6463 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6463 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 3:24:11 PM
Creation date
2/19/2025 11:41:53 AM
Metadata
Fields
Template:
Building Plans
Street #
6463
Location
Beverly HIlls Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
4642
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 3 1/4" TAPCON ( 1 1/4" MIN. <br />EMBEDMENT INTO BLK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45^ DIAGONAL (4) 10d NAILS INTO <br />BRACE(S) 2 x 8 BRACE/ BLKG. ' <br />7/16" OSB <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) _ POLY -CELL IN THIS AREA <br />BACKSIDE TO FIT ARCH (4) 10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />INSTALL WDW. SCREW ANCHOR\\,--2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />INTO ARCH BLKG. PER ARCH FACES W (4) 10d NAILS THRU OSB INTO 2 x 8 <br />INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU —� <br />1-112" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL J <br />SCALE: N.T.S. SS <br />DOOR JAMB (REFER 1x4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />1x4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />1x4 1/2" DRYWALL <br />P.T. <br />TO PRODUCT <br />TO PRODUCT <br />TO PRODUCT <br />APPROVAL FOR CONN. <br />APPROVAL FOR CONN. <br />APPROVAL FOR CONN. <br />1x4 <br />1 X 4 <br />3-1/4" LONG X 3/16" 0 <br />1x4 P.T. <br />FURRING <br />3/16"O X 3" LONG <br />TAPCONS <br />FURRING <br />(2) ROWS 3/16" x 3-1/2" <br />FURRING <br />TAPCON. INTO <br />STAGGERED @ 16", <br />TAPCON 16" O.C. & 4" <br />X8 <br />L111X8 <br />BLOCK@ SPACING „ <br />1 <br />DETAIL <br />O.C. 2-ROWS INTO <br />1x8 P.T. <br />FROM EACH END w/ MIN. <br />2" EDGE DIST. ATTACH <br />PER MANUFACTURE <br />MASONRY THROUGH 1-1 /211 DETAIL <br />1x8 w/ (2) ROWS 8d NALS <br />" <br />3 DETAIL <br />1x4 P.T. & 1x8 P.T. <br />STAGGERED @ 12" O.C, <br />3/16" x 3 -1/2" <br />1x4 P.T. <br />DOOR JAMB (REFER <br />TAPCON @ 16" <br />TO PRODUCT <br />O.C. & 4" FROM <br />DOOR JAMB (REFER <br />APPROVAL FOR CONN. <br />1x4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />EACH END W/ MIN <br />TO PRODUCT <br />TO PRODUCT <br />EDGE DIST. <br />APPROVAL FOR CONN. <br />2x8 P.T. w/ (2) ROWS 3/16'APPROVAL <br />FOR CO�422" <br />(2) ROWS 3/16" x 3-1/2" <br />x 3-1/2" TAPCON @ 16" <br />O.C. & 4" FROM EACHTAPCON <br />1x4 <br />@ 16" O.C. & <br />END w/ MIN. 2" EDGE DIST.FURRING <br />4" FROM EACH END w/ <br />2x8 P.T. <br />ATTACH SECOND PLY w/ <br />P.T. AS REQ'D <br />MIN. 2" EDGE DIST. <br />(2) ROWS 10dx3" <br />2x8 <br />2x DETAIL <br />2 1/4" <br />DETAIL <br />STAGGERED @ 12" 0' <br />3-1/4" DETAIL <br />BUILDOUT @ OVERSIZE DOOR -WINDOW ROUGH OPENINGS CC <br />SCALE: N.T.S. SS <br />PROPER INSTALLATION MAX. $ <br />FILL SOLID <br />BOTH CELLS <br />#5 REB1 <br />(TYP) <br />STD. 90' <br />HOOK (1 <br />-J <br />+5^ <br />IE <br />NOTCH WEB AT <br />FIRST 2 COURSI <br />SECTION UPLIFT CAPACITY = 805 # FOR 1 STRAP <br />A -A <br />1/4" MAX = 1610 # FOR 2 STRAPS <br />n 2'-0" 8" 1 PLY PRE-ENGINEERED TRUSS <br />SOLID BLKG. AT TOP BTWN. 1/4" x 3 1/4" TAPCONS <br />ARCH BLKG. & BUCK sf _ <br />�--LEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />-2 x 8 45 DIAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3) 10d NAILS <br />AT EA. END <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAD. <br />2 <br />x 8 BUCK - CONNECT TO BLOCK SECTION <br />WITH <br />1/4" x 3 1/4" TAPCON (1 1/4" MIN. B-B <br />1/4" MAX EMBEDMENT INTO K.) <br />2'-011 8" <br />BLOCK HEADER <br />SOLID BLKG. AT TOP BTWN. ARCH <br />1 X 4 FURRING <br />BLKG. & BUCK <br />8d NAILS @ 8" O.C. AT BUCK <br />2 x 8 VERT. W/ (2) 10d <br />_ <br />PROVIDE 2 x 8 DIAG. BRACE BT <br />NAILS AT EA. END <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />LEAVE A CUT OUT IN O.S.B. ON T <br />2 x 8 VERT. BRACE(S) <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />BUILT UP PLWD. BUCK - <br />SCRIBE (NOTCH) BACKSIDE <br />7/16" OSB ARCH PANEL <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />INSTALL WDW, SCREW <br />ANCHOR INTO ARCH BLKG. <br />BTWN. OSB ARCH FACES W/ (4) 10d NAILS EQUAL EQUAL <br />THRU OSB INTO 2 x 8 <br />PER INSTALLATION DETAILS <br />B-B <br />ARCH DETAIL K <br />SCALE: N.T.S. SS <br />PROVIDE 2x <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK - (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />4' MAX. RAD. <br />SIMPSON HM9KT w/ (4) 1/4"x1 1/2" SDS <br />SCREWS & (5) 1/4" x 2 1/4" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 w/ (16) 16d <br />' ' SINKERS AND (7) 1/4"x2 1/4" TITEN = 2150 #) <br />BOND BEAM OR CAST IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4'/2' WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL <br />USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />12 <br />JACK TRUSS PROVIDED BY SEE <br />TRUSS COMPANY OR PLA <br />2x6 #2 SYP @ 24" O.C. N <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />(5) 12d NAILS <br />2X6 TO 2X4 <br />NOTE: <br />SHED ROOF ENDS TO BE <br />GABLE ONLY, CORNERS <br />SHALL NOT BE FRAMED AS <br />HIP. <br />DESIGNED ONLY FOR THE <br />INSTALLATION OF SHINGLE <br />AND METAL ROOF FINISH <br />GLASS BLOCK INSTALLATION NOTES <br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />EXPANSION STRIP <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />20 ga. PANEL <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GL'aSS <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />ANCHOR <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />1/4" EXPANSION BOLT (2 <br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />9 ga. PANEL PER ANCHOR) <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />REINFORCING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />(EVERY OTHER <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />COURSE) EXPANSION STRIP <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />SEALANT <br />PRESS PANEL REINFORCING INTO PLACE. <br />°.„ .' 6 MIN. LAP SPLICE W/ <br />COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />REINFORCING PANEL <br />SMOOTH. DO NO FURROW. <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />6" MIN. LAP <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />SPLICE <br />REMAIN FREE OF MORTAR. <br />NOTE: <br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SEALANT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />GLASS BLOCK DETAIL <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH", PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />JACK TRUSS PROVIDED BY <br />TRUSS COMPANY OR 2x4 <br />#2 SYP @ 24" O.C. <br />SIMPSON <br />H2.5A w/ (10) <br />8d NAILS <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (2) #6 X 4'/2' WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2) 1/4" X 3 112" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY L <br />SCALE: 3/4" = 