My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6463 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6463 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 3:24:11 PM
Creation date
2/19/2025 11:41:53 AM
Metadata
Fields
Template:
Building Plans
Street #
6463
Location
Beverly HIlls Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
4642
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECOND FLOOR ELECTRICAL PLAN (ALL ELEVATIONS) <br />1 /4„ = 1'-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.1. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />JUNii'�'' <br />Y3W ASSIST <br />virtual Review Assist, Inc. I approved <br />Plans Review completed and pp <br />for cojrtpliance with the 2020 FBC 7th <br />Edition by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />co <br />SWITCH- <br />4 1/2" <br />DOORJAMB DUPLEX 19 <br />OUTLET c0 <br />TRIM o <br />0 <br />BASE --]— <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />k <br />SMOKE DETECTOR <br />1'-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />- SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-o PUSH BUTTON FOR GARAGE DOOR OPENER <br />-fl DIMMER SWITCH AT 36" <br />-0 PUSH-BUTTON DOORBELL <br />-,- CLG MNT LT FIXTURE <br />B CLG MNT PREWIRE - FIXTURE BY OWNER <br />-`}- SURFACE MNT FIXTURE <br />-} WALL MNT FIXTURE <br />NOTE: <br />TUB/SHOWERND OPALEX - ALTERNATE CANS MAY BE <br />USEDIF <br />50W PAR30 NFL 6" WHITE BAFFLE APPROVED BY <br />50W MR16 4" LOW VOLTAGE OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />16o� 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-`t'- CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />ID SMOKE DETECTOR <br />-U-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />9;:24:;g 24" VANITY LIGHTING <br />36-_;;� 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />ELEC PANEL <br />® VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />E3 A/C REGISTER <br />THERMOSTAT <br />I3 SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />�1 r E <br />ce)� 4) <br />Vi V Q d <br />M <br />E �, w t <br />2 O <br />o <br />o <br />rn�rn u- <br />V/ O <br />t 0611, "0 <br />Q <br />.N U w Q!;� <br />7W L C) <br />V ^ a -40) <br />W <br />W <br />oLLiw <br />< W _j Q ¢<z� <br />Q z <br />11 -D- 0 � W iL00�J� <br />0Y <br />Q Q <br />� <br />U <br />~ <br />JOOQZLL -- <br />�waWFnz <br />�0HQQ <br />O <br />U) 0Z <br />Q~<OUJFa--�ZLUwp�UOQ <br />��z <br />CL <br />LL. <br />00T o <br />a <br />oQeZ <br />,L0 <br />ma w <br />O <br />O <br />CV <br />Z <br />O IW— <br />i (n O <br />0 F— cM O <br />Q w M � <br />IL <br />Q W Q U? <br />F_ M <br />Cb <br />Q <br />>- Q <br />Z V I— <br />W <br />W <br />JC:) <br />Mj <br />I <br />I <br />I <br />C) <br />C) <br />o0000 <br />CD <br />O <br />N <br />N <br />N <br />N <br />N <br />N <br />ICY) <br />M <br />CO <br />W <br />O <br />C) <br />O <br />O <br />c- <br />N <br />O <br />N <br />O <br />z <br />O <br />WO <br />o <br />N <br />O <br />M <br />O <br />o <br />I <br />I <br />' <br />00 <br />Cr <br />U <br />zZ <br />v^ <br />J <br />Q w <br />C)z <br />-+—' <br />0 <br />W <br />U <br />woo <br />v(.)Fn <br />Lo <br />0 <br />Ozj <br />0�o <br />Z <br />a~< <br />�--I <br />w Q <br />Lr) <br />= <br />0 <br />m=w <br />2 <br />In <br />F- <br />N <br />0 <br />zo= <br />QED <br />M2 <br />0 <br />zwo <br />Q <br />Z <br />U <br />lz <br />�ZLL <br />az <br />Z <br />F- <br />p <br />_a <br />coF. <br />z <br />z <br />z <br />z <br />W <br />0 <br />LAST PLOT DATE <br />C14 <br />. <br />April 11, 2022 <br />Z <br />J <br />2ND FLOOR <br />ELECTRICAL PLAN <br />