expiring on 09,30=24_ <br />4. Notice of Acceptance No 18-11H.11 issued to Vmon Extrusions Limited for their <br />series " VE 1000 Tarn 202 and lighter shades on-Rhhe) Rigid Cellular PA-C' <br />Exterior Extrttsmns for Windows and Doom". expiring on 12 29121. <br />Ishaq I, Cttaanda. P.E. <br />Product Control Unit S perriiot <br />NOA Na.:1-8:09.03 <br />Expiration Date: April 14..1026 <br />ApproviI Date: Alareb 2=, 2021 <br />E4 <br />PGT Industries. Inc. <br />NOTICE OF ACCEPT N'C'E: EVIDENCE SUB.AMTED <br />1. Evidence submitted under pretious NOA <br />A. DRAMTNGS <br />1. Manufacturers, die drawings and sections. <br />(.Serb mitred it nde'r N0.4 :1 o. 11-010" 04) <br />?. Drawing No. MD-5570.0. titled "Vinyl Shding Glass Door NO A (Lldy' sheets 1 <br />through 21 of? 1. prepared by maaufacturer. dated 10,05 15. with muion A dated <br />04,05,17. signed and sealed by A. Lynn Miller_ P.E. <br />B. TESTS <br />1 _ Test report on 1) Uniform Static Air Pressure Test.. per FBC. TAS 202-94 <br />2) Large 21-1viissile Impact Test per FBC. TAS -203 -94 <br />3) C-Yxhic Wind Pmsure Leading per FBC. TAS 2 3-94 <br />aitYng with niaritrd-up drnwittgc� anal inciaitatirm aliagrnni cif,, inyl Olding ftm; it,Nw prrare A <br />by Fenestration Testing Lab. Inc.. Test Iteport'v'o. FTL 8"1', dated 1_' 07'I signed and <br />scaled by Idalmis Ortega. P.E_ (Test report revised on 02 15:16 and 02 24-1 d) <br />?. Test report on 1) Air Infiltratiou Test. per FBC. TAS 202-94 <br />2) Uniform Static AirPresstme Test. per FBC. TAS 202-94 <br />3) Water Resistance Testa per FBC_ TAS 202-94 <br />4) Large l issik Impact Test per FBC. TAS 201-94 <br />5) Cyclic Wind Pre.sure Loading per FBC-. TAS 203-94 <br />6) Forced Entry Test. per FBC'. TAS 202-94 <br />along witted up drawings and installation diagram of.nf1 sliding guess boor. Orr <br />by Fenestration Testing Lab. Inc._ Test Report No. FTL 8546. dated 1106 l 5. Signed and <br />sealed by Idalmis Ortega. P_ E- (Test report reA iced on O1.04 16 anti 02'11 2016) <br />3. Test repast on 1) Air Infiltration Test. per FBC. TAS 202-94 <br />2) Uniform Static Air Pressqre Test. per FBC, TAS 201-94 <br />3) Water Resistance Test. per FBC". TAS 202-94 <br />4) Large Llissile Impact Test per FBC_ TAS 201-94 <br />5) C'yxhc Wald Pressure Loading per FBC, TAS 203-94 <br />d) Forced Entry;• Test. per FBC. TAS _102-94 <br />alter withmaiked--up drawings and installation diagram of %-.nyl sliding glass door. prepared <br />by FewsTraftion Testing Lab, Inc_ Test ReportNo FTL 85.17_ €Dated. 1-1,04115 signed wid <br />sealed by Idahn s Ortega, P. E. Vest report mised on 02 15 16) <br />4. Test report on 1) Airl:edtration Test. per FBC. TAS 102-94 <br />2) Uniform Static Air Pressure Test_ per FBC. TAS 202-94 <br />3) Water Resistance Test. per FBC. TAS 20' 04 <br />) Lame Fissile Fact Test per FBC. TAS 201-94 <br />5) Cyclic Wind Pressure Loading per FBC_ TAS 203-94 <br />6) Forced Entry Test, per FBC. TAS 202-94 <br />along w ithnamed-up drawings and installation diagram of tinyl sliding glass