Laserfiche WebLink
ul <br />U') <br />!�2 <br />2 <br />00 <br />U0 <br />THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METALLATH <br />... <br />....... * ",­ , 1 <br />T.. ... IT <br />........... ..... .... .... <br />cn.—. . <br />.............. ............ i <br />.... ..... ..... ......... .... <br />CROWN) <br />16GAxl-1\2" LONG (34-1 <br />WALL SHEATHING <br />16GAxl-1/2" LONG (3/4"-l" <br />MAX ....... ... ..... . ..... <br />STAPLES @ 6" O.C. VERT BETWEEN IT .. ..... .. ............... <br />V <br />CROWN) STAPLES @ 6" <br />—)-OFFSET <br />STUDS (NOTED THUS: O.C. VERT INTO STUDS <br />STAPLES BETWEEN STUDS AS SHOWN <br />(NOTED THUS:—) <br />v <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />1 01-0to <br />TANK -LESS W/H <br />H C G <br />000 <br />51-011 <br />STUB -OUT FOR 11-011 —9 <br />a <br />_J Zr) <br />GAS METER 0 0 <br />-1 0 <br />C14 <br />MEASUREMENTS ARE FROM FINISHED FLOOR <br />OFF -CENTER <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12' <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4- @ 16" O.C. <br />71-5" <br />(2) 16d TOENAILS <br />2' X 6' @ 16- O.C. <br />10'-8" <br />(2) 16d TOENAILS <br />2" X 8- @ 16" O.C. <br />131-91' <br />(3) 16d TOENAILS <br />2- X 10" @ 16' O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2- X 12" @ 16- O.C. <br />191-311 <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2' X 4' @ 24" O.C. <br />6--l' <br />(2) 16d TOENAILS <br />2- X 6" @ 24" O.C. <br />V-61- <br />(2) 16d TOENAILS <br />2' X 8' @ 24- O.C. <br />11._011 <br />(2) 16d TOENAILS <br />2- X 10" @ 24- O.C. <br />13'-0" <br />(3) 16d TOENAILS <br />2- X 12" @ 24- O.C. <br />15-4- <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCIOJoist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2x- <br />1- 1 /8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1- 1 /8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1- 1 /8" or two 1/211 <br />602.0 <br />wood panels <br />2 X + 5/8" or 3/4" wood panel <br />902.0 <br />2 x — lumber <br />Double 2 x — lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />FILL CELL—\ STD. 900 HOOK BOND BEAM <br />W <br />CONT. #5 <br />CONT. #5 STD. 90 BAR <br />BAR HOOK <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />INTERIOR/EXT WALL SEE <br />SIMPSC <br />w/ (22) - <br />NAILS I <br />5/81 <br />#5 CONT. THRU <br />BOLT <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8" min 2" min. <br />2" ' )Small gap <br />" <br />max. <br />4 <br />max. <br />Clinch nails <br />when <br />possible <br />1 Support back of web during nailing to prevent damage to <br />web -flange connection. <br />Tight fit --_7 <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />2x4/PIywood/OSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 1 Od nails 4" max. <br />2x CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or <br />Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Ys" GAP @ TOP sides by 6". Hangers with sides not containing <br />top flange of joist. WEB STIFFENER <br />Birdsmouth cuts. N.T.S. <br />DOUBLE JOIST CONNECTION <br />Under 2nd floor column w/ loads <br />N.T.S. hi <br />her than 15001b. <br />BLOCKING PANEL, INTERIOR <br />SQUASH BLOCKS AT INTERIOR Boise Joist Blocking Vertical load transfer =1 900 pif max. along bearing wall <br />BEARING Use 3" (1 Od) nails at 6. O.C. Required on interior walls : - for vertical load transfer W__� Plumbing <br />Vertical load transfer =1900 plf max along load bearing wall. Load bearing walls when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />Load bearing wall must stack beam below Load bearing wall must stack over <br />over squash=20 blocks and <br />*Non -stacking walls <br />wall or beam below.* blocking and wall or beam below.* <br />require additional Joist <br />consideration. Check <br />_f When joists meet over wall, provide <br />local building T1/16" I -Joist can be offset <br />code for appropriate 13/4" minimum bearing for each. up to 3" to avoid <br />details in One 10d box <br />vertical plumbing <br />areas=20 of high or--20 sinker <br />lateral load. nail each side 3"max <br />at bearing. <br />7elt] <br />JOISTS OFFSET <br />N.T.S. <br />Provide adequate bearing <br />for each lapped joist. Use 1 Gdx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />Squash block Od nails require additional consideration. <br />SECTION" INT. BRG. WALL <br />(2x4 minimum) (0 <br />N.T.S. <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED MINIMUM SPACING 2x GREATEST <br />DIMENSION OF LARGEST HOLE <br />D <br />IN BEARING ZONES <br />(se, <br />(KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch Id <br />I _Jr__ <br />or drill flanges I it <br />777,7,5 <br />-. <br />7- -- -. 