Laserfiche WebLink
T.O. BOND BEAM <br />l S' V.LF. <br />G.C. TO PROVIDE TEMPORARY <br />SAW CUT AND REMOVE INSIDE SHELL ONLY <br />SUPPORT & SHORING WITH BACK <br />AS NEEDED TO DRILL AND HILTI HIT HY 150 <br />TO BACK CHANNELS <br />EPDXY SET (1) #5 DOWEL MIN. OF 6" INTO <br />EXISTING BOND BEAM, PROVIDE MIN. OF 24" <br />LAP W/ VERT. REINF., TYR <br />0 0_�', <br />NEW PRECAST LINTEL W/ (1) #5 <br />CONT, (1)#5 DOWEL EA. END TO <br />o <br />0 0 0 <br />0 0 0 <br />o <br />0 <br />AND REMOVE SHELL <br />ABBO LL <br />VERT. REINF. AS SHOWN AND <br />ERIDE <br />ABOVE NTEL ONLY E REQUIRED TO <br />GROUT SOLID, TYP. <br />ENSURE FULLY GROUTED CELLS, TYR <br />T.O. NEW OPENING <br />T4'AEF. <br />INSTALL (1) #5 VERT. [CENTER SPACING] <br />THROUGH JAMB CUTS (REF. SK4-2) AS SHOWN <br />AT EA. SIDE OF OPENING, LAP AND TIE PER <br />ALL CMU CELLS <br />REQUIREMENTS OF GEN. NOTES IF 2 BAR SETS <br />BELOW FINISH <br />REQUIRED FOR INSTALLATION PURPOSES. <br />FLOOR TO BE <br />GROUT FILLED., <br />V.I.F. <br />DRILL AND HILTI HIT HY 150'EPDXY SET <br />(1) #5 DOWEL MIN! OF 6" INTO EXISTING <br />GROUTED CMU BASE, PROVIDE MIN. OF 24" <br />T.O. SLAB <br />LAP W/ VERT. REINF. <br />V-VAEF. <br />T.O. FOOTING <br />4-V V.I.F. <br />Interior Elevation <br />SCALE:N.T.S. <br />REF: <br />EXISTING RAIN HOOD EXISTING SCONCE LIGHT NEW RAIN HOOD <br />OVER REAR DOOR TO FIXTURE TO BE RELOCATED OVER NEW DOOR. <br />BE REPLACED WITH TO 2' TO THE SIDE OF NEW RE: DOOR SCHEDULE <br />LARGER RAIN HOOD DOOR. REWIRE TO NEW <br />TENANT PANEL. RE: E101 <br />EX ® ® EX <br />0 <br />7 EM <br />NEW 2' X 4' ACOUSTICAL TILE <br />CEILINGS MOUNTED AT 10'-0' <br />ABOVE FLOORS IN SPACE <br />F1-F3 IN RESTROOMS ONLY <br />NO CEILING IN MAIN SPACE <br />OR STOCK ROOM OF F1-F3. <br />STRUCTURE ABOVE TO BE <br />PAINTED WHITE. <br />8' LIGHTS SUSPENDED AT <br />12'-0"AFF. RE: E201 <br />EXISTING RAIN <br />HOODS OVER <br />REAR DOORS <br />TO REMAIN AS IS <br />EXISTING LIGHTS IN <br />FIRE RISER ROOM <br />TO REMAIN AS IS. <br />EXISTING CMU, SAW CUT JAMBS AS SHOWN <br />FOR ADDITION OF VERT. REINF. AND GROUT <br />EXISTING CMU, SHOWN WITH ADDED <br />REINF. (CENTER SPACING) AND GROUT <br />Masonry Vert. Reinforcing <br />SCALE:N.T.S. <br />2REF: <br />ALL EXISTING REBAR OUTSIDE OF THE NEW 6'-4' X Te <br />CMU OPENING SHALL REMAIN UNDAMAGED. ALL DEMO <br />WORK AT THE JAMBS AND HEAD OF THE NEW OPENING <br />SHALL BE PERFORMED CAREFULLYAND SURGICALLY <br />SO AS NOT TO DAMAGE ANY OF THE EXISTING REBAR. <br />l'-0' MIN. EXISTING CMU AND SLAB SECTION <br />TO BE REMOVED, GC TO MINIMIZE <br />EXTENTS OF SLAB SECTION REMOVED <br />GC V.I.F. ALL CELLS GROUTED <br />SOLID BELOW FIN. FLR. <br />EXISTING FOOTING TO REMAIN <br />V.I.F. <br />Slab @ New Opening, Demo <br />SCALEAT.S. <br />3 REF: <br />CEILING PLAN GENERAL NOTES: <br />1. ALL NEW CEILINGS SHALL BE 2' X 4' ACT MOUNTED <br />AT 10'-0"AFF WITH NO INSULATION. <br />2. ON THE FRONT OF THE BUILDING, THE EXISTING <br />DECORATIVE SCONCE FIXTURES SHALL REMAIN WIRED <br />AS IS TO THE EXISTING HOUSE PANEL. <br />3. EXISTING REAR WALL MOUNTED LIGHTS SHALL BE WIRED <br />TO THE NEW TENANT PANELS VIA NEW LIGHT SWITCHES. <br />4. THE EXISTING EXIT AND EMERGENCY LIGHTS SHALL BE <br />REUSED IF POSSIBLE. THEY SHALL BE RE -WIRED FROM <br />THE HOUSE PANEL TO THE NEW TENANT PANELS. <br />5. ALL NEW LIGHTS SHALL BE WIRED TO THE NEW PANELS. <br />6. THE RTUS ARE EXISTING AND SHALL REMAIN. ALL NEW <br />SUPPLY DIFFUSERS, RETURN GRILLES, AND EXHAUST FANS <br />SHALL BE TIED INTO THE EXISTING RTUS VIA NEW DUCTWORK. <br />7. THE EXISTING RTUS AND THE NEW EXHAUST FANS SHALL <br />BE WIRED TO THE NEW TENANT PANELS. <br />8. THE FIRE SPRINKLER HEAD LAYOUT SHALL BE DETERMINED <br />BY THE FIRE SPRINKLER SUBCONTRACTOR'S SPECIALTY <br />ENGINEER DURING THE DESIGN OF HIS SHOP DRAWINGS. <br />9. THE EXISTING SPRINKLER HEADS SHALL BE TURNED <br />DOWN & REPOSITIONED AS NEEDED TO COORDINATE <br />WITH HVAC, ELECTRICAL, AND PLUMBING. <br />EXISTING SCONCE EXISTING RAIN <br />LIGHT FIXTURE HOODS OVER <br />TO BE REWIRED. REAR DOORS <br />RE: E101 TO REMAIN AS IS <br />n n <br />EM EM <br />F-C - - <br />EM <br />EMERGENCY LIGHT FIXTURE (EM). <br />WIRED TO NEW TENANT PANEL. <br />REUSE EXISTING IF POSSIBLE. RE: E201 <br />,, F.0 ® Ex <br />EXISTING CANOPY <br />LIGHT FIXTURE <br />TO REMAIN AS IS <br />STRIPED FABRIC AWNING <br />TO BE REPLACED WITH , <br />SOLID FABRIC TO MATCH <br />ADJACENT. AWNING <br />FRAME TO REMAIN AS IS. <br />EXISTING SCONCE <br />LIGHT FIXTURE F 1 F- <br />TO REMAIN AS IS <br />NEW HVAC RETURN AIR <br />GRILLE MOUNTED <br />IN CEILING. RE: M101 <br />EM VILFL-17 EM <br />Fill L EXISTING SOLID <br />i <br />L STRIPED FABRIC AWNING <br />L EXISTING SOLID <br />FABRICAWNING <br />TO BE REPLACED WITH <br />FABRICAWNING <br />TO REMAIN AS IS <br />SOLID FABRIC TO MATCH <br />TO REMAIN AS IS <br />ADJACENT. AWNING <br />-- <br />FRAME TO REMAIN AS IS. <br />EXISTING CANOPY <br />EXISTING SCONCE <br />ACCESS HATCH <br />LIGHT FIXTURE <br />TO REMAIN AS IS <br />TO REMAIN AS IS <br />EXISTING SCONCE <br />LIGHT FIXTURE <br />F 4 } <br />F 6 :! <br />TO REMAIN AS IS <br />EXISTING