door. prepares <br />by Fenestration Testing Lab. iric._ Test Report No. FTL 8548. dated 12 6- -15. signed and <br />sealed by Idalmis Ortega. P E (TTest report revised out 0104`16 and 02 11.16)). <br />lahaq L Chanda. P.E. <br />Product Control Unit supervisor <br />NOA No. 21-G20.03 <br />Expiration Dart: April l4.10!6 <br />Apptoa gat Date: _Xbirch 2f, 20:1 <br />E -1 <br />CGI Windows and Doot_s. Inc. <br />NOTICE OF ACCEPTANCE: EVIDENCE SUB -NUTTED <br />E. aL-kTERLAL C=ERTIFIC ATION S (continue) <br />5. Qtuanex Part Surer Spacer° Standard complyme with AS -A. I C 51S Tliernnnal C°onductr} ny <br />0.881 BTU-im hr.-ft=-°F„ AST%M F 1'149 VATTR-Pass. ASTRI D3985 Oxygen--Pass..AS M E <br />2190 I.G_ Dtuabihty-No Fcig-Pam. t•i'ubrrrtr d rrrarler r tt rrs t1.4 : ,15-0409.0i <br />6. Q ianex Pan Dura comps with ASTINI C:51 S Thermal Conductivity 2.22 BTt'-in <br />inn.-fr=-`F. ASTlIe 1I F 1249-Pauas. AST <br />Ri D 1434 Argon Perneance-Pass. AST 1 E <br />2'189 I.G. Durability -No Fog. ASTM E 4d Dew Point Development -20*F w 48 hi. <br />(-Snbytlue d ander VOA N'v. 15-0409.05). <br />7. Vision Extius-ion& Ltd. Parts e:omph ng with PVC'-AA_XL4. 303-13. Voluntary Specification <br />for Rigid Pol -%,-m I Chloride (PVC) Exterior Profiles for.1.71sion Extrisio - Ltd.--VEX-1 b,:- <br />AAMA Fenestration Exterior Profile Certification Pro (Submine3ei under NO-4 No. 1 - <br />0409.4S) <br />8. Vision Extrusions, Ltd. Parts complying with PVC .A'tL 303-13. <br />lSubutirred rnrde►r N0A A-o. 15-0409.OS) <br />9. PVC-AARIA 303-13. Voluntar Specification for Rigid Polyvinyl Chide (PVC) Exterior <br />Profiles for Viswn Ertrusiems. Ltd.-T -1 by AAMA- Fenestratiou Fixtenor Profile - <br />Certification Program. <br />10. Notice of Acceptance No- 18--1217.14 issued. to Energi Fenestration Solution. USA. Inc. for <br />their --Tan 3040 S light shade (non -whites) White Rigid PVC Exterior Extrusions for, <br />Windows and Doors". eviring on 02.04,21. <br />11. Notice of Acceptance No. 18-0122.02 issued to Energy Fenestration Solution.. USA. Inc- for <br />their series ' 111lite Rigid PA-C' Exterior Extrusions for 1t`indows and Doors", expiring on <br />0?:28 °23. <br />12. Notice of Acceptance No. 20-0203.03 issued to Enexgi Fenestration Solution. USA. Inc. fror <br />their 'Bronze & tight shade cap coated White Rigid PA-C- Exterior Extrusions for <br />11'indows and Doors-. expiring on 04 16 25. <br />F. STATE11ENTS <br />1. Statement letter of conformance to FBC 7,* Edition (2020). dated 04:21`20. issued by <br />manufacturer. signed and sealed by Anthony Limn 2Milher_ RE <br />2. Statement letter of no financial interest and of independent_ issued by manufacturer_ dated <br />04;18.20. signed and sealed by Anthony I.,ma INliller. P.E. <br />3. Private Labeling Agreement document between PGT_ daieed 03 30 15 and signed by all <br />involved patie& <br />G. OTHERS <br />L This NOA reites'+tOAR 17-0420.i (`TWCGI) and updates toFBC2020 (`u`Edition). <br />expiring 04 21 °21 <br />'_. RER Test proposals *19-1155 dated 01 1020 approved by Ishagi C'hinda_ P _ expuing <br />04414.21. <br />E -; <br />Ishaq 1. Chanda. P.E. <br />Product Control Unit uperri�or <br />NOA No..14'.O...0 <br />Expiration Date- April 14. 