Laserfiche WebLink
4 <br />3 <br />2 <br />1 <br />E <br />D I M <br />Lei <br />B <br />I <br />C) <br />0 <br />-) <br />�a <br />E <br />A <br />00 <br />Nt <br />`Oil <br />CD <br />J <br />rv„CD <br />C3 <br />r0 <br />4'-0" <br />v <br />co <br />° <br />9 <br />Q. <br />00 <br />e <br />° <br />M <br />a. <br />0 <br />co <br />9 1/2" <br />° <br />2'-0" 2'-4' <br />e. Oe <br />° .a a <br />00 <br />ti <br />9 e° e <br />N <br />la <br />° <br />e. <br />5'-01 /2" .. <br />2'4" <br />v <br />A 1 <br />I <br />I <br />a <br />ao <br />9 1/4" <br />2-0" �2'-3 1/4" <br />TV <br />4 , <br />(V <br />e <br />_=J v <br />°.< <br />N e <br />a a. <br />Md. e <br />N .; <br />2'4 1/2"1-1'-4 3/4" <br />iv 2'-7 1/4" 8'-7 1/4" <br />0 <br />LO <br />V-11 3/4" 2'-4 1/2" T-6 1/4" 2'-4 1/2" T-6 1/4" 2'4 1/2" V-7" <br />iv -v e v ° -v <br />-A­ <br />41co .e <br />17'-8 3/4" <br />A4 MILLWORK CURB PLAN <br />1/4" = 1'-0" <br />N <br />OD <br />LO <br />co <br />v <br />cM N <br />fV <br />rn <br />v <br />v 2 3/4" <br />M M- <br />N <br />u7 <br />a <br />4'-5 1/2" 2'-1 3/4" <br />1 R'-n <br />MILLWORK CURB LEGEND <br />1" CURB <br />3" CURB <br />5 1/2" CURB <br />- - - - - - - - - - -- - - 1 - - - - - - - 4'-0" <br />WALL TYPE SCHEDULE - INTERIOR <br />MARK <br />DESCRIPTION (DOES NOT INCLUDE FINISHES) <br />M6 <br />6" MTL STUDS @ 24" O.C. MAX, WITH ONE LAYER 1/2" SHEATHING EA EXPOSED <br />SIDE <br />M8 <br />8" MTL STUDS @ 24" O.C. MAX, WITH ONE LAYER 1/2" SHEATHING EA EXPOSED <br />SIDE <br />W4 <br />2x4 WD STUDS @ 24" O.C. MAX, WITH ONE LAYER 1/2" SHEATHING EA EXPOSED <br />SIDE <br />W4.1 <br />2x4 WD STUDS @ 24" O.C. MAX, WITH ONE LAYER 1/2" SHEATHING ON <br />INTERIOR SIDE <br />W6 <br />2x6 WD STUDS @ 24" O.C. MAX, WITH ONE LAYER 1/2" SHEATHING EA EXPOSED <br />SIDE <br />W8 <br />2x8 WD STUDS @ 24" O.C. MAX, WITH ONE LAYER 1/2" SHEATHING EA EXPOSED <br />SIDE <br />W66 <br />2X6 & 2X6 PAIR WD STUDS @ 24" O.C. MAX, WITH ONE LAYER OF 1/2" <br />SHEATHING EA EXPOSED SIDE <br />WALL TYPE SCHEDULE - EXTERIOR <br />MARK I DESCRIPTION (DOES NOT INCLUDE FINISHES) <br />SM6 <br />6" MTL STUD INFILL WITH 1/2" SHEATHING EA SIDE - REF STRUCT DRAWINGS <br />FOR CONSTRUCTION/MATERIAL/EXTENT INFORMATION <br />SM6.3 <br />6" MTL STUD EXTERIOR WALL WITH 1/2" SHEATHING ON EXTERIOR FACES - <br />REF STRUCT DRAWINGS AND ARCH SECTIONS/ELEVATIONS FOR <br />CONSTRUCTION/MATERIAL INFORMATION <br />SW6 <br />2X6 WD STUD EXTERIOR WALL WITH 1/2" SHEATHING EA SIDE - REF STRUCT <br />DRAWINGS AND ARCH SECTIONS/ELEVATIONS FOR <br />CONSTRUCTION/MATERIAL INFORMATION <br />SW6.2 <br />2X6 WD STUD EXTERIOR FURRING WALL WITH ONE LAYER 1/2" SHEATHING <br />EXPOSED SIDE - REF STRUCT DRAWINGS AND ARCH SECTIONS/ELEVATIONS <br />FOR CONSTRUCTION/MATERIAL INFORMATION <br />FLOOR