SCONCE <br />LIGHT FIXTURE <br />TO BE REWIRED. <br />RE: E101 <br />1-. <br />NEW EXHAUST FANS <br />IN RESTROOM <br />CEILINGS. RE: M101 <br />NEW 2 X 4 CEILING <br />MOUNTED LIGHT <br />FIXTURES. RE: E101 <br />NEW HVAC SUPPLY AIR <br />DIFFUSER MOUNTED <br />IN CEILING. RE: M101 <br />NEW Z X 4' ACOUSTICAL TILE <br />CEILINGS MOUNTED AT 10'-0' <br />ABOVE FLOORS IN RESTROOMS <br />AND IN MAIN ROOM OF F4 <br />1 <br />I <br />i <br />i <br />I <br />NEW EXIT LIGHT EXISTING SCONCE <br />FIXTURE (EX) WIRED TO NEW LIGHT FIXTURE <br />TENANT PANEL. REUSE EXISTING TO REMAIN AS IS <br />IF POSSIBLE. RE: E201 <br />F-"t'_ 0:IF-11 <br />Door Schedule <br />DOOR <br />FRAME <br />HARD <br />WARE <br />TYPE <br /># <br />MATERIAL <br />SIZE (EACH) <br />MATERIAL <br />DETAILS <br />SET <br />A <br />DBL <br />HM <br />3'-0" X 7'-0" <br />HM <br />H1, J1, S1 <br />1 <br />X 13/4" <br />B <br />SGL <br />ALUM. <br />3'-0' X 7'-0' <br />ALUM. <br />H2, J2, S2 <br />2 <br />X 13/4' <br />C <br />DBL <br />ALUM, <br />3'-0' X <br />ALUM. <br />H2, J2, S2 <br />3 <br />X 13/4" <br />D <br />SGL <br />WOOD <br />T-0" X V-8" <br />X 13/4' <br />WOOD <br />H3, J3, S3 <br />4 <br />E <br />DBL <br />ABS <br />3'-0' X 8'-0" <br />ABS <br />J4 <br />5 <br />X 1314' <br />vp <br />F <br />SGL <br />HM <br />3'-0' X 7'-0' <br />HM <br />H1, J1, S1 <br />6 <br />X 1314' <br />NOTES: <br />1. PAINT EXTR. OF DOOR "A" TO MATCH EXISTING. LEAVE INTR. PAINT READY. <br />2. PAINT INTR. OF DOOR'D" TO MATCH RESTROOM WALLS. EXTR. SHALL <br />BE <br />PAINT READY. PROVIDE REINFORCED PANELTOACCEPT CLOSER. <br />3. DOOR "E" IS A DOUBLE ACTING IMPACT TRAFFICE DOOR <br />(RUBBAIR ULTRA-LITE WITH WINDOWS). <br />NOA Schedule <br />BUILDING <br />MANUFACTURER <br />NOA# <br />EXPIRATION <br />MATERIAL <br />/ MODEL # <br />DATE <br />STOREFRONT <br />YKK-AP <br />08-0715.14 <br />08-07-13 <br />WINDOWS <br />YES 45 FS <br />STOREFRONT <br />YKK-AP <br />07-M.08 <br />04-16-12 <br />DOORS <br />35D, MEDIUM STILE <br />HOLLOW METAL <br />CECO <br />09-0505.09 <br />08-05-14 <br />REAR DOORS <br />6-0 X 7-0 SWINGING DOOR <br />NOTES: <br />1. THESE NONS ARE PROVIDED TO COMPLY WITH THE FLORIDA BUILDING <br />COMMISSION RULE 913-72. THESE APPROVALS HAVE BEEN REVIEWED FOR <br />APPLICATION ON THIS PROJECT. THE ARCHITECTS SIGNATURE AND SEAL <br />DOES NOT REPLACE OR SUPERCEDE THE PROFESSIONAL RESPONSIBILITY <br />OF THE INDIVIDUAL NONS OR INTERNAL DESIGN COMPONENTS THEREOF. <br />2. THE CONTRACTOR MAY SUBMIT ALTERNATES FOR ANY OF THE BUILDING <br />COMPONENTS ON THIS LISTAS LONG AS IT DOES NOT