2026 <br />Approval Date: March 24, 2U21 <br />NOTIC E OF A(C`EPZ-VSCE: EVIDENCE SUBMITTED <br />B. TESTS(continued) <br />5. Test report on 1 } Air Infiltration Test. per FBC. TAS 202-94 <br />2) Uniform Static -Air Pressure Test. per FBC. TAS 202-94 <br />3) Water Resistance Test. pus FBC. TAS 202-94. <br />4) Large Missile Impact Test per FBC'. TAS 201-94 <br />511 0m is Wind Prey Lire Loading per FBC. TAS 203-94 <br />) Forced Enlr Teel. pet' FBC. TAS 20240=1 <br />along with marled -up drawings andinstallation diagram of ,,mvl sliding glass door, prepared <br />by Fenestration Testing Lab. Inc.. Test Report No. FTL 9549. dated 1106.15. signed and <br />sialed by Idalinis Ortega, P. E. (Test report revised on 12:044 5 and 0-?°11 16) <br />6. Test report on 1) Air Infiltration Test, per FBC_ T.A.S. 202-94 <br />21 Unifoml Static Pressure Test. per FBC. TAS 202-94 <br />3], Water Resistance Test. per FBC. TAS 20_'-94, <br />4) Large Missile Impact Test per FBC. TAS 201-94 <br />Cyclu lit►"ind Presstwe Loading per FBC. TAS 203-94 <br />along with ruarked-up drawings and i tallation diagram ofrinyl sliding glass door. prepared <br />by Fenestration Testing Lab. Inc.. Test Report No. FTL 8552. dated 12,04 15. sighed and <br />sealed bv Idalnm Ortega. P. E. (Testt report rex•ised on 02.15 201) <br />7 Test report on 1 i 1snif'ormn Static Air Pressure Tess. per FBC. TAS 202-94 <br />")Large Niis°sile Impact Test per FBC. TAS 20I-94 <br />3 i Cyclic Wind Pressure Loadingper FBC. TAS 203-94 <br />airing with marked -up drawings and inrtallation diagram of vmvl sliding glass door. prepared <br />b." Fenestration Testing Lab. Inc.. Test Report No. FTL 6638 (Ales A-1 thou A-2 ). dated <br />11 19,10_ signed and sealed by, Jorge A. Causo. P. E. (Srebndired rttrde'r NO 4 .Ve.11- <br />010" 01) <br />8 Test report on 1) Air Infiltration Test. per FBC. TAS 202-94 <br />2) Uniform Static Air Pressure Test. per FBC_ TAS 202-94 <br />3 rVarer Resistance Test. per FBC, TAS 202-94. <br />4) Large Missile impact Test per FBC. TAS 201-94 <br />51 Cy he Wind Pressure Loading per FBC. TAS 203-94 <br />6;) Forced Entry Test. per FBC_ TAS 202-94 <br />along with h marked -up drawings and installation diagram of vinyl sliding glass door. prepared <br />be Fenestration Testier Lab. Inc.. Test Report No- FTL 633 . (samples A-1 thru A-5). dated <br />1..2.06.10. signed and waled by Jorge A_ C"auso. P. E. t.Subinhied under N0.4A-o.11- <br />010' 0) <br />C. C:tLCT-LATIONS <br />1 Anchor verification emulations, and structural analysis, complying with FBC-2014, <br />prey by PGT. dated 12 ,0p 15 and last reed on 02.15:16. signed and sad by <br />Anthony L. l�r, P E. (Snbrta trere�l rrtt de'r _!'0 4 N a.1 5-1 ?I G(01), <br />?. Gluing complies with AST111E-1300-09. <br />Ishaq I. Chanda. F.E. <br />Product Control ' nit Supee•risor <br />NOA No. <br />Expiration Date: April 14, 2026 <br />Approval Date; March :_. 