Notes: <br />GENERAL CONDITION AND STATEMENTS <br />1. THESE NOTES SHALL APPLY UNLESS OTHERWISE INDICATED BY DRAWINGS OR <br />SPECIFICATIONS. <br />2. STRUCTURAL DRAWINGS INDICATE TYPICAL AND CERTAIN SPECIFIC CONDITIONS <br />ONLY. SHOP DRAWINGS SHALL DETAIL ALL CONDITIONS IN ACCORDANCE WITH <br />SPECIFIED STANDARDS AND THE SPECIFIC REQUIREMENTS OF THIS PROJECT AS <br />INDICATED ON THE DRAWINGS. <br />3. SUBMIT SHOP DRAWINGS ON ALL MATERIALS FOR APPROVAL BEFORE FABRICATION. <br />CONTRACTOR SHALL REVIEW, APPROVE AND SIGN EACH SHEET PRIOR TO <br />SUBMISSION. <br />4. THE STRUCTURE SHOWN ON THESE DRAWINGS IS STRUCTURALLY SOUND ONLY IN <br />ITS COMPLETED FORM. THE CONTRACTOR SHALL TEMPORARILY BRACE ALL EARTH, <br />FORMS, CONCRETE, STEEL, WOOD, MASONRY, TO RESIST GRAVITY, EARTH, WIND, <br />SEISMIC AND CONSTRUCTION LOADS DURING CONSTRUCTION. <br />5. WHERE A DETAIL, TYPICAL DETAIL, SECTION, TYPICAL SECTION OR AS <br />NOTED IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL LIKE <br />OR SIMILAR CONDITIONS UNLESS OTHERWISE NOTED. <br />6. DESIGN CODES AND STANDARD SPECIFICATIONS: <br />BUILDING CODE 2004 FLORIDA BUILDING CODE WITH 2O05 AND 2006 <br />SUPPLEMENTS <br />STEEL STRUCTURE AISC LOAD RESISTANCE AND FACTOR DESIGN <br />SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS <br />THIRD EDITION <br />CONCRETE ACI 318-02 BUILDING CODE FOR STRUCTURAL CONCRETE <br />SPECIALTY ENGINEER REQUIREMENTS <br />1. THE FLORIDA STATE BOARD OF PROFESSIONAL ENGINEERS HAS ISSUED <br />STATEMENTS ON RESPONSIBILITIES OF PROFESSIONAL ENGINEERS, PURSUANT TO <br />RULE 61G15-30.005. <br />2. CERTAIN COMPONENTS OF THE STRUCTURE REQUIRE THE WORK OF A SPECIALTY <br />ENGINEER FOR THE DESIGN OF THOSE COMPONENTS. ALL PROCEDURES STATED <br />IN THE STATEMENTS SHALL APPLY TO THIS PROJECT. <br />3. PRE-ENGINEERED WALL AND ROOF PANELS SHALL BE DESIGNED, DETAILED, AND <br />ENGINEERED BY THE PANEL MANUFACTURER AND FABRICATOR. SHOP DRAWINGS <br />SHALL BE SUBMITTED FOR REVIEW AND MUST BE SIGNED AND SEALED BY A <br />REGISTERED ENGINEER IN THE STATE OF FLORIDA. <br />4. AWNING AND CANOPY ASSEMBLIES AND THEIR SUPPORT CONNECTIONS SHALL BE <br />DESIGNED BY THE FABRICATOR'S SPECIALTY ENGINEER. SHOP DRAWINGS SHALL BE <br />SUBMITTED FOR REVIEW AND MUST BE SIGNED AND SEALED BY A REGISTERED <br />ENGINEER IN THE STATE OF FLORIDA. DESIGN LOADS SHALL MEET THE MINIMUM <br />REQUIREMENTS OF THE GOVERNING BUILDING CODE. <br />SOILS <br />1. FOUNDATION DESIGN OF FOOTINGS BASED ON 2500 PSF (ASSUMED) SOIL <br />BEARING. <br />2. COMPACT ALL MATERIALS SUPPORTING SLAB ON GRADE OR FOOTINGS TO 95% <br />(100% FOR TOP 1 FOOT) OF MAXIMUM DENSITY BY STANDARD PROCTOR (ASTM <br />D-698). <br />SOILS TESTING LABORATORY SHALL CONDUCT COMPACTION