VIOLATE ANY <br />EXISTING WARRANTIES THAT MAY BE IN EFFECT. IN ORDER TO RECEIVE <br />APPROVAL ON ANY ALTERNATES, THE GC MUST SUBMIT PRODUCT <br />INFORMATION TO THE OWNER FOR REVIEW AS WELL AS TO THE LOCAL <br />JURISDICTION AS REQUIRED FOR PERMITTING AND C.O. <br />3. THE MAXIMUM DESIGN PRESSURE THAT THESE COMPONENTS NEED TO <br />WITHSTAND IS + / - 36.1 PSF. IMPACT RESISTANCE IS NOT REQUIRED. <br />SAWCUT CMU, <br />POINT IN RAIN <br />HOOD, CAULK <br />CONT <br />22 GA. GALV. <br />MTL. RAINHOOD, <br />PAINT TO <br />MATCH DOORS. <br />HOOD TO <br />EXTEND 8' <br />PAST EDGE <br />OF DOOR ON <br />BOTH SIDES <br />GROUT <br />SOLID <br />CONT. CAULK FULL DOOR <br />PERIMETER WEATHER <br />STRIP <br />4" <br />HEAD DETAIL - H1 <br />GROUT SOLID <br />FULL DOOR <br />WEATHER STRIP <br />MASONRY JAMB <br />ANCHOR AS REQ. <br />\ CAULK PERIMETER <br />CONT. TYP <br />JAMB DETAIL - J1 <br />DOOR FRAME <br />'OND) <br />THRESHOLD <br />V MASTIC (TYR) <br />iH FLOOR <br />-LOOR PLAN <br />SILL DETAIL - S1 <br />COORDINATE ALL EXTERIOR DOOR DETAILS <br />5 Door Details WITH THE REQUIREMENTS OF THE ASSOCIATED <br />SCALE: 3" = V-0" FLORIDA PRODUCT APPROVAL (NOA) <br />Hardware Schedule <br />HARDWARE SET # 1: (REAR HOLLOW METAL DOOR) <br />(6) - HAGER 4-1/2' X 4-10 BUTT FULL MORTISE <br />HINGES NO. BB1191 (NRP). STAINLESS <br />STEEL HINGES W/ STAINLESS STEEL PINS <br />(1) - LOCKSET SCHLAGE AL53PD'ENTRANCE <br />LOCK'. FINISH 626 (US 26D) SATIN CHROME <br />(1) - CLOSER - LCN NO.4040. STANDARD POWDER <br />COAT ALUMINUM FINISH. STANDARD PLASTIC <br />COVER. MOUNTED ON INTERIOR SIDE <br />(1) - SET FULL WEATHERSTRIP <br />(1) - DOOR SWEEP <br />(1)-ALUMINUM THRESHOLD (ADA COMPLIANT) <br />(1) - RAINHOOD. RE: HEAD DETAIL <br />(1) - ASTRAGAL <br />(1) - FLOOR BOLT FOR SECONDARY LEAF <br />(1)-1.5',180 DEGREE PANORAMIC VIEWER <br />(1) - DOOR STRIKE COVER PLATE <br />HARDWARE SET # 2: (STOREFRONT DOOR) <br />(1) - SET SINGLE ACTING OFFSET PIVOT HINGES <br />(1) - DOOR CLOSER - NORTON 1601(ADJUSTABLE FORCE) <br />(1) - MILL FINISH ALUMINUM THRESHOLD (FOR <br />OFFSET PIVOTAND OVERHEAD CLOSER) <br />(1) -ADAMS RITE MS+1890 DEADLOCK/ LATCH COMBINATION <br />(1) -ADAMS RITE 4590 LATCH PADDLE DEVICE <br />(1) -ADAMS RITE STANDARD LATCH STRIKE <br />(1) - CYLINDER - SCHLAGE (7PIN) MORTISE <br />(1) - CP II DOOR PUSH & CO-9 PULL #14 <br />(1) - SEALAIR WEATHERING SYSTEM & EPDM <br />BLADE SURFACE ATTACHED SWEEP STRIP <br />(1) - STENCILLED NOTE: "DOOR TO REMAIN <br />UNLOCKED DURING STORE OPERATION' <br />HARDWARE SET # 3: (STOREFRONT DOOR) <br />(2) - SET SINGLE