SECURITY SYSTEM NOTES
<br />CABLE SECURITY SYSTEM OUTLET BOX LEGEND
<br />Notes:
<br />Revisions:
<br />DATA CABLING
<br />120V 20A SINGLE
<br />5-20R W/TRUE
<br />ISOLATED GROUND
<br />CIRCUIT B-16
<br />MODULAR DATA JACK BOX
<br />REQUIRES 1 IP CONNECTION'
<br />AND 1 ANALOG LINE.
<br />BY OWNER 5'-0"
<br />AFF
<br />c
<br />0
<br />0
<br />0
<br />c
<br />c
<br />01
<br />n
<br />73
<br />r�
<br />LL
<br />s
<br />U
<br />O
<br />C
<br />U:
<br />C
<br />0
<br />U
<br />/
<br />O
<br />U
<br />N
<br />N
<br />00
<br />c
<br />/
<br />WIRE GUTTER PULL BOX
<br />12" X 24"
<br />BY CONTRACTOR
<br />DMP XR500E
<br />SECURITY PANEL
<br />18" X 30"
<br />BY OWNER
<br />2" ALARM CABLE CONDUIT
<br />BATTERY ENCLOSURE
<br />18" X 30"
<br />BY OWNER
<br />KEYPAD
<br />KEYPAD
<br />4'
<br />6'-0"
<br />A. PRIOR TO ELECTRICAL ROUGH -IN OR RELOCATION, ELECTRICAL
<br />CONTRACTOR SHALL VERIFY EXACT LOCATIONS, MOUNTING
<br />LOCATIONS, MOUNTING HEIGHTS, ELECTRICAL REQUIREMENTS, ETC.
<br />FOR BANK EQUIPMENT (DATA, SECURITY, DRIVE -UP TELLER WINDOW,
<br />PNEUMATIC -TELLERS, ATM, ETC.). ANY ADJUSTMENTS IN EQUIPMENT
<br />LOCATIONS PRIOR TO INSTALLATION SHALL BE PERFORMED AT NO
<br />EXTRA COST TO THE OWNER.
<br />B. IF OWNER DECIDES TO RELOCATE ANY EQUIPMENT, WALLS, ETC.
<br />AFFECTING THE LOCATION OF SECURITY SYSTEM JUNC11ON BOXES
<br />OR CONDUIT, THE CONTRACTOR SHALL ADJUST SECURITY SYSTEM
<br />ACCORDINGLY TO ACCOMODATE SUCH CHANGES. IF CHANGES ARE
<br />MADE AFTER INSTALLATION OF THE SECURITY SYSTEM, THE
<br />CONTRACTOR SHALL INCLUDE SUCH CHANGES IN THE CHANGE
<br />ORDER TO THE CONTRACT.
<br />C. THE SECURITY SYSTEM SHOWN ON THESE PLANS IS SCHEMATIC AND
<br />QUANTITIES OF DEVICES MAY VARY DEPENDING ON THE SIZE AND
<br />COMPLEXITY OF THE SPECIFIC BUILDING.
<br />D. NOT USED.
<br />E. ELECTRICAL CONTRACTOR SHALL VERIFY EXACT SIZES, DIMENSIONS,
<br />LOCATIONS AND MOUNTING OF BOXES WITH SECURITY SYSTEM
<br />VENDORS' SHOP DRAWINGS PRIOR TO ROUGH -IN.
<br />F. ALL VAULT CONDUIT TO BE CONTAINED WITHIN VAULT FLOOR,
<br />WALLS, OR CEILING. ALL CONDUIT FOR THE ALARM SYSTEM,
<br />SECURITY EQUIPMENT, LIGHTING, TELEPHONE, ETC. ENTERING THE
<br />VAULT WALLS, CEILING OR FLOOR SHALL HAVE AT LEAST ONE
<br />OFFSET WITHIN THE VAULT STRUCTURE. ARRANGEMENT OF BENDS
<br />SHALL BE SO THAT DRAINAGE IS TO THE EXTERIOR. SEE NATIONAL
<br />ELECTRICAL CODE FOR FURTHER INFORMATION.