7 - I <br />- <br />.. - �,� <br />�611 <br />61, A %2" ROUND HOLE MAY 6" 0 NOT CUT HOLES <br />t5t: Ilu I AN TWHERE IN CANTILEVER LARGER THAN 1Y2' <br />THE WEB. PROVIDE AT ------A-ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2' <br />8 <br />T_a, <br />T-T' <br />T-2' <br />lt-Z' <br />11�4' <br />11�-3' <br />11�-7" <br />11�111" <br />2-4* <br />7-9' <br />3-2' <br />3-r' <br />Any 16' jdat 12 <br />l-U* <br />V-11" <br />I'-Z' <br />V-Z' <br />T-9' <br />2-4' <br />2-11 11 <br />3-71 <br />W-21 <br />4-91 <br />6-41 <br />sow 16 <br />1'4r <br />11�4' <br />11'-Z' <br />V-7' <br />V-7" <br />Z-6' <br />3-2' <br />3-10" <br />4-9' <br />6-7' <br />6-4' <br />T-2' <br />20 <br />T47" <br />1A" <br />T-2' <br />V-Z' <br />4-19' <br />6-11" <br />6-11'* 7'-11" <br />9-11" <br />24 <br />T-W <br />I �-I" <br />T-Z' 1 <br />V-3" <br />2�-6' <br />3-7-, <br />4-9' <br />6-10", <br />-P-2' <br />9-4' <br />1 9-6' <br />10'-W. <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CU17ING CHART <br />N.T.S. <br />Web Stiffener Fastener Sc <br />Joist — B aring Location <br />Series Depth I End Intermediate <br />BCI 5000s <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />---S--8a-- <br />BCI 6000se-fl--7/8' <br />BCl 6500s(& <br />9-1/2" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />1,V' <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI 60s8 <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-9d <br />5-8 ad7:1 <br />16" <br />2 -8d <br />13C, gose <br />11-7/8" <br />3-16d <br />3-16 <br />14 <br />5-16d <br />5-16 <br />16- <br />6-16d <br />6-16d <br />Joist hanger <br />SIMPSC <br />w/ (22) <br />NAILS I <br />RTRUSS <br />OP PLATE <br />LC <br />TYPICAL SIMPSON MGT TO <br />BUILT—UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />VIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) <br />Nail with 10- 10d nails. <br />nstall tight to top flange. <br />SLEEVE THRU STEM <br />SEE PLAN FOR--,! <br />. , . <br />. <br />FOUNDATION INFO 4' <br />— <br />STEM FOUNDATION <br />Filler block. <br />Nail with <br />10-1 Od nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />_J <br />1/4"-2" gap — <br />"Top Mount" Backer Block "Face Mount" <br />Backer block shall be fight Backer block shall be fight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />/vv <br />1,6 X Joist <br />lo <br />depth <br />D oo <br />'o <br />lo <br />lo <br />ol <br />I -JOISTS BUCKETS <br />N,T.S. <br />GRADF <br />REINF. SEE PLAN <br />pit, t.,nmoc,4 rvt, <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A (WHEN <br />1 REQUIRED) <br />w/ (18) 1 Od x 11/2" <br />NAILS <br />UPLIFT = 1015#1 <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />9'% 1 r% r- 1 1 r- r'% -I- 1 0% A I -9r' I I F'% I I r- 1 r% <br />PVC OR SCH40 SLEEVE <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE PLUMBING LINE <br />PENETRATION: <br />1. .. . 4 . . .. . ...,o - , L <br />A .4 <br />\A <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />Aq. A <br />A-1 <br />4 <br />q <br />/4 <br />SEE FND. PLN. <br />ol SIZE & REINF. <br />LU <br />V�4 <br />C <br />gOct <br />F.7. <br />Z,Z -95 E <br />.:r <br />cc <br />3r <br />cc <br />W <br />�y <br />r—%XA I A /466 <br />.�11 <br />0 <br />b <br />r. &; <br /><.- -, * - T <br />F <br />....... <br />9(" <br />JF E S S <br />"I"Imill 1 till <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />a <br />E <br />8 <br />Cb 8 <br />r_ 9 r� <br />0 - G -? I § q <br />14 C'n t- r- <br />M U u_ Lu <br />I G Q. <br />LL <br />0) <br />:3 MCNG <br />z 0 <br />L <br />N <br />z 0 Cn <br />W 01:1 <br />c-, <br />< <br />U) <br />4-J <br />(a LU <br />in <br />U <br />0 <br />—$—. <br />YZ(a <br />E <br />2 8 <br />2 . <br />U <br />< eq C. <br />CD <br />Cl) <br />E <br />E 8 <br />'d <br />C:) E <br />.8 <br />E 15 <br />I <br />9 <br />80 0 <br />E z <br />04 <br />q <br />2 <br />A! <br />CO C: <br />8 <br />0 2 <br />.1 , <br />�z <br />218 <br />I z <br />0 <br />8 <br />0 <br />S� <br />z <br />z <br />=D <br />X0 <br />C:) <br />8 <br />La <br />LO <br />LO <br />LO <br />CID <br />co <br />Cr P <br />0 <br />0 <br />CN <br />M <br />in <br />L0 <br />0 <br />0) <br />0 <br />LO <br />C14 <br />-0 N <br />0) <br />lr�_ <br />LO <br />.0 C) <br />LO <br />C%4 <br />0) <br />E <br />2:1 (0 <br />.7 <br />E LO <br />0 <br />z <br />Ca <br />z <br />E T— <br />E 'T <br />- <br />2 <br />(L <br />0 0 <br />-J < 0 <br />_J <br />JOB <br />NO 22-06468 <br />SCALE AS NOTED <br />SHEET NO. <br />SN 1 <br />