ACTING OFFSET PIVOT HINGES <br />(2) - DOOR CLOSER - NORTON 1601 (ADJUSTABLE FORCE) <br />(1) - MILL FINISH ALUMINUM THRESHOLD (FOR <br />OFFSET PIVOT AND OVERHEAD CLOSER) <br />(1) - ADAMS RITE MS+1890 DEADLOCK I LATCH COMBINATION <br />(1) - ADAMS RITE 4590 LATCH PADDLE DEVICE <br />(1) -ADAMS RITE STANDARD LATCH STRIKE <br />(1) - CYLINDER - SCHLAGE (7PIN) MORTISE <br />(2) - CP II DOOR PUSH & CO-9 PULL #14 <br />(1) - SEALAIR WEATHERING SYSTEM & EPDM <br />BLADE SURFACE ATTACHED SWEEP STRIP. <br />(1) - STENCILLED NOTE: "DOOR TO REMAIN <br />UNLOCKED DURING STORE OPERATION' <br />HARDWARE SET # 4: (RESTROOM DOOR) <br />(3) - HAGER 4-1/2' X 4-1/2' BUTT FULL MORTISE <br />HINGES NO. BB1191(NRP). STAINLESS <br />STEEL HINGES W/ STAINLESS STEEL PINS <br />(1) - LOCKSET SCHLAGE AL40S 'PRIVACY LOCK' <br />FINISH 626 (US 26D) SATIN CHROME <br />(1) - CLOSER - LCN NO.4040. STANDARD POWDER <br />COATALUMINUM FINISH. STANDARD PLASTIC <br />COVER. MOUNTED ON INSIDE OF ROOM <br />(1) - WALL STOP <br />(3) - SILENCERS <br />HARDWARE SET # 5: (STOCKROOM DOOR) <br />(2) -10.5" X 23' SEALED VISION PANEL WINDOW <br />EACH WITH RADIUS GASKET <br />(1) - SET OF REMOVABLE FULL PERIMETER SEALS <br />(2) - 8-3/4' HIGH STANDARD JAMB GUARDS <br />(1) - HARDWARE: CAM LIFT 90 DEG. X 90 DEG. <br />HARDWARE SET # 6: (REAR HOLLOW METAL DOOR) <br />(3) - HAGER 4-1/2' X 4-1/2' BUTT FULL MORTISE <br />HINGES NO. BB1191(NRP). STAINLESS <br />STEEL HINGES W/ STAINLESS STEEL PINS <br />(1) - LOCKSET SCHLAGE AL53PD'ENTRANCE <br />LOCK". FINISH 626 (US 26D) SATIN CHROME <br />(1) - CLOSER - LCN NO.4040. STANDARD POWDER <br />COATALUMINUM FINISH. STANDARD PLASTIC dill <br />COVER. MOUNTED ON INTERIOR SIDE <br />(1) - SET FULL WEATHERSTRIP <br />(1) - DOOR SWEEP <br />(1) -ALUMINUM THRESHOLD (ADA COMPLIANT) <br />(1) - RAINHOOD. RE: HEAD DETAIL <br />(1) - DOOR STRIKE COVER PLATE <br />�41 <br />HEAD DETAIL - H2 <br />ALUM. <br />STOREFRONT <br />SYSTEM <br />ALUM. JAMB <br />BEYOND <br />ALUM. DOOR <br />RE: DOOR <br />SCHEDULE <br />W I TF'. <br />BELOW <br />ru.um. uwr% <br />RE: DOOR SCHEDULE <br />JAMB DETAIL - J2 <br />SILL DETAIL - S2 <br />ALUM. JAMB BEYOND <br />APPLIED SWEEP <br />ALUM. THRESHOLD <br />BY STOREFRONT <br />INSTALLER <br />EXISTING CONCRETE <br />FLOOR SLAB <br />EXISTING EXTR <br />SIDEWALK <br />�N <br />oLu <br />o� <br />z <br />U <br />io <br />Hardware Notes <br />1. ADJUSTALL CLOSERS TOA5 LB MAX OPENING FORCE. <br />2. ALL LOCK & PASSAGE SETS TO BE SCHLAGE GRADE OR BETTER. <br />LOCKS NEED TO BE REKEYABLE. <br />3. ALL DOORS & HARDWARE TO COMPLY WITH