<br />G. NO PVC CONDUIT WILL BE ALLOWED FOR ALARM CONDUIT AND NO CONDUIT
<br />SMALLER THAN 3/4" SHALL BE USED.
<br />H. ALL JUNCTION BOXES MUST HAVE BLANK COVER PLATE INSTALLED.
<br />1. ALL SECURITY OUTLETS SHALL HAVE COVER PLATES TO MATCH OUTLETS.
<br />J. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL SECURITY CABLE
<br />IN ALL SECURITY CONDUITS.
<br />BANK EOUIPMENT NOTES
<br />BANK EQUIPMENT, INSTALLATION, AND SYSTEM REQUIREMENTS DRAWINGS FORM A PART
<br />OF THESE CONTRACT DOCUMENTS. ELECTRICAL SUBCONTRACTOR SHALL PROVIDE A
<br />CONDUIT AND CABLING SYSTEM AS INDICATED ON THE ELECTRONIC SECURITY AND
<br />SURVEILLANCE CABLE SCHEDULE, THE SECURITY SYSTEM BOX LEGEND, AND AS INDICATED
<br />ON THE DRAWINGS. BANK EQUIPMENT SUPPLIER SHALL PROVIDE DEVICES AND OTHER
<br />ASSOCIATED EQUIPMENT, AND MAKE FINAL CONNEC11ONS FOR A COMPLETED SYSTEM.
<br />CONRDENTIALITY STATEMENT
<br />ALL DRAWINGS, DOCUMENTATION, AND INFORMATION CONTAINED HEREIN AND
<br />ALL EXHIBITS AND ATTACHMENTS HERETO, IN WHOLE OR IN PART, SHALL
<br />REMAIN THE SOLE AND EXCLUSIVE PROPERTY OF WACHOVIA CORPORATION,
<br />ITS AFFILIATES AND AUTHORIZED AGENTS. ALL INFORMATION, DOCUMENTATION,
<br />AND DRAWINGS CONTAINED HEREIN ARE TO BE KEPT IN STRICT CONFIDENCE.
<br />REPRODUCTION OR DISTRIBUTION OF WACHOVIA CORPORATION INFORMATION,
<br />DRAWINGS, OR DOCUMENTATION FOR ANY PURPOSE IS NOT PERMITTED WITHOUT
<br />PRIOR WRITTEN CONSENT FROM THE DIRECTOR OF SECURITY OR THE SECURITY
<br />EQUIPMENT MANAGER. IN THE EVENT OF BREACH OF THE CONFIDENTIALITY
<br />PROVISIONS CONTAINED HEREIN, WACHOVIA CORPORATION SHALL BE ENTITLED
<br />TO ANY REMEDY AVAILABLE TO IT AT LAW OR EQUITY, INCLUDING BUT NOT
<br />LIMITED TO INJUNCTIVE RELIEF.
<br />10
<br />ALARM SYSTEM TERMINAL BOARD
<br />2O
<br />IT RACK BY OWNER
<br />39
<br />NOT USED
<br />©
<br />9
<br />TL30 SURVEILLANCE CAMERA - PEDESTAL MOUNTED IN THE CEILING. NO BOX REQUIRED.
<br />©
<br />O
<br />ATM TRANSACTION CAMERA - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH WITH WALL 600AFF
<br />ON THE RIGHT SIDE OF THE ATM VIEWED FROM THE REAR, 3/40C. TO ABOVE CEILING.
<br />©
<br />®
<br />ATM SURVEILLANCE CAMERA - MAKE CONNECTION TO CAMERA HOUSING (GE #DR2) PROVIDED BY OTHERS.
<br />PROVIDE 3/4" RIGID CONDUIT FROM CAMERA HOUSING TO INSIDE BUILDING.
<br />El
<br />®
<br />AHD SURVEILLANCE CAMERA - MAKE CONNECTION TO CAMERA HOUSING (GE #DR2) PROVIDED BY OTHERS.
<br />PROVIDE 3/4" RIGID CONDUIT FROM CAMERA HOUSING TO INSIDE BUILDING.
