My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6463 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6463 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 3:24:11 PM
Creation date
2/19/2025 11:41:53 AM
Metadata
Fields
Template:
Building Plans
Street #
6463
Location
Beverly HIlls Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
4642
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br />a <br />9 <br />NJ <br />ABBREVIATIONS GENERAL NOTES VERSION CHANGES INDEX OF DRAWINGS <br />ABV - ABOVE MLDG - MOULDING VERSION DESCRIPTION OF CHANGES SHT NO: TITLE <br />THE FOLLOWING TECHNICAL CODES SHALL APPLY: <br />CS COVER SHEET <br />� I�:.�.�, AFF - B VE FINISH FLOOR MNT -MOUNT OR MOUNTING 1.0 PLAN REVISIONS M1 N <br />RE;lz V AHU - AIR HANDLER UNIT MO - MASONRY OPENING Al FOUNDATION PLAN o <br />A/C - AIR CONDITIONING MUNT - MUNTINS 2020 FLORIDA BUILDING CODE RESIDENTIAL, PLUMBING, MECHANICAL, FUEL GAS, 2.0 PLAN REVISIONS N <br />ALUM - ALUMINUM # -NUMBER ENERGY EFFICIENCY, ACCESSIBILITY, AND NFPA 70 NATIONAL ELECTRICAL CODES 2017 <br />A2 1ST AND 2ND FLOOR PLAN A <br />AUG 18 ZO2 AT - ALUMINUM THRESHOLD OC - ON CENTER 3.0 TRUSS CONNECTOR REVISION a ° <br />A3 STAIR DETAILS <br />A4 FRAMING PLANS A <br />AB • ANCHOR BOLT OGD - OVERHEAD GARAGE DOOR 2020 FBC PLUMBING RESIDENTIAL SECTION 604 9 W Do,,,,9� <br />AVG -AVERAGE 4.0 FLORIDA BUILDING CODE 7TH EDITION (2020) UPDATE A5 EXTERIOR ELEVATIONS &ROOF PLAN LO <br />OPNG - OPENING 1. TANK TYPE WATER CLOSET VOLUME ' <br />A6.1 1ST FLOOR ELECTRICAL PLANCID <br />BFE -BASE FLOOD ELEVATION OPP -OPPOSITE 1.6 GALLONS 5.0 ADDING K, L & M ELEVATIONS <br />m a <br />BM -BEAM OPT - OPTIONAL A6.2 2ND FLOOR ELECTRICAL PLAN <br />BLK -BLOCK OH - OVER HANG SNO STRUCTURAL NOTES, °° A 01 �� <br />2. WATER - FLOW RATE. ° o� Q <br />BLDG -BUILDING <br />OH CABS- OVERHEAD CABS SN1 STRUCTURAL NOTESBRD -BOARD z <br />BRG - BEARING PTD - PAINTED <br />PUBLIC FACILITIES LAV 0.5 G.P.M. <br />PNT PAINT FINISH S3 FOUNDATION DETAILS w <br />PRIVATE FACILITIES LAV 2.2 G.P.M. S4 FRAME WALL DETAILS <br />BTM -BOTTOM PED -PEDESTAL SHOWER HEADS 2.5 G.P.M. S5 STRUCTURAL DETAILS Oo <br />BUC - BUILT UP COLUMN PERF -PERFORATED <br />CAB - CABINET PLT -PLATE 3. ALL PLUMBING WATER LINES S6 WALL SECTION DETAILS <br />SS RETRO FIT DETAILS <br />CD -CONSTRUCTION DOCUMENTS PLYWD -PLYWOOD TO BE CPVC ST STAIR DETAILS w <br />CLG - CEILING PKT -POCKET <br />CLG HT - CEILING HEIGHT LB -POUND VTR LOCATIONS ARE APPROXIMATE AND MAY CHANGE DUE TO S11 PRECAST DETAILS p <br />CEMT - CEMENTITIOUS PSF - POUNDS PER SQUARE FOOT JOBSITE CONDITIONS S12 PRECAST DETAILS Z <br />CL - CENTERLINE PSI - POUNDS PER SQUARE PA 1.0 PRODUCT APPROVAL <br />COL -COLUMN PT - PRESSURE TREATED THE FOLLOWING SHALL COMPLY WITH THE 2020 FBC RESIDENTIAL PA 1.1 PRODUCT APPROVAL <br />CONC - CONCRETE PB - PUSH BUTTON CODE PA 1.2 PRODUCT APPROVAL <br />CMU - CONCRETE MASONRY UNIT REF - REFRIGERATOR PA 1.3 PRODUCT APPROVAL <br />CONST - CONSTRUCT OR CONSTRUCTION RECP -RECEPTACLE 0 PORCHES AND BALCONIES N N n �, F <br />CONT - CONTINUOUS OR CONTINUES REINF - REINFORCING CHAP. 3 SH 1.0 HURRICANE SHUTTERS L i ' M u <br />CTR -CENTER REQD - REQUIRED �, r) - <br />CJ -CONTROL JOINT R/A -RETURN AIR HANDRAILS - CHAP. 3 SH 1.1 HURRICANE SHUTTERS } ) <br />SH 1.4 HURRICANE SHUTTERS M <br />SH 1.2 HURRICANE SHUTTERS D Mco <br />DP - DEEP OR DEPTH SH 1.3 HURRICANE SHUTTERS to V _ <br />i L <br />DTL -DETAIL RS -ROUGH SAWNo <br />M <br />GUARDRAILS - CHAP. 3 2 _O w 2 0 <br />DIA - DIAMETER SC - SOLID CORE SH 1.5 HURRICANE SHUTTERS p U- o a Q <br />DIM - DIMENSION SCP -SCUPPER WP 1.0 WATERPROOFING DETAILS U p °-,' < <br />DISCON - DISCONNECT Q STAIRS - CHAP. 3 'N w N <br />SCRN -SCREEN <br />SIM - SIMILAR E o) DW -DISHWASHER V � <br />DR -DOOR SHLVS -SHELVES CHIMNEY & FIREPLACE p a <br />DBL - DOUBLE S/R - SHELF & ROD CHAP. 10 <br />DWG - DRAWING SH - SINGLE HUNG WINDOW <br />EA -EACH SGD - SLIDING GLASS DOOR EGRESS WINDOWS <br />ELEC - ELECTRICAL SPECS - SPECIFICATIONS CHAP. 3 <br />ELEV -ELEVATOR SQ FT - SQUARE FEET <br />EQ -EQUAL SQ IN - SQUARE INCH 5. ALL OPENINGS SHALL COMPLY WITH 2O20 FBC RESIDENTIAL WIND LOADS AS STATED <br />EQUP - EQUIPMENT STD -STANDARD BELOW. ATTACHMENTS OF WINDOWS, DOORS, SLIDING GLASS DOORS AND O.H. <br />EXP JT - EXPANSION JOINT STL -STEEL GARAGE DOORS ARE TO DELEGATED THE MANUFACTURER OF THESE ITEMS. THE �. <br />EXT - EXTERIOR STRUCT -STRUCTURAL MANUFACTURER OF THESE ITEMS SHALL SUBMIT ATTACHMENTS FOR SITE <br />FIN FLR - FINISHED FLOOR TEMP -TEMPERED INSTALLATION. <br />FIN - FIN THK - THICK OR THICKNESS <br />EW - EACH WAY TB - TOWEL BAR SEE ATTACHED SPECIFICATION SHEETS FOR MANUFACTURERS DESIGN CRITERIA <br />FIG - FIXED GLASS TOM - TOP OF CONCRETE FD -FLOOR DRAIN TOM -TOP OF MASONRY AND INSTALLATION METHODS FOR WINDOWS, DOORS, SLIDING GLASS DOORS, FE - FIRE EXTINGUISHER TOP - TOP OF PLATE OVERHEAD GARAGE DOORS, AND ROOFING. <br />FLR - FLOOR TP - TOILET PAPER HOLDER <br />FLOUR - FLUORESCENT TYP - TYPICAL 6. ALL DOORS INTERIOR & EXTERIOR ARE 6'-8" UNLESS OTHERWISE NOTED ALL <br />FTG - FOOTING UNO - UNLESS NOTED OTHERWISE SHOWER ENCLOSURES TO BE TEMPERED GLASS ui w o <br />FR DR - FRENCH DOOR VAC -VACUUM LU � ~ x J of Q ~ oz � <br />GALV - GALVANIZED VAL -VALANCE 7. ALL WINDOWS WITHIN 24" OF DOORS (INTERIOR & EXTERIOR) AND WITHIN 18" OF FLR Of < U Q X c¢n z o can'i ov oo J <br />TO BE TEMPERED GLASS. (SECTION R308) I. cn