1'-0" SS <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />(1) #5 BARS CONT. <br />TOP WITH MIN. 3" <br />COVER 6'-0" . <br />° D � <br />I� <br />o � III <br />,.e IIII. <br />e _ <br />GRADE , ` D <br />M L <br />z <br />N •D <br />16" MIN, <br />W.W.M. AT PERIMETER <br />WHERE THIS CONDITION <br />OCCURS <br />F.F. <br />(2) #5 REBAR. MIN. 3" <br />COVER EA. WAY <br />SECTION AT DEEP MONO FOUNDATION <br />SCALE: 3/4" = V-0" <br />FILLED CELL PER <br />FOUNDATION PLAN <br />1R <br />YP.) <br />FHE <br />S <br />I IKIAf tf E:07ADI C IAICTAI I TInKI <br />FILLED CELL INSTALLATION I H <br />SCALE: N.T.S. SS <br />SIFF ARCH PLAdN AND <br />=a <br />1 , E14 P4:J IntC_N <br />=`z SEE NCIT- T 6'>V <br />- I 2x SLO6 A` CIA <br />ALU DRIP EDGE <br />E `G .. 1' _T_"" ALAI FA : I.,A <br />R R PL.NU- I ti 3' TRRM Aat <br />' C <br />FASTENED PER <br />IA 2 <br />4 C <br />I --- <br />��.� TE BELOW 1 1 1 ITT VIS VENTED CL' ' SOFFIT <br />C C 4 -AIL � °ID s.. 13;1 44 ».IN I'YA ape °F <br />z _z . &_3 t H I RL1 E rI 0 H4_- rI-.I <br />-1. m II _ _ L E 4 ¢-ERIF"'�`'�F�Pt�.o IDE SOFF" T MATERI,AL SPAN TAI ;AOITiES BASED <br />N TIC_ DEIr f PCESS" �IRES SPEC .IF E E F COMPONENT_ IP W t EI`IT AN 1: I EAE'EI <br />`=TEL) THE DESIGN CRFrERIA ON SHEET E'N. <br />INC' # ..# Ik7 , _ _- <br />FIIRO,FUCTAPFR,.>,?A_j# C;I ANN� s EN _ T4}: <br />IIvvv T NAIL .Fr A A f 1 5� EI IE ELIITEI IT <br />TA LE: I.1 t1_ IN D4=*4r3NII [ <br />A TT Rs� <br />SI_nE4 FASCIA w,+ lb GA -H 4 x :W4 CROWN APLE z': E, 1 Gd 1IrVE <br />STRUCTURAL SOFFIT <br />SPAI <br />�sL� it i" i FOR ALUMINUM SOFFITS WITH SPANS <br />.:'1 1*-A', "-TALI k1ID SPAN IL SIN": PAR <br />TIFF S .FFl F 'N =TAI_LATI(3N C. ITFRIA <br />-REFER TO THE PRODUCT APPROVAL FOR INSTALLATION DETAILS.' <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />TRUSS AS SHOWN FOR O.H. UP TO 2'-6" <br />* DOUBLE 2X4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />k (2) 10d NAILS @ 8" O.C. <br />OV�RygN TO TRUSS TOP CHORD <br />+ <br />+ + �yOTy PLYWOOD SHEATHING <br />+ + BLOCKING AS <br />+ REQUIRED <br />TO SUPPORT <br />TRUSS + SOFFIT <br />2X4 SYP--------------- <br />EACH TRUSS <br />CONNECTOR <br />SEE LINTEL <br />SCHED. <br />PRECAST LINTEL Is <br />SEE ELEVATION <br />2X2 #2 P.T. MIN. FOR OVER HANG <br />W/J-CHANNEL SECURED (MAX. 4'-0") <br />@24" O.C. FASTENED TO <br />CMU W/ 3" LONG T-NAILS @ <br />24" O.C. <br />SECTION @ ROOF EXTENSION M <br />SCALE: 3/4" = T-O" SS <br />SIMPSON HTT4 w/ (18) 10d x 1 <br />1/2" NAILS TO STUDS & (1) - <br />5/8" DIA. ALL THREAD ROD <br />EPDXIED w/ SIMPSON "SET" <br />EPDXY MIN. 6" EMBEDMENT 8 <br />3" MIN. EDGE DISTANCE <br />RETROFIT FOR MI. <br />MSTAM STRAP <br />54'Al F R/d <br />CFF CWF:F:T Ill ANIIl <br />z <br />O <br />Q <br />LL <br />O <br />W <br />H <br />U <br />rn <br />2"x BOT. PLATE W/ (2) 1 Od @ 6" O.C. <br />3/4" PLYWOOD DECKING GLUED ATTACHED WALL SHEATHING TO <br />AND NAILED W/ 8d COMMON @ 2X BOTTOM PLATE W/ 8d @ 4" <br />6" O.C. EDGES AND 12" O.C. FIELD O.C., 2 ROWS STAGGERED <br />2x BAND JOIST W/ FACE NAIL 10d <br />@ TOP & BTTM CHORD, AND (8) <br />FACE NAILS 1 Od @ TRUSS VERT. <br />WEB <br />METAL SEAT PLATE <br />NOTE: <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />SIMPSON HGAM1OKTA @ 12" O.C. <br />w/ (4) 1/41 1/2" SIDS SCREWS <br />INTO BAND JOIST & (4) 1/4"x2 3/4" <br />TITEN INTO K.O. BLOCK <br />RETROFIT FOR MISSING EMBEDDED STRAP <br />SCALE: N.T.S. <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO <br />FILL 1st COURSES <br />SOLID W/GROUT <br />d: <br />4 <br />FOR OVERHANGS BETWEEN OVER 1 1/2" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. <br />�a. <br />OVERHAN <br />a' <br />RETROFIT WALL OVERHANG DETAIL (NTS <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D. <br />1'-011 5'-0" <br />NISH <br />° e p ° #5 BAR XX <br />D. u 1.0" a p a <br />D ° . CENTERED W/ <br />o ,� s H IN TOP CD <br />e , 13 KNOCKOUT/ N <br />CHAIR BLOCK <br />MONO FOOTING I- I I p <br />SIZE AND REINF. PER <br />AND SECTION DETAILS -I <br />� ° <br />CLEAN FILL e ° <br />DIRT z <br />e. ° STANDARD o <br />0 9(. HOOK N <br />#5 BAR IN <br />FILLED CELL <br />- V A 9 ®.A S, ®1. 9 1% <br />STEMWALL FOOTING SIZE AND <br />MONO TO STEMWALL FOOTING REINF. AND STEMWALL <br />SECTIONN DDETAETAILS <br />SCALE: 3/4" = V-0" <br />OTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJEC- <br />:ONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />EPDXY CAP TO PREVENT LEAKAGE <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2") <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />FILL CELL FULL HEIGHT W/ <br />NON SHRINK GROUT. <br />#5x6' EMBEDDED INTO <br />EXISTING FOOTING <br />DRILL 3/4"x5" MIN. HOLE <br />SET BAR IN EPDXY <br />In% J4C.1C1 Ik[ f+llA ll� <br />4" SAW CUT <br />EXISTING FOOTING A SECTION <br />1 SCALE: N.T.S. <br />RETROFIT FILLED CELL DETAIL - <br />\/F <br />JUN 1 1 2022 <br />VIRTUAL REVIEW ASSIST <br />Virtuai Review Assist, Inc. <br />plans Review completed and a roved <br />for compliance with the 2020 FBC 7th <br />Edition by Debra Anne Klahr PX2300 <br />m4"Cq <br />O <br />CA <br />1 <br />AI <br />LO <br />CD <br />, <br />° <br />yy <br />w <br />0 <br />w <br />0 <br />z <br />Q <br />n` E <br />-0 <br />W L `'' o <br />C'O v Gi <br />A� L o <br />W O2 o <br />o N Q <br />.N w Q� <br />C <br />0 O c(V <br />W L � � ri .� <br />W <br />❑ LLI uj W 0 I- <br />Ld �Q 0r of zzW <br />z <br />Q (� <br />Q � X � � p� � O � LL O 00 <br />� J 0 <br />Q F- <br />Q 0 z,1L�_z��o�aQ <br />(3cn�9OLLIzOWOomzz <br />O-�zYOZZLLO <br />cn00 <br />Z <br />QFWO�F¢� �W6aO <br />a <br />LL.O� <br />Q O oQQiX <br />LL LL. <br />O <br />0 <br />N <br />Z W <br />0i-Z <br />> (n O <br />0 1- co O <br />QU)CM� <br />J <br />Q W QLo <br />~ C'7 <br />00 <br />Q Q <br />Z 0 1— <br />W <br />W <br />_j <br />O <br />J <br />mot' <br />I <br />1 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />C)CDo <br />0 <br />0 <br />0 <br />0 <br />0 <br />N <br />N <br />N <br />N <br />n <br />r <br />M <br />Q <br />00 <br />O <br />0) <br />C) <br />O <br />T <br />N <br />O <br />1 <br />1 <br />1 <br />' <br />z <br />O <br />W <br />a <br />o <br />0 <br />0 <br />1 <br />I <br />I <br />'`^ <br />r/ <br />\ <br />N <br />M <br />4 <br />1 <br />1 <br />1 <br />Co07 <br />^ <br />zZ <br />vJ <br />Qz <br />O <br />zw <br />-E—� <br />0 <br />W <br />V <br />0 O O <br />(wj0cn <br />� /'� <br />0 <br />�z> <br />Ot-- <br />V J <br />Z <br />t-- <br />aWa <br />UJI W Q <br />m=w <br />r=nn <br />V <br />I- <br />N <br />O <br />zo= <br />W <br />. . C'7 <br />Q <br />O <br />QWaf <br />Z <br />UJz <br />EL <br />z <br />SQ <br />Z <br />X� <br />U0 <br />D <br />IZ <br />m <br />z <br />z <br />z <br />z <br />w <br />W <br />J <br />o <br />ti <br />LAST PLOT DATE <br />z 0 <br />STRUCTURAL <br />" —J <br />DETAILS - RETRO FIT <br />