<br />O
<br />AHD SURVEILLANCE CAMERA - PEDESTAL MOUNTED IN THE CEILING. NO BOX REQUIRED.
<br />©
<br />O
<br />DRIVE/THRU REMOTE UNIT CAMERA - UNIT MOUNTED.
<br />©
<br />3®
<br />VAULT SURVEILLANCE CAMERA - PEDESTAL MOUNTED. NO BOX REQUIRED..
<br />3J
<br />NOT USED.
<br />©
<br />3©
<br />NOT USED.
<br />©
<br />O
<br />LOBBY CAMERA - MOUNTED IN CEILING. NO BOX REQUIRED.
<br />VENDOR TO SELECT CAMERA TO FIT IN ENCLOSURE WHICH MAXIMIZES VIEWING AREA.
<br />COORDINATE WITH WACHOVIA.
<br />®
<br />NOT USED.
<br />©
<br />39
<br />TELLER LINE CAMERA - MOUNTED IN CEILING. NO BOX REQUIRED.
<br />©
<br />O4
<br />DRIVE/THRU TELLER CUSTOMER UNIT MONITOR - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH
<br />WITH WALL 18" ABOVE COUNTER TOP ON THE RIGHT AND/OR LEFT SIDE OF THE DRIVE/THRU WINDOW.
<br />3/4"C. TO ABOVE CEILING.
<br />O5
<br />HOLD-UP BUTTON - WIRELESS
<br />�A
<br />©
<br />VAULT VENTILATOR DURESS ALARM. PROVIDE 1/2"C FROM UNIT TO ABOVE CEILING.
<br />�B
<br />0
<br />VAULT SOUND DETECTOR - 4X4 BOX NTH 1 GANG PLASTER RING MOUNTED FLUSH WITH THE CEILING.
<br />�A
<br />®
<br />VAULT DOOR ALARM - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED ON VAULT STEEL CEILING.
<br />�B
<br />O9
<br />AFTER HOUR DEPOSITORY ALARM - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH WITH WALL.
<br />CENTERED OVER NIGHT DEPOSITORY CHEST AT 70"AFF. 3/4"C. TO ABOVE CEILING.
<br />©
<br />10
<br />ATM MACHINE ALARM - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH WITH WALL 12" AFF
<br />ON THE RIGHT SIDE OF THE ATM VIEWED FROM THE REAR. 3/4"C. TO ABOVE CEILING.
<br />©
<br />11
<br />MAIN TELEPHONE BOARD - NO JUNCTION BOX REQUIRED, CONDUIT RUN TO TELEPHONE
<br />EQUIPMENT BOARD AND TERMINATE WITH BUSHING.
<br />�A
<br />12
<br />ALARM INDICATOR LIGHT (BY SECURITY VENDOR)- 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH
<br />IN WALL 64"AFF AND WITHIN 6" OF THE STRIKE SIDE OF THE DOOR FRAME. 3/40C. TO ABOVE CEILING.
<br />❑B
<br />13
<br />ROOF HATCH CONTACTS - 4X4 BOX WITH COVER MOUNTED ADJACENT TO ROOF HATCH.
<br />�B
<br />14
<br />SAFE - 4X4 BOX WITH 2 GANG PLASTER RING MOUNTED 75" AFF. 3/4" FLEX TO SAFE.
<br />3/4"C. TO ABOVE CEILING.
<br />15
<br />POWER RECEPTACLE AT JB-4 4X4 BOX WITH 1 GANG COVER MOUNTED 18" ABOVE DRIVE/THRU COUNTER
<br />TOP TO THE RIGHT AND/OR LEFT OF JBO .
<br />©
<br />16
<br />MSK KEYPAD - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH WITH WALL 54" AFF.
<br />3/4"C. TO ABOVE CEILING.
<br />©
<br />17
<br />WALL MOUNTED MONITOR (BY SECURITY VENDOR) - 4x4 BOX WITH 1-GANG PLASTER RING MOUNTED
<br />90" AFF. 3/4"C. TO ABOVE CEILING. MOUNT OUTLET HORIZONTALLY.