TESTS ON ALL <br />STRUCTURAL FILL MATERIAL. <br />CONCRETE <br />1. MIX DESIGNS FOR EACH TYPE OF CONCRETE SPECIFIED SHALL BE SUBMITTED FOR <br />APPROVAL. ADMIXTURES, CURING COMPOUNDS AND HARDENERS WHICH ARE <br />INTENDED FOR USE ARE TO BE SUBMITTED FOR APPROVAL. <br />2. TESTING LABORATORY SHALL SAMPLE AND TEST CONCRETE AS FOLLOWS: 2. <br />SAMPLING: <br />GENERAL: IN ACCORDANCE WITH ASTM C31. <br />NO.: 4 CYLINDERS FOR EACH 50 CUBIC YARDS, 5000 <br />SQUARE FEET OF SURFACE AREA, OR EACH PLACEMENT OF <br />EACH MIX DESIGN OF CONCRETE PLACED IN ANY ONE DAY. <br />DESIGNATION: LABEL EACH CYLINDER IN EACH SET OF 4 <br />CYLINDERS WITH AN ALPHA -NUMERIC DESIGNATION, E.G., <br />THE FIRST SET SHALL BE NUMBERED 1A, 19, 1 C, AND 1 D. <br />TESTING: <br />SLUMP: IN ACCORDANCE WITH ASTM C 143, TO BE TAKEN <br />WHEN EACH SET OF CYLINDERS IS MADE. <br />AIR CONTENT: SEE SPECIFICATIONS. <br />COMPRESSIVE STRENGTH: IN ACCORDANCE WITH ASTM C 39. <br />BREAK ONE CYLINDER AT 7 DAYS, 2 AT 28 DAYS, AND HOLD <br />ONE IN RESERVE. EACH PAIR OF BREAKS FROM EACH SET OF <br />CYLINDERS WILL BE CONSIDERED ONE TEST. <br />TEST REPORTS SHALL BE AVAILABLE AT JOBSITE. <br />3. CONCRETE FOR FOOTINGS AND INTERIOR SLAB ON GRADE SHALL BE NORMAL <br />WEIGHT (145 PCF) WITH A 28 DAY COMPRESSIVE STRENGTH OF 3,000 PSI. <br />4. CONCRETE WORK SHALL CONFORM TO ACI 318 (REINF. CONCRETE) AND/OR <br />318.1 (PLAIN CONCRETE). <br />5. REINFORCING BARS SHALL CONFORM WITH ASTM A 615. BARS WELDED TO <br />STRUCTURAL STEEL SHALL CONFORM TO ASTM A706. ALL BARS SHALL BE <br />GRADE 60. PROVIDE CORNER BARS AT ALL GRADE BEAM CORNERS. LAP ALL <br />REINFORCING 48 BAR DIAMETERS AT SPLICES. <br />6. CONTROL JOINTS FOR SLAB ON GRADE SHALL BE LOCATED AS SHOWN ON PLAN. <br />JOINTS SHALL BE FORMED USING SAW CUTS 1/8" WIDE (MAX.) BY T/4 DEEP. <br />SAW CUT WITHIN 12 HOURS AFTER POURING. JOINTS SHALL BE FILLED WITH <br />SEMI -RIGID EPDXY JOINT FILLER - SEE SPECIFICATIONS. <br />7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-82 AND A-185. PROVIDE ALL <br />MATERIAL IN SHEETS. LAP ONE SQUARE + 2" AT ALL SPLICES. <br />8. FIBER REINFORCEMENT TO BE NOVAMESH 850 BLEND OF STEEL AND <br />POLYPROPYLENE FIBERS AS MANUFACTURED BY SI CONCRETE SYSTEMS. QUANTITY <br />OF FIBERS: ONE 24 POUND BAG OF NOVAMESH 850 FIBERS PER CUBIC YARD OF <br />CONCRETE. <br />STEEL <br />4. STRUCTURAL STEEL DETAILING, FABRICATION, AND ERECTION TO BE IN <br />ACCORDANCE WITH THE "LOAD AND RESISTANCE FACTOR DESIGN SPECIFICATION <br />FOR STRUCTURAL STEEL BUILDINGS" OF THE AMERICAN INSTITUTE OF STEEL <br />CONSTRUCTION. <br />STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A572 OR A992 GRADE <br />50. <br />STEEL ANGLES, PLATES AND CHANNELS SHALL CONFORM TO ASTM A36 <br />TUBES TO BE ASTM A-500 GRADE B. <br />ANCHOR RODS SHALL CONFORM TO ASTM F1554 GRADE 36. <br />2. SUBMIT SHOP DRAWINGS FOR FABRICATION AND ERECTION OF ALL STEEL <br />MEMBERS IN ACCORDANCE WITH AISC STANDARDS NOTED ABOVE. SHOP <br />DRAWINGS SHALL GIVE COMPLETE WELDING INFORMATION, BOTH SHOP AND FIELD, <br />USING AWS SYMBOLS. WELDING ELECTRODES SHALL CONFORM TO AWS A5.1 OR <br />A5.5 E-70XX. <br />UNLESS NOTED OTHERWISE ON DRAWINGS CONNECTIONS ARE TO BE MADE WITH <br />3/4" DIA. A325 TYPE N BOLTS. <br />3. STRUCTURAL STEEL CONNECTIONS SHALL BE DETAILED BASED ON THE <br />INFORMATION PROVIDED IN THE CONTRACT DOCUMENTS. ALL LOADS INDICATED <br />ARE FACTORED REACTIONS. <br />3.1 WHERE NO VERTICAL REACTION IS INDICATED THE CONNECTION IS TO BE <br />DESIGNED TO SUPPORT A MINIMUM VERTICAL FACTORED REACTION OF 15 <br />KIPS. <br />3.2 STRUCTURAL STEEL CONNECTIONS NOT SPECIFICALLY DETAILED ON THE <br />STRUCTURAL 3.2 DRAWINGS SHALL BE DESIGNED BY THE CONTRACTOR. <br />THIS DESIGN SERVICE SHALL BE INCLUDED IN THE CONTRACTOR'S SCOPE <br />OF SERVICES. SHOP DRAWINGS FOR BRACING CONNECTIONS, COLLECTOR <br />ELEMENT CONNECTIONS WHERE AXIAL FORCES ARE INDICATED, AND <br />MOMENT CONNECTIONS SHALL BE SEALED BY A PROFESSIONAL ENGINEER <br />LICENSED IN THE PROJECT STATE WHO IS RESPONSIBLE FOR THE <br />CONNECTION DESIGN. <br />SUBMIT SHOP DRAWINGS FOR STEEL CONNECTIONS WITH PROFESSIONAL <br />ENGINEER'S SEAL TO THE BUILDING OFFICIAL. <br />4. MECHANICAL FASTENER NOTES: <br />4.1 WEDGE ANCHORS SHALL BE INSTALLED WITH A MINIMUM EMBEDMENT OF <br />6 X ANCHOR DIAMETER. WEDGE ANCHORS SHALL BE FORMED FROM <br />STEEL CONFORMING TO ASTM A510 AND SHALL DEVELOP ALLOWABLE <br />DESIGN FORCES EQUAL TO OR GREATER THAN HILTI KWIK BOLT II. <br />WEDGE ANCHORS INSTALLED IN CMU SHALL BE INSTALLED IN CELLS <br />FILLED WITH GROUT. GROUT SHALL EXTEND A MINIMUM OF 4' ALL <br />SIDES OF ANCHOR. <br />4.2 EPDXY ANCHORS SHALL BE INSTALLED WITH A MINIMUM EMBEDMENT OF 8 <br />X ANCHOR DIAMETER. ANCHOR RODS SHALL BE ASTM A36 THREADED <br />ROD. INSTALLED ANCHORS SHALL DEVELOP ALLOWABLE DESIGN FORCES <br />EQUAL TO OR GREATER THAN HILTI HY 150. HOLES SHALL BE CLEANED <br />AND ANCHORS INSTALLED IN ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS. <br />LIGHT GAGE METAL FRAMING <br />1. COLD FORMED METAL STUDS SHALL BE MANUFACTURED IN ACCORDANCE WITH <br />THE STANDARDS OF THE STEEL STUD MANUFACTURERS ASSOCIATION. STUDS <br />SHALL BE MANUFACTURED FROM STEEL CONFORMING TO ASTM A653 WITH A <br />MINIMUM YIELD STRENGTH OF 50 KSI. <br />WOOD FRAMING <br />1. ALL TIMBER CONNECTORS SHALL BE SIMPSON "STRONG -TIE" (OR EQUIVALENT - <br />SUBMIT FOR APPROVAL). CONNECTORS SHALL BE INSTALLED WITH QUANTITY AND <br />SIZE OF FASTENERS FASTENERS