PLAN GENERAL NOTES <br />A.1 DIMENSIONS <br />ARE FROM FACE OF STUD TO FACE OF STUD (UNLESS OTHERWISE NOTED). <br />A.2 FASTENERS, ANCHORS, CLIPS, STRAPS, ETC WHICH ARE IN CONTACT WITH <br />PRESERVATIVE <br />AND/OR FIRE TREATED WOOD SHALL BE OF G-185 HOT DIPPED ZINC - <br />COATED <br />GALVANIZED STEEL, STAINLESS STEEL, OR AN APPROVED EQUAL. <br />A.3 REFER <br />TO CIVIL AND LANDSCAPE FOR LOCATIONS OF WALKS, BOLLARDS, LANDSCAPING <br />AREAS, <br />FLAG POLE, AND OTHER SITE ITEMS. <br />A.4 REFER <br />TO INTERIOR ELEVATIONS FOR LOCATIONS AND TYPES OF CORNER GUARDS. <br />A.5 CONTRACTOR <br />TO COORDINATE LOCATION OF POLE MOUNTED EXTERIOR CAMERA WITH <br />STRONG SYSTEMS AND INSTALL UNDERGROUND CONDUIT AS REQUIRED. RE: <br />ELECTRICAL. <br />A.6 REFER <br />TO ACCESSIBILITY PLAN AND FURNITURE DRAWINGS FOR SEATING LAYOUT & <br />SPECIFICATIONS. <br />CONTACT: OWNER. <br />A.7 REFER <br />TO ACCESSIBILITY PLAN AND OWNER DRAWINGS FOR CONDIMENT COUNTERS <br />AND TRASH RECEPTACLES. <br />A.8 REFER <br />TO IT WALLBOARD USER GUIDE FOR WALLBOARD INSTALLATION, IF APPLICABLE. <br />FLOORPLAN <br />KEYNOTES O <br />1 <br />GC SHALL PROVIDE 5-1/2" HIGH CONCRETE MILLWORK CURBS. RE: OWNER SHOP <br />DRAWINGS FOR EXACT LOCATIONS & DIMENSIONS. <br />2 <br />GC SHALL SECURE SAFE USING (4) HILTI-HAS-E 1/2" x 4-1/2" ANCHOR BOLTS WITH HILTI <br />HVU ADHESIVE CAPSULE. AT EACH HOLE FASTEN THRU PHENOLIC BASE OF CABINET <br />AND INTO CONCRETE CURB BELOW. VERIFY LOCATION WITH SAFE MANUFACTURER. <br />3 <br />FREEZER AND COOLER DOORS AND HARDWARE SUPPLIED BY FREEZER/ COOLER <br />MANUFACTURER. <br />4 <br />DASHED LINE INDICATES SOFFIT OR BULKHEAD ABOVE, RE: REFLECTED CEILING PLAN. <br />5 <br />RECESSED PIN AND SLEEVE BOX, RE: A4/A-620 & ELECTRICAL. 2'-1" ROUGH OPENING <br />WIDTH AT HOOD #2. 11" ROUGH OPENING WIDTH AT HOOD #3 <br />8 <br />STEEL WALL BY OWNER (TYP.) RE: OWNER FOR EXACT LOCATION. <br />FLOOR PLAN WALL & <br />9 <br />SAFE SCREEN BY OWNER. <br />15 <br />NETWORK CABINET. C1 /A-621 <br />18 <br />ELECTRICAL PANEL. RE: ELECTRICAL. <br />PARTITION LEGEND <br />19 <br />ITEM BY OWNER. <br />20 <br />2-SIDED ICON. RE: OWNER DRAWINGS. <br />BATT INSULATION <br />22 <br />CANOPY ABOVE BY OWNER. <br />WOOD STUD WALL <br />23 <br />DROP SLAB IN PLAY AREA 1-1/2". RE: STRUCTURAL. <br />24 <br />MDP. RE: ELECTRICAL. <br />METAL STUD WALL <br />25 <br />CT CABINET. RE: ELECTRICAL. <br />NOTE: SEE WALL & PARTITION TYPES <br />26 <br />HAND SANITIZER CENTERED UNDER PLAY RULES SIGNAGE (WITH DECAL ON OPPOSITE <br />AND SMOKE BARRIER INDICATED ON <br />SIDE IF MOUNTED ON STOREFRONT). RE: SCHEDULE ON A-701 FOR MODEL INFO. <br />REFLECTED CEILING PLAN FOR <br />ADDITIONAL INFORMATION <br />.•.�.�.❖.•.:❖.•.�.�.❖.❖.❖.•.�.❖.❖.❖.❖.❖.❖.❖.❖.❖.❖.❖.❖.❖.�.•.�.❖.❖.❖.❖.