2021 <br />E -: <br />PGT Industries. Inc. <br />3. New Eiidence Submitted <br />A. DRAA1z1;GS <br />1. DraraF= No. tiID 55'0.0 Rey- B. titled "Vinyl Sliding Glass Door NOA sheets I <br />tln.rougln 21 of 21 _ prepared by nianufactut er. dated 16 05 15 and Iasi re ned on 02:011)1. <br />sighed and sealed by A. Lynnn ;Allier. P.E. <br />Note: This re.- ion consists replacement ofsame existing installation screw with flat head, <br />B. TESTS <br />I. 'No e_ <br />C . CALCU7 AT OMS <br />L None_ <br />D. QUALHY ASSURANCE. <br />1. Mianii-Dade Deeper of Regulatory and Economic Resources (RER). <br />E. ltaTERLAL CERTEFICATIONS <br />I. Notice of Acceptance No 19-0305.02 issued toK.uraray America. Inc. fortheir <br />"Trosifolt U'ltraclear. Clear, and Color PVB Glass Interiayer '. expiring on 0TOS.,24. <br />2. N otice of Acceptance No.17-0808.01 issued to Kul arra► America, Inc. for their <br />"Senn GL�s (Clear and White) Mass Interlayesrs". expiring on 07 +IJ4,^"23 <br />3 Notice of Acceptance No.1.8-1106.10 issued to Vision Extru:sions Limited for their ° $r•owrt <br />Coated (Pain od or Laminated) White Rigid PVC Exterior Exrt-inkus for Windows <br />and Doors expirng on 09 30 ,2-1. <br />4 Notice of Acceptance No 18-1106.11 issued to Vision Extrusions Liiuited for their series <br />tB 1000 Tan 202 and lighter shades (Non4lhite) Rigid Cellular PVC Exteror <br />Ext msions for Windows and Dooms"- expiring on,12 229211. <br />F. STATE_11TN TS <br />1 Starenwnt letter of conformanceto FBC "• Edition (2020)- dated 0Ml21, issued by <br />matiuffactucer. signed and sealed by Arnthony Lynn Milner. P.E. <br />2 Private Labeling Agreement dated 03.'Oi'-)I betive,en PGT Industries. Inc. and CGI <br />XV ows and Doom Inc . signed by Dean M. RuaA-, F.E.. V P= Engineering. on behalf of <br />both c mnpanient, <br />G. OTHERS <br />L This N`0A re vises & renews N O A. 4-04 29.05 (PL A w CGI), e.Vit* 04 14 `26 <br />2. The current associated PLA CGI file r-21-0205.01- expiring 0414,2& <br />Ishacq I, e:'hauda, P.E. <br />Product Control I`sit Supersi:or <br />NOA No. 21-0!09-.03 <br />Expiration Date: April 14.:026 <br />Approral Date:-liarch 2«. 2021 <br />E -6 <br />POT industries. Iuc. <br />-NOTICE OF ACCEPI.A2NCE: EVIDENCE SUBM=D <br />D. QUALITY ASSURANCE <br />L Ntiiamni Dade Department of Regulatory and Economic Resources (RER). <br />E. 11ATERLAI. CERTIFICATIONS <br />1. Notice of Acceptance No.1 528.14 issued to Viswn Extrinion Limited for their <br />"11 to Rigid PVC Exterior Extrusions for tt'indow•s and Doors". dated 0&'13,15. <br />ecpiring can 09,130,119. <br />2. Notice ofAceeptance'io.16-0920.08 issued to Vision ExtruswnLmitted for their --NE <br />1000 Tut 202 and lighter Shades (N.