<br />©
<br />18
<br />NOT USED
<br />❑A 19 CASH DISPENSER MACHINE - 4X4 BOX WITH 1 GANG PLASTER RING MOUNTED FLUSH WITH WALL 18" AFF.
<br />3/4"C. TO ABOVE CEILING.
<br />20 CEILING MOUNTED MOTION DETECTOR - 4" OCTAGON BOX MOUNTED FLUSH WITH THE CEILING.
<br />❑A 21 WALL MOUNTED MOTION DETECTOR - 4x4 BOX WITH 1-GANG PLASTER RING MOUNTED 6" BELOW CEILING.
<br />3/40C. TO ABOVE CEILING.
<br />ELECTRONIC SECURITY AND SURVEILLANCE
<br />CABLE
<br />SCHEDULE
<br />'CABLE
<br />TYPE
<br />DESCRIPTION
<br />BELDEN TIE
<br />CSC #
<br />❑A
<br />PVC
<br />#22 GAUGE, 4 CONDUCTORS, STRANDED,
<br />6502UE
<br />FOIL SHIELD WITH DRAIN, COLOR CODED.
<br />©
<br />PVC
<br />18 GAUGE, 8 CONDUCTORS, STRANDED,
<br />6306UE
<br />FOIL SHIELD WITH DRAIN, COLOR CODED.
<br />C
<br />PVC
<br />RG-59U COAX CABLE, #18 GAUGE
<br />221125
<br />2 CONDUCTORS, FOIL SHIELD WITH DRAIN.
<br />NOT USED
<br />E❑
<br />NOT USED
<br />FEi
<br />NOT USED
<br />1. ALL CABLES ARE HOME RUNS FROM THE DEVICE TO THE TERMINAL CABINET UNLESS NOTED OTHERWISE ON THE
<br />DRAWING.
<br />THERE SHALL NOT BE ANY SPLICES IN ANY BOXES. LEAVE TWO FEET OF SLACK AT EACH DEVICE AND
<br />FOUR FEET OF SLACK AT EACH TERMINAL CABINET FOR CONNECTION BY OTHERS.
<br />2. ALL CABLES SHALL HAVE AN IDENTIFICATION TAG INDICATING THE CABLE TYPE LETTER AND THE J-BOX NUMBER
<br />AT EACH END OF EACH CABLE.
<br />3. LEAVE 25' OF SLACK CABLE IN THE CEILING OF THE VAULT FOR CONNECTION BY THE CAMERA VENDOR.
<br />4. ALL SECURITY AND VIDEO CABLE SHALL BE PLENUM RATED.
<br />GENERAL NOTES:
<br />1. ALL CONDUITS TO BE 3/4"C. TO ABOVE CEILING, UNLESS NOTED OTHERWISE.
<br />Seal:
<br />Consultants:
<br />0
<br />ARCHITECTURAL ENGINEERING INCORPORATED
<br />3442 EAST LAKE ROAD, PALM HARBOR, FL 34W5
<br />CONSULTING ENGINEERS (727) 784-1472
<br />CERiIFlGTE OF AUTHORIZATION: FL 38M
<br />W. RONALD MCILVEEN FL PE 30270
<br />f ® !00
<br />Ab
<br />00,
<br />�r
<br />is
<br />!� ■
<br />E L E M E N T S
<br />ARCHITECTS -INTERIOR DESIGNERS
<br />Tampa Office
<br />The Edgewater Building
<br />600 South Magnolia Avenue
<br />Sure 160
<br />Tamr)a, Florida 33606
<br />Phone 813 251-0565
<br />Fox �813 251-0567
<br />Mic-.Imi Office
<br />1699 Coral Nay suite 303
<br />Miami, Florida 33145
<br />Phone 805
<br />05 858-5858
<br />Fax 858--5850
<br />ROUTEWACHOVIA - ZEPHYR COMMONS
<br />US i
<br />w wi FLORIDA
<br />1 1. r f 1 • f•'
<br />Drawkv f t_ ' N> .. 1 by
<br />ELECTRICAL
<br />DETAILSSECURITY SYSTEM
<br />,rr'
<br />
|