❖.❖.❖.❖.❖.❖.❖.❖.❖.❖.❖.�.❖.❖.❖.❖.❖.❖.❖� <br />�� <br />E oOOo <br />A9")C0 <br />Chick-fil-A <br />5200 Buffington Road <br />Atlanta, Georgia <br />30349-2998 <br />C <br />WALL NOTES <br />WALL INSULATION NOTES <br />B.1 WHERE EXTERIOR METAL STUD WALL TYPE REQUIRES BATT INSULATION, USE R-19 UNFACED BATT INSULATION. <br />B.2 WHERE EXTERIOR WOOD STUD WALL REQUIRES BATT INSULATION, USE R-19 KRAFT FACED FIBERGLASS BATT <br />INSULATION WITH FLAME SPREAD INDEX OF NOT MORE THAN 25 AND SMOKE DEVELOPED INDEX OF NOT MORE <br />THAN 450. <br />B.3 WHERE EXTERIOR STUD WALLS REQUIRE BATT INSULATION, EXTEND INSULATION UP 12" ABOVE ROOFTOP RIGID <br />INSULATION. <br />B.4 AT INTERIOR METAL STUD WALLS WHERE INSULATION IS SCHEDULED, BATT INSULATION SHALL BE UNFACED. <br />B.5 AT INTERIOR WOOD STUD WALLS WHERE INSULATION IS SCHEDULED, USE 3-1/2" BATT INSULATION WITH MAXIMUM <br />FLAME SPREAD INDEX OF 25. <br />B6. NOT USED <br />INTERIOR WALL FRAMING NOTES <br />C.1 UNLESS NOTED OTHERWISE, EXTEND FRAMING TO 6" ABOVE ADJACENT CEILING <br />C.2 AT DRAFT STOPPING PARTITION INTERIOR WALLS, EXTEND FRAMING TO ROOF DECK AS REQUIRED TO <br />ACCOMMODATE SMOKE BARRIER. <br />C.3 WHERE INTERIOR WALLS ARE NOT INSULATED AND NOT A DARFT STOPPING PARTITION, FRAMING MAY <br />STOP 6" ABOVE HIGHEST ABUTTING FINISH CEILING. B <br />CA WHERE INTERIOR WALL FRAMING DOES NOT EXTEND TO STRUCTURE ABOVE, BRACE INTERIOR WALLS AS <br />REQUIRED FOR COMPLIANCE WITH BUILDING CODE, REF BUILDING DATA ON COVER SHEET. <br />C.5 FRAMING AT NON-LOADBEARING INTERIOR WALLS SHALL MEET REQUIREMENTS OF APPLICABLE BUILDING <br />CODES AND LOCAL AMENDMENTS. <br />EXTERIOR WALL FRAMING NOTES <br />D.1 SEE STRUCTURAL DRAWINGS FOR STUD DIMENSIONS AND SPACING. <br />D.2 AT WOOD STUD EXTERIOR WALLS, USE TREATED SILL PLATES. <br />EXTERIOR SHEATHING NOTES <br />E.1 REFER TO STRUCTURAL FOR EXTERIOR SHEATHING TYPES. <br />BLOCKING NOTES <br />F.1 WALL BLOCKING SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. BLOCKING SHALL INCLUDE, <br />BUT IS NOT LIMITED TO: AREAS INDICATED ON INTERIOR ELEVATIONS FOR GRAB BARS, SHELVING <br />BRACKETS, MONITORS, FIXTURES, ETC, AS WELL AS BLOCKING FOR WINDOWS, CANOPIES ROOF <br />FRAMING, ROOF TOP UNITS, ETC. <br />INTERIOR WALL FINISH & INTERIOR SHEATHING NOTES <br />AT MATERIALS LABELED "INTERIOR SHEATHING" ON WALL TYPE DRAWINGS AND DETAILS, SHEATHING SHALL BE AS <br />FOLLOWS UNLESS NOTED OTHERWISE. REFER TO FINISH PLAN AND INTERIOR ELEVATIONS FOR FINISH MATERIAL ON <br />INTERIOR SHEATHING. DO NOT USE WOOD SHEATHING WITHIN 18" OF HOODS. <br />G.1 WHERE SHEATHING IS EXPOSED: 1/2" GYPSUM BOARD. PAINTED PER INTERIOR ELEVATIONS AND FINISH PLAN. <br />G.2 BETWEEN WALL TILE AND STUDS: 1/2" CEMENTITIOUS BACKER BOARD. <br />G.3 BETWEEN FRP PANELS AND WOOD STUDS AT