My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6828-6856 Ripple Pond Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6828-6856 Ripple Pond Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:30:22 AM
Creation date
2/19/2025 11:43:05 AM
Metadata
Fields
Template:
Building Plans
Street #
6828-6856
Location
Ripple Pond Lp
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150Af200A INDOOR <br />PANEL CENTER <br />NEMA1 <br />150 AMP/ <br />200 AMP <br />1 to lights & outlets <br />2 to appliances and GFI <br />to WH <br />to Range <br />to HVAC <br />MO l <br />150=2l0 <br />200=4/0 in 2" Conduit <br />200 amp " <br />150 amp <br />UNDERGROUND <br />Disc nnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . <br />Typical 150-200 Amp Electrical Riser Diagram REV.03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16' AFF (general). <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smokelcarbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11.In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />i <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />"WWI, <br />EXHAUST FAN/LIGHT COMBINATION <br />© <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />Ps <br />PUSH BUTTON SWITCH (OPTIONAL) <br />[]DB <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />T� <br />TELEVISION (OPTIONAL) <br />Tq 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W! ROUGH -IN FOR <br />Ci T J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />SMOKE DETECTORS <br />SMOKE DETECTORS SHALL BE IN ALL SLEEPING <br />AREAS, SHALL BE INTERCONNECTED, SHALL BE WITHIN <br />1' TO 3' OF PEAK, AND SHALL BE 3' FROM THE <br />SUPPLY OR AIR STREAM, AND EQUIPPED WITH <br />BATTERY BACK—UP. ALL SMOKE DETECTORS TO BE <br />ARC —FAULT PROTECTED. <br />FAIR HOUSING ACT REQUIREMENTS: <br />OPERABLE PARTS OF THE CONTROLS FOR LIGHT SWITCHES, ELECTRICAL <br />OUTLETS, THERMOSTATS AND OTHER ENVIROMENTAL CONTROLS MUST BE <br />LOCATED NO HIGHER THAN 48", AND NO LOWER THAN 15", ABOVE THE FLOOR. <br />IF THE REACH IS OVER AN OBSTRUCTION (FOR EXAMPLE, AN OVERHANGING <br />SHELF) BETWEEN 20 AND 25 INCHES IN DEPTH, THE MAXIMUM HEIGHT IS <br />REDUCED TO 44" FOR FORWARD APPROACH; OR 46" FOR SIDE APPROACH <br />PROVIDED THE OBSTRUCTION (FOR EAXMPLE, A KITCHEN BASE CABINET) IS <br />NOT MORE THAN 24 " IN DEPTH. OBSTRUCTIONS SHOULD NOT EXTEND MORE <br />THAN 25" FROM THE WALL BENEATH A CONTROL. <br />COMP. <br />DISC. <br />WP <br />GFI <br />Q <br />4 <br />3 NK <br />E� SIFT <br />KIf of o �E <br />W/ A <br />I <br />�ONsO <br />3° <br />0 4,1 <br />,i <br />4 4° <br />M <br />AIN <br />PLUMBING RISER_ <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />VERIFY METER LOCATION WITH UNIT 1397 - ELECTRICAL PLAN <br />BUILDER <br />SCALE: 1/4"=1'-0" <br />E�Y <br />®: <br />ti. S n. o <br />� co <br />m �Lci <br />•:'C7 C-4 <br />... � <br />D C'V <br />ca Q <br />3 3 cc <br />.... C; <br />_C- <br />CU �. <br />tV <br />N <br />0 <br />[V <br />d' <br />ti <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural <br />engineering portions <br />of the drawing pages bearing <br />Engineer's <br />signature and seal, <br />N <br />aMAM <br />�m <br />v <br />,C) o <br />ND <br />LO aP to r <br />(n r V in ft <br />1 <br />Q4 <br />N O U <br />aj M <br />C LL <br />--r <br />J 11 Lt' pW„ <br />I� <br />Z <br />03 <br />W d <br />(U C o <br />to <br />�' <br />tii o <br />:3 (6 N CD Y <br />W <br />_ <br />CP7 °' w <br />05 m <br />Q J <br />Z <br />Uf) (M Z <br />U U <br />W <br />El� <br />Z N O <br />pip o <br />Z �p <br />QNQ <br />O Q <br />a <br />J — <br />N <br />ch <br />CAzD <br />0 0 <br />� <br />U <br />0 <br />V) <br />LU a <br />w <br />case <br />v1 <br />fQ <br />r— <br />w J <br />E <br />ml <br />C) a <br />c to <br />uD 0 <br />C:, <br />w <br />M <br />¢ <br />Z <br />U- <br />cd E <br />LE <br />zo <br />�O <br />aR <br />Q 0 <br />E u <br />�F <br /><= <br />z® <br />W� <br />CU <br />-- <br />X U <br />0 OO <br />o- <br />0 <br />Zo <br />N � <br />i <br />a <br />¢ <br />ao <br />ww <br />¢� <br />w� <br />z <br />mo <br />ZYzZ <br />YZ <br />U) <br />F w <br />O5 <br />Z Z <br />go <br />d <br />a <br />W <br />U <br />w <br />ao <br />�LL <br />F� <br />CD <br />o <br />fw <br />�F <br />=3 <br />69CD ~ <br />� <br />�o <br />oX <br />=-R <br />Vl (V <br />7 LO <br />co <br />o> <br />m <br />0 <br />Q <br />0 <br />00 <br />T <br />(1)m <br />O <br />Q <br />O <br />O N <br />LO <br />.Q <br />a. N <br />C) <br />Co <br />-0 (� <br />(3) N <br />rn <br />Q T— <br />a d' <br />LO <br />c.6 <br />4 <br />,-- <br />o <br />ca <br />CV <br />Z <br />z <br />E <br />E <br />Iu <br />a w? <br />M <br />0- <br />U <br />Q pre <br />JOB <br />NO: 22-08393-08388 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.