IN ACCORDANCE WITH MANUFACTURERS <br />REQUIREMENTS. CONNECTORS INSTALLED IN CONTACT WITH PRESSURE TREATED <br />WOOD SHALL HAVE SIMPSON ZMAX GALVANIZED COATING ( G185 HDG PER ASTM <br />A653 ). FASTENERS USED IN CONNECTORS WITH PRESSURE TREATED WOOD SHALL <br />BE HOT DIPPED GALVANIZED. <br />2. ALL FRAMED LUMBER SHALL BE SOUTHERN PINE GRADE NO. 2 (SURFACED AT <br />19% MOISTURE CONTENT) OR BETTER. ALL TIMBER IN CONTACT WITH CONCRETE <br />SHALL BE PRESSURE TREATED. <br />3. ALL FASTENERS IN CONTACT WITH PRESSURE TREATED WOOD INCLUDING <br />ANCHOR BOLTS, WASHERS AND NAILS SHALL BE HOT DIPPED GALVANIZED. <br />AGRI-PANEL WALL AND ROOF PANELS <br />1. LOAD BEARING AGRI-PANEL WALL AND ROOF PANELS SHALL BE AS <br />MANUFACTURED BY AGRIBOARD INDUSTRIES. <br />2. PANELS SHALL BE 7 7/8" THICK WITH A WEIGHT OF 14 PSF. PANEL SHEATHING <br />SHALL BE 7/16" OSB. PANEL PERIMETER AND ADDED PROFILE BOARDS SHALL <br />BE 3 1/2" x 7" TIMBERSTRAND LSL AS MANUFACTURED BY TRUS JOIST. <br />3. WALL AND ROOF OPENINGS SHALL BE FACTORY CUT WITH SUPPLEMENTAL <br />TIMBERSTRAND MEMBERS INSTALLED IN THE PANELS AT TIME OF FABRICATION AS <br />REQUIRED BY AGRIBOARD AGRIBOARD INDUSTRIES TO SUPPORT ALL VERTICAL, <br />SHEAR AND LATERAL LOADS. <br />4. AGRI-PANEL INSTALLATION SHALL BE PERFORMED IN ACCORDANCE WITH THE <br />MANUFACTURER'S RECOMMENDED PANEL INSTALLATION PROCEDURES. <br />5. INSPECTION OF APPLICATION OF GLUE TO THE KEYWAYS SHALL BE PERFORMED <br />FOR ALL PANEL JOINTS BY AN INDEPENDENT TESTING LABORATORY. <br />6. AGRIBOARD ROOF PANELS SHALL BE ENGINEERED TO SUPPORT ALL HVAC <br />EQUIPMENT, WIND UPLIFT LOADS AND LATERAL DIAPHRAGM LOADS. COORDINATE <br />WITH ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ALL ROOF MOUNTED <br />EQUIPMENT LOCATIONS. <br />7. AGRIBOARD WALL PANELS SHALL BE ENGINEERED TO SUPPORT VERTICAL, SHEAR <br />AND OUT OF PLANE (TRANSVERSE) LOADS. TIMBERSTRAND AND OR 2x LUMBER <br />REINFORCEMENT" SHALL BE LOCATED AROUND OPENING AND AS REQUIRED FOR <br />ALL CODE REQUIRED LOADS. <br />8. SUBBIT SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS FOR ALL <br />AGRI-PANEL ROOF AND WALL PANELS FOR REVIEW PRIOR TO FABRICATION. <br />INDICATE ALL OPENING DIMENSIONS AND TIMBERSTRAND REINFORCEMENT AT <br />OPENINGS. INDICATE ALL CONNECTION DETAILS INCLUDING GLUE LOACATIONS AND <br />QUANTITIES AND ALL MECHANICAL FASTENERS. INDICATE ALL CONNECTIONS OF <br />AGRI-PANELS TO SUPPORTING CONCRETE,WOOD AND STEEL STRUCTURE. <br />DESIGN LOADS: <br />ROOF DEAD LOAD <br />ROOFING <br />AGRI-PANEL <br />SUSPENDED <br />TOTAL DEAD LOAD <br />LIVE LOAD <br />WIND LOAD: <br />WIND SPEED <br />WIND IMPORTANCE FACTOR <br />WIND EXPOSURE <br />WIND BASE SHEAR <br />WALL COMPONENT DESIGN WIND PRESSURE 0 