-on-White) Rigid PVC Exterior Extrusions for <br />11-mdows and Dooms". dated 12-0&'16. expiring on 12 L)9.,21. <br />3. Notice of Acceptance No.1.."528.15 issued to Vision Extrusion Limited for their <br />"Brown Coated (Painted or Laminated) Mike Rigid Pt-C' Exterior Extrusions for <br />111ndows and Doors". dated 03.13i15. expiring on 09}30.19. <br />4. Notice of Acceptance No.16-0712.02 issued to EN'ERGI Fenestration Solutions USA. <br />Inc. for their --TAN 3040 and Lighter Shades (tion Allitee) Rigid PVC Exterior <br />Extrusions font"htdows and Doors" dated 09,15.46- expiring on 02,104:221. <br />5_ Notice of Acceptance No_ 16-0712.04 is to ENERGI Fenestration Solutions USA. <br />Inc. for their "Bronze and Lighter Shades of C ap Coated Rigid PVC Exterior <br />Extrusions for Windows and Doors" dated 09-1516- expiring on 04.16'20. <br />6. Notice of Acceptance No_ 16-0712.03 issued to E.NER.GI Fenestration Solutions USA, <br />Inc. for their `-tlhite Rigid Pt'C. Exterior Extrusions for Windows and Doors"` dated <br />08.`10i l 7, expiring on 02.21 18. <br />7. Test reportsNo(s). 10-002-792(A). 10--AM0527. 535753-09. perASThiE-84. <br />AST M 1929 and ASTNID-635. issued by EXOVA to Vwon Extrusion for cellulosic <br />composite n3aterial. <br />(Submined rtnderX0-4 1"b. 11-010"04) <br />S. Notice of Acceptance No- 14-0916. 11 wed to Kuraray America.. Inc_ for then <br />"Sena'y Glasg (Clear and White) Interlayer '. a xpirmg on 07. 04 '13. White) <br />9_ Notice of Acceptance No_16-1117.01 issued to Ruraray .kmema. Inc. for then <br />..Trosifol I-Itraclear. Clear and Color PAB Interlayers expiring on 07�08,19. <br />F. STATEMENTS <br />L State nimtnt letter of conformance with FBC-Sdk Edition (2014) and FBC-6* Edition <br />(2017). issued by manufacturer. dated 09,14:177 signed & sealed by Lymn Ruler. P=E <br />2_ Statement letter of no fmancial interest. dated 04' 1 & 17. issued by mom racttu+er. signed <br />& sealed by Lynn hfiller. P.E. <br />3. Letter of lab compliance. part of theabove test reports. <br />4. REK Test Proposal No. 17-0337- dated 05 05417. signed by Ishaq Chanda. P.E. <br />G. OTHER <br />1. Notice of Acceptance No.15-1210.01. issued to PGT Industries. for their Series <br />-'5570,1277r Vinyl Sliding Glass Door (Reinforced) - L.''#,I.K'. expiring on 04 4* 21. <br />Ishaq T. Chasela, P.E. <br />Product C antrol Unit Sap*rri-.or <br />NOA No. 21-020$.0 <br />Expiration Date: :grit 14, 2016 <br />Approval Dare: March 2;, 2021 <br />E -3 <br />VV\ J U N 1 1 2022 <br />7TJAL k VIEW ASSIST <br />Q :view Assist, Inc. <br />:2w co ;sated and app e <br />o cam,. rl ;r ,� ,,t' +he 2020 FB 7th <br />-'itiore rJ, bebrj .Ani-,a Klahr PX2300 <br />Cll <br />Cll <br />Co <br />(D <br />> <br />U <br />o <br />_0 <br />O <br />O <br />CD_O <br />CD <br />-0 <br />Cl- <br />O <br />to <br />O <br />L <br />O <br />Q <br />O <br />0 <br />O <br />U_ <br />CD <br />O <br />Z___ <br />C6 <br />..- <br />O <br />CD <br />> <br />.0 <br />(n <br />� <br />cn <br />CU <br />_O <br />Co <br />1--0 <br />< <br />a <br />z <br />Tr <br />r <br />W <br />�--r <br />(a <br />o <br />L <br />CIS <br />Q <br />Q <br />0 <br />O <br />L <br />co <br />L) <br />m <br />Q <br />sZ <br />CZ <br />w <br />`t <br />z J <br />Z <br />Q <br />0- <br />SHEET N0. <br />PA 1.3 <br />March 15, 2022 <br />