My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (116)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (116)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:54:38 PM
Creation date
2/19/2025 11:44:30 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Sealander Contr
Building Plans - Permit #
10705
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIRE PROTECTION DEMOLITION PLAN LEVEL TWO <br />Y8" = 1'-0" <br />SPRINKLER BRANCH LINE OUTLET <br />(SPRINKLER OUTLET SHALL BE TO <br />THE SIDE, NOT DOWN.) <br />O <br />FLEXIBLE PIPE <br />TEE CLAMP, CENTER ON TILES AS INDICATED <br />ON ARCH. REFLECTED CEILING PLAN <br />CEILING TILE <br />CEILING GRID TEE <br />FLEXIBLE PIPE OPTION <br />PIPE CLAMP <br />1" CAST IRON - <br />SCR. 90 DEG. ELL <br />TYPICAL SPRINKLER HEAD <br />w <br />J <br />i1 <br />a <br />Y Z <br />U o <br />m V <br />�CO <br />1" CAST IRON SCR. 90 DEG. <br />ELL OR TEE (AS REQ'D) <br />U -- SPRINKLER BRANCH LINE PIPING <br />(SPRINKLER OUTLET MAY BE TURNED <br />DOWN, DEPENDING ON SITUATION.) <br />1" PIPING TO PENDENT SPRINKLER HEAD <br />LINE OF SUSPENDED CEILING <br />HARD PIPE OPTION <br />SUPPLY DETAIL FOR.SEMI RECESSED SPRINKLER HEADS <br />NTS <br />FIRE PROTECTION NEW WORK PLAN LEVEL TWO <br />y8" = 1' 011 <br />LEGEND <br />EXISTING PIPE <br />NEW PIPE <br />PIPING TO BE <br />REMOVED <br />NEW TO EXISTING <br />LIMIT OF REMOVAL <br />SPRINKLER SYMBOL DESCRIPTION <br />SYMBOL <br />SIZE <br />TYPE <br />RESP <br />FINISH <br />TEMP <br />K-FACTOR <br />O <br />Y2 <br />SSU <br />Q/R <br />BRASS <br />212 <br />5.6 <br />Y <br />SSP- <br />RECESSED <br />Q/R <br />CHROME <br />165 <br />5.6 <br />CONCEALED <br />Q/R <br />WHITE COVER PLT <br />165 <br />5.5 <br />GENERAL NOTES <br />1. THIS BUILDING SHALL BE PROTECTED THROUGHOUT BY AUTOMATIC <br />SPRINKLERS. THE DESIGN AND INSTALLATION SHALL BE IN ACCORDANCE <br />WITH NFPA 13, LATEST ENFORCEABLE EDITION. <br />2. ADHERE TO AND OBTAIN ALL PERMITS, LICENSES AND ALL GOVERNMENT <br />REQUIREMENTS. <br />3. ALL AREAS SHALL BE FIRE SPRINKLERED. THIS SHALL INCLUDE ELEVATOR <br />EQUIPMENT ROOMS, ELEVATOR SHAFT PIT, ELECTRICAL ROOMS, <br />TELEPHONE ROOMS, AND ANY CONCEALED SPACES OF COMBUSTIBLE <br />CONSTRUCTION. <br />4. REFER TO ARCHITECTURAL REFLECTED CEILING AND ELECTRICAL LIGHTING <br />DRAWINGS FOR CEILING DESCRIPTIONS AND HEIGHTS. <br />5. THE LOCATIONS OF SIAMESE CONNECTION, RISERS, FEED MAINS, CROSS <br />MAINS AND BRANCH PIPING WHERE SHOWN ON THE DRAWINGS IS APPROXIMATE. <br />FINAL LOCATION IS THE CONTRACTOR'S RESPONSIBILITY AND SHALL BE IN <br />COMPLIANCE WITH THE SPECIFICATIONS AND ALL APPLICABLE CODES OR <br />REGULATIONS. <br />6. PROVIDE HEADS GUARDS FOR SPRINKLERS IN ELECTRICAL ROOMS, ELEVATOR <br />MACHINE ROOMS AND ANY HEADS THAT