NFPA 101-5-2.1.5. <br />4. ALL DOORS & HARDWARE TO COMPLY WITH THE FLORIDA <br />ACCESSIBILITY CODE & THE ADA FEDERAL REGULATION CODES, <br />UTILIZING A LEVER LATCH OR LOCKSET. <br />5. FINAL CORE PROCESS FOR LOCKSETS & KEYING SHALL BE: THE <br />SUBCONTRACTORS WILL INSTALLALL DOORS, FRAMES, HARDWARE <br />& LOCKSETS. <br />DOUBLE 2X BLOCKING MIN. ATJAMBS. PROVIDE EXACT <br />SUPPORT RECOMMENDED BY DOOR MANUFACTURER - <br />!STEEL ANGLE MOUNTED <br />TO HEADER AND .JAMB <br />HARDWARE COVER <br />TOP MOUNTNG <br />BRACKET <br />1,/80 THICK � - <br />ASS FACING <br />LOWER <br />PIVOT PIN <br />8-3/4- STEEL' <br />JAMB GUARD <br />HEAD DETAIL - H3 <br />JAMB DETAIL - J3 <br />SILL DETAIL - S3 <br />6AM131> <br />MOUNTING DETAIL <br />OFFSET PIVOT HARDWARE <br />DOOR ROTATED FOR CLARITY <br />JAMB DETAIL - J4 <br />RE: WALL TYPES FOR <br />FRAMING, SHEATHING, & <br />INSULATION INFORMATION <br />CONT. 2X WOOD BLOCKING <br />AT ENTIRE PERIMETER OF <br />ROUGH OPENING <br />SOLID WOOD DOOR <br />FRAME. PAINT INTERIOR <br />TO MATCH DOOR. EXTR <br />TO BE PAINT READY <br />RE: DOOR SCHEDULE <br />FLUSH HOLLOW CORE <br />WOOD DOOR <br />RE: DOOR SCHEDULE <br />RE: WALL TYPES FOR <br />FRAMING, SHEATHING, & <br />INSULATION INFORMATION <br />CONT 2X WOOD BLOCKING <br />AT ENTIRE PERIMETER OF <br />ROUGH OPENING <br />FLUSH HOLLOW CORE <br />WOOD DOOR <br />RE: DOOR SCHEDULE <br />SOLID WOOD DOOR <br />FRAME. PAINT INTERIOR <br />TO MATCH DOOR. EXTR <br />TO BE PAINT READY <br />RE: DOOR SCHEDULE <br />HC WOOD DOOR. RE: SCHED. <br />SOLID WOOD DOOR <br />FRAME (BEYOND) <br />COORDINATE UNDERCUT SIZE <br />WITH MECHANICAL PLANS <br />RE: FLOOR PLAN FOR <br />FINISH INFORMATION <br />� <br />N <br />Q <br />O <br />8 <br />� <br />1 <br />^., <br />0 <br />Uw <br />-_-w <br />V _ <br />a <br />a� <br />� U <br />�� 3 <br />3 <br />Cf) <br />C <br />0 <br />E <br />E <br />0 <br />CD <br />L <br />i <br />N o <br />6-+ J <br />CU mm <br />� Y <br />U Q <br />oes <br />0 <br />M <br />LjL m <br />1 'J <br />J <br />r Q <br />UL CD <br />(n N <br />ai00 <br />� <br />ao <br />J <br />�--"lqt_ <br />w <br />a CU F- >_ <br />o0 W <br />Ca <br />ai <br />U <br />U <br />w <br />CD <br />w ry <br />0 <br />w <br />w <br />a <br />w <br />~ <br />to <br />W <br />� <br />a <br />a. <br />U <br />0 <br />4 <br />N <br />N <br />S <br />CN <br />0 <br />a <br />� <br />z <br />rn�' <br />w <br />co <br />Z <br />_ <br />N <br />N <br />?' <br />0w <br />m <br />O <br />TENANT BUILD OUT <br />Al 03 <br />eN <br />4 Reflected Ceiling Plan <br />SCALE: 1/8' = V-V <br />