o o o o m <br />VFRT-VERFIYINFIELD ~ �wawcnwwwv���¢ D <br />GA -GAUGE QzLLw_z2� �Q <br />GB -GRAB BAR <br />GFI / GFCI - GROUND FAULT CIRCUIT INTERRUPTOR VTR -VENT THROUGH ROOF <br />ILL <br />GLS - GLASS V - VOLT LL_ Q 0 W 2 � Y z < < Q <br />DIMENSIONING: O Z-J'�Q�Wac�-nZWz�`L�oa <br />GWB - GYPSUM WALL BOARD WC - WATER CLOSET ° a o a a <br />GYPBRD - GYPSUM BOARD WH. - WATER HEATER A. DIMENSIONS INDICATED ARE TO: <br />HD - HEAD WL - WIND LOAD A.1. CMU WALL: OUTSIDE FACE OF WALL <br />HVAC - HEATING, VENTILATING, AIR CONDITIONING WP - WEATHERPROOF A.2. INTERIOR FRAMED WALLS: PLAN WEST (OR PLAN NORTH) FROM FACE OF <br />HT - HEIGHT WWM - WELDED WIRE MESH CORE -STUD <br />HB - HOSE BIB W - WIDE OR WIDTH A.2.1. DIMENSIONS ARE NOT FROM ELEMENTS ATTACHED TO CORE STUD - I.E. O <br />HC - HANDICAP WDW - WINDOW FURRING\ N <br />INSUL - INSULATION W/ - WITH A.3. EXTERIOR FRAMED WALLS: TO OUTSIDE FACE OF STRUCTURAL CORE -STUD Z W <br />INT - INTERIOR WD - WOOD A.4. WINDOW OPENINGS: 0 <br />LVL - LAMINATED VENEER LUMBER A.4.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING <br />LT - LAUNDRY TUB U) <br />LGT - LIGHT A.4.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING <br />MAX - MAXIMUM A.5. DOOR OPENINGS: > (D O <br />MATL - MATERIAL A.5.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING F_� co O <br />MFR -MANUFACTURER A.5.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING Q M ~ <br />MECH - MECHANICAL A.5.3. INTERIOR FRAMED WALLS: ADJACENT TO SIDE WALL: 5" RETURN MEASURED a- U) J <br />MTL - METAL FROM THE FINISH FACE OF ADJACENT WALL. TO INTERIOR FACE OF DOOR (n LL ti <br />MC - MEDICINE CABINET FRAME Q W Q <br />MIN -MINIMUM Lo <br />A.5.4. INTERIOR FRAMED WALLS: AWAY FROM SIDE WALLS: DIMENSIONED TO CENTER 01 W M <br />OF DOOR 0- 2 � <br />A.6. SPECIAL AND CODE REQUIRED CLEARANCES -AS INDICATED ON PLANS OR FINISH Q >- Q <br />SURFACE TO FINISH SURFACE Z 0 <br />SYMBOL LEGEND . A.6. 1. EXAMPLE: T-10" CLEAR INSIDE FINISH FOR ADA TRANSFER B. ALIGNMENT OF WALLS AND FINISHES AS SCHE ULED SHSHOWER W ALL E STRAIGHT, TRUE AND W <br />PLUMB. <br />J� <br />= STAIR CALL OUT HEIGHT OF SHEET NUMBER O <br />STEP DOWN C. THE PRIORITY FOR PROJECT DIMENSIONS SHALL BE IN THE FOLLOWING ORDER: (0 <br />1 INT ELEV NUMBER C.1. CODE MINIMUM - MAXIMUM DIMENSIONS AND CLEARANCES � <br />FOOTING CALL OUT - STEP DOWN ARROW SHOWS C.2. LOAD BEARING CONCRETE MASONRY UNIT WALLS <br />= SEE. FOOTING CALLOUT DIRECTION OF VIEW C.3. FRAMED WALLS EXTERIOR <br />SCHEDULE <br />ARROW SHOWS INTERIOR ELEVATION CA. FRAMED WALLS INTERIOR <br />= KEYNOTE CALL OUT DIRECTION OF VIEW MARKER C.5. DOORS AND WINDOWS <br />1 D. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB - <br />A9 ELEV NUMBER ARROW SHOWS UNLESS OTHERWISE NOTED <br />PRE -CAST LINTEL CALL SHEET NUMBER DIRECTION OF CUT E. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE <br />O SCHEDULE -SEE <br />LENTEL ELEVAEXTERIOR TION MARKER 1 OF MATERIAL AT THE DIMENSION POINT - UNLESS OTHERWISE NOTED <br />Al SECTION NUMBER F. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF THE <br />I I <br />1 <-ELEV NUMBER ;SHEET NUMBER STRUCTURAL MATERIAL ABOVE AS SCHEDULED <br />G. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, <br />LG-2 LEDGER CALL OUT -SEE SHEET NUMBER CLEARANCE AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND <br />LEDGER SCHEDULE 4 A15 2 COMPONENTS - DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE <br />�--ARROW SHOWS LOCATION OF CUT DRAWINGS. <br />3 DIRECTION OF VIEW <br />MULTI VIEW INTERIOR SECTION <br />ELEVATION MARKER MARKER C)C) coy N N N <br />o 0 0 0 0 <br />P_ r M M <br />O 1 ` N O <br />W O O N N <br />O O - O O <br />Z <br />0 <br />CID <br />WO O O O O l <br />N M 4 6 <br />JUN 1 1 2022 <br />00 Z1-- <br />Q Z <br />VIRTUAL REVIEW ASSIST O Z w <br />L� <br />LE N NARMVirtual Review Assist, Inc. +I-+ U woo <br />P11'ans Review completed and p ved 0) O 0Z j <br />for compliance with the 2020 FBC 7th 00 oro <br />Edition by Debra Anne Klahr PX2300 � � ,--I Z w�M <br />LENNAR TAMPA DIVSION <br />mLn <br />�� <br />(V zo= <br />4600 W CYPRESS ST, SUITE 200 W Qj:(0 <br />TAMPA FL 33607 NOTICE TO BUILDER &ALL SUBCONTRACTORS • • M 2 0 Zcro <br />IT IS THE INTENT OF DESIGN PROFESSIONAL LISTED IN THE TITLE z 0 0-Z� <br />813.5 74.5 7 00 BLOCK THAT THESE DOCUMENTS ARE ACCURATE, PROVIDING z <br />LICENSED PROFESSIONALS CLEAR INFORMATION. EVERY ATTEMPT Q <br />HAS BEEN MADE TO PREVENT ERRORS: THE BUILDER AND ALL 0 J <br />SUBCONTRACTORS ARE REQUIRED TO REVIEW ALL THE O <br />INFORMATION CONTAINED IN THESE DOCUMENTS, PRIOR TO THE O <br />COMMENCEMENT OF ANY WORK. THE DESIGN PROFESSIONAL ARE MM <br />NOT RESPONSIBLE FOR ANY PLAN ERRORS, OMISSIONS,OR W <br />MISINTERPRETATIONS UNDETECTED AND NOT REPORTED TO THE C S Q <br />DESIGN PROFESSIONAL PRIOR TO CONSTRUCTION. ALL z w <br />CONSTRUCTION MUST BE IN ACCORDANCE TO THE INFORMATION <br />FOUND IN THESE DOCUMENTS. ANY QUESTIONS REGARDING THE <br />INFORMATION FOUND IN THESE PLANS SHOULD BE DIRECTED TO THE o <br />DESIGN PROFESSIONAL LISTED IN THIS TITLE PAGE. NO BACK O LAST PLOT DATE2551 " <br />CHARGES WILL BE CONSIDERED FOR REIMBURSEMENT BY THE > <br />. April 11, 2022 <br />� <br />DESIGN PROFESSIONAL WITHOUT ADVANCED NOTIFICATION AND z O <br />APPROVAL BY THE DESIGN PROFESSIONAL. <br />J COVER SHEET <br />
The URL can be used to link to this page
Your browser does not support the video tag.