Laserfiche WebLink
PLUMBING DEMOLITION PLAN LEVEL TWO <br />Ys" =1'-0" <br />PLUMBING LEGEND <br />o, <br />Ilk <br />DESCRIPTION <br />SANITARY SEWER <br />VENT PIPING <br />COLD WATER <br />HOT WATER <br />EXISTING TO BE REMOVED <br />LIMIT OF REMOVAL <br />NEW TO EXISTING <br />PLUMBING NEW WORK PLAN LEVEL TWO <br />y8" = 1 011 <br />GENERAL NOTES <br />ABBREVIATIONS 1. THE FOLLOWING NOTES ARE GENERAL IN NATURE AND PERTAIN TO THE <br />ENTIRE PROJECT. WHERE THERE ARE EXCEPTIONS, ADDITIONS, OR <br />SAN REVISIONS TO THESE NOTES SUCH EXCEPTIONS, ADDITIONS OR REVISIONS <br />ARE SO NOTED ON THE PARTICULAR DRAWING THEY OCCUR. <br />V 2. PIPING IS SHOWN IN SCHEMATIC FORM. ALL WORK SHALL BE <br />COORDINATED WITH ALL TRADES INVOLVED. <br />CW 3. REFER TO ARCHITECTURAL PLANS FOR LOCATION OF ALL EQUIPMENT. <br />HW 4. ACCESS PANELS SHALL BE PROVIDED, WHERE REQUIRED, TO SERVICE <br />VALVES AND OTHER MECHANICAL EQUIPMENT. <br />5. ALL VALVES IN CORRIDORS SHALL BE LOCATED V- 0" AWAY FROM WALLS <br />CLEAR OF SOFFITS UNLESS NOTED OTHERWISE. <br />6. STORM AND SANITARY PIPING 3" AND LARGER SHALL BE SLOPED AT 1/8" <br />PER FOOT UNLESS NOTED OTHERWISE. <br />7. VERIFY ALL EQUIPMENT CONNECTIONS WITH MANUFACTURERS CERTIFIED <br />DRAWINGS. FIELD VERIFY AND COORDINATE ALL DIMENSIONS PRIOR TO <br />FABRICATION. <br />8. UNLESS NOTED OR OBVIOUS OTHERWISE, PIPE RUNS SHOWN OCCUR IN THE <br />CEILING SPACE OF THE LEVEL INDICATED ON PLANS, <br />ON TO EXISTING <br />& WATER LINES <br />DEMOLITION NOTES <br />1. WHERE EXISTING CONDITIONS ARE SHOWN, THEY HAVE BEEN DERIVED FROM <br />AVAILABLE DRAWINGS AND REPRESENT THE ENGINEER'S BEST ESTIMATE OF <br />ACTUAL CONDITIONS BUT HAVE NOT IN ALL CASES BEEN VERIFIED BY FIELD <br />INVESTIGATION. <br />2. THE CONTRACTOR SHALL NOT ASSUME THAT EXISTING CONDITIONS SHOWN <br />ON THE DRAWINGS ARE COMPLETE AND ACCURATE REPRESENTATIONS OF <br />THE EXISTING PLUMBING SYSTEMS. THE CONTRACTOR SHALL VISIT THE JOB <br />SITE AND BECOME FAMILIAR WITH THE SITE CONDITIONS BEFORE SUBMITTING <br />A BID. ANY ADDITIONAL WORK CAUSED DUE TO LACK OF KNOWLEDGE OF EXISTING <br />SYSTEMS SHALL BE DONE AT NO ADDITIONAL EXPENSE TO THE OWNER. IF <br />AGREEABLE TO THE OWNER, THE CONTRACTOR CAN ESTABLISH LINE ITEM COSTS <br />FOR POSSIBLE DEMOLITION ITEMS THAT ARE UNABLE TO BE IDENTIFIED WITH <br />REASONABLE INVESTIGATION. <br />3. ALL EXISTING PLUMBING FIXTURES REMOVED ARE TO BE RETURNED TO THE OWNER. <br />4. ALL HANGERS, SUPPORTS AND ASSOCIATED FITTINGS INDICATED TO BE DEMOLISHED <br />ABOVE GRADE ARE TO BE REMOVED IN THEIR ENTIRETY. DEACTIVATED POINTS OF <br />CONNECTION ON ACTIVE LINES ARE TO BE CAPPED. <br />PLUMBING FIXTURE SCHEDULE <br />MARK DESCRIPITION <br />L-1 JUST MODEL B-21429 STAINLESS STEEL SINK 3 HOLES ON 4" CENTERS, <br />SPEAKMAN SEF-1800-8 EYESAVER FAUCET WITH 4" WRIST BLADE HANDLES <br />AND 8" GOOSENECK SPOUT. MCGUIRE #C8872C CAST BRASS "P" TRAP WITH <br />CLEAN OUT WITH BRASS CRAFT #SCR1912AC LOOSE KEY ANGLE STOPS. <br />ZURN CARRIER #Z-1231 WITH FLOOR MOUNTED BEARING PLATE. UNIT TO BE <br />SUPPLIED WITH TRUEBRO HANDICAP LAV-GUARD INSULATION <br />PLUMBING NEW WORK PLAN LEVEL THREE <br />Y8" =1'-0" <br />Project No. 10003.00 <br />P2,9 I <br />$DATE$ $TIME$ $FILEA$ <br />0 2009 BWPK Architects, Inc. <br />