��'�1 I '! lIR II IR mil' 7f� �� �I�h'���IR+nll! �1�*nRl�lnl��llla _ �nlw (E��1■■■� <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES. - <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centedine above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, Wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed Within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FfF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />;Oo <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />i-D <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />Ja <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />150AI200A INDOOR <br />PANEL CENTER <br />7 <br />200 amp <br />150 amp <br />UNDERGROUND las <br />SERVICE BY POWER CO.---_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />I to fights & outlets <br />? to appliances and GFI <br />)toWH <br />to Range <br />to HVAC <br />200=4/0 in 2" Conduit <br />4 Bare Cu Ground <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />/ I <br />i <br />DEDICATED RECEPTACLE TANKLESS GAS 2" �v 2ntl F� <br />FOR MICROWAVE RANGE VERIFY METER LOCATION WH WP GAS STUB H.B. R <br />HOOD PER SPECS WITH BUILDER GFI OUT ,lil 21r Y I R 3fi <br />GFI V <br />0 PIP <br />GFI FI VERIFY LOCATION IRRIGATION-- �—--- — <br />I — OPT. - ELECTRICAL PANEL GFI @ 44" A.F.F. <br />t .. REF. <br />I I <br />1 I I I I� i 3fi <br />I <br />KITCHEN <br />� � i� <br />-4 2° rvC <br />GFM o r- __-_-------� � � i i i 44 <br />J — — GFI- Li _ - `---- GAR. I I PLUMBING RISER- <br />XGFI @ 44" DOOR TQ <br />A.F.F. GFI I I I SCALE: NTS NOTE: PLUMBING RISES SCHEMATIC TO MAIN <br />WP=G= BE VERIFIED WITH PLUMBER <br />GFI o 2 CAR GARAGE <br />I i I <br />, <br />DINING ROOM <br />PAT I O <br />I I I <br />ENTRY <br />/PENDANT AS I I I <br />/ PER SPECS CH L------------ <br />// M GFI @44" <br />cn .i M A.F.F. <br />qP <br />FOYER <br />I <br />� I <br />� I <br />— I <br />_ I <br />• IDB <br />VIM I <br />1Z— <br />-1----- <br />/ M f GFI <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRED \ <br />FLEX <br />FAMILY ROOM / <br />GFI <br />ROUGH -IN FOR , <br />DISC. / _ _ OPT. CLG. FAN/ <br />— , LIGHT PRE -WIRE I <br />I I TO LIGHT I <br />I I i 1 14 AND I <br />AC PAD EP)AD I I I I I I SWITCH I <br />I I I I I ABOVE 1 <br />I <br />I <br />H.B. <br />MAIN FLOOR ELECTRICAL PLAN - ELEV-Al <br />SCALE: Y4"=1'-0" <br />N <br />ra <br />N <br />r� <br />C <br />O <br />W <br />C td U CO) <br />N <br />fn (6 O L <br />so <br />a r.s o <br />d - _ a <br />m <br />V <br />>_ E <br />m <br />o <br />0 <br />0 <br />To the best of the Enghears knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Cade - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structured engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />0 <br />I- Jig <br />E <br />0 c) 8 <br />V <br />04 <br />9 t o� N a D <br />N N 0 <br />i k LL <br />� J , <br />.6s W <br />LL LL <br />,w <br />ZV <br />0 0 <br />� lL 0.. <br />-v- a X <br />0 <br />a <br />c <br />Z ILW <br />No <br />N Z -:4Z <br />N <br />OU <br />W <br />to <br />o❑ <br />z � <br />Z <br />^V)' <br />z <br />W <br />U o <br />N <br />W <br />—� <br />O <br />W g <br />V1 <br />�m <br />rz ,-, <br />W <br />E <br />t 8 <br />= <br />U <br />c I <br />¢�w <br />0 <br />W <br />M= <br />J <br />y g <br />g <br />iZ <br />� o <br />C <br />Z• <br />E U <br />d_ <br />gp <br />XO� <br />u0 <br />�U <br />Z <br />o <br />N � <br />a� <br />ao <br />�� <br />wW <br />ao <br />r0 <br />COC <br />10 <br />Z' <br />Z <br />z <br />y <br />N <br />pw <br />O <br />O <br />V <br />W <br />a <br />w <br />�w <br />c� <br />E <br />00 <br />N <br />a Z <br />= <br />yl= <br />003 <br />a <br />O <br />LL <br />LO <br />t71 <br />�\ <br />0 <br />Fes— <br />LO <br />j MO <br />M <br />m <br />m <br />LO <br />O <br />LO <br />N <br />Q <br />r <br />r <br />00 <br />LO <br />tp <br />o <br />Z <br />Z <br />E T <br />N <br />d <br />c <br />a <br />0 _j <br />¢ o <br />JOB <br />NO: <br />22-06468 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.0 <br />