BACK OF HOUSE: COMPOSEAL GOLD 40 MIL WATERPROOF <br />MEMBRANE AND 1/2" CEMENTITIOUS BOARD TO V-0" ABOVE SLAB. 1/2" CDX PLYWOOD SUBSTRATE ABOVE <br />CEMENTIOUS BOARD TO V-0" ABOVE CEILING. RE: TYPICAL WALL BASE DETAIL. <br />GA BETWEEN FRP PANELS AND METAL STUDS: COMPOSEAL GOLD 40 MIL WATERPROOF MEMBRANE AND 1/2" <br />CEMENTIOUS BOARD TO V-0" ABOVE SLAB. 1/2" CEMENTITIOUS BOARD TO 4" ABOVE CEILING, EXCEPT AT AREAS <br />WHERE DRAFTSTOPPING IS REQUIRED. REFER TO DRAFTSTOPPING DETAILS FOR THOSE AREAS. <br />G.5 BETWEEN FRP PANELS AND WOOD STUDS AT PLAY AREA: 1/2" GYPSUM BOARD. <br />G.6 BETWEEN STAINLESS STEEL PANELS AND METAL STUDS: 1/2" CEMENTIOUS BOARD. <br />G.7 BETWEEN STAINLESS STEEL PANELS AND WOOD STUDS: 1/2" CEMENTIOUS BOARD. <br />G.8 BETWEEN WALLCOVERING AND STUDS: 1/2" GYPSUM BOARD. <br />G.9 BETWEEN WOOD WAINSCOT AND WOOD STUDS: 1/2" PLYWOOD. <br />G.10 BETWEEN WOOD WAINSCOT AND METAL STUDS: 1/2" PLYWOOD. A <br />G.11 BETWEEN FREEZER/COOLER WALLS AND WOOD STUD WALLS: 1 FT TALL CEMENT BOARD BASE WITH 1/2" GYPSUM <br />BOARD (LEVEL 1 FINISH) TO 6" ABOVE FINISH CEILING. EXTEND 40 MIL COMPOSEAL GOLD WATERPROOF MEMBRANE <br />FROM FLOOR AS INDICATED ON FINISH PLAN UP WALL AS INDICATED ON FREEZER AND COOLER SCREED DETAILS. <br />G.12 BEHIND WOOD BOARD FINISH AT ICON WALL: 3/4" PLYWOOD. <br />G.13 BEHIND WOOD BOARD FINISH AT OTHER LOCATIONS: 1/2" PLYWOOD. <br />INTERIOR BASE FINISH & SHEATHING NOTES <br />AT MATERIALS LABELED "INTERIOR SHEATHING" ON WALL TYPE DRAWINGS AND DETAILS, MATERIALS SHALL BE AS <br />FOLLOWS UNLESS NOTED OTHERWISE. REFER TO FINISH PLAN AND INTERIOR ELEVATIONS FOR BASE FINISH MATERIAL. <br />H.1 BETWEEN TILE BASE AT KITCHEN AND STUDS: 1/2" CEMENTITIOUS BACKER BOARD TO MINIMUM V-0" ABOVE <br />SLAB. <br />H.2 BETWEEN TILE BASE AT NON -KITCHEN AREAS AND STUD WALLS: 1/2" CEMENT BACKER BOARD TO MINIMUM <br />5" ABOVE SLAB. <br />H.3 BETWEEN VINYL BASE AND WOOD STUD WALLS: 1/2" GYPSUM BOARD. <br />�r�waw�ra.rw <br />rW ewrrm., <br />.Lewleegla <br />Digitally signed by Timothy <br />Burnett <br />DN: c=US, o=Unaffiliated, <br />ou=A01 100000001725CED62600 <br />0018011, cn=Timothy Burnett <br />Date: 2020.11.25 15:28:44-06001 <br />FSR#04040 <br />BUILDING TYPE / SIZE: P13 LC <br />RELEASE: V2 20.02 <br />REVISION SCHEDULE <br />NO. DATE DESCRIPTION <br />1 11/25/2020 FOR BID <br />CONSULTANT PROJECT # 17013 <br />PRINTED FOR PERMIT <br />DATE 07/29/2020 <br />H <br />DRAWN BY Author <br />Information contained on this drawing and in all digital files <br />produced for above named project may not be reproduced in <br />any manner without express written or verbal consent from <br />authorized project representatives. <br />W <br />SHEET <br />FLOOR PLAN <br />SHEET NUMBER <br />A=201 <br />F1 <br />3 1 2 <br />1 <br />