H=13'-O' <br />2 PSF <br />14 PSF <br />6 PSF <br />22 PSF <br />20 PSF <br />110 MPH <br />IW = 1.0 <br />C <br />Vx = 15.2k <br />Vy = 10.9k <br />WIND AREA (FT ) 2 <br />ZONE <br />PRESSURE (PSF) <br />ZONE <br />PRESSURE (PSF) <br />0 - 20 FT 2 <br />4 <br />+28.7 - 31.1 <br />5 <br />+ 28.7 - 38.3 <br />21 50 FT 2 <br />4 <br />+27.4 -29.8 <br />5 <br />+27.4 -35.6 <br />2 <br />51 - 100 FT <br />4 <br />+ 25.7 - 28.1 <br />5 <br />+ 25.7 - 32.3 <br />2 <br />101 - 150 FT <br />4 <br />+ 24.5 - 26.9 <br />5 <br />+ 24.5 - 29.8 <br />151 - 200 FT 2 <br />4 <br />+ 23.7 - 26.1 <br />5 <br />+ 23.7 - 28.3 <br />> 200 FT 2 <br />4 <br />+ 23.2 - 25.6 <br />5 <br />+ 23.3 - 27.3 <br />WALL LENGTH <br />5-0- 5'-0" <br />LnI ILn <br />WIc� <br />z ZONE 4 z <br />l 0 <br />0 I ►�I <br />NI <br />J <br />3 <br />WALL COMPONENT DIAGRAM <br />VERTICAL JOINT <br />4-" R4 STAR HEAD SCREWS - <br />C. MAXIMUM PLACED 1%" M4" <br />) OF PANEL ANGLED ® 15'. <br />M 6" O.C. EACH SIDE OF WALL <br />IY PANEL MANUF'R.) <br />rwniovnnu nu -APPLY" GLUE BEAD <br />3 SIDES OF KEY TO EACH PANEL AND <br />FASTEN WITH 12/14 x 4-" R4 STAR <br />HEAD SCREW THROUGH KEY AT 12" O.C. <br />MAXIMUM (DESIGN BY PANEL MANUF'R.) <br />NQM <br />MINIMUM CONNECTION SHOWN. <br />PANEL MFR. SHALL VERIFY CONNECTION <br />WITH DIAPHRAGM LOADING <br />GR-PANEL JOINT PLAN DETAIL <br />SCALE: 1" = 1'-0" <br />COUNTERSINK BOLT Hr-"", <br />OVER TIMBERSTRAND <br />HSS ViJi <br />CAP PL ) "%4%0'-9><i' <br />W/ (2) X"0 THRU B( <br />0 SIM. ROTATE 90' <br />HSS 4X4 <br />CAP PL 72"xWxO'-1( <br />W/ (2) X"0 THRU BC_ _ <br />0 SIM ROTATE 90' <br />CORNER JOINT <br />SIMPSON TP311 - (3) LOCATIONS <br />MINIMUM AT TOP, MID -HEIGHT AND <br />BOTTOM OF WALL (SEE AGRIBOARD <br />SHOP DWGS FOR ACTUAL NUMBER OF <br />CONNECTORS) <br />)F PANEL <br />UF'R <br />IPES W/ ROOF <br />N <br />SEE PLAN <br />SECTION - COLUMN CAP <br />SCALE: 1" = 1'-0" <br />SIMPSON MSTC28 - <br />CENTER ON PANEL J1 <br />VERTICAL PANEL JOINT <br />I <br />Go <br />I <br />12/14 x 4," R4 STAR HEAD SCREWS <br />0 12" O.C. MAXIMUM PLACED 1%" M4" <br />FROM END OF PANEL ANGLED 0 15'. <br />STAGGER ® 6" O.C. EACH SIDE OF WALL <br />(DESIGN BY PANEL MANUF'R.) <br />AGRIBOARD KEY - APPLY )6" GLUE BEAD <br />3 SIDES OF KEY TO EACH PANEL AND <br />FASTEN WITH 12/14 x 4W R4 STAR <br />HEAD SCREW THROUGH KEY AT 12" O.C. <br />MAXIMUM (DESIGN BY PANEL MANUF'R.) <br />NOTE: <br />MINIMUM CONNECTION SHOWN. <br />PANEL MFR. SHALL VERIFY CONNECTION <br />WITH DIAPHRAGM LOADING <br />AGRI-PANEL HORIZONTAL ROOF <br />PANEL JOINT PLAN -DETAIL <br />SCALE: 1" = 1'-0" <br />2 <br />SEE ARCH s' <br />T.O. PARAPET <br />(3) 10d NAILS PER - <br />CONNECTION <br />2x4 STUDS AT 16" O.C. <br />2x4 BOTTOM PLATE