ARE SUBJECT TO MECHANICAL DAMAGE <br />AND/OR BELOW T-0" <br />7. NOT ALL PIPING, VALVES AND APPURTENANCES ARE SHOWN ON PLANS. <br />REFER TO PIPING AND RISER DIAGRAMS, DETAILS AND SPECIFICATIONS <br />FOR ADDITIONAL INFORMATION. <br />8. INSPECTOR'S TEST CONNECTIONS SHALL BE PROVIDED FOR ALL ZONES SO <br />THAT THE WATER FLOW SWITCH FOR EACH ZONE CAN BE TESTED. <br />CONNECTIONS SHALL HAVE A MINIMUM 1 1/2 INCH OUTLET AND DRAIN <br />VALVE LOCATED IN AN ACCESSIBLE LOCATION PIPED TO AN APPROVED <br />LOCATION. <br />9. PROVIDE ACCESS PANELS TO ALL VALVES ABOVE NON- ACCESSIBLE CEILINGS <br />AND CHASES. <br />10. ALL VALVES ON THE FIRE PROTECTION SYSTEM TO BE ELECTRICALLY <br />SUPERVISED. TYPE AND EXACT LOCATION OF FLOW AND SUPERVISORY <br />SWITCHES SHALL BE ACCOMPLISHED BETWEEN THE DIFFERENT RESPONSIBLE <br />TRADES. <br />11. PROVIDE A PERMANENTLY ATTACHED NAME TAG STATING THE REQUIRED <br />DESIGN CRITERIA FOR EACH HYDRAULICALLY DESIGNED SYSTEM. <br />12. ALL SPRINKLER HEADS MOUNTED IN CEILING SHALL BE LOCATED A MINIMUM <br />OF 4" AWAY FROM ANY WALLS, CEILING HEIGHT CHANGES OR ANY OTHER <br />VERTICAL INTERSECTING STRUCTURAL SURFACE. <br />13. PROVIDE SPRINKLERS ABOVE AND BELOW EXPOSED DUCTWORK 48" OR <br />WIDER. <br />14. PROVIDE ADDITIONAL OFFSETS OR FITTINGS REQUIRED FOR PROPER <br />INSTALLATION, COORDINATION WITH OTHER TRADES, AND/OR TO MAINTAIN <br />PROPER CLEARANCES. VERIFY STRUCTURAL, MECHANICAL, ELECTRICAL <br />INSTALLATIONS TO AVOID OBSTRUCTIONS OR INTERFERENCE WITH FIRE <br />PROTECTION PIPE ROUTING. <br />15. FIRE STOP ALL PENETRATIONS OF SMOKE/FIRE WALLS. FIRESTOPPING SHALL <br />BE OF A U.L. LISTED ASSEMBLY. <br />16. SPRINKLER HEADS ARE TO BE COORDINATED WITH ALL DIFFUSERS, <br />SPEAKERS, LIGHTING FIXTURES, CEILING SYSTEMS AND STRUCTURAL <br />SYSTEM. <br />17. SPRINKLER SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT. NO <br />INSTALLATION SHALL BE PERMITTED UNTIL SPRINKLER SHOP DRAWINGS HAVE <br />BEEN APPROVED. <br />18. DESIGN CRITERIA: <br />A. ALL LIGHT HAZARD AREAS (OFFICES, TREATMENT ROOMS, ETC.) <br />SHALL BE HYDRAULICALLY DESIGNED FOR A DENSITY OF <br />0.10 GPM/SQ. FT. OVER THE MOST HYDRAULICALLY REMOTE 1,500 SQ. <br />FT. AND SHOULD INCLUDE A 100 GPM INSIDE HOSE STREAM ALLOWANCE. <br />B. ALL ORDINARY HAZARD AREAS (MECHANICAL ROOMS, STORAGE AREAS, <br />ETC.) SHALL BE HYDRAULICALLY DESIGNED FOR A DENSITY OF 0.20 <br />GPM/SQ. FT. OVER THE MOST HYDRAULICALLY REMOTE 1,500 SQ. FT. <br />AND SHOULD INCLUDE A 100 GPM INSIDE HOSE STREAM ALLOWANCE AND <br />A 150 GPM OUTSIDE HOSE STREAM ALLOWANCE. <br />20. UNLESS OTHERWISE NOTED, ALL SPRINKLER HEADS TO BE QUICK RESPONSE. <br />Project No. 10003.00 <br />F2. I <br />$DATE$ $TIME$ $FILER$ <br />2009 BH/PK Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.