RIP <br />TO SLOPE, NAIL TO ROOF <br />PANEL W/ 16d NAILS AT <br />8" O.C. <br />LTP5 BY SIMPSON AT EVERY <br />THIRD STUD, CENTER OVER <br />TOP OF ROOF PANEL <br />SEE PLAN <br />PANEL BRG. ELEV. <br />3(6" STRUCTURAL GRADE 1 PLYWOOD WALL <br />SHEATHING. ATTACH TO WALL MEMBERS W/ 8d <br />NAILS 0 6" O.C. EDGES AND 12" O.C. INTERMEDIATE. <br />LAYOUT STAGGERED AND PERPENDICULAR <br />TO WALL MEMBERS <br />5/8" STRUCTURAL GRADE 1 PLYWOOD ROOF DECK. <br />ATTACH TO ROOF MEMBERS W/ 8d RING SHANK <br />NAILS 0 4" O.C. EDGES AND 6" O.C. INTERMEDIATE. <br />LAYOUT STAGGERED AND PERPENDICULAR TO ROOF <br />MEMBERS <br />2x4 KICKER AT 16" O.C. <br />1� <br />1 <br />(2) 1Od TOE NAILS PER CONNECTION <br />H2.5 BY SIMPSON AT EVERY OTHER 2x4 <br />AGRIBOARD ROOF PANEL <br />CONNECTION BY PANEL MFR. <br />MINIMUM V0 x 11" LONG LAG <br />SCREWS 0 24" O.C. <br />CONT. (2) 2x6 TOP AND BOTTOM <br />W/ V0 THRU-BOLTS W/ WASHERS <br />AND DOUBLE NUT AT 24" O.C. <br />(RIP TOP PLATES TO <br />LOAD BEARING AGRIBOARD WALL PANEL <br />AGRI-PANEL ROOF PANEL AND PARAPET <br />LOAD BEARING WALL SECTION DETAIL <br />SCALE: 1" = 1'-0" <br />3 <br />s� <br />12/14 x 4," R4 STAR HEAD SCRE <br />0 12" O.C. PLACED 1%" iV FR01 <br />END OF PANEL ANGLED 0 15% <br />STAGGER ® 6" O.C. EACH SIDE OF <br />AGRI-PANEL JOINT <br />""r' ROOF <br />L VERTICAL <br />IT <br />AGRIBOARD KEY APPLY ) GLUE Blru, <br />3 SIDES OF KEY TO EACH PANEL <br />►ttt;:.���;n��l <br />PANEL <br />Revisions: <br />Seal: <br />W"Ap <br />-71111141 <br />Consultants: <br />DESIGN PANEL FOR <br />ADDITIONAL 165 PLF <br />WIND LOAD IN EACH D E C A R O W I L L S O N <br />DIRECTION STRUCTURAL ENGINEERS <br />1 725 E. 5TH AVENUE, TAMPA, FLORIDA 33605 <br />PHONE (81 3) 24B-8080 FAX (81 3) 248-8081 <br />CERTIFICATE OF AUTHORIZATION # 25B96 <br />J❑HN L. DECAR❑, P.E. No. 56031 <br />1BOARD KEY TO HSS COL <br />POWER ACTUATED FASTENERS <br />00 <br />1 740 <br />♦ • <br />.E L E M E N T 6 <br />I♦ <br />%I <br />1 <br />ARCHITECTS -INTERIOR DESIGNERS <br />Tampa Office <br />The Edgewater Building <br />600 South Magnolia Avenue <br />Suite 150 <br />Tampa, Florida 33606 <br />Phone �813 <br />813) 251-0565 <br />Fox 251-0567 <br />Miami Office <br />1699 Coral Way suite 503 <br />Miami, Florida 33145 <br />Phone 305 858-5858 <br />Fax (305) 858-5850 <br />ELEMENTS State License eAA0002341 <br />WACHOVIA - ZEPHYR COMMONS <br />PARCEL 6 <br />US ROUTE 301 <br />ZEPHYRHILLS, FLORIDA <br />Drawing No./Date 11-26-08 <br />S1 <br />01-011 <br />Drawing Title/Scale/Drawn by <br />GENERAL NOTES <br />& TYPICAL DETAILS <br />SCALE: AS NOTED <br />SCALE: 1" = 1'-0" SCALE: 1" = 1'-0" <br />FOR PERMIT 12/01/08 . . <br />AGRI-PANEL VERTICAL JOINT